McMaster-Carr logo
    Filter by
    Inlet Diameter
    Electrical Phase
    Outlet Shape
    Outlet Diameter
    Power Source
    Wheel Diameter
    Wheel Material
    Electrical Connection Type
    For Duct Diameter
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    41 Products

    High-Flow Low-Pressure Compressed Air Blowers

    Also known as regenerative blowers, use these to produce high-flow compressed air with low pressure or vacuum to operate pump drives, lift tables, and conveying systems. Compressed air blowers are also used for drying, exhausting, and aeration.
    Air circulates inside the blower housing to compress air, which generates pressure or vacuum.
    Single Stage
    Image of Product. Front orientation. Blowers. High-Flow Low-Pressure Compressed Air Blowers, Single Stage.
    Single-stage blowers circulate air once and then exhaust.
    Blowers
    Air Intake
    Filters
    Valves
    Overall
    Pipe
    Size
    Max. Pressure
    Max. Flow Rate
    @ Pressure
    Vacuum Rating
    Power,
    hp
    Full Load Current @ Voltage
    Volume (Sound),
    dBA
    Lg.
    Wd.
    Ht.
    Temp. Range,
    ° F
    Inlet
    Outlet
    Each
    Each
    Each
    Single Phase, 120/208/230V AC
     
    NPT Female Inlet and Outlet
    2 psi
    65 in. H₂O
    127 ft³/min @ 0 psi4.4 in. Hg
    60 in. H₂O
    1 1/217.5 amp @ 115V AC
    10 amp @ 208V AC
    9 amp @ 230V AC
    7416"13"14"32 to 1001 1/2
    1 1/2
    9960K580000000009960K82500000009960K8210000000
     
    Single Phase, 120/230V AC (Not Inverter Rated)
     
    BSPP Female Inlet and Outlet
    3 psi
    76 in. H₂O
    102 ft³/min @ 0 psi5.3 in. Hg
    72 in. H₂O
    1 1/216 amp @ 115V AC
    8 amp @ 230V AC
    6412"11"12"5 to 1001 1/2
    1 1/2
    1010K4200000000———0———0
     
    Three Phase, 208/230/460V AC
     
    NPT Female Inlet and Outlet
    2 psi
    65 in. H₂O
    127 ft³/min @ 0 psi4.4 in. Hg
    60 in. H₂O
    1 1/25.1 amp @ 208V AC
    4.9 amp @ 230V AC
    2.5 amp @ 460V AC
    7414"13"14"32 to 1001 1/2
    1 1/2
    9960K59000000009960K8250000009960K821000000
     
    Two Stage
    Image of Product. Front orientation. Blowers. High-Flow Low-Pressure Compressed Air Blowers, Two Stage.
    Two-stage blowers circulate air twice and then exhaust, creating higher pressure or vacuum than single-stage blowers with the same horsepower.
    Inverter Rated—Inverter-rated blowers have a motor that can run at slow speeds without overheating, so they can be used with a motor speed control (variable frequency drive).
    Blowers
    Valves
    Overall
    Pipe
    Size
    Max. Pressure
    Max. Flow Rate
    @ Pressure
    Vacuum Rating
    Power,
    hp
    Full Load Current @ Voltage
    Volume (Sound),
    dB
    Lg.
    Wd.
    Ht.
    Temp. Range,
    ° F
    Inlet
    Outlet
    Each
    Each
    Single Phase, 120/208/230V AC
     
    NPT Female Inlet and Outlet
    5 psi
    161 in. H₂O
    41 ft³/min @ 0 psi10.3 in. Hg
    140 in. H₂O
    1 1/214.6 amp @ 115V AC
    7.6 amp @ 208V AC
    7.3 amp @ 230V AC
    6914"11"12"5 to 1001 1/4
    1 1/4
    4393K610000000004393K410000000
     
    Three Phase, 208/230/460V AC (Inverter Rated)
     
    NPT Female Inlet and Outlet
    5 psi
    161 in. H₂O
    41 ft³/min @ 0 psi10.3 in. Hg
    140 in. H₂O
    1 1/24.3 amp @ 208V AC
    4.3 amp @ 230V AC
    2.1 amp @ 460V AC
    6914"11"12"5 to 1001 1/4
    1 1/4
    4393K62000000004393K41000000
     

