About Hazardous Location Environmental Ratings
More
About Brightness
More
About Light Appearance
More
Plug-In Emergency Backup Lights



No hardwiring required—these backup lights plug into a standard outlet. They kick on when the power goes out to light the path toward exits. Their battery generates at least 90 minutes of power in compliance with UL 924 standards for backup lights. A low-voltage disconnect extends the life of the battery by switching it off before it’s fully drained. Direct light where it’s needed by angling the adjustable heads.
All have a manual-test switch that lets you verify the battery and heads are working. Lights with automatic battery testing run a self-check once a month. An indicator tells you if they need maintenance.
Style A and B lights are compatible with add-on heads. Run wiring between add-on heads and your backup light to extend lighting into stairwells, exits, and other remote areas. The greater the wattage of the add-on heads—and the more of them you use—the more they’ll reduce your light’s run time. Maximum wattage for add-on heads refers to the total wattage of add-ons you can use without pushing your light’s run time below 90 minutes.
Maximum distance between lights represents how far you can space out two lights without creating a dark zone.
Lights | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Holes | Replacement Batteries | |||||||||||||||||||
| Style | Brightness, lumens | Max. Distance Between Lights, ft. | Battery Test Type | Wd. | Ht. | Dp. | Plug Type | Cord Lg., ft. | Voltage | Output Voltage | Max. Wattage for Add-On Heads | Backup Battery Life, hrs. | Mounting Hardware Included | No. of | Dia. | Temp. Range, °F | Specifications Met | Each | Each | ||
| A | 600 | 50 | Manual | 14 1/2" | 6" | 4 1/4" | Three Prong | 3 | 120V AC | 6V DC | 6W | 3 | No | 2 | 1/8" | 60° to 80° | UL 924, UL Listed, City of Chicago Approved, New York City Approved | 000000000 | 0000000 | 00000000 | 000000 |
| B | 800 | 50 | Manual | 13 1/2" | 11 5/8" | 4 3/8" | Three Prong | 3 | 120V AC | 6V DC | 8W | 5 | No | 2 | 3/16" | 60° to 80° | UL 924, City of Chicago Approved, New York City Approved | 000000000 | 000000 | 00000000 | 00000 |
| C | 1,100 | 125 | Manual, Automatic | 12 1/8" | 5 1/2" | 3 7/8" | Two Prong | 3 | 120V AC | __ | __ | 2 | Yes | 4 | 3/16" | 0° to 150° | UL 924, UL Listed | 00000000 | 000000 | 000000 | 00 |
Emergency Backup Lights








When the power goes out, these lights turn on. They have adjustable heads that illuminate the path toward exits during outages. Rated UL 924, their battery provides at least 90 minutes of light. A low-voltage disconnect means the battery shuts off just before it’s fully drained, prolonging its overall lifespan. Lights cannot be sold to the listed areas due to energy efficiency regulations.
All have a manual-test switch that lets you verify the battery and heads are working. Lights with automatic battery testing run a self-check once a month. An indicator tells you if they need maintenance.
Style D-G lights are compatible with add-on heads. Run wiring between add-on heads and your backup light to extend lighting into stairwells, exits, and other remote areas. The greater the wattage of the add-on heads—and the more of them you use—the more they’ll reduce your light’s run time. Maximum wattage for add-on heads refers to the total wattage of add-ons you can use without pushing your light’s run time below 90 minutes.
Lights for use in damp locations withstand humid and moist conditions.
Maximum distance between lights represents how far you can space out two lights without creating a dark zone.
Lights | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Holes | Replacement Batteries | |||||||||||||||||||
| Style | Brightness, lumens | Max. Distance Between Lights, ft. | Output Voltage | Max. Wattage for Add-On Heads | Battery Test Type | Wd. | Ht. | Dp. | Voltage | Backup Battery Life, hrs. | Mounting Hardware Included | No. of | Dia. | Temp. Range, °F | Environment | Specifications Met | Cannot Be Sold To | Each | Each | ||
| A | 200 | Not Rated | __ | __ | Manual | 11" | 4 1/2" | 2 3/4" | 120-277V AC | 1 1/2 | Yes | 2 | 3/16" | 32° to 100° | __ | UL 924, UL Listed, C-UL Listed | __ | 00000000 | 000000 | 000000 | 00 |
| B | 220 | 35 | __ | __ | Manual | 9 3/4" | 4 3/4" | 3 1/8" | 120V AC, 277V AC | 1 1/2 | No | 4 | 3/16" | 50° to 100° | Damp Location | UL 924, UL Listed | __ | 0000000 | 00000 | 000000 | 00 |
| C | 300 | 25 | __ | __ | Manual | 9 3/8" | 4 3/4" | 2 7/8" | 120V AC, 277V AC | 1 1/2 | Yes | 2 | 3/16" | 32° to 120° | Damp Location | UL 924, UL Listed | __ | 00000000 | 00000 | 000000 | 00 |
| C | 300 | 25 | __ | __ | Manual, Automatic | 9 3/8" | 4 3/4" | 2 7/8" | 120V AC, 277V AC | 1 1/2 | Yes | 2 | 3/16" | 32° to 120° | Damp Location | UL 924, UL Listed | __ | 00000000 | 00000 | 000000 | 00 |
| D | 600 | 60 | 6V DC | 6W | Manual | 14 1/2" | 6" | 4 1/4" | 120V AC, 277V AC | 3 | No | 2 | 3/16" | 60° to 80° | __ | UL 924, UL Listed, City of Chicago Approved, New York City Approved | __ | 00000000 | 00000 | 00000000 | 000000 |
| E | 600 | 60 | 4.8V DC | 4W | Manual, Automatic | 12 3/8" | 10 1/4" | 2 1/4" | 120V AC, 277V AC | 1 1/2 | No | 4 | 3/16" | 32° to 100° | Damp Location | UL 924, UL Listed, City of Chicago Approved, New York City Approved | __ | 0000000 | 000000 | 000000 | 00 |
| F | 800 | 70 | 6V DC | 22W | Manual, Automatic | 13 3/8" | 11 5/8" | 4 3/8" | 120V AC, 277V AC | 5 | No | 2 | 3/16" | 60° to 80° | __ | UL 924, UL Listed, City of Chicago Approved, New York City Approved | CA, Canada | 00000000 | 000000 | 00000000 | 00000 |
| F | 800 | 70 | 9.6V DC | 22W | Manual, Automatic | 13 3/8" | 11 5/8" | 4 3/8" | 120V AC, 277V AC | 5 | No | 2 | 3/16" | 0° to 150° | __ | UL 924, City of Chicago Approved, New York City Approved | __ | 0000000 | 000000 | 0000000 | 000000 |
| G | 800 | 50 | 6V DC | 90W | Manual, Automatic | 15 1/2" | 17 1/4" | 8" | 120V AC, 277V AC | 9 | No | 2 | 1/4" | 60° to 80° | __ | UL 924, UL Listed, City of Chicago Approved, New York City Approved | CA, Canada | 00000000 | 000000 | 00000000 | 000000 |
| H | 1,100 | 125 | __ | __ | Manual, Automatic | 12 1/8" | 5 1/2" | 3 1/2" | 120V AC, 277V AC | 2 | Yes | 2 | 3/16" | 0° to 150° | Damp Location | UL 924, UL Listed | __ | 00000000 | 000000 | 000000 | 00 |
Emergency-Light Conversion Kits for Fluorescent Lights

