    82 Products

    Continuous-Duty Any-Direction Constant-Flow-Rate Diaphragm Pumps for Water and Coolants

    Image of Product. Front orientation. Diaphragm Pumps. Continuous-Duty Any-Direction Constant-Flow-Rate Diaphragm Pumps for Water and Coolants.
    Rated for continuous use, this diaphragm pump is often used to move caustics such as antifreeze and salt water. Mount it in any position, even upside down. It is typically used for low-flow spraying, draining, and washdown applications. The pump is self-priming, which means it creates a suction force to draw liquid upward. Pump can run dry and does not require an initial fill, so it’s a good choice for applications without a constant flow of liquid. Do not use with solids.
    Pressure Switch—Pumps with a pressure switch automatically shut off the pump at the maximum pressure.
    Intake
    Discharge
    Overall
    Max. Flow
    Rate, gpm
    Flow Rate @
    Pressure
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Max. Temp.,
    ° F
    Power,
    hp
    Current,
    amp
    Connection
    Gender
    For Tube
    ID
    Connection
    Gender
    For Tube
    ID
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection and With Pressure Switch
     
    Plug In
    32.50 gpm @ 20 psi402501303/161.8BarbedMale1/2"BarbedMale1/2"10 7/8"5 3/8"5 5/8"00000000000000
     

    Fixed-Flow-Rate Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. Fixed-Flow-Rate Peristaltic Pumps for Chemicals.
    Also known as tubing pumps, these maintain a fixed flow rate. Pumps are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Mount them up to 25 feet above your liquid source. All can run dry. Do not use with solids.
    Viton® Fluoroelastomer Wetted Parts—Pumps with Viton® Fluoroelastomer tubing withstand oil such as gasoline and hydraulic oil.
    Pumps
    Replacement
    Pump Heads
    Overall
    Flow Rate, gal./day
    (For Tube ID)
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp.,
    ° F
    Power
    Current,
    amp
    Lg.
    Wd.
    Ht.
    Includes
    Each
    Each
    115V AC, Single Phase—Plug In
     
    PVDF and Viton® Fluoroelastomer Wetted Parts
    0.02 (1/32")
    0.07 (1/16")
    0.25 (1/8")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"4 1/2" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/32" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60)0000000000000000000000000000000
    0.11 (1/32")
    0.34 (1/16")
    1.25 (1/8")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"4 1/2" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/32" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60)00000000000000000000000000000
    0.87 (1/16")
    3.53 (1/8")
    6.84 (3/16")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"6" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)00000000000000000000000000000
    1.75 (1/16")
    7.07 (1/8")
    13.68 (3/16")
    3080032 to 122Fractional0.035 1/2"3 1/4"3 3/4"6" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)00000000000000000000000000000
    22.8 (3/16")
    38 (1/4")
    1550032 to 122Fractional0.525"5"7"6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)00000000000000000000000000000
    45.6 (3/16")
    76 (1/4")
    1520032 to 122Fractional0.655"5"7"6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)00000000000000000000000000000
    228 (3/16")
    380 (1/4")
    155032 to 122Fractional1.745"5"7"6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60)00000000000000000000000000000
     
    120V AC/240V AC, Single Phase—Plug In
     
    Norprene and Santoprene Wetted Parts
    6 (1/8")
    12 (3/16")
    20 (1/4")
    255,00033 to 104Not Rated25 5/8"6 1/4"5 3/4"9" Lg. of 1/4" ID Norprene Tubing (Shore A60), 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60)000000000000000000000000000000
    26 (1/8")
    56 (3/16")
    91 (1/4")
    255,00033 to 104Not Rated25 5/8"6 1/4"5 3/4"9" Lg. of 1/4" ID Norprene Tubing (Shore A60), 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60)000000000000000000000000000000
    42 (1/8")
    88 (3/16")
    144 (1/4")
    255,00033 to 104Not Rated25 5/8"6 1/4"5 3/4"9" Lg. of 1/4" ID Norprene Tubing (Shore A60), 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60)000000000000000000000000000000
    77 (1/8")
    162 (3/16")
    265 (1/4")
    255,00033 to 104Not Rated25 5/8"6 1/4"5 3/4"9" Lg. of 1/4" ID Norprene Tubing (Shore A60), 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60)000000000000000000000000000000
    122 (1/8")
    257 (3/16")
    421 (1/4")
    255,00033 to 104Not Rated25 5/8"6 1/4"5 3/4"9" Lg. of 1/4" ID Norprene Tubing (Shore A60), 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60)000000000000000000000000000000
     