    Corrosion-Resistant Blowers

    A 304 stainless steel housing offers good corrosion resistance. These blowers install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    With Rectangular Outlet and Round Inlet—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Blowers. Corrosion-Resistant Blowers.
    Blowers
    Replacement
    Wheels
    Outlet
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Ht.
    Wd.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Current
    Temp. Range,
    ° F
    Housing Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    Each
    120V AC/208V AC to 230V AC
     
    Single Phase—Hardwire
    505 ft³/min @ 4 1/2 in. H₂O
    635 ft³/min @ 3 1/4 in. H₂O
    74 dBA @ 15 ft.3,4501 1/25 5/8"3 5/8"5"10"17 3/4"15 3/8"14 5/8"13.2 amp/7.3 amp-15 to 180304 Stainless SteelNo1/2"2283K290000000001953K9220000000
     
    230V AC/460V AC
     
    Three Phase—Hardwire
    505 ft³/min @ 4 1/2 in. H₂O
    635 ft³/min @ 3 1/4 in. H₂O
    74 dBA @ 15 ft.3,4501 1/25 5/8"3 5/8"5"10"17 3/4"15 3/8"14 5/8"3.92 amp/1.96 amp-15 to 180304 Stainless SteelNo1/2"2283K31000000001953K922000000
     

    Floor-Mount Fume Exhausters

    Image of Product. Front orientation. Fume Exhausters. Floor-Mount Fume Exhausters, Black Powder-Coated Steel.
    Image of Product. Front orientation. Fume Exhausters. Floor-Mount Fume Exhausters, Aluminum.

    Black Powder-Coated Steel

    Aluminum

    Mount these exhausters to the floor to remove fumes, vapors, and fine dust particles from your space. They are commonly used in welding, soldering, and other operations that create fumes.
    Totally Enclosed Motor Enclosure—Totally enclosed exhausters have an external fan for cooling. These exhausters offer more protection than open dripproof exhausters. They can be used in dirty, dusty, and damp environments, but are not airtight.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    Inlet
    Dia.
    Outlet
    Dia.
    Ht.
    Wd.
    Dp.
    Housing Material
    Base
    Material
    Wheel
    Material
    Fasteners
    Included
    For Screw
    Size
    Hole
    Dia.
    No. of
    Holes
    Each
    Totally Enclosed Motor Enclosure
     
    120V AC/230V AC, Single Phase—Hardwire
    1,045 ft³/min @ 1/2 in. H₂O75 dBA @ 15 ft.1 1/26"6"16 3/8"12 1/4"18"Aluminum
    SteelSteelNo3/8"
    7/16"41951K126000000000
     
    230V AC/460V AC, Three Phase—Hardwire
    855 ft³/min @ 1/2 in. H₂O74 dBA @ 15 ft.1 1/26"6"22 7/8"19 1/8"17 1/8"Black Powder-Coated SteelSteelAluminum
    No3/8"
    7/16"41951K11600000000
     
    Duct Kits

    High-Output Spark-Resistant Blowers

    Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard spark-resistant blowers can handle. They have an aluminum housing for spark resistance. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    With Round Outlet and Round Inlet—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Blowers. High-Output Spark-Resistant Blowers.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC/230V AC
     
    Single Phase—Hardwire
    530 ft³/min @ 5 in. H₂O
    685 ft³/min @ 3 in. H₂O
    80 dBA @ 15 ft.3,4501 1/25"6"10 5/8"18"14 1/2"16 1/8"5517.8 amp/8.9 amp0 to 100AluminumNo7/16"1954K55000000000
     
    230V AC/460V AC
     
    Three Phase—Hardwire
    530 ft³/min @ 5 in. H₂O
    685 ft³/min @ 3 in. H₂O
    80 dBA @ 15 ft.3,4501 1/25"6"10 5/8"18"14 1/2"16 1/8"734.2 amp/2.1 amp0 to 100AluminumNo7/16"1954K7200000000
     

    Spark-Resistant Blowers

    These blowers have an aluminum housing for spark resistance. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water. It is the responsibility of users in California to follow local energy efficiency regulations. Operating these blowers at a high airflow may violate these regulations.
    With Round Outlet and Round Inlet—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Blowers. Spark-Resistant Blowers.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC/230V AC
     
    Single Phase—Hardwire
    995 ft³/min @ 1 in. H₂O
    1,070 ft³/min @ 1/4 in. H₂O
    70 dBA @ 15 ft.3,4501 1/26"6"6 1/4"14 1/8"12 1/4"13 1/4"13.2 amp/7.3 amp0 to 150AluminumNo7/16"1955K54000000000
     

    Chemical-Resistant Blowers

    For resistance to chemicals as well as corrosion, these blowers have a plastic housing. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    With Rectangular Outlet and Round Inlet—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Blowers. Chemical-Resistant Blowers, Rectangular Outlet.
    Image of Product. Front orientation. Blower Wheels. Chemical-Resistant Blowers.