Connect the battery pack to your existing fluorescent light to convert it into an emergency backup light. They include a test switch to check that the bulbs and battery are working properly.
Kits that cannot be sold to the regions listed are resitricted by local energy efficiency requirements.
Overall | Mounting Holes | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| For Use With | Lg. | Wd. | Ht. | Voltage | Brightness, Lumens | Run Time, hrs. | Mounting Hardware Included | No. of | Dia. | Cannot Be Sold To | Each | |
For CFL and Fluorescent Bulbs | ||||||||||||
| One 4-Pin Twin-Tube CFL Bulb One T8 Fluorescent Bulb (2 ft. to 4 ft.) One T8 U-Shaped Fluorescent Bulb One T9 Circline Fluorescent Bulb One T12 Fluorescent Bulb (2 ft. to 4 ft.) One T12 U-Shaped Fluorescent Bulb | 9 1/2" | 2 1/2" | 1 1/2" | 120V AC, 208V AC, 240V AC, 277V AC | 500 | 1.5 | No | 2 | 5/16" | CA, OR | 0000000 | 0000000 |
| One T8 Fluorescent Bulb (5 ft.) One 4-Pin Twin-Tube CFL Bulb One 4-Pin Quad-Tube CFL Bulb One T5 Fluorescent Bulb (2 ft. to 4 ft.) One T5/HO Fluorescent Bulb (2 ft. to 4 ft.) One or Two T8 Fluorescent Bulbs (2 ft. to 4 ft.) One or Two T8 U-Shaped Fluorescent Bulbs One T9 Circline Fluorescent Bulb One or Two T12 Fluorescent Bulbs (2 ft. to 4 ft.) One T12 Fluorescent Bulb (5 ft. to 8 ft.) One T12/HO Fluorescent Bulb (2 ft. to 8 ft.) One T12/VHO Fluorescent Bulb (2 ft. to 8 ft.) One T12 U-Shaped Fluorescent Bulb | 9 3/8" | 2 1/4" | 1 1/4" | 120V AC, 208V AC, 240V AC, 277V AC | 600 | 1.5 | No | 2 | 5/16" | CA, OR | 0000000 | 000000 |
| One 4-Pin Twin-Tube CFL Bulb One or Two 4-Pin Quad-Tube CFL Bulbs One T5 Fluorescent Bulb (2 ft. to 4 ft.) One T5/HO Fluorescent Bulb (2 ft. to 4 ft.) One or Two T8 Fluorescent Bulbs (2 ft. to 4 ft.) One or Two T8 Fluorescent Bulbs (5 ft. to 8 ft.) One or Two T8 U-Shaped Fluorescent Bulbs One T9 Circline Fluorescent Bulb One or Two T12 Fluorescent Bulbs (2 ft. to 4 ft.) One or Two T12 Fluorescent Bulbs (5 ft. to 8 ft.) One T12/HO Fluorescent Bulb (2 ft. to 8 ft.) One T12/VHO Fluorescent Bulb (2 ft. to 8 ft.) One or Two T12 U-Shaped Fluorescent Bulbs | 13 3/8" | 2 1/4" | 1 1/4" | 120V AC, 208V AC, 240V AC, 277V AC | 1,400 | 1.5 | No | 2 | 5/16" | __ | 0000000 | 000000 |
Explosion-Proof Emergency Backup Lights

Light the path toward exits where combustible gases and dust are constantly present—the enclosure on these lights contains sparks and flashes to prevent a reaction with nearby hazards. They’re often found in extreme environments, such as refineries and chemical plants. Because they’re totally sealed, these lights meet IP66 to withstand dust and washdowns. They’re also UL marine listed to resist corrosion from salt water. Rated IK10—the highest level of impact protection—they stand up to wear and tear.
Adjust the heads toward your walkways, and they’ll kick on when the power goes out. With a battery life of 3 hours, they meet UL 924 standards for generating at least 90 minutes of light. Press the test switch to check if the heads or battery require maintenance.
Maximum distance between lights represents how far you can space out two lights without creating a dark zone.
Overall | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Brightness, lumens | Max. Distance Between Lights, ft. | Battery Test Type | Wd. | Ht. | Dp. | Voltage | Batteries Included | Backup Battery Life, hrs. | Mounting Hardware Included | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
| 1,300 | 65 | Manual | 12" | 12 5/8" | 6 1/2" | 120-277V AC | Yes | 3 | Yes | -40° to 140° | NEC Class I Divisions 1, 2 Groups C, D NEC Class I Division 2 Groups A, B NEC Class II Divisions 1, 2 Groups E, F, G IP66 IK10 | UL 924, UL Marine Listed, ETL Listed, C-ETL Listed | 00000000 | 000000000 |
Outdoor Emergency Backup Lights



