    Harsh-Environment Circuit Breakers

    Built to resist vibration and corrosion in harsh environments, these circuit breakers protect against overload and short circuits in low-voltage automotive and other electronic applications. All are thermal, so they use the heat generated in overcurrent situations to trip the breaker.
    Lever Manual Reset and Push-Pull Button Manual Reset—Push-pull button and lever style breakers can be used as an on/off switch.
    UL 1077—Place UL 1077-rated breakers downstream from a branch circuit breaker to protect a single piece of equipment. They are also known as supplemental protectors.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Mounting
    Holes
    Screw On
    Current,
    A
    Voltage,
    V DC
    Breakthrough Current
    @ Voltage
    For Panel
    Cutout Dia.
    Dp. Behind
    Panel
    Mounting
    Location
    No.
    of
    Dia.
    Mounting Fasteners
    Included
    Wire
    Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole—Push-Pull-Button Style
    Image of Product. Front orientation. Circuit Breakers. Harsh-Environment Circuit Breakers, 1 Pole—Push-Pull-Button Style.
     
    Thermal
    30286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T11000000
    35286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1200000
    40286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1300000
    45286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1400000
    50 286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1500000
    55286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1600000
    60286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1700000
    70286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1800000
    80286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1900000
    90286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T2100000
     
    1 Pole—Lever Style
    Image of Product. Front orientation. Circuit Breakers. Harsh-Environment Circuit Breakers, 1 Pole—Lever Style.
     
    Thermal
    30481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22200000
    40481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22300000
    50 481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22400000
    60481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22500000
    70481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22600000
    80481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22700000
    100481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22800000
    120481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22900000
    135481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K23100000
    150481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K23200000
     
    1 Pole—Push-Button Style
    Image of Product. Front orientation. Circuit Breakers. Harsh-Environment Circuit Breakers, 1 Pole—Push-Button Style.
     
    Thermal
    30481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13100000
    40481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13200000
    50 481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13300000
    60481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13400000
    70481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13500000
    80481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13600000
    90481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13700000
    100481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13800000
    120481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13900000
    135481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K14100000
    150481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K14200000
     

    Stud-Terminal Relays

    Image of Product. 12VA Control Power. Front orientation. Contains Annotated. Relays. Stud-Terminal Relays, 1 Circuit Controlled, 3.1" Wide, 2.2" Deep.
    Image of Product. 9VA Control Power. Front orientation. Contains Annotated. Relays. Stud-Terminal Relays, 1 Circuit Controlled, 3.5" Wide, 2.4" Deep.

    12VA Control Power

    9VA Control Power

    These relays are suitable for DC-powered equipment such as forklifts, floor scrubbers, and trucks. They are rated for continuous operation for cycles that run longer than 30 seconds.
    3 Terminals—3-terminal relays require the same input and switching voltage.
    4 Terminals and 6 Terminals—4- and 6-terminal relays allow different input and switching voltages.
    No. of
    Terminals
    Input Voltage,
    V DC
    Control
    Power, W
    Switching Current
    @ Voltage
    Load
    Type
    Ht.
    Wd.
    Dp.
    Stud Thread
    Size
    Features
    Each
    1 Circuit Controlled with 1 Off—SPST-NO
     
    Surface Mount
    31212100 amp @ 12V DCFull3.6"3.1"2.2"5/16"-24
    7995K23000000
    412980 amp @ 12V DCFull2.5"3.5"2.4"5/16"-24
    7995K1100000
    412980 amp @ 12V DCFull2.5"3.5"2.4"5/16"-24
    Relays with Grounding Cord with Ring Terminal7995K4400000
    41212100 amp @ 12V DCFull3.6"3.1"2.2"5/16"-24
    7995K2100000
    424950 amp @ 24V DCFull2.5"3.5"2.4"5/16"-24
    7995K1200000
    42412100 amp @ 24V DCFull3.6"3.1"2.2"5/16"-24
    7995K2500000
    436950 amp @ 36V DCFull2.5"3.5"2.4"5/16"-24
    7995K4500000
    43612100 amp @ 36V DCFull3.6"3.1"2.2"5/16"-24
    7995K2200000
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
     