    Replacement Wheels

    PVC Housing—PVC housing offers greater chemical resistance than the fiberglass housing. It resists strong oxidizing acids such as sulfuric acid but will not withstand contact with perchloric acid.
    Cannot Be Sold to California—Blowers that cannot be sold to the listed areas are restricted due to energy efficiency requirements.
    Blowers
    Replacement
    Wheels
    Outlet
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Ht.
    Wd.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Housing
    Material
    Fasteners
    Included
    Hole
    Dia.
    Cannot Be
    Sold To
    Each
    Each
    208V AC to 230V AC/460V AC
     
    Three Phase—Hardwire
    2,300 ft³/min @ 1/2 in. H₂O
    2,300 ft³/min @ 1 in. H₂O
    Not Rated1,7251 1/29 3/8"6 11/16"10"12"24 1/4"23"24 1/4"1244.5 amp/2.2 ampPVCNo3/8"California2093K750000000002093K36000000000
     

    Hazardous Location Spark-Resistant Blowers

    These blowers have an explosion-proof motor that is UL listed for hazardous locations. They also have an aluminum housing for spark resistance. These blowers install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water. It is the responsibility of users in California to follow local energy efficiency regulations. Operating these blowers at a high airflow may violate these regulations.
    With Round Outlet and Round Inlet
    Image of Product. Front orientation. Blowers. Hazardous Location Spark-Resistant Blowers.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Hazardous Location Rating
    Enclosure
    Rating
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC/230V AC
     
    Single Phase—Hardwire
    995 ft³/min @ 1 in. H₂O
    1,070 ft³/min @ 1/4 in. H₂O
    70 dBA @ 15 ft.3,4501 1/26"6"6 1/4"14 1/8"12 1/4"13 1/4"15.4 amp/8.4 amp0 to 150AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    IP54
    No7/16"1955K82000000000
     

    High-Output Hazardous Location Spark-Resistant Blowers

    Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard hazardous location spark-resistant blowers can handle. They have an explosion-proof motor that is UL listed for hazardous locations. They also have an aluminum housing for spark resistance. These blowers install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water. It is the responsibility of users in California to follow local energy efficiency regulations. Operating these blowers at a high airflow may violate these regulations.
    With Round Outlet and Round Inlet
    Image of Product. Front orientation. Blowers. High-Output Hazardous Location Spark-Resistant Blowers.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Hazardous Location Rating
    Fasteners
    Included
    Hole
    Dia.
    Each
    120V AC/230V AC
     
    Single Phase—Hardwire
    530 ft³/min @ 5 in. H₂O
    685 ft³/min @ 3 in. H₂O
    80 dBA @ 15 ft.3,4501 1/25"6"10 5/8"18"14 1/2"16 1/8"8815.0 amp/7.5 amp0 to 100AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    No7/16"1954K65000000000
     
    230V AC/460V AC
     
    Three Phase—Hardwire
    530 ft³/min @ 5 in. H₂O
    685 ft³/min @ 3 in. H₂O
    80 dBA @ 15 ft.3,4501 1/25"6"10 5/8"18"14 1/2"16 1/8"733.8 amp/1.9 amp0 to 100AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    No7/16"1954K7300000000
     

    Hazardous Location Chemical-Resistant Blowers

    These blowers have an explosion-proof motor that is UL listed and CSA certified for Class I, Divisions 1 and 2, Group D; and Class II, Divisions 1 and 2, Groups F and G hazardous locations. For resistance to chemicals as well as corrosion, they have a plastic housing. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    With Rectangular Outlet and Round Inlet
    Image of Product. Front orientation. Blowers. Hazardous Location Chemical-Resistant Blowers, Rectangular Outlet.
    Image of Product. Front orientation. Blower Wheels. Hazardous Location Chemical-Resistant Blowers.