    Replacement Pump Intake Tubes

    PTFE Air-Powered Double Diaphragm Pumps for Harsh Chemicals

    With all PTFE wetted parts, these pumps offer the best chemical resistance of all our air-powered double diaphragm pumps and can handle solvents and petroleum-based fluids that PVDF pumps can’t. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All can run dry.
    Threaded Side Intake and Threaded Side Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. PTFE Air-Powered Double Diaphragm Pumps for Harsh Chemicals, Threaded Side Intake and Threaded Side Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Overall
    Max. Flow
    Rate, gpm
    Max. Solids
    Dia.
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge
    Size
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    231 ft. Maximum Feet of Head—100 psi Maximum Discharge Pressure
    2.50.06"4.81/8 Female NPT1/4 Female NPT1/4 Female NPT3 3/8"5 1/2"6 1/2"0000000000000000000000000000000000000000000
    6.70.08"9.31/8 Female NPT3/8 Female NPT3/8 Female NPT3 1/2"5 7/8"7 5/8"0000000000000000000000000000000000000000
    160.16"291/4 Female NPT1/2 Female NPT1/2 Female NPT6"9 3/16"8"000000000000000000000000000000000000000000
    390.24"461/4 Female NPT1 Female NPT1 Female NPT8"10 7/8"10 3/8"000000000000000000000000000000000000000000
     

    Panel-Mount Fixed-Flow-Rate Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. Panel-Mount Fixed-Flow-Rate Peristaltic Pumps for Chemicals.
    Install these pumps in a panel cutout. Often used in food and beverage, pharmaceutical, and lab applications, they dispense small amounts of liquid at a set rate. Pumps can be wired to a switch for manual operation, or a PLC for automated equipment. The removable pump head includes an intake tube that quickly connects to your line with barbed fittings (not included). To change lines, disconnect tubing and twist and pull the head off the motor. Then twist on a replacement head (sold separately). Pumps come in three colors for easy identification or to match your existing equipment. All are self-priming and create suction to draw liquid upward. Mount pumps up to 28 ft. above your liquid source. They can run dry.
    Discharge
    Overall
    Blue Housing
    Clear Housing
    Green Housing
    Flow Rate,
    ml/min
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake
    Connection
    Tube
    ID
    Tube
    OD
    Connection
    Wd.
    Ht.
    Dp.
    Each
    Each
    Each
    24V DC
     
    Hardwire
    552510,00032 to 1001/1501.5Barbed3/16"5/16"Barbed2 1/2"2 1/2"4 1/8"000000000000000000000000000000000000000000000
    1602510,00032 to 1001/1501.5Barbed3/16"5/16"Barbed2 1/2"2 1/2"4 1/8"000000000000000000000000000000000000000000
     
    Replacement Pump Heads

    Compact Drum Pumps for Water and Chemicals

    Image of Product. Front orientation. Drum Pumps. Compact Drum Pumps for Water and Chemicals, Style A.
    Image of Product. Front orientation. Drum Pumps. Compact Drum Pumps for Water and Chemicals, Style B.

    Style A

    Style B

    Designed to move low volumes of caustic liquids in confined areas, these pumps have a thin intake tube and a small handle. They are often used to pump cleaning fluids, acid-washing solutions, and bleach.
    Style A—Style A pumps have a selectable flow rate, so you can adjust flow for different dispensing applications.
    Style B—Style B pumps have a flexible discharge spout.
    Temp.,
    ° F
    Intake
    Style
    Flow Rate, fl oz/stroke
    For Container
    Size, gal.
    Max.
    Viscosity
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Spout
    Type
    Drum Pump
    Type
    Each
    A2, 4, 6, 85Not RatedNot Rated1253/4 NPT5/8"18 1/4"Spout EndFixedPlunger0000000000000
    A2, 4, 6, 815 to 55Not RatedNot Rated1253/4 NPT, 2 NPTTwo Drum Connectors5/8"33"Spout EndFixedPlunger000000000000
    A4, 8, 12, 1615 to 55Not RatedNot Rated1253/4 NPT, 2 NPTTwo Drum Connectors5/8"33"Spout EndFixedPlunger000000000000
    B355Not Rated401502 NPTDrum Connector1 3/4"32"Spout EndFlexiblePlunger0000000000000
     

