About Replacing a Ballast
More
Electronic Ballasts for Tubular Fluorescent Light Bulbs

In addition to being more energy-efficient than magnetic ballasts, these electronic ballasts are lighter and quieter. Ballasts that can operate multiple bulbs may have more wires than you need. Cover unused wires with a wire nut.
Programmed-start ballasts provide the longest bulb life, but they take longer than instant- and rapid-start ballasts to turn on. They are often used with motion-sensing light controls.
For Bulb Trade No. | For No. of Bulbs | For Bulb Wattage | Voltage | No. of Wire Leads | Light Setting | Lg. | Wd. | Dp. | Min. Start Temp., °F | Specifications Met | Each | |
Programmed Start | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tubular T5 Bulbs | ||||||||||||
F14T5, F21T5, F28T5, F35T5 | 1, 2 | 14W, 21W, 28W, 35W | 120V AC/277V AC | 8 | Not Dimmable | 9 1/2" | 1 3/8" | 1" | 0° | UL Listed | 0000000 | 000000 |
FP54T5/HO, FPC55, FT55DL, L58T8 | 2 | 54W | 120V AC/120V DC/277V AC/277V DC | 11 | Dimmable | 16 3/4" | 1 3/4" | 1" | 50° | UL Listed | 0000000 | 000000 |
For Tubular T5/HO Bulbs | ||||||||||||
F24T5/HO, F39T5/HO, FP24/HO, FP39/HO | 1, 2 | 24W, 39W | 120V AC/120V DC/277V AC/277V DC | 8 | Not Dimmable | 14 1/4" | 1 1/4" | 7/8" | -20° | UL Listed | 0000000 | 00000 |
F54T5/HO | 3, 4 | 54W | 120V AC/277V AC | 15 | Not Dimmable | 16 3/4" | 1 3/4" | 1 1/4" | -20° | UL Listed | 0000000 | 00000 |
F54T5/HO, FP54/HO | 1, 2 | 54W | 120V AC/120V DC/277V AC/277V DC | 8 | Not Dimmable | 16 3/4" | 1 1/4" | 1" | -20° | UL Listed | 00000000 | 00000 |
Magnetic Ballasts for Tubular Fluorescent Light Bulbs

These ballasts are often found in older installations. Ballasts that can operate multiple bulbs may have more wires than you need. Cover unused wires with a wire nut.
Preheat ballasts take several seconds to turn on and require a starter.
Ballasts that cannot be sold to Canada do not meet local efficiency standards.
Ballasts | Starters | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Bulb Trade No. | For No. of Bulbs | For Bulb Wattage | Voltage | No. of Wire Leads | Light Setting | Lg. | Wd. | Dp. | Min. Start Temp., °F | Specifications Met | Cannot Be Sold To | Each | Each | ||
Preheat Start | |||||||||||||||
For Tubular T5 Bulbs | |||||||||||||||
F4T5, F6T5, F8T5 | 1 | 4W, 6W, 8W | 120V AC | 2 | Not Dimmable | 3 1/8" | 1 3/8" | 1 7/8" | 50° | UL Listed | Canada | 00000000 | 000000 | 000000 | 00000 |