McMaster-Carr logo
    Filter by
    NEMA Type
    Industrial Info Compare
    Output Connection NEMA Type
    Industrial Info Compare
    Performance
    Input Connection NEMA Type
    Industrial Info Compare
    Electrical Connection
    Input Voltage
    Industrial Info Snippet
    Output Voltage
    Industrial Info Snippet
    Full Load Run Time
    Half Load Run Time
    Specifications Met
    Mounting Location
    Number of Outlets
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Height
    Width
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    3 Products

    Uninterruptible Backup Power Supplies

    Image of Product. Front orientation. Backup Power Supplies. Uninterruptible Backup Power Supplies.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15.
    Image of Specification. NEMA 5-20 Plug. Front orientation. NEMA 5-20.
    Image of Specification. NEMA 5-15 Socket. Front orientation. 5-15.

    NEMA

    5-15

    Plug

    NEMA

    5-20

    Plug

    NEMA

    5-15

    Socket

    Image of Specification. NEMA 5-20 Socket. Front orientation. NEMA 5-20.
    Image of Specification. NEMA L5-20 Socket. Front orientation. NEMA L5-20.

    NEMA

    5-20

    Socket

    NEMA

    L5-20

    Socket

    Protect sensitive and critical electronic equipment—these uninterruptible power supplies (UPS) do not suffer a loss of power when switching from your power source to the UPS during an outage. They also protect against frequency variation and waveform distortion. All have USB and DB9 connections with cords so you can save data and safely shut down an unattended computer during outages. Choose a power output that is equal to or greater than the power your equipment requires.
    Output
    Run
    Time, min.
    Input
    NEMA Plugs
    Input Voltage
    Range, V AC
    Power
    Current,
    amp
    Voltage,
    V AC
    Voltage
    Accuracy
    Half
    Load
    Full
    Load
    Type
    Connection
    No. of
    Blades
    Output Connection
    NEMA Type
    No. of
    Outlets
    Ht.
    Wd.
    Dp.
    Specs.
    Met
    Each
    100 to 1201,000 VA/900 W9.1120±1%18.26.35-15
    Straight Blade35-15
    83.5"17.4"17.8"UL 177870485K31000000000
    100 to 1201,500 VA/1,350 W12.5120±1%16.55.85-15
    Straight Blade35-15
    83.5"17.4"17.8"UL 177870485K3200000000
    100 to 1202,200 VA/1,800 W18.3120±1%20.27.75-20
    Straight Blade35-20
    L5-20
    6
    1
    3.5"17.4"23.9"UL 177870485K2400000000