Illuminate outdoor exit paths and emergency assembly areas during power outages. Enclosed to withstand the elements, these lights are UL listed to resist rain, snow, and humidity. Their battery generates at least 90 minutes of power in compliance with UL 924 standards for backup lights. A low-voltage disconnect extends the life of the battery by switching it off before it’s fully drained. Direct light where it's needed by angling the adjustable heads.
All have a manual-test switch that lets you verify the battery and heads are working. Lights with automatic battery testing run a self-check once a month. An indicator tells you if they need maintenance.
Lights with 3 hrs. of backup battery life are compatible with add-on heads. Run wiring between add-on heads and your backup light to extend lighting into stairwells, exits, and other remote areas. The greater the wattage of the add-on heads—and the more of them you use—the more they’ll reduce your light’s run time. Maximum wattage for add-on heads refers to the total wattage of add-ons you can use without pushing your light’s run time below 90 minutes.
Maximum distance between lights represents how far you can space out two lights without creating a dark zone.
Overall | Mounting Holes | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Style | Brightness, lumens | Max. Distance Between Lights, ft. | Battery Test Type | Wd. | Ht. | Dp. | Voltage | Output Voltage | Max. Wattage for Add-On Heads | Batteries Included | Mounting Hardware Included | No. of | Dia. | Temp. Range, °F | Specifications Met | Each | |
1 1/2 hrs. Backup Battery Life | |||||||||||||||||
| A | 240 | 35 | Manual | 9" | 12" | 3 1/8" | 120V AC, 277V AC | __ | __ | Yes | No | 4 | 5/16" | 0° to 150° | UL 924, UL Listed | 00000000 | 000000 |
| B | 300 | 50 | Manual, Automatic | 7 7/8" | 8" | 2 1/4" | 120V AC, 277V AC | __ | __ | Yes | Yes | 4 | 3/16" | 32° to 100° | UL 924, UL Listed, City of Chicago Approved | 0000000 | 000000 |
| C | 400 | 50 | Manual | 12 1/4" | 4 7/8" | 4 1/4" | 120V AC, 277V AC | __ | __ | Yes | Yes | 10 | 3/16" | 32° to 100° | UL 924, UL Listed, C-UL Listed | 00000000 | 00000 |
3 hrs. Backup Battery Life | |||||||||||||||||
| A | 240 | 35 | Manual | 9" | 12" | 3 1/8" | 120V AC, 277V AC | 9.6V DC | 3W | Yes | No | 4 | 5/16" | 0° to 150° | UL 924, UL Listed | 0000000 | 000000 |
Washdown Emergency Backup Lights




