    61 Products

    Hazardous Location Spark-Resistant Blowers

    These blowers have an explosion-proof motor that is UL listed for hazardous locations. They also have an aluminum housing for spark resistance. These blowers install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water. It is the responsibility of users in California to follow local energy efficiency regulations. Operating these blowers at a high airflow may violate these regulations.
    With Round Outlet and Round Inlet
    Image of Product. Front orientation. Blowers. Hazardous Location Spark-Resistant Blowers.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Hazardous Location Rating
    Enclosure
    Rating
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC/230V AC
     
    Single Phase—Hardwire
    995 ft³/min @ 1 in. H₂O
    1,070 ft³/min @ 1/4 in. H₂O
    70 dBA @ 15 ft.3,4501 1/26"6"6 1/4"14 1/8"12 1/4"13 1/4"15.4 amp/8.4 amp0 to 150AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    IP54
    No7/16"1955K82000000000
     

    Suspended-Hood Hazardous Location Fume Exhausters

    Image of Product. Front orientation. ZoomedIn view. Fume Exhausters. Suspended-Hood Hazardous Location Fume Exhausters.
    Position these exhausters above drums, tanks, and distillers to remove fumes, vapors, and fine dust particles from your space. All have a motor that is UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups F and G locations. Exhausters include a pulley system to adjust the hood height. Add an optional fume exhauster mounting bracket (sold separately) for side-to-side movement.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Fume Exhausters
    Fume Exhauster
    Mounting Brackets
    Hose
    Hood
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    ID
    Lg.,
    ft.
    Includes
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    Each
     
    120V AC/230V AC—Hardwire
    27"450 ft³/min @ 0 in. H₂O69 dB @ 5 ft.1/26"10Blower, Outside Vent KitNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    IP54
    21105K4100000000021105K750000000
    32"450 ft³/min @ 0 in. H₂O69 dB @ 5 ft.1/26"10Blower, Outside Vent KitNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    IP54
    21105K420000000021105K75000000
    37"450 ft³/min @ 0 in. H₂O69 dB @ 5 ft.1/26"10Blower, Outside Vent KitNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    IP54
    21105K430000000021105K75000000
    44"450 ft³/min @ 0 in. H₂O69 dB @ 5 ft.1/26"10Blower, Outside Vent KitNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    IP54
    21105K440000000021105K76000000
     

    Wet-Location Enclosure-Cooling Fans

    Able to withstand dust and water splashes, these fans are IP54 rated. They protect equipment in enclosures and cabinets from heat. All of these fans are reversible to exhaust hot air out or draw cooler outside air in through a filter that removes dirt and dust. They have UL recognized components.
    Square
    Image of Product. Front orientation. Fans. Wet-Location Enclosure-Cooling Fans.
    Replacement Filters—Replacement filters are sold separately.
    Fans
    Replacement Filters
    For
    Opening
    Overall
    Blade
    Mounting
    Ht.
    Wd.
    Airflow
    Volume
    Motor Speed,
    rpm
    Current
    Ht.
    Wd.
    Dp.
    Material
    Rotation
    Guard
    Material
    Fasteners
    Included
    Hole
    Dia.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Includes
    Each
    Pkg.
    Qty.
    Pkg.
    24V DC, Single Phase—Terminal Block
    3 5/8"3 5/8"12 ft³/min38 dBANot Rated0.10 amp4 5/8"4 5/8"1 3/4"PlasticReversiblePlasticNo0.138"IP54, NEMA 12
    CSA Certified, UL Recognized Component
    UL 508ADisposable Filter19115K3170000000519115K511000000
    4 7/8"4 7/8"32 ft³/min46 dBANot Rated0.20 amp5 7/8"5 7/8"2 5/16"PlasticReversiblePlasticNo0.138"IP54, NEMA 12
    CSA Certified, UL Recognized Component
    UL 508ADisposable Filter19115K318000000519115K1500000
    7"7"62 ft³/min46 dBANot Rated0.20 amp8"8"3 9/16"PlasticReversiblePlasticNo0.177"IP54, NEMA 12
    CSA Certified, UL Recognized Component
    UL 508ADisposable Filter19115K319000000519115K1600000
    8 13/16"8 13/16"160 ft³/min54 dBANot Rated0.80 amp10"10"4 1/4"PlasticReversiblePlasticYes0.177"IP54, NEMA 12
    CSA Certified, UL Recognized Component
    UL 508ADisposable Filter19115K321000000519115K1700000
     
    115V AC, Single Phase, 50Hz/60Hz—Terminal Block
    3 5/8"3 5/8"15 ft³/min38 dBANot Rated0.10 amp4 5/8"4 5/8"1 3/4"PlasticReversiblePlasticNo0.138"IP54, NEMA 12
    CSA Certified, UL Recognized Component
    UL 508ADisposable Filter19115K311000000519115K51100000
     