    Nondrip Drum Pumps for Fuel and Flammable Liquid

    Image of Product. Front orientation. Drum Pumps. Nondrip Drum Pumps for Fuel and Flammable Liquid.
    Eliminate leaks and waste with a faucet-style nondrip nozzle that quickly starts and stops flow. Pressurize your container with a few pumps of the plunger handle, and use the one-touch nozzle to manage flow. Hold down the nozzle for intermittent dispensing, open the nozzle fully for continuous flow, and close the nozzle to stop flow entirely.
    Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
    NFPA 30 18.4.4.1—NFPA approved pumps are rated for use with Class I and II flammable and combustible liquids such as fuels, alcohols, and acetone.
    Temp.,
    ° F
    Intake
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Drum Pump
    Type
    Nozzle
    Type
    Features
    Flammability
    Rating
    Each
    4.52 to 55270351102 NPTDrum Connector5/8"40"NozzlePlungerNondripBonding and Grounding WiresNFPA 30 18.4.4.1
    00000000000000
     

    Drum Pumps for Harsh Chemicals

    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Harsh Chemicals, Spout-End Discharge.
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Harsh Chemicals, Nozzle Discharge.

    Spout-End

    Discharge

    Nozzle Discharge

    Made with PTFE components, these pumps stand up to aggressive chemicals our other drum pumps can't, such as hydrochloric acid, bleach, sodium hydroxide, and methyl ethyl ketone (MEK). A stopcock prevents fluid and vapor from leaking after use.
    Temp.,
    ° F
    Intake
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Each
    Spout-End Discharge
    916500351052"Drum Connector1 1/4"23 5/8"000000000000000
     
    Nozzle Discharge
    916500351052"Drum Connector1 1/4"23 5/8"00000000000000
     

    Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. Peristaltic Pumps for Chemicals.
    An adjustment screw lets you increase or decrease flow rate without the hassle of changing tubing. Often used in boiler feed systems and water treatment, these pumps are compatible with chemicals such as cleaning fluids and acid-washing solutions. Pumps are self-priming and create suction to draw liquid upward. They can run dry.
    Pumps
    Replacement
    Pump Collars
    Replacement Pump
    Intake Tubes
    For
    Tube
    Overall
    Flow Rate,
    gal/day
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    ID
    OD
    Intake
    Connection
    Discharge
    Connection
    Lg.
    Wd.
    Ht.
    Includes
    Each
    Each
    Each
    120V AC, Single Phase
     
    Plug In
    2 to 122520035 to 1001/640.33/16"3/8"CompressionCompression8"7"6"9" Lg. of Tygon Tubing (Shore A70)0000000000000000000000000000000000000000000
    3 to 202520035 to 1001/640.31/4"7/16"CompressionCompression8"7"6"9" Lg. of Tygon Tubing (Shore A70)0000000000000000000000000000000000000000
     
    Replacement Pump Heads

    High-Pressure Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. High-Pressure Peristaltic Pumps for Chemicals.
    These pumps can be used with pressures four times higher than standard pumps. An adjustment dial lets you alter flow rate in 2.5% increments of the maximum flow without the hassle of changing tubing. Often used in boiler feed systems and water treatment, they're compatible with chemicals such as cleaning fluids and acid-washing solutions. Pumps are self-priming and create suction to draw liquid upward. They can run dry.
    Pumps
    Replacement
    Pump Heads
    Replacement
    Tubing
    Discharge
    Overall
    Flow Rate,
    gal/day
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake
    Connection
    Tube
    ID
    Tube
    OD
    Connection
    Lg.
    Wd.
    Ht.
    Includes
    Each
    Each
    Each
    120V AC, Single Phase
     
    Plug In
    0.3 to 51001,50035 to 1251/301.7Compression3/16"1/4"Compression11"5"6"20-ft. Lg. of LDPE Plastic Intake/Discharge Tubing00000000000000000000000000000000000000000
    0.8 to 171001,50035 to 1251/301.7Compression3/16"1/4"Compression11"5"6"20-ft. Lg. of LDPE Plastic Intake/Discharge Tubing00000000000000000000000000000000000000
    2 to 401001,50035 to 1251/301.7Compression3/16"1/4"Compression11"5"6"20-ft. Lg. of LDPE Plastic Intake/Discharge Tubing00000000000000000000000000000000000000
     