A gasket seals the enclosure of these backup lights from washdowns. Adjust the heads toward your walkways—they kick on when the power goes out, lighting the path toward exits. Rated UL 924, their battery provides at least 90 minutes of light. A low-voltage disconnect automatically shuts off the battery before it's fully drained, prolonging its overall lifespan. All are dust-tight.
Lights cannot be sold to the listed areas due to energy efficiency regulations.
Lights rated IP65 withstand low-pressure washdowns, like spray from a garden hose. For high-pressure or corrosive washdowns, choose a light rated IP66 or NEMA 4X. Those rated NEMA 13 can withstand light sprays of oil and coolant.
Lights that are rated NSF/ANSI 2 or ETL sanitation marked are approved for use in food processing plants and industrial kitchens.
Choose lights with a battery heater for cold environments such as refrigerated warehouses and outdoor garages.
All have a manual-test switch that lets you verify the battery and heads are working. Lights with automatic battery testing run a self-check once a month. An indicator tells you if they need maintenance.
Style B and D lights are compatible with add-on heads. Run wiring between add-on heads and your backup light to extend lighting into stairwells, exits, and other remote areas. The greater the wattage of the add-on heads—and the more of them you use—the more they’ll reduce your light’s run time. Maximum wattage for add-on heads refers to the total wattage of add-ons you can use without pushing your light’s runtime below 90 minutes.
Maximum distance between lights represents how far you can space out two lights without creating a dark zone.
Lights | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Holes | Replacement Batteries | |||||||||||||||||||
| Style | Brightness, lumens | Max. Distance Between Lights, ft. | Output Voltage | Max. Wattage for Add-On Heads | Battery Test Type | Wd. | Ht. | Dp. | Voltage | Backup Battery Life, hrs. | Mounting Hardware Included | No. of | Dia. | Temp. Range, °F | Environmental Rating | Specifications Met | Cannot Be Sold To | Each | Each | ||
Lights | |||||||||||||||||||||
| A | 220 | 35 | __ | __ | Manual, Automatic | 12" | 5 3/4" | 4 1/4" | 120-277V AC | 1 1/2 | Yes | 2 | 3/16" | 0° to 120° | NEMA 4X | UL 924, UL Listed | __ | 00000000 | 000000 | 000000 | 00 |
| A | 1,450 | 115 | __ | __ | Manual, Automatic | 12" | 5 3/4" | 4 1/4" | 120-277V AC | 1 1/2 | Yes | 2 | 3/16" | 32° to 120° | NEMA 4X | UL 924, UL Listed | __ | 00000000 | 00000 | 000000 | 00 |
| B | 600 | 60 | 4.8V DC | 4W | Manual, Automatic | 10 7/8" | 12" | 6" | 120V AC, 277V AC | 1 1/2 | No | 4 | 5/16" | 32° to 100° | NEMA 4X, IP66 | UL 924, UL Listed | __ | 0000000 | 000000 | 000000 | 00 |
| B | 800 | 50 | 6V DC | 8W | Manual | 9 1/2" | 19 5/8" | 6 3/4" | 120V AC, 277V AC | 3 | No | 4 | 1/4" | 60° to 80° | NEMA 4X, NEMA 13 | UL 924, UL Listed, ETL Sanitation Marked, NSF/ANSI 2 Splash Zone | CA, Canada | 00000000 | 000000 | 00000000 | 000000 |
| B | 800 | 50 | 9.6V DC | 8W | Manual, Automatic | 9 1/2" | 17" | 5 1/2" | 120V AC, 277V AC | 3 | No | 4 | 5/16" | 60° to 80° | NEMA 4X, NEMA 13 | UL 924, ETL Sanitation Marked, NSF/ANSI 2 Splash Zone | __ | 0000000 | 000000 | 0000000 | 00000 |
| C | 930 | 70 | __ | __ | Manual, Automatic | 17" | 6 1/2" | 4 1/2" | 120V AC, 277V AC | 1 1/2 | Yes | 2 | 3/16" | 32° to 100° | IP65 | UL 924, UL Listed, ETL Sanitation Marked, NSF/ANSI 2 Splash Zone | CA | 00000000 | 000000 | 00000000 | 00000 |
| D | 1,290 | 80 | 12V DC | 28W | Manual, Automatic | 16 1/4" | 6" | 7 1/2" | 120V AC, 277V AC | 4 | No | 4 | 3/16" | 32° to 100° | NEMA 4X, IP66 | UL 924, UL Listed, ETL Sanitation Marked, NSF/ANSI 2 Splash Zone | CA | 00000000 | 000000 | 000000000 | 00000 |
| D | 1,380 | 80 | 6V DC | 8W | Manual, Automatic | 16 1/4" | 6" | 7 1/2" | 120V AC, 277V AC | 2 | No | 4 | 3/16" | 32° to 100° | NEMA 4X, IP66 | UL 924, UL Listed, ETL Sanitation Marked, NSF/ANSI 2 Splash Zone | CA | 00000000 | 000000 | 000000000 | 00000 |
Lights with Battery Heater | |||||||||||||||||||||
| B | 800 | 50 | 6V DC | 8W | Manual | 9 1/2" | 16 1/2" | 6 3/4" | 120V AC, 277V AC | 3 | No | 4 | 1/4" | 10° to 80° | NEMA 4X, NEMA 13 | UL 924, UL Listed | CA, Canada | 00000000 | 000000 | 00000000 | 00000 |
| B | 800 | 50 | 9.6V DC | 8W | Manual, Automatic | 9 1/2" | 17" | 5 1/2" | 120V AC, 277V AC | 3 | No | 4 | 5/16" | 0° to 150° | NEMA 4X, NEMA 13 | UL 924 | __ | 0000000 | 000000 | 0000000 | 00000 |
| D | 1,290 | 80 | 12V DC | 28W | Manual, Automatic | 16 1/4" | 6" | 7 1/2" | 120V AC, 277V AC | 4 | No | 4 | 3/16" | 0° to 100° | NEMA 4X, IP66 | UL 924, UL Listed, ETL Sanitation Marked, NSF/ANSI 2 Splash Zone | CA | 00000000 | 000000 | 000000000 | 00000 |
| D | 1,380 | 80 | 6V DC | 8W | Manual, Automatic | 16 1/4" | 6" | 7 1/2" | 120V AC, 277V AC | 2 | No | 4 | 3/16" | 0° to 100° | NEMA 4X, IP66 | UL 924, UL Listed, ETL Sanitation Marked, NSF/ANSI 2 Splash Zone | CA | 00000000 | 000000 | 000000000 | 00000 |
Hazardous Location Emergency Backup Lights

Install these lights in aircraft hangars, gas plants, and other facilities where flammable and combustible gases or dust may be present, such as leaks or ventilation failures. Rated NEC Class I, Division 2, they seal out gases but aren't built to contain explosions. The sealed design also keeps out liquid and dust—they're rated NEMA 4X and IP66 to resist washdowns. An ETL sanitation marking verifies they're safe for use in food environments.
Adjust the heads toward your walkways—they kick on when the power goes out, lighting the path toward exits. Rated UL 924, their battery generates at least 90 minutes of light. A low-voltage disconnect extends the life of the battery by switching it off before it’s fully drained. Once a month, these lights automatically test that the battery and heads are working. An indicator tells you if they need maintenance. They also have a manual switch to test them any time.
Wire these lights to add-on heads to extend lighting into stairwells, exits, and other remote areas. The greater the wattage of the add-on heads—and the more of them you use—the more they’ll reduce your light’s run time. Maximum wattage for add-on heads refers to the total wattage of add-ons you can use without pushing your light’s run time below 90 minutes.
Maximum distance between lights represents how far you can space out two lights without creating a dark zone.
Lights | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Holes | Replacement Batteries | ||||||||||||||||
| Max. Wattage for Add-On Heads | Brightness, lumens | Max. Distance Between Lights, ft. | Battery Test Type | Wd. | Ht. | Dp. | Voltage | Backup Battery Life, hrs. | Mounting Hardware Included | No. of | Dia. | Temp. Range, °F | Environmental Rating | Specifications Met | Each | Each | ||
6V DC Output Voltage | ||||||||||||||||||
| 8W | 1,380 | 80 | Manual, Automatic | 16 1/4" | 6" | 7 1/2" | 120V AC, 277V AC, 347V AC | 2 | No | 4 | 3/16" | 50° to 100° | NEC Class I Division 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 4X IP66 | UL 924, ETL Sanitation Marked, CSA-US Certified, CSA Certified | 000000000 | 0000000 | 000000000 | 000000 |
| 28W | 1,380 | 80 | Manual, Automatic | 16 1/4" | 6" | 7 1/2" | 120V AC, 277V AC, 347V AC | 4 | No | 4 | 3/16" | 50° to 100° | NEC Class I Division 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 4X IP66 | UL 924, ETL Sanitation Marked, CSA-US Certified, CSA Certified | 000000000 | 000000 | 000000000 | 00000 |
12V DC Output Voltage | ||||||||||||||||||
| 28W | 1,290 | 80 | Manual, Automatic | 16 1/4" | 6" | 7 1/2" | 120V AC, 277V AC, 347V AC | 4 | No | 4 | 3/16" | 50° to 100° | NEC Class I Division 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 4X IP66 | UL 924, ETL Sanitation Marked, CSA-US Certified, CSA Certified | 000000000 | 000000 | 000000000 | 00000 |
Recessed Ceiling Emergency Backup Lights