    Surface Mount
    61212100 amp @ 12V DCFull4.7"3.1"2.2"5/16"-24
    7995K46000000
    62412100 amp @ 24V DCFull4.7"3.1"2.2"5/16"-24
    7995K47000000
    63612100 amp @ 36V DCFull4.7"3.1"2.2"5/16"-24
    7995K2400000
     

    Vehicle Relays

    Image of Product. Front orientation. Vehicle Relays. Vehicle Relays, Relay-Socket and Surface Mount, 4 Terminals.
    Image of Product. Front orientation. Vehicle Relays. Vehicle Relays, Relay-Socket and Surface Mount, 5 Terminals.
    Image of Product. Front orientation. Vehicle Relays. Vehicle Relays, Relay-Socket Mount, 4 Terminals.

    Relay-Socket and

    Surface Mount, 4

    Terminals

    Relay-Socket and

    Surface Mount, 5

    Terminals

    Relay-Socket

    Mount, 4

    Terminals

    Image of Product. Front orientation. Vehicle Relays. Vehicle Relays, Relay-Socket Mount, 5 Terminals.
    Image of Product. Front orientation. Relay Sockets. Vehicle Relays, Sockets with Crimp- On Terminals.
    Image of Product. Front orientation. Relay Sockets. Vehicle Relays, Sockets with Wire Leads.

    Relay-Socket

    Mount, 5

    Terminals

    Sockets with

    Crimp- On

    Terminals

    Sockets with Wire

    Leads

    These relays handle the high starting (inrush) currents that often occur when turning on a vehicle. Also known as ISO relays, their blade terminals meet ISO 8092-1 dimensional standards to fit in road vehicles for easy maintenance and repair.
    Relays with surge suppression coverage prevent damage to sensitive equipment by reducing the 300V to 500V spike that happens when you switch relays off.
    Surface Mount—Relays for surface mounting have a tab for added security in high-vibration applications.
    Partial—Relays with partial surge suppression coverage bring this spike down to 100V.
    Full—Relays with full surge suppression coverage eliminate the voltage spike.
    Dual Output—Relays with dual output let you control two separate loads or circuits independently. For example, in a car window, these relays could control it moving up and down.
    Vehicle Relays
    Sockets with
    Crimp- On Terminals
    Sockets with
    Wire Leads
    Switching Current @ Voltage
    No. of
    Terminals
    Input Voltage,
    V DC
    Off (Normally Open)
    Circuit Position
    On (Normally Closed)
    Circuit Position
    Max. Switching
    Voltage, V DC
    Max. Starting
    Current, amp
    Control Current,
    mA
    Surge Suppression
    Coverage
    Relay Terminal
    Layout
    Ht.
    Wd.
    Dp.
    Quick-Disconnect
    Tab Wd.
    Features
    Each
    Each
    Each
    Relay-Socket Mount
     
    1 Circuit Controlled with 1 Off—SPST-NO
    41240 amp @ 12V DC18150155PartialType B1"1"0.9"0.25"9672K1130000008228K42000008228K13000000
    41240 amp @ 12V DC20150141Type B1"1"0.9"0.25"9672K115000008228K4200008228K1300000
    41250 amp @ 12V DC18200138PartialType B1"1"0.9"0.25", 0.375"9672K102000008228K4300008228K1200000
    42420 amp @ 24V DC317570Type B1"1"0.9"0.25"9672K12300008228K4200008228K1300000
    42420 amp @ 24V DC3615095PartialType B1"1"0.9"0.25"9672K124000008228K4200008228K1300000
    51240 amp @ 12V DC20150141Type B1"1"0.9"0.25"Dual Output9672K114000008228K4200008228K1300000
    52420 amp @ 24V DC4012069Type B1"1"0.9"0.25"Dual Output9672K33000008228K4200008228K1300000
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    51230 amp @ 12V DC20 amp @ 12V DC18150138Type B1"1"0.9"0.25"9672K3100008228K1600008228K1300000
    51240 amp @ 12V DC20 amp @ 12V DC18150133FullType B1"1"0.9"0.25"9672K106000008228K4200008228K1300000
    51240 amp @ 12V DC20 amp @ 12V DC18150155PartialType B1"1"0.9"0.25"9672K107000008228K4200008228K1300000
    51240 amp @ 12V DC20 amp @ 12V DC20150141Type B1"1"0.9"0.25"9672K105000008228K4200008228K1300000
    51240 amp @ 12V DC20 amp @ 12V DC20150163PartialType B1"1"0.9"0.25"9672K108000008228K4200008228K1300000
    52420 amp @ 24V DC10 amp @ 24V DC3615075FullType B1"1"0.9"0.25"9672K117000008228K4200008228K1300000
    52420 amp @ 24V DC10 amp @ 24V DC3615099PartialType B1"1"1"0.25"9672K8100008228K4200008228K1300000
    52420 amp @ 24V DC10 amp @ 24V DC4012069Type B1"1"0.9"0.25"9672K118000008228K4200008228K1300000
     