    120V AC, Single Phase, 50Hz/60Hz—Terminal Block
    4 7/8"4 7/8"39 ft³/min46 dBA3,1000.24 amp5 7/8"5 7/8"2 5/16"PlasticReversiblePlasticNo0.138"IP54, NEMA 12
    CSA Certified, UL Recognized Component
    UL 508ADisposable Filter19115K5000000519115K1500000
    7"7"71 ft³/min49 dBA3,1000.24 amp8"8"3 9/16"PlasticReversiblePlasticNo0.177"IP54, NEMA 12
    CSA Certified, UL Recognized Component
    UL 508ADisposable Filter19115K6000000519115K1600000
    8 13/16"8 13/16"145 ft³/min56 dBA3,2500.52 amp10 1/16"10 1/16"4 1/4"PlasticReversiblePlasticYes0.177"IP54, NEMA 12
    CSA Certified, UL Recognized Component
    UL 508ADisposable Filter19115K7000000519115K1700000
    11 1/2"11 1/2"350 ft³/min61 dBA2,8000.78 amp12 3/4"12 3/4"4 1/2"PlasticReversiblePlasticYes0.177"IP54, NEMA 12
    CSA Certified, UL Recognized Component
    UL 508ADisposable Filter19115K8000000519115K18000000
     
    230V AC, Single Phase, 50Hz/60Hz—Terminal Block
    3 5/8"3 5/8"15 ft³/min38 dBANot Rated0.05 amp4 5/8"4 5/8"1 3/4"PlasticReversiblePlasticNo0.138"IP54, NEMA 12
    CSA Certified, UL Recognized Component
    UL 508ADisposable Filter19115K312000000519115K51100000
    4 7/8"4 7/8"39 ft³/min46 dBANot Rated0.10 amp5 7/8"5 7/8"2 5/16"PlasticReversiblePlasticNo0.138"IP54, NEMA 12
    CSA Certified, UL Recognized Component
    UL 508ADisposable Filter19115K313000000519115K1500000
    7"7"71 ft³/min46 dBANot Rated0.10 amp8"8"3 9/16"PlasticReversiblePlasticNo0.177"IP54, NEMA 12
    CSA Certified, UL Recognized Component
    UL 508ADisposable Filter19115K314000000519115K1600000
    8 13/16"8 13/16"147 ft³/min54 dBANot Rated0.20 amp10"10"4 1/4"PlasticReversiblePlasticYes0.177"IP54, NEMA 12
    CSA Certified, UL Recognized Component
    UL 508ADisposable Filter19115K315000000519115K1700000
    11 1/2"11 1/2"453 ft³/min65 dBANot Rated0.50 amp12 11/16"12 11/16"5 3/16"PlasticReversiblePlasticYes0.177"IP54, NEMA 12
    CSA Certified, UL Recognized Component
    UL 508ADisposable Filter19115K316000000519115K411000000
     
    Enclosure Hoods

    Hazardous Location Jet Stream Fans

    UL listed for use in hazardous environments, these fans are often used to cool warehouse aisles and production lines. They generate a stream of air that travels farther than air from conventional fans. All fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Freestanding Fans with Wheels
    Image of Product. Front orientation. Fans. Hazardous Location Jet Stream Fans, Wheels.
    Fans with wheels can be rolled into place before they are hardwired. They do not allow for movement once the unit is in use.
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
    Blade
    Overall
    Dia.
    Material
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Ht.
    Wd.
    Dp.
    Fan Head
    Movement
    Drive
    Type
    Housing
    Material
    Guard
    Material
    Each
    120/230V AC, Single Phase—Hardwire
    24"Aluminum7,80069 dBA @ 5 ft.1,7501114.0 amp/6.9 amp45"30"32"Non-OscillatingDirectSteelSteel1903K58000000000
     
    230/460V AC, Three Phase—Hardwire
    36"Aluminum20,00086 dBA @ 5 ft.1,750138.2 amp/4.1 amp51"42"32"Non-OscillatingDirectSteelSteel1903K7200000000
     
    Freestanding Fans without Wheels
    Image of Product. Front orientation. Fans. Hazardous Location Jet Stream Fans.
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
    Blade
    Overall
    Dia.
    Material
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Ht.
    Wd.
    Dp.
    Fan Head
    Movement
    Drive
    Type
    Housing
    Material
    Guard
    Material
    Each
    230/460V AC, Three Phase—Hardwire
    24"Aluminum7,80069 dBA @ 5 ft.1,750113.0 amp/1.5 amp41"30"32"Non-OscillatingDirectSteelSteel1903K65000000000
    36"Aluminum20,00086 dBA @ 5 ft.1,750138.2 amp/4.1 amp47"42"32"Non-OscillatingDirectSteelSteel1903K7400000000
     