Installed in drop ceilings, these lights are often used in open workspaces where columns and walls are few and far between. Unlike traditional backup lights, they don’t require a vertical surface for mounting. When the power goes out, they kick on, lighting the path toward exits. Direct light where it’s needed by angling the adjustable heads. Their battery generates at least 90 minutes of power in compliance with UL 924 standards for backup lights. A low-voltage disconnect extends the life of the battery by switching it off before it’s fully drained.
Once a month, these lights automatically test that the battery and heads are working. An indicator tells you if they need maintenance. They also have a manual switch that lets you test them any time.
Wire these lights to add-on heads to extend lighting into stairwells, exits, and other remote areas. The greater the wattage of the add-on heads—and the more of them you use—the more they’ll reduce your light’s run time. Maximum wattage for add-on heads refers to the total wattage of add-ons you can use without pushing your light’s run time below 90 minutes.
Maximum distance between lights represents how far you can space out two lights without creating a dark zone.
Lights that cannot be sold to CA are restricted due to energy efficiency regulations.
Lights | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Batteries | ||||||||||||||||
| Brightness, lumens | Max. Distance Between Lights, ft. | Battery Test Type | Wd. | Ht. | Dp. | Voltage | Output Voltage | Max. Wattage for Add-On Heads | Backup Battery Life, hrs. | Temp. Range, °F | Specifications Met | Cannot Be Sold To | Each | Each | |||
| A | 1,140 | 65 | Manual, Automatic | 23 3/4" | 12 3/8" | 4 3/4" | 120-277V AC | 12V DC | 32W | 4 | 50° to 100° | UL 924, UL Listed | CA | 0000000 | 0000000 | 000000000 | 000000 |
| B | 800 | 50 | Manual, Automatic | 10 1/8" | 9 3/4" | 6 3/4" | 120V AC, 277V AC | 9.6V DC | 8W | 3 | 60° to 80° | UL 924, City of Chicago Approved | __ | 0000000 | 000000 | 0000000 | 00000 |
Motion-Sensing Wall Lights

Often used in stairwells and hallways, these lights save energy by only turning on when they sense movement. Once movement stops, they’ll dim or turn off completely—choose your preference with the controls in front. You can also adjust the light duration and sensor range. These lights are DLC (DesignLight Consortium) listed, so they’ve been tested to confirm their energy efficiency.
Choose between a neutral or cool light appearance on the LED driver to match existing lights. To minimize glare, the frosted lens disperses light evenly. It’s also made of polycarbonate to resist impact.
All are UL listed to resist humidity and moisture, so they’ll work in damp locations. Lights with a backup battery shine a 1,000 lumen light for 90 minutes if the power goes out.
Overall | Housing | Mounting Holes | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Lg. | Wd. | Ht. | Brightness, lumens | Wattage | Voltage | Light Appearance | Light Setting | Max. Sensing Distance, ft. | Material | Color | Mounting Hardware Included | No. of | Dia. | Each | |
Built-In LED with Backup Battery | |||||||||||||||
| 24" | 4 7/8" | 5 5/8" | 2,500 3,100 3,630 | 20W 25W 30W | 120-277V AC | Neutral (3,500K), Neutral (4,000K), Cool (5,000K) | Dimmable | 35 | Powder-Coated Steel | White | No | 4 | 3/8" | 00000000 | 0000000 |
| 48" | 4 7/8" | 5 5/8" | 3,750 4,340 5,445 | 30W 35W 45W | 120-277V AC | Neutral (3,500K), Neutral (4,000K), Cool (5,000K) | Dimmable | 35 | Powder-Coated Steel | White | No | 4 | 3/8" | 00000000 | 000000 |
Linear Bay Lights
With more surface area than round bay lights, these fixtures produce softer light with less glare. Use them to replace old fluorescent lights and illuminate large, open areas with high ceilings. Rated for use in damp locations, these lights withstand humidity and moisture.
Lights with a motion sensor turn on when people or vehicles are present. Add a remote (sold separately) to program your sensor’s settings without needing to climb up to the light.
Styles B-D have thermally protected drivers and larger heat sinks than other bay lights, so they’ll last longer at higher temperatures. Their LEDs have a consistent color temperature, which helps maintain a uniform appearance across multiple lights.
Style C can be mounted with the included suspension hardware or mounting brackets (sold separately). The suspension hardware comes with two wire rope slings with hooks and two wire rope clamps. No tools are required for installation—adjust the suspension length and tighten the clamps to secure. Those with a backup battery stay lit for 90 minutes if the power goes out.

