    High-Output Spark-Resistant Blowers

    Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard spark-resistant blowers can handle. They have an aluminum housing for spark resistance. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    With Round Outlet and Round Inlet—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Blowers. High-Output Spark-Resistant Blowers.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC/230V AC
     
    Single Phase—Hardwire
    460 ft³/min @ 5 in. H₂O
    520 ft³/min @ 3 in. H₂O
    80 dBA @ 15 ft.3,45015"6"9 3/4"18"14 1/2"16 1/8"7013.6 amp/6.8 amp0 to 100AluminumNo7/16"0000000000000000
    530 ft³/min @ 5 in. H₂O
    685 ft³/min @ 3 in. H₂O
    80 dBA @ 15 ft.3,4501 1/25"6"10 5/8"18"14 1/2"16 1/8"5517.8 amp/8.9 amp0 to 100AluminumNo7/16"000000000000000
    750 ft³/min @ 5 in. H₂O
    850 ft³/min @ 3 in. H₂O
    76 dBA @ 15 ft.3,45025"6"12"18 1/4"17 5/16"17 5/16"9617.5 amp/8.7 amp-10 to 150AluminumNo7/16"000000000000000
     
    230V AC/460V AC
     
    Three Phase—Hardwire
    460 ft³/min @ 5 in. H₂O
    520 ft³/min @ 3 in. H₂O
    80 dBA @ 15 ft.3,45015"6"9 3/4"18"14 1/2"16 1/8"653.1 amp/1.6 amp0 to 100AluminumNo7/16"000000000000000
    530 ft³/min @ 5 in. H₂O
    685 ft³/min @ 3 in. H₂O
    80 dBA @ 15 ft.3,4501 1/25"6"10 5/8"18"14 1/2"16 1/8"734.2 amp/2.1 amp0 to 100AluminumNo7/16"000000000000000
    750 ft³/min @ 5 in. H₂O
    850 ft³/min @ 3 in. H₂O
    76 dBA @ 15 ft.3,45025"6"12"18 1/4"17 5/16"17 5/16"884.9 amp/2.4 amp-10 to 150AluminumNo7/16"000000000000000
     

    High-Output Hazardous Location Spark-Resistant Blowers

    Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard hazardous location spark-resistant blowers can handle. They have an explosion-proof motor that is UL listed for hazardous locations. They also have an aluminum housing for spark resistance. These blowers install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water. It is the responsibility of users in California to follow local energy efficiency regulations. Operating these blowers at a high airflow may violate these regulations.
    With Round Outlet and Round Inlet
    Image of Product. Front orientation. Blowers. High-Output Hazardous Location Spark-Resistant Blowers.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Hazardous Location Rating
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC/230V AC
     
    Single Phase—Hardwire
    460 ft³/min @ 5 in. H₂O
    520 ft³/min @ 3 in. H₂O
    80 dBA @ 15 ft.3,45015"6"9 3/4"18"14 1/2"16 1/8"8012.0 amp/6.0 amp0 to 100AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    No7/16"0000000000000000
    530 ft³/min @ 5 in. H₂O
    685 ft³/min @ 3 in. H₂O
    80 dBA @ 15 ft.3,4501 1/25"6"10 5/8"18"14 1/2"16 1/8"8815.0 amp/7.5 amp0 to 100AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    No7/16"000000000000000
    850 ft³/min @ 3 in. H₂O76 dBA @ 15 ft.3,45025"6"12"18 1/4"17 5/16"17 7/16"9620.0 amp/10.0 amp-10 to 150AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    No7/16"0000000000000000
     