    Relay-Socket and Surface Mount
     
    1 Circuit Controlled with 1 Off—SPST-NO
    41230 amp @ 12V DC18150133Type A1"1"1"0.25"9672K126000008228K4200008228K1400000
    41240 amp @ 12V DC18150155PartialType B1"1"0.9"0.25"9672K112000008228K4200008228K1400000
    41250 amp @ 12V DC18150138Type B1.2"1"1"0.25", 0.375"9672K36000008228K4300008228K1200000
    41270 amp @ 12V DC12200155Type B1.03"1.03"0.9"0.25", 0.375"9672K131000008228K4300008228K1200000
    42420 amp @ 24V DC3615095PartialType B1"1"0.9"0.25"9672K125000008228K4200008228K1400000
    42430 amp @ 24V DC4012067Type A1"1"1"0.25"9672K127000008228K4200008228K1400000
    42470 amp @ 24V DC4020075Type B1.5"1.4"1"0.25", 0.375"9672K37000008228K4300008228K1200000
    51240 amp @ 12V DC20150141Type B1"1"0.9"0.25"Dual Output9672K29000008228K4200008228K1400000
    51240 amp @ 12V DC20150141FullType B1"1"0.9"0.25"Dual Output9672K116000008228K4200008228K1400000
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    51230 amp @ 12V DC20 amp @ 12V DC18150138Type B1.1"1.1"1"0.25"9672K3200008228K1700008228K1400000
    51240 amp @ 12V DC20 amp @ 12V DC20150141Type B1"1"0.9"0.25"9672K109000008228K4200008228K1400000
    51240 amp @ 12V DC20 amp @ 12V DC20150163PartialType B1"1"0.9"0.25"9672K111000008228K4200008228K1400000
    52420 amp @ 24V DC10 amp @ 24V DC4012069Type B1"1"0.9"0.25"9672K121000008228K4200008228K1400000
    52420 amp @ 24V DC10 amp @ 24V DC4012069FullType B1"1"0.9"0.25"9672K119000008228K4200008228K1400000
    52420 amp @ 24V DC10 amp @ 24V DC40120109PartialType B1"1"0.9"0.25"9672K82000008228K4200008228K1400000
     

    Water-Resistant Stud-Terminal Relays

    Image of Product. 8.1VA Control Power. Front orientation. Contains Annotated. Relays. Water-Resistant Stud-Terminal Relays, 1 Circuit Controlled, 3.3" Wide, 2.1" Deep.
    Image of Product. 8VA and 12VA Control Power. Front orientation. Contains Annotated. Relays. Water-Resistant Stud-Terminal Relays, 1 Circuit Controlled, 3.3" Wide, 2.9" Deep.

    8.1VA Control Power

    8VA and 12VA Control

    Power

    Sealed to keep out water, these relays are often used for DC-powered equipment such as forklifts, floor scrubbers, and trucks. They are rated for continuous operation for cycles that run longer than 30 seconds.
    No. of
    Terminals
    Input Voltage,
    V DC
    Control
    Power, W
    Switching Current
    @ Voltage
    Load
    Type
    Ht.
    Wd.
    Dp.
    Stud Thread
    Size
    Each
    1 Circuit Controlled with 1 Off—SPST-NO
     
    Surface Mount
    4128200 amp @ 12V DCFull3.7"3.3"2.9"5/16"-24
    7995K31000000
    4128.1100 amp @ 12V DCFull2.9"3.3"2.1"5/16"-24
    7995K4100000
    4248.1100 amp @ 24V DCFull2.9"3.3"2.1"5/16"-24
    7995K4200000
    4368.1100 amp @ 36V DCFull2.9"3.3"2.1"5/16"-24
    7995K4300000
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
     