Overall | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Style | For Ceiling Ht. | Brightness, lumens | Wattage | Voltage | Light Appearance | Lg. | Wd. | Ht. | Light Setting | Housing Material | Mounting Hardware Included | Specifications Met | Each | |
Wide Beam with Backup Battery | ||||||||||||||
| C | 45'-55' | 32,600 37,000 41,700 | 200W 240W 290W | 120-277V AC | Neutral (4,000K), Cool (4,500K), Cool (5,000K) | 25 7/8" | 17 7/8" | 3 3/8" | Dimmable | Aluminum | Yes | UL-Listed, C-UL Listed, DLC Listed | 00000000 | 0000000 |
| C | 45'-55' | 49,900 57,000 66,100 | 325W 385W 450W | 120-277V AC | Neutral (4,000K), Cool (4,500K), Cool (5,000K) | 42 3/4" | 17 7/8" | 3 3/8" | Dimmable | Aluminum | Yes | UL-Listed, C-UL Listed, DLC Listed | 00000000 | 000000 |

| For Style | Each | |
| C | 00000000 | 000000 |

| For Style | Each | |
| C | 00000000 | 000000 |

| For Style | Lg. | Wd. | Dp. | Material | Each | |
| C | 6" | 4 1/4" | 1 5/8" | Aluminum | 00000000 | 000000 |
Washdown Ceiling Lights
IP or NEMA rated, these lights have a sealed lens to keep dust and moisture out for protection against washdowns. All meet ETL or UL standards for wet locations.
Mount these lights to the ceiling with the included brackets. For lights with mounting V-hooks, you can suspend them from the ceiling with chains (not included).
Styles A-B have a wraparound lens that allows light to shine from the sides as well as the bottom. Lights with a backup battery stay illuminated for at least 90 minutes during a power outage in compliance with UL 924.
IP65 lights withstand light rinses. IP66 lights withstand high-pressure washdowns. NEMA 4X lights withstand corrosive liquids and spraying water—including washdowns.
Lights that meet NSF/ANSI 2 standards are commonly used in food handling and processing areas with splashing liquid.


Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Style | Lg. | Wd. | Ht. | Brightness, lumens | Wattage | Voltage | Electrical Connection Type | Sensor Type | Light Appearance | Light Setting | Mounting Hardware Included | Includes | Environmental Rating | Specifications Met | Each | |
Made Outside the U.S. | ||||||||||||||||
Built-In LED with Backup Battery | ||||||||||||||||
| A | 26 1/4" | 3 5/16" | 3 3/8" | 2,085 2,780 3,475 | 15W 20W 25W | 120-347V AC | Hardwire | __ | Neutral (3,500K), Neutral (4,000K), Cool (5,000K) | Dimmable | Yes | Two V-Hooks | IP66, NEMA 4X | UL Listed, UL 924, DLC Listed, NSF/ANSI 2 Splash Zone | 00000000 | 0000000 |
| A | 50 1/4" | 3 5/16" | 3 3/8" | 4,170 5,560 6,950 | 30W 40W 50W | 120-347V AC | Hardwire | __ | Neutral (3,500K), Neutral (4,000K), Cool (5,000K) | Dimmable | Yes | Two V-Hooks | IP66, NEMA 4X | UL Listed, UL 924, DLC Listed, NSF/ANSI 2 Splash Zone | 00000000 | 000000 |
| A | 98 1/2" | 5 5/16" | 3 3/4" | 9,730 11,120 12,510 | 70W 80W 90W | 120-347V AC | Hardwire | __ | Neutral (3,500K), Neutral (4,000K), Cool (5,000K) | Dimmable | Yes | Two V-Hooks | IP66, NEMA 4X | UL Listed, UL 924, DLC Listed, NSF/ANSI 2 Splash Zone | 00000000 | 000000 |
| B | 49 7/8" | 10 5/16" | 5" | 9,000 11,250 13,500 | 60W 75W 90W | 120-277V AC | Hardwire | Light, Motion | Neutral (3,500K), Neutral (4,000K), Cool (5,000K) | Dimmable | Yes | Two V-Hooks | IP65, NEMA 4X | UL Listed, UL 924, DLC Listed, NSF/ANSI 2 Splash Zone | 00000000 | 000000 |
| B | 49 7/8" | 10 5/16" | 5" | 18,000 22,500 27,000 | 120W 150W 180W | 120-277V AC | Hardwire | Light, Motion | Neutral (3,500K), Neutral (4,000K), Cool (5,000K) | Dimmable | Yes | Two V-Hooks | IP65, NEMA 4X | UL Listed, UL 924, DLC Listed, NSF/ANSI 2 Splash Zone | 00000000 | 000000 |
Made in the U.S. | ||||||||||||||||
Built-In LED with Backup Battery | ||||||||||||||||
| A | 26 1/2" | 6 3/4" | 4 1/4" | 4,300 | 30W | 120-277V AC | Hardwire | __ | Neutral (4,000K) | Dimmable | Yes | __ | IP66 | UL Listed, UL 924, DLC Listed | 00000000 | 000000 |
| A | 26 1/2" | 6 3/4" | 4 1/4" | 4,600 | 30W | 120-277V AC | Hardwire | __ | Cool (5,000K) | Dimmable | Yes | __ | IP66 | UL Listed, UL 924, DLC Listed | 00000000 | 000000 |
| A | 50 1/2" | 6 3/4" | 4 1/4" | 6,200 | 40W | 120-277V AC | Hardwire | __ | Neutral (4,000K) | Dimmable | Yes | __ | IP66 | UL Listed, UL 924, DLC Listed | 00000000 | 000000 |
| A | 50 1/2" | 6 3/4" | 4 1/4" | 6,600 | 40W | 120-277V AC | Hardwire | __ | Cool (5,000K) | Dimmable | Yes | __ | IP66 | UL Listed, UL 924, DLC Listed | 00000000 | 000000 |
| B | 28 1/8" | 7 3/4" | 4 7/8" | 700 1,600 3,000 3,700 | 7W 13W 23W 29W | 120-277V AC | Hardwire | __ | Cool (5,000K) | Dimmable | Yes | __ | IP65 | UL Marine Listed, UL Listed, UL 924, ABS Design Assessed | 00000000 | 000000 |
| B | 53" | 7 5/8" | 4 5/8" | 900 2,500 5,000 6,400 | 8W 19W 39W 49W | 120-277V AC | Hardwire | __ | Cool (5,000K) | Dimmable | Yes | __ | IP65 | UL Marine Listed, UL Listed, UL 924, ABS Design Assessed | 00000000 | 000000 |
Explosion-Proof Ceiling Lights