    230V AC/460V AC
     
    Three Phase—Hardwire
    460 ft³/min @ 5 in. H₂O
    520 ft³/min @ 3 in. H₂O
    80 dBA @ 15 ft.3,45015"6"9 3/4"18"14 1/2"16 1/8"653.6 amp/1.8 amp0 to 100AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    No7/16"000000000000000
    530 ft³/min @ 5 in. H₂O
    685 ft³/min @ 3 in. H₂O
    80 dBA @ 15 ft.3,4501 1/25"6"10 5/8"18"14 1/2"16 1/8"733.8 amp/1.9 amp0 to 100AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    No7/16"000000000000000
    850 ft³/min @ 3 in. H₂O76 dBA @ 15 ft.3,45025"6"12"19 11/16"17 5/16"17 7/16"1262.3 amp/1.2 amp-10 to 150AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    No7/16"0000000000000000
     

    Floor-Mount Fume Exhausters

    Image of Product. Front orientation. Fume Exhausters. Floor-Mount Fume Exhausters, Black Powder-Coated Steel.

    Black Powder-Coated Steel

    Mount these exhausters to the floor to remove fumes, vapors, and fine dust particles from your space. They are commonly used in welding, soldering, and other operations that create fumes.
    Totally Enclosed Motor Enclosure—Totally enclosed exhausters have an external fan for cooling. These exhausters offer more protection than open dripproof exhausters. They can be used in dirty, dusty, and damp environments, but are not airtight.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    Inlet
    Dia.
    Outlet
    Dia.
    Ht.
    Wd.
    Dp.
    Housing Material
    Base
    Material
    Wheel
    Material
    Fasteners
    Included
    For Screw
    Size
    Hole
    Dia.
    No. of
    Holes
    Each
    Totally Enclosed Motor Enclosure
     
    120V AC, Single Phase—Plug In
    755 ft³/min @ 1/2 in. H₂O72 dBA @ 15 ft.3/46"5"20 1/4"17"15 3/4"Black Powder-Coated SteelSteelAluminum
    No3/8"
    7/16"400000000000000000
     
    Duct Kits

    Chemical-Resistant Blowers

    For resistance to chemicals as well as corrosion, these blowers have a plastic housing. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    With Round Outlet and Round Inlet—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Blowers. Chemical-Resistant Blowers, Round Outlet.
    Image of Product. Front orientation. Blower Wheels. Chemical-Resistant Blowers.

    Replacement Wheels

    PVC Housing—PVC housing offers greater chemical resistance than the fiberglass housing. It resists strong oxidizing acids such as sulfuric acid but will not withstand contact with perchloric acid.
    Blowers
    Replacement
    Wheels
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Housing
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    Each
    120V AC/230V AC
     
    Single Phase—Hardwire
    185 ft³/min @ 1/2 in. H₂ONot Rated1,7251/65"6"5 11/16"12 1/4"11"14 1/2"323.8 amp/1.9 ampPVCNo3/8"0000000000000000000000000000000
     

    Hazardous Location Chemical-Resistant Blowers

    These blowers have an explosion-proof motor that is UL listed and CSA certified for Class I, Divisions 1 and 2, Group D; and Class II, Divisions 1 and 2, Groups F and G hazardous locations. For resistance to chemicals as well as corrosion, they have a plastic housing. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    With Round Outlet and Round Inlet
    Image of Product. Front orientation. Blowers. Hazardous Location Chemical-Resistant Blowers, Round Outlet.
    Image of Product. Front orientation. Blower Wheels. Hazardous Location Chemical-Resistant Blowers.

    Replacement Wheels

    PVC Housing—PVC housing offers greater chemical resistance than the fiberglass housing. It resists strong oxidizing acids such as sulfuric acid but will not withstand contact with perchloric acid.
    Blowers
    Replacement
    Wheels
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Current
    Housing
    Material
    Hazardous Location Rating
    Fasteners
    Included
    Hole
    Dia.
    Each
    Each
    120V AC
     
    Single Phase—Hardwire
    185 ft³/min @ 1/2 in. H₂ONot Rated1,7251/65"6"5 11/16"12 1/4"11"15 1/2"1.9 ampPVCNEC Class I Divisions 1, 2 Group D
    NEC Class II Divisions 1, 2 Groups F, G
    No3/8"0000000000000000000000000000000
     