High-Efficiency Heat Exchangers

Stacked, corrugated plates maximize contact with liquid or steam flowing through these brazed plate heat exchangers for faster heat transfer than shell and tube heat exchangers. Plates are brazed in a vacuum furnace to ensure 100% sealed construction.
ASME BPVC VIII.1 copper-brazed heat exchangers have a Btu/hr. cooling capacity based on cooling 100 SSU oil to 125° F using 85° F water.
ASME BPVC VIII.1 heat exchangers meet the ASME Boiler and Pressure Vessel Code (BPVC) for construction of pressure vessels.
For technical drawings and 3-D models, click on a part number.
Overall | Mounting Hole | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heating/Cooling Cap., Btu/hr. | Surface Area, sq. ft. | Temp. Range, °F | Pipe Size | Thread Type | Gender | Flow Cap., gpm | Max. Pressure, psi | Ht. | Wd. | Dp. | No. of | Dia. | Each | |
ASME BPVC.VIII.1 Heat Exchangers | ||||||||||||||
Copper-Brazed 316 Stainless Steel Plate | ||||||||||||||
5,000 | 4.8 | -310° to 450° | 3/4 | NPT | Male | 27 | 435 | 8 7/16" | 3 3/16" | 4 7/16" | 2 | 9/32" | 0000000 | 0000000 |
12,000 | 7.9 | -310° to 450° | 1 | NPT | Male | 29 | 435 | 12 3/16" | 4 3/8" | 4 1/4" | 2 | 13/32" | 0000000 | 000000 |
17,000 | 10.7 | -310° to 450° | 1 | NPT | Male | 37 | 435 | 12 3/16" | 4 3/8" | 5 1/4" | 2 | 13/32" | 0000000 | 000000 |
50,000 | 15.6 | -310° to 450° | 1 | NPT | Male | 22 | 435 | 20 11/16" | 4 3/8" | 4 1/4" | 2 | 13/32" | 0000000 | 000000 |
75,000 | 26.8 | -310° to 450° | 1 | NPT | Male | 34 | 435 | 20 11/16" | 4 3/8" | 6 3/16" | 2 | 13/32" | 0000000 | 00000000 |
125,000 | 29.7 | -310° to 450° | 2 | NPT | Male | 57 | 435 | 24 5/16" | 7 1/2" | 5 3/4" | 2 | 1/2" | 0000000 | 00000000 |
380,000 | 82.8 | -310° to 450° | 2 | NPT | Male | 141 | 435 | 24 5/16" | 7 1/2" | 11 1/2" | 2 | 1/2" | 0000000 | 00000000 |
Heat Exchangers

Also known as shell and tube heat exchangers, these transfer heat using liquid or steam that flows through the shell to heat or cool liquid in the tubes. They’re commonly used in refrigeration and engine cooling systems. Btu/hr. cooling capacity is based on cooling 180° F process water with 85° F water and a 10 psi pressure difference.
ASME BPVC VIII.1 heat exchangers meet the ASME Boiler and Pressure Vessel Code (BPVC) for construction of pressure vessels.
For technical drawings and 3-D models, click on a part number.
Shell-Side | Tube-Side | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Heating/Cooling Cap., Btu/hr. | Surface Area, sq. ft. | No. of Passes | Min. Temp., °F | Max. Temp., °F | Pipe Size | Flow Cap., gpm | Max. Pressure, psi | Pipe Size | Flow Cap., gpm | Max. Pressure, psi | Lg. | Head Dia. | Each | |
150,000 | 4.5 | 2 | -20° | 375° | 2 (Inlet); 1 (Outlet) | 44 | 150 | 1 1/2 | 44 | 150 | 28 1/2" | 7 1/4" | 0000000 | 000000000 |
420,000 | 6.8 | 2 | -20° | 375° | 2 (Inlet); 1 (Outlet) | 44 | 150 | 1 1/2 | 44 | 150 | 40 1/2" | 7 1/4" | 0000000 | 00000000 |
720,000 | 9.2 | 2 | -20° | 375° | 3 (Inlet); 1 (Outlet) | 44 | 150 | 1 1/2 | 44 | 150 | 52 1/2" | 7 1/4" | 0000000 | 00000000 |
1,350,000 | 17.4 | 2 | -20° | 375° | 2 1/2 (Inlet); 1 (Outlet) | 175 | 150 | 2 | 175 | 150 | 53 1/4" | 10 1/2" | 0000000 | 00000000 |