Contain explosions, sparks, and flashes—the enclosure on these ceiling lights makes them safe to use in NEC Class I and II, Division 1 hazardous locations. They meet NEC hazardous location temperature classifications, so their surface stays cool enough to avoid igniting hazardous gases or dust. Designed to resist corrosion from salt water, they’re also UL marine listed. All lights have adjustable mounting brackets that can rotate 45° in either direction to direct light where you need it.
Style 1 lights are built for harsh environments, like offshore oil rigs. They have been tested to withstand vibration without breaking or shutting down. The mounting bracket matches standard bolt hole patterns.
Lights with a backup battery shine for at least 90 minutes during a power outage to comply with UL 924.
Overall | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Style | Lg. | Wd. | Ht. | Brightness, lumens | Light Appearance | Wattage | Voltage | Housing Material | Housing Color | Mounting Hardware Included | Environmental Rating | NEC Hazardous Location Temperature Classification | Specifications Met | Each | |
Built-In LED with Backup Battery | |||||||||||||||
| 1 | 22 1/2" | 7 3/8" | 6 5/8" | 4,300 | Cool (5,000K) | 33W | 120-277V AC | Epoxy-Coated Aluminum | Gray | No | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIB, IIA IP66 NEMA 4X | T6-T5 (185° - 212° F) | UL Listed, UL 924, C-UL Listed, DLC Listed | 0000000 | 000000000 |
| 1 | 45 3/8" | 7 3/8" | 6 5/8" | 7,600 | Cool (5,000K) | 55W | 120-277V AC | Epoxy-Coated Aluminum | Gray | No | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Zone 1 Groups IIB, IIA IP66 NEMA 4X | T6-T5 (185° - 212° F) | UL Listed, UL 924, C-UL Listed, DLC Listed | 0000000 | 00000000 |
| 2 | 51 1/2" | 12" | 9" | 8,400 | Cool (5,000K) | 80W | 120-277V AC | Aluminum | __ | No | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 | T6-T3B (185° - 329° F) | UL Listed, UL Marine Listed, UL 924, C-UL Listed | 0000000 | 00000000 |
Hazardous Location Exit Signs

Rated NEC Classes I and II, these exit signs are safe to use in areas with flammable or combustible gases, vapors, and dust. Their housing is designed to contain any fire and sparks, so they don’t ignite what’s in your environment. They run at cooler temperatures than traditional exit signs and contain no harmful substances, making them a safer alternative. These signs are often installed in chemical and manufacturing plants.
Resistant to flames, corrosion, and impact, these signs withstand tough conditions in unforgiving environments. The faceplate is made of tempered glass to protect against impact and vibration. Plus, an aluminum body with an epoxy finish enhances corrosion and impact resistance. It also makes the surface easy to clean.
The edges of these signs are always illuminated for high visibility. The “Exit” portion has two operating modes: it can remain lit at all times or light up only during a power outage. A backup battery keeps these signs working for up to three hours during a power outage. For reliability, they have surge-protected circuits, a push-button test switch, and an LED warning light. Mount them to a wall using the included mounting bracket and fasteners.
Hazardous location environmental ratings indicate where manufacturers have included safety features in products to facilitate their safe use in hazardous environments. Before selecting a product for a hazardous location, ensure it is rated for your environment.
| Ht. | Wd. | Thick. | Bulbs Included | Wire Connection Type | With Backup Battery | Mount Type | Mounting Fasteners Included | Environmental Rating | Specifications Met | Each | |
Exit | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Tempered Glass with Epoxy-Coated Aluminum Frame | |||||||||||
| 16 3/4" | 16 1/2" | 4 1/2" | Yes | Wire Leads | Yes | Wall, With Mounting Holes | Yes | NEC Class I Divisions 1, 2 Groups B, C, D NEC Class I Division 2 Group A NEC Class II Divisions 1, 2 Groups E, F, G IP66 | UL Listed, UL 844, UL 924 | 00000000 | 000000000 |
Backlit Exit Signs with Emergency Lights