    Inline Water-Powered Metering Syringe Pumps for Chemicals

    Image of Product. Front orientation. Syringe Pumps. Inline Water-Powered Metering Syringe Pumps for Chemicals.
    Inject chemicals into your water supply without using electricity—these pumps install directly in your pipeline and activate when water flows into the pump head. They provide consistent metering regardless of pressure and flow changes and have an adjustment dial for altering dosing concentration. Pumps are often used with bleach, cleaning solutions, and water-treatment chemicals. All are self-priming and create suction to draw liquid upward. Do not use with solids.
    Intake
    Discharge
    Overall
    Flow Rate,
    gpm
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Concentration
    Ratio
    Max. Temp.,
    ° F
    Pipe
    Size
    Thread
    Type
    Gender
    Pipe
    Size
    Thread
    Type
    Gender
    Dia.
    Ht.
    Includes
    Each
    0.05 to 14852001:500 to 1:501003/4
    NPT
    Male3/4
    NPT
    Male6 5/16"19"6-ft. PVC Plastic Intake Tube00000000000000
    0.05 to 14852001:3000 to 1:3331003/4
    NPT
    Male3/4
    NPT
    Male6 5/16"21"6-ft. PVC Plastic Intake Tube000000000000000
    0.05 to 14851,7001:100 to 1:101003/4
    NPT
    Male3/4
    NPT
    Male6 5/16"19"6-ft. PVC Plastic Intake Tube000000000000000
    0.05 to 14851,7001:200 to 1:201003/4
    NPT
    Male3/4
    NPT
    Male6 5/16"19"6-ft. PVC Plastic Intake Tube000000000000000
     

    PVDF Long-Life Air-Powered Drum Pumps for Chemicals

    Image of Product. Front orientation. Drum Pumps. PVDF Long-Life Air-Powered Drum Pumps for Chemicals.
    A chemical- and impact-resistant PVDF housing stands up to aggressive chemicals such as methyl ethyl ketone (MEK) and xylene. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Pump Repair Kits—Repair kits include O-rings, valves, and diaphragms.
    Drum Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Connection
    Pipe Size
    Tube
    Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    Each
     
    PTFE Diaphragm
    13553,00040210100122 NPTDrum Connector1/4 Female NPTThreaded1/2 Female NPT36"Pump BodyThreaded1/2 Female NPT0000000000000000000000000000000
     

    Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15.

    NEMA

    5-15

    Plug

    Including nozzles and connectors, these pumps come with everything you need to start pumping. All include a pump assembly, 1" ID hose, dispensing nozzle, drum connector, and storage bracket.
    PVDF Housing—Pumps with a PVDF housing are often used with aggressive chemicals such as 98% nitric acid, hydrochloric acid, and sulfuric acid. Their motors are rated IP54.
    47" Long Intake Tube—Pumps with a 47" intake tube can be used with large totes and tanks.
    Temp.
    Intake
    Discharge
    Electrical
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Enclosure
    Rating
    Connection
    No. of
    Blades
    Each
    120V AC—Single Phase—NEMA 5-15 Plug In
     
    PVDF Housing
    1515551,500Not Rated17517.52 NPT1 5/8"39"1"1 1/4"72"IP54
    Straight Blade30000000000000000
    1515551,500Not Rated17517.52 NPT1 5/8"47"1"1 1/4"72"IP54
    Straight Blade3000000000000000
     

    Air-Powered Drum Pumps with Hose and Filter/Lubricator for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Contains Annotated. Drum Pumps. Air-Powered Drum Pumps with Hose and Filter/Lubricator for Water, Oil, Coolants, and Chemicals.
    A filter/lubricator ensures efficiency and reduces wear on the pump. They have a chemically resistant seal for use with hydraulic oil and motor oil in addition to acidic and alkaline liquids such as ammonia and etching and cleaning solutions. Pumps have a nonsparking motor for use in applications where electricity is unavailable or dangerous.
    Drum Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Tube
    ID
    Tube Lg.,
    ft.
    Tube
    Material
    Features
    Each
    Each
    16552,0003515080 to 100322 NPTDrum Connector1/4 Female NPT1 5/8"40"Tube End1"5PVC
    15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler000000000000000000000000000000
     
    Couplings
    back to top