    Surface Mount
    61212100 amp @ 12V DCFull4.6"3.3"2.9"5/16"-24
    7995K32000000
    62412100 amp @ 24V DCFull4.6"3.3"2.9"5/16"-24
    7995K33000000
     

    Blade-Style Circuit Breakers

    Protect against overload and short circuits in low-voltage automotive and other electronic applications. These circuit breakers can replace type ATC, AF, ATO, and 257 blade-style fuses. They are thermal, so they trip when heat is generated by overload current.
    Automatic Reset
    Image of Product. Front orientation. Circuit Breakers. Blade-Style Circuit Breakers, Automatic Reset.
    Automatic reset breakers don’t require you to manually reset them after they trip, so they’re good for areas where the breaker isn’t easily accessed. These breakers reset once they cool. However, they will trip repeatedly if the overcurrent condition continues.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Breakthrough Current
    @ Voltage
    Mounting
    Location
    Ht.
    Wd.
    Blade
    Ht.
    Temp. Range,
    ° F
    Enclosure
    Rating
    Specs.
    Met
    Each
    12V DC
    62,000 amp @ 12V DCFuse Block0.95"0.79"0.25"-40 to 185IP54
    SAE J5534212T1100000
    82,000 amp @ 12V DCFuse Block0.95"0.79"0.25"-40 to 185IP54
    SAE J5534212T120000
    102,000 amp @ 12V DCFuse Block0.95"0.79"0.25"-40 to 185IP54
    SAE J5534212T130000
    152,000 amp @ 12V DCFuse Block0.95"0.79"0.25"-40 to 185IP54
    SAE J5534212T140000
    202,000 amp @ 12V DCFuse Block0.95"0.79"0.25"-40 to 185IP54
    SAE J5534212T150000
    252,000 amp @ 12V DCFuse Block0.95"0.79"0.25"-40 to 185IP54
    SAE J5534212T160000
    302,000 amp @ 12V DCFuse Block0.95"0.79"0.25"-40 to 185IP54
    SAE J5534212T170000
     
    Manual Reset—Push-Button Style
    Image of Product. Front orientation. Circuit Breakers. Blade-Style Circuit Breakers, Manual Reset—Push-Button Style.
    Manual reset breakers require you to push a button after they trip.
    UL 1077—Place UL 1077-rated breakers downstream from a branch circuit breaker to protect a single piece of equipment. They are also known as supplemental protectors.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Breakthrough Current @ Voltage
    Mounting
    Location
    Ht.
    Wd.
    Blade
    Ht.
    Temp. Range,
    ° F
    Enclosure
    Rating
    Specs.
    Met
    Each
    24V DC
    62,000 amp @ 24V DCFuse Block1.16"0.79"0.25"-40 to 185IP30
    4212T31000000
    82,000 amp @ 24V DCFuse Block1.16"0.79"0.25"-40 to 185IP30
    4212T3200000
    102,000 amp @ 24V DCFuse Block1.16"0.79"0.25"-40 to 185IP30
    4212T3300000
    152,000 amp @ 24V DCFuse Block1.16"0.79"0.25"-40 to 185IP30
    4212T3400000
    202,000 amp @ 24V DCFuse Block1.16"0.79"0.25"-40 to 185IP30
    4212T3500000
    252,000 amp @ 24V DCFuse Block1.16"0.79"0.25"-40 to 185IP30
    4212T3600000
    302,000 amp @ 24V DCFuse Block1.16"0.79"0.25"-40 to 185IP30
    4212T3700000
     