    Wet-Location Equipment-Cooling Fans

    Able to withstand dust and water splashes, these fans are IP rated. Also known as muffin fans, they keep heat-sensitive equipment such as electronic components cool. All have ball bearings to lower the heat that is generated from the fans for a longer service life. They also have UL recognized components.
    Square
    Image of Product. Front orientation. Fans. Wet-Location Equipment-Cooling Fans, Square.
    Wire Lead Connection—Install fans with wire leads directly to your power source—there’s no need for additional connectors.
    Overall
    Mounting
    Airflow
    Temp. Range,
    ° F
    Volume
    Current
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Bearing
    Type
    Fasteners
    Included
    Hole Dia.
    Enclosure
    Rating
    Certification
    Each
    85V AC to 265V AC, Single Phase, 50Hz/60Hz—Wire Leads
    47 ft³/min0 to 15548 dBA0.08 amp3.150" (80 mm)3.150" (80 mm)1.26" (32 mm)PlasticPlasticBall
    No0.170" (4.32 mm)IP54
    CCC Marked, CE Marked, CSA Certified, UL Recognized Component
    9602K310000000
    84 ft³/min0 to 15555 dBA0.11 amp3.622" (92 mm)3.622" (92 mm)1.5" (38.1 mm)PlasticPlasticBall
    No0.170" (4.32 mm)IP54
    CCC Marked, CE Marked, CSA Certified, UL Recognized Component
    9602K32000000
     
    Round
    Image of Product. Front orientation. Fans. Wet-Location Equipment-Cooling Fans, Round.
    Wire Lead Connection—Install fans with wire leads directly to your power source—there’s no need for additional connectors.
    Overall
    Mounting
    Airflow
    Temp. Range,
    ° F
    Volume
    Current
    Dia.
    Dp.
    Frame
    Material
    Blade
    Material
    Bearing
    Type
    Fasteners
    Included
    Hole Dia.
    Enclosure
    Rating
    Certification
    Each
    85V AC to 265V AC, Single Phase, 50Hz/60Hz—Wire Leads
    205 ft³/min0 to 16050 dBA0.14 amp6.772" (172 mm)2.000" (50.8 mm)AluminumPlasticBall
    No0.170" (4.32 mm)IP54
    CCC Marked, CE Marked, CSA Certified, UL Recognized Component
    9602K330000000
     

    Enclosure-Cooling Heat Exchangers

    Image of Product. Front orientation. Heat Exchangers. Enclosure-Cooling Heat Exchangers, NEMA 12 Enclosure Rating.

    NEMA 12

    Enclosure Rating

    Cool the air in your enclosure to protect electronic components from excessive heat. These heat exchangers absorb heat in the enclosure, then use cooler air outside the enclosure to draw the heat away, lowering the temperature inside. Unlike a fan, they seal out outside air, so dust, moisture, and other contaminants can't get in. Because they use ambient air to cool the enclosure, heat exchangers use less energy and are less likely to cause condensation than air conditioners.
    All of these heat exchangers meet American and Canadian safety standards.
    NEMA 12 Enclosure Rating and IP54 Enclosure Rating—Heat exchangers that meet NEMA 12 and IP54 seal out dust, dirt, and splashing water and oil. Made of steel, these enclosures are powder coated, so they won’t rust in damp environments, but they’re not watertight enough to use outdoors.
    Overall
    For
    Opening
    Cooling Cap.,
    BTU/hr
    Airflow,
    ft³/min
    Wattage,
    W
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Material
    Thermostat
    Included
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Certification
    Each
    NEMA 12, IP54 Enclosure Rating
     
    120V AC, Single Phase, 60 Hz—Screw Terminal Connection
    4,400180750.935"12"11"17"10"Powder-Coated SteelYesNoYesUL Listed
    C-UL Listed
    7147N13000000000
    6,800180750.935"12"11"17"10"Powder-Coated SteelYesNoYesUL Listed
    C-UL Listed
    7147N2300000000
    10,2005603452.835"12"11"17"10"Powder-Coated SteelYesNoYesUL Listed
    C-UL Listed
    7147N3300000000
    12,2005603452.835"12"11"17"10"Powder-Coated SteelYesNoYesUL Listed
    C-UL Listed
    7147N4300000000
     
    230V AC, Single Phase, 50 Hz/60 Hz—Screw Terminal Connection
    4,400180750.435"12"11"17"10"Powder-Coated SteelYesNoYesUL Listed
    C-UL Listed
    7147N1600000000
    6,800180750.435"12"11"17"10"Powder-Coated SteelYesNoYesUL Listed
    C-UL Listed
    7147N2600000000
    10,2005602451.435"12"11"17"10"Powder-Coated SteelYesNoYesUL Listed
    C-UL Listed
    7147N3600000000
    12,2005602451.435"12"11"17"10"Powder-Coated SteelYesNoYesUL Listed
    C-UL Listed
    7147N4600000000
     
    460V AC, Single Phase, 50 Hz/60 Hz—Screw Terminal Connection
    4,400180750.235"12"11"17"10"Powder-Coated SteelYesNoYesUL Listed
    C-UL Listed
    7147N1900000000
    6,800180750.235"12"11"17"10"Powder-Coated SteelYesNoYesUL Listed
    C-UL Listed
    7147N2900000000
    10,2005602450.735"12"11"17"10"Powder-Coated SteelYesNoYesUL Listed
    C-UL Listed
    7147N3900000000
    12,2005602450.735"12"11"17"10"Powder-Coated SteelYesNoYesUL Listed
    C-UL Listed
    7147N4900000000
     
    back to top