Illuminate exits during power failures and other emergencies. These signs are lit from within for high visibility and have battery-powered emergency lighting. You can punch out one or both of their knockout arrows to point to the exit. Mount them flush against a wall, or use the included bracket to mount them perpendicular to a wall or ceiling.
Powder-coated steel signs are more durable than plastic signs.
Signs | Replacement Batteries | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Style | Message Location | Ht. | Wd. | Wire Connection Type | With Backup Battery | Bulbs Included | Emergency Light Technology | Mount Type | Mounting Fasteners Included | Features | Specifications Met | Each | Each | ||
Exit with Arrow (Green Message) | |||||||||||||||
Polycarbonate Plastic | |||||||||||||||
| A | Front, Back | 8" | 12" | Wire Leads | Yes | Yes | LED | Ceiling, Side, Wall, With Mounting Holes | Yes | Adjustable Emergency Lights, Two Knockout Arrows | UL 924 | 0000000 | 0000000 | 0000000 | 000000 |
Steel with Powder-Coated Steel Frame | |||||||||||||||
| B | Front | 13" | 12" | Wire Leads | Yes | Yes | LED | Ceiling, Side, Wall, With Mounting Holes | Yes | Adjustable Emergency Lights, Two Knockout Arrows | UL 924 | 0000000 | 000000 | 0000000 | 00000 |
ABS Plastic | |||||||||||||||
| C | Front, Back | 8 1/2" | 21" | Wire Leads | Yes | Yes | LED | Ceiling, Side, Wall, With Mounting Holes | Yes | Adjustable Emergency Lights, Two Knockout Arrows | UL 924 | 0000000 | 00000 | 0000000 | 00000 |
Exit with Arrow (Red Message) | |||||||||||||||
Polycarbonate Plastic | |||||||||||||||
| A | Front, Back | 8" | 12" | Wire Leads | Yes | Yes | LED | Ceiling, Side, Wall, With Mounting Holes | Yes | Adjustable Emergency Lights, Two Knockout Arrows | UL 924 | 0000000 | 000000 | 0000000 | 00000 |
Steel with Powder-Coated Steel Frame | |||||||||||||||
| B | Front | 13" | 12" | Wire Leads | Yes | Yes | LED | Ceiling, Side, Wall, With Mounting Holes | Yes | Adjustable Emergency Lights, Two Knockout Arrows | UL 924 | 0000000 | 000000 | 0000000 | 00000 |
ABS Plastic | |||||||||||||||
| C | Front, Back | 8 1/2" | 21" | Wire Leads | Yes | Yes | LED | Ceiling, Side, Wall, With Mounting Holes | Yes | Adjustable Emergency Lights, Two Knockout Arrows | UL 924 | 0000000 | 00000 | 0000000 | 00000 |
Backlit Exit Signs
These signs are lit from within for high visibility. Mount them flush against a wall, or use the included bracket to mount them perpendicular to a wall or ceiling.
Signs with a message on the front and back have the same message on both sides. Signs also included a solid back plate to display the message on one side.
Signs with a backup battery stay illuminated during power failures.
Signs with knockout arrows allow you to punch out one or both arrows to point to the exit.
Signs with red or green message color let you swap the color by sliding the color into the side of the fixture.
Plastic signs with a powder-coated steel frame are more durable than all-plastic signs.
Signs that cannot be sold to the listed areas are restricted by energy efficiency regulations.

Signs | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Ht. | Wd. | Bulbs Included | Wire Connection Type | With Backup Battery | Mount Type | Mounting Fasteners Included | Specifications Met | Cannot Be Sold To | Each | |
Glass with Steel Frame | ||||||||||
| 9" | 12" | Yes | Wire Leads | Yes | Side, With Mounting Holes | No | UL 924, City of Chicago Approved | Canada | 00000000 | 0000000 |

Signs | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Ht. | Wd. | Bulbs Included | Wire Connection Type | With Backup Battery | Mount Type | Mounting Fasteners Included | Specifications Met | Cannot Be Sold To | Each | |
Glass with Steel Frame | ||||||||||
| 9" | 12" | Yes | Wire Leads | Yes | Side, With Mounting Holes | No | UL 924, City of Chicago Approved | Canada | 00000000 | 0000000 |

Signs | Replacement Backup Batteries | Wire Guards | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ht. | Wd. | Bulbs Included | Wire Connection Type | With Backup Battery | Mount Type | Mounting Fasteners Included | Features | Specifications Met | Each | Each | Each | |||
Polycarbonate Plastic with Powder-Coated Steel Frame | ||||||||||||||
| 7" | 12" | Yes | Wire Leads | Yes | Side, With Mounting Holes | No | Two Knockout Arrows | UL 924 | 000000 | 0000000 | 0000000 | 000000 | 0000000 | 000000 |

Signs | Replacement Backup Batteries | Wire Guards | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ht. | Wd. | Bulbs Included | Wire Connection Type | With Backup Battery | Mount Type | Mounting Fasteners Included | Features | Specifications Met | Each | Each | Each | |||
Polycarbonate Plastic with Powder-Coated Steel Frame | ||||||||||||||
| 7" | 12" | Yes | Wire Leads | Yes | Side, With Mounting Holes | No | Two Knockout Arrows | UL 924 | 00000000 | 0000000 | 0000000 | 000000 | 0000000 | 000000 |

Signs | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Ht. | Wd. | Bulbs Included | Wire Connection Type | With Backup Battery | Mount Type | Mounting Fasteners Included | Specifications Met | Cannot Be Sold To | Each | |
Glass with Steel Frame | ||||||||||
| 9" | 12" | Yes | Wire Leads | Yes | Side, With Mounting Holes | No | UL 924, City of Chicago Approved | Canada | 00000000 | 0000000 |

Signs | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Ht. | Wd. | Bulbs Included | Wire Connection Type | With Backup Battery | Mount Type | Mounting Fasteners Included | Specifications Met | Cannot Be Sold To | Each | |
Glass with Steel Frame | ||||||||||
| 9" | 12" | Yes | Wire Leads | Yes | Side, With Mounting Holes | No | UL 924, City of Chicago Approved | Canada | 00000000 | 0000000 |
Washdown Backlit Exit Signs

These signs are rated NEMA 4X for corrosion resistance and washdown environments. They’re illuminated from within for high visibility.
Signs with a backup battery stay illuminated during power failures.
Signs cannot be sold to Canada due to energy efficiency requirements.
Signs | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mounting | Replacement Backup Battery | |||||||||||||||
| Ht. | Wd. | Bulbs Included | Light Technology | Wire Connection Type | With Backup Battery | Fasteners Included | Number of Holes | Hole Dia. | Features | Environmental Rating | Specifications Met | Cannot Be Sold To | Each | Each | ||
Exit with Arrow | ||||||||||||||||
With Mounting Holes—Polycarbonate Plastic | ||||||||||||||||
| 11" | 15" | Yes | LED | Wire Leads | Yes | No | 4 | 1/4" | Clear Plastic Cover Plate, Two Knockout Arrows | IP66, NEMA 4X | UL 924, NFPA 70 | Canada | 0000000 | 0000000 | 0000000 | 00000 |