    48V DC
    32,000 amp @ 48V DCFuse Block1 1/2"0.87"0.25"-40 to 185IP40
    SAE J5534212T4100000
    42,000 amp @ 48V DCFuse Block1 1/2"0.87"0.25"-40 to 185IP40
    SAE J5534212T4200000
    52,000 amp @ 48V DCFuse Block1 1/2"0.87"0.25"-40 to 185IP40
    SAE J5534212T4300000
    62,000 amp @ 48V DCFuse Block1 1/2"0.87"0.25"-40 to 185IP40
    SAE J5534212T4400000
    7 1/2 2,000 amp @ 48V DCFuse Block1 1/2"0.87"0.25"-40 to 185IP40
    SAE J5534212T4500000
    82,000 amp @ 48V DCFuse Block1 1/2"0.87"0.25"-40 to 185IP40
    SAE J5534212T4600000
    102,000 amp @ 48V DCFuse Block1 1/2"0.87"0.25"-40 to 185IP40
    SAE J5534212T4700000
    152,000 amp @ 48V DCFuse Block1 1/2"0.87"0.25"-40 to 185IP40
    SAE J5534212T4800000
    202,000 amp @ 48V DCFuse Block1 1/2"0.87"0.25"-40 to 185IP40
    SAE J5534212T4900000
    252,000 amp @ 48V DCFuse Block1 1/2"0.87"0.25"-40 to 185IP40
    SAE J5534212T5100000
     
    72V DC
    250V AC
    1/42,000 amp @ 250V AC
    2,000 amp @ 72V DC
    Fuse Block2.06"0.96"0.25"0 to 140UL 10776493T1100000
    1/22,000 amp @ 250V AC
    2,000 amp @ 72V DC
    Fuse Block2.06"0.96"0.25"0 to 140UL 10776493T1200000
    12,000 amp @ 250V AC
    2,000 amp @ 72V DC
    Fuse Block2.06"0.96"0.25"0 to 140UL 10776493T1300000
    1 1/22,000 amp @ 250V AC
    2,000 amp @ 72V DC
    Fuse Block2.06"0.96"0.25"0 to 140UL 10776493T1400000
    22,000 amp @ 250V AC
    2,000 amp @ 72V DC
    Fuse Block2.06"0.96"0.25"0 to 140UL 10776493T1500000
    2 1/22,000 amp @ 250V AC
    2,000 amp @ 72V DC
    Fuse Block2.06"0.96"0.25"0 to 140UL 10776493T1600000
    32,000 amp @ 250V AC
    2,000 amp @ 72V DC
    Fuse Block2.06"0.96"0.25"0 to 140UL 10776493T1700000
    42,000 amp @ 250V AC
    2,000 amp @ 72V DC
    Fuse Block2.06"0.96"0.25"0 to 140UL 10776493T1800000
    52,000 amp @ 250V AC
    2,000 amp @ 72V DC
    Fuse Block2.06"0.96"0.25"0 to 140UL 10776493T1900000
    62,000 amp @ 250V AC
    2,000 amp @ 72V DC
    Fuse Block2.06"0.96"0.25"0 to 140UL 10776493T2100000
    82,000 amp @ 250V AC
    2,000 amp @ 72V DC
    Fuse Block2.06"0.96"0.25"0 to 140UL 10776493T2200000
    102,000 amp @ 250V AC
    2,000 amp @ 72V DC
    Fuse Block2.06"0.96"0.25"0 to 140UL 10776493T2300000
     
    DIN-Rail Mount Holders for 250V AC/72V DC Circuit Breakers

    Ribbon Switches

    Step or press anywhere along the switch to control doors, lights, or alarms. These switches are often placed across driveways and walkways to detect foot and vehicle traffic. Rated IP67, they can be temporarily submerged in puddles without the water harming their internal parts. These switches are bright yellow, so they can easily be spotted from far away. Made from PVC, they are flexible enough to conform to irregular and uneven surfaces.
    With Wire Lead Connection
    Image of Product. Front orientation. Ribbon Switches. Ribbon Switches.
    Wire
    Leads
    Yellow
    Lg.,
    ft.
    Wd.
    Thk.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage
    No.
    of
    Lg.,
    ft.
    Ga.
    Material
    Enclosure
    Rating
    Actuation
    Force, lbf
    Each
    34"5/8"11 Off
    Momentary
    SPST-NO
    1 amp @ 24V AC/24V DC24V AC/24V DC21820
    PVC
    IP67
    205677N110000000
    54"5/8"11 Off
    Momentary
    SPST-NO
    1 amp @ 24V AC/24V DC24V AC/24V DC21820
    PVC
    IP67
    205677N12000000

    Weatherproof Vehicle Relays

    Image of Product. Front orientation. Contains Annotated. Vehicle Relays. Weatherproof Vehicle Relays, Relay-Socket Mount.
    Image of Product. Front orientation. Contains Annotated. Vehicle Relays. Weatherproof Vehicle Relays, Relay-Socket and Surface Mount.
    Image of Product. Front orientation. Relay Sockets. Weatherproof Vehicle Relays, Sockets with Crimp- On Terminals.
    Image of Product. Front orientation. Relay Sockets. Weatherproof Vehicle Relays, Sockets with Wire Leads.

