    14 Products

    Uninterruptible Backup Power Supplies

    Image of Product. Front orientation. Backup Power Supplies. Uninterruptible Backup Power Supplies.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15.
    Image of Specification. NEMA 5-20 Plug. Front orientation. NEMA 5-20.
    Image of Specification. NEMA 5-15 Socket. Front orientation. 5-15.
    Image of Specification. NEMA 5-20 Socket. Front orientation. NEMA 5-20.
    Image of Specification. NEMA L5-20 Socket. Front orientation. NEMA L5-20.

    NEMA

    5-15

    Plug

    NEMA

    5-20

    Plug

    NEMA

    5-15

    Socket

    NEMA

    5-20

    Socket

    NEMA

    L5-20

    Socket

    Protect sensitive and critical electronic equipment—these uninterruptible power supplies (UPS) do not suffer a loss of power when switching from your power source to the UPS during an outage. They also protect against frequency variation and waveform distortion. All have USB and DB9 connections with cords so you can save data and safely shut down an unattended computer during outages. Choose a power output that is equal to or greater than the power your equipment requires.
    Output
    Run
    Time, min.
    Input
    NEMA Plugs
    Input Voltage
    Range, V AC
    Power
    Current,
    amp
    Voltage,
    V AC
    Voltage
    Accuracy
    Half
    Load
    Full
    Load
    Type
    Connection
    No. of
    Blades
    Output Connection
    NEMA Type
    No. of
    Outlets
    Ht.
    Wd.
    Dp.
    Specs.
    Met
    Each
    100 to 1271,000 VA/900 W9.1120±2%144.85-15
    Straight Blade35-15
    63.5"17.5"12.5"UL 177870485K31000000000
    100 to 1271,500 VA/1,350 W12.5120±2%144.25-15
    Straight Blade35-15
    63.5"17.5"18.5"UL 177870485K3200000000
    100 to 1272,200 VA/1,800 W15120±2%1245-20
    Straight Blade35-20
    L5-20
    6
    1
    3.5"17.5"19"UL 177870485K2400000000

    Backup Power Supplies for Facility Lights

    Backup Power Supplies
    Image of Product. Back orientation. Backup Power Supplies. Backup Power Supplies for Facility Lights, Backup Power Supplies.
    Turn your facility lights into emergency lights—no need for generators or separate backup lights. Also known as battery inverters, these power supplies detect outages and shift your lights to battery power. To comply with UL 924 and help you meet NFPA standards, they activate your lights at full brightness for at least 90 minutes, even if they’re off or dimmed. A low-voltage disconnect extends the life of the battery by switching it off before it’s fully drained.
    An LED indicator tells you whether your lights are using primary or backup power. The indicator also tells you when these power supplies require maintenance. They have a manual test switch, so you can test them without disrupting the power.
    If you have more than one circuit, you’ll need to add a relay to bypass dimmers and on/off controls across circuits. You can also wire these relays to your fire alarm. Pull the alarm to activate lights to full brightness during emergencies, even without an outage. Also known as automatic load control relays.
    Maximum Recommended Power—Maximum recommended power is the total wattage of connected devices that these power supplies can support.
    Cannot Be Sold To—Power supplies that cannot be sold to the listed areas are restricted due to local energy efficiency requirements.
    Overall
    Mounting
    Holes
    Housing
    Wattage,
    W
    Max. Recommended
    Power, W
    Input Voltage,
    V AC
    Output Voltage,
    V AC
    Lg.
    Ht.
    Wd.
    Battery
    Test Type
    Run Time,
    hr.
    Trip Time,
    sec.
    For Conduit
    Trade Size
    Mounting Hardware
    Included
    No.
    of
    Dia.
    Material
    Color
    Temp.,
    ° F
    Features
    Specifications Met
    Cannot Be Sold To
    Each
    3535120 to 277120, 27719 7/8"2 3/4"2 7/8"Manual1.55No45/32"SteelGray32 to 120Remote Test Switch and LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL Listed8197N260000000
    5050120 to 277120, 27722 1/2"2 3/4"3"Manual1.55No45/32"SteelGray32 to 120Remote Test Switch and LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL Listed8197N21000000
    125125120 to 277120, 27723 1/8"11 3/4"4 1/2"Manual1.50.051/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL ListedCanada8197N125000000
    125125120 to 277120, 27723 1/8"11 3/4"4 1/2"Manual1.50.051/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL ListedCalifornia8197N122000000
    250250120 to 277120, 27719 1/8"11 5/8"7 5/8"Manual1.511/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL Listed8197N12600000000
    375337120 to 277120, 27723"17 3/4"8 1/4"Manual1.511/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL ListedCalifornia, Canada8197N12300000000
    550495120 to 277120, 27723"17 3/4"8 1/4"Manual1.511/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL ListedCalifornia, Canada8197N12400000000
    550550120 to 277120, 27719 3/4"22"11"Manual1.511/2
    No21/2"SteelWhite70 to 85Test Switch, LED Indicator, Low-Voltage DisconnectNFPA 70, NFPA 101 7.8.1.2.2, UL 924, UL ListedCanada8197N12700000000
    Relays
    Image of Product. Back orientation. Backup Power Supplies. Backup Power Supplies for Facility Lights, Relays, Unthreaded Through-Hole Mount.
    Image of Product. Front orientation. Backup Power Supplies. Backup Power Supplies for Facility Lights, Relays, Fastener Mount.

    Unthreaded

    Through-Hole

    Mount

    Fastener Mount

    Relays have an LED indicator that tells you if your lights are using primary or backup power and when these relays require maintenance. They also have a test switch to make sure the system is working.
    Unthreaded Through-Hole Mount—Relays that mount into an unthreaded through hole install into knockouts in junction boxes and light fixtures.
    Fastener Mount—Fastener-mount relays are ideal when space is tight or you want to hide your relay. They fit inside a ballast channel to keep everything contained within your fixture housing.
    Overall
    Mounting
    Holes
    Wire
    Lead
    Conduit
    Connection
    Input Voltage,
    V AC
    Output Voltage,
    V AC
    Control Current,
    mA
    Switching
    Current, amp
    Max. Switching
    Voltage, V AC
    Mechanical
    Life Cycles
    Trip Time,
    sec.
    Ht.
    Wd.
    Dp.
    Battery
    Test Type
    Mounting Fasteners
    Included
    No.
    of
    Dia.
    Lg.
    No.
    of
    Gender
    Trade
    Size
    Thread
    Type
    Temp.,
    ° F
    Features
    Enclosure
    Rating
    Specifications Met
    Each
    1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO
     
    Unthreaded Through-Hole Mount
    120 to 277120 to 2771182027710,000,0000.0184"4"1 3/4"ManualYes40.19"16"6Male1/2
    NPT
    -30 to 140Test Switch, LED IndicatorNEMA 1
    NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL Listed, CE Marked8197N120000000
     
    Fastener Mount
    120 to 277120 to 2771181027710,000,0000.0181 3/4"4 3/4"1 1/4"ManualNo20.19"16"10-30 to 140Test Switch, LED IndicatorNEMA 1
    NFPA 101 7.8.1.2.2, UL 924, UL Listed, C-UL Listed, CE Marked8197N13000000
     