    Relay-Socket Mount

    Relay-Socket and

    Surface Mount

    Sockets

    with

    Crimp- On

    Terminals

    Sockets with Wire Leads

    An extended housing shields the terminals on these relays from weather. They're also rated IP54—when they're plugged into the relay socket, they're sealed to keep splashing water, like rain, from getting inside. They handle high starting (inrush) currents that often occur when turning on a vehicle. To prevent damage to sensitive equipment, these relays will partially suppress a momentary surge in voltage when the relay switches off. They’ll take a voltage spike of 300V to 500V and bring it down to 100V.
    Surface Mount—Relays for surface mounting have a tab for added security in high-vibration applications.
    Vehicle Relays
    Sockets with
    Crimp- On Terminals
    Sockets with
    Wire Leads
    Switching Current @ Voltage
    No. of
    Terminals
    Input Voltage,
    V DC
    Off (Normally Open)
    Circuit Position
    On (Normally Closed)
    Circuit Position
    Max. Switching
    Voltage, V DC
    Max. Starting
    Current, amp
    Control Current,
    mA
    Surge Suppression
    Coverage
    Ht.
    Wd.
    Dp.
    Quick-Disconnect
    Tab Wd.
    Features
    Each
    Each
    Each
    Relay-Socket Mount
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    51240 amp @ 12V DC20 amp @ 12V DC18150114Partial1.4"1.4"1.8"0.11"Extended Housing9672K302000000———09672K304000000
    51240 amp @ 12V DC20 amp @ 12V DC18150155Partial1.4"1.4"1.8"0.25"Extended Housing9672K301000008228K190000008228K1500000
     
    Relay-Socket and Surface Mount
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    51240 amp @ 12V DC20 amp @ 12V DC18150114Partial1.4"1.4"1.8"0.11"Extended Housing9672K30300000———09672K30400000
    51240 amp @ 12V DC20 amp @ 12V DC18150138Partial1.4"1.4"1.8"0.25"Extended Housing9672K44000008228K19000008228K1500000
    52420 amp @ 24V DC10 amp @ 24V DC40120107Partial1.4"1.4"1.8"0.25"Extended Housing9672K35000008228K19000008228K4400000
     

    Solid State Vehicle Relays

    Image of Product. Front orientation. Contains Annotated. Vehicle Relays. Solid State Vehicle Relays.
    Image of Product. Front orientation. Relay Sockets. Solid State Vehicle Relays, Sockets with Crimp- On Terminals.
    Image of Product. Front orientation. Relay Sockets. Solid State Vehicle Relays, Sockets with Wire Leads.

    Sockets with

    Crimp- On

    Terminals

    Sockets with Wire

    Leads

    With no moving parts, these solid state relays require less maintenance and last longer, switch faster, and are quieter than mechanical relays. They can handle high starting (inrush) currents. The blade terminals meet ISO 8092-1 dimensions, ensuring they are compatible with the electrical connections in road vehicles you need to maintain or repair. Also known as ISO relays or automotive relays.
    Vehicle Relays
    Sockets with
    Crimp- On Terminals
    Sockets with
    Wire Leads
    No. of
    Terminals
    Input Voltage,
    V DC
    Switching Current
    @ Voltage
    Max. Switching
    Voltage, V DC
    Max. Starting
    Current, amp
    Control Current,
    mA
    Ht.
    Wd.
    Dp.
    Quick-Disconnect
    Tab Wd.
    Each
    Each
    Each
    Relay-Socket Mount
     
    1 Circuit Controlled with 1 Off—SPST-NO
    41220 amp @ 12V DC1680101.1"1.1"1"0.25"9672K210000008228K42000008228K12000000
     