    Replacement Wheels

    PVC Housing—PVC housing offers greater chemical resistance than the fiberglass housing. It resists strong oxidizing acids such as sulfuric acid but will not withstand contact with perchloric acid.
    Cannot Be Sold to California—Blowers that cannot be sold to the listed areas are restricted due to energy efficiency requirements.
    Blowers
    Replacement
    Wheels
    Outlet
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Ht.
    Wd.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Current
    Housing
    Material
    Hazardous Location Rating
    Fasteners
    Included
    Hole
    Dia.
    Cannot Be
    Sold To
    Each
    Each
    230V AC/460V AC
     
    Three Phase—Hardwire
    2,300 ft³/min @ 1/2 in. H₂O
    2,300 ft³/min @ 1 in. H₂O
    Not Rated1,7251 1/29 3/8"6 11/16"10"12"24 1/4"23"24 1/4"4.4 amp/2.2 ampPVCNEC Class I Divisions 1, 2 Group D
    NEC Class II Divisions 1, 2 Groups F, G
    No3/8"California2093K760000000002093K36000000000
     

    Portable Fume Exhausters

    Image of Product. Front orientation. Fume Exhausters. Portable Fume Exhausters.
    In addition to using the handle to carry these exhausters, you can mount them to a wall, bench, or floor. They remove fumes, vapors, and fine dust particles from your space. They are commonly used in welding, soldering, and other operations that create fumes. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments. They have a flexible hose with nozzle to capture fumes at the source and rubber pads on the base to reduce vibration.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Nozzle
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    Inlet
    Dia.
    Outlet
    Dia.
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Housing
    Material
    Wheel
    Material
    Fasteners
    Included
    For Screw
    Size
    Hole
    Dia.
    No. of
    Holes
    Hose Lg.,
    ft.
    Each
    Totally Enclosed Motor Enclosure
     
    120V AC/230V AC, Single Phase—Hardwire
    730 ft³/min @ 1 1/2 in. H₂O
    795 ft³/min @ 1/4 in. H₂O
    810 ft³/min @ 0 in. H₂O
    73 dBA @ 15 ft.1 1/26"6"21 3/8"21 1/2"16 1/2"8"8"SteelAluminum
    No3/8"
    7/16"4102111K14000000000
     
    230V AC/460V AC, Three Phase—Hardwire
    730 ft³/min @ 1 1/2 in. H₂O
    795 ft³/min @ 1/4 in. H₂O
    810 ft³/min @ 0 in. H₂O
    73 dBA @ 15 ft.1 1/26"6"21 3/8"21 1/2"16 1/2"8"8"SteelAluminum
    No3/8"
    7/16"4102111K1500000000
     
    Duct Kits

    Direct-Drive Exhaust Fans

    With fewer moving parts than belt-drive fans, these direct-drive exhaust fans require less maintenance. They have a built-in grease pan to collect waste while cooking. Mount these fans directly to your roof with the attached mounting brackets. They meet UL standards for ventilation in residential, commercial, and institutional kitchens.
    208V AC, Three Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Exhaust Fans.
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Overall
    Ht.
    Base
    Wd.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Blade
    Material
    Features
    Specs. Met
    Certification
    Each
    16"3,000 ft³/min @ 1/2 in. H₂O
    3,500 ft³/min @ 0 in. H₂O
    71 dB @ 5 ft.Direct1,650Variable1 1/259 3/4"32 5/8"350SteelAluminum
    Grease PanUL 705, UL 762, ULC-S645ETL Listed
    4706N13000000000
    19"3,800 ft³/min @ 1/2 in. H₂O
    4,500 ft³/min @ 0 in. H₂O
    76 dB @ 5 ft.Direct1,175Variable1 1/266 1/8"37 1/2"350SteelAluminum
    Grease PanUL 705, UL 762, ULC-S645ETL Listed
    4706N1400000000

    Belt-Drive Hazardous Location Duct Fans

    Image of Product. Front orientation. Duct Fans. Belt-Drive Hazardous Location Duct Fans.
    These fans have an explosion-proof motor that is rated for hazardous environments. All are belt-drive fans that are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. They install inline in ductwork for use as an exhaust, supply, or booster fan. UL and CSA standards apply to the motor.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    IP56 Enclosure Rating— Fans rated IP56 have a motor enclosure that’s rated for protection in damp, dusty, and washdown environments.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing
    Material
    Blade
    Material
    Certification
    Fasteners
    Included
    Hole
    Dia.
    Each
    230V AC, 460V AC, Three Phase—Hardwire
     
    IP56 Enclosure Rating
    24"17,000 ft³/min @ 3/8 in. H₂O
    7,900 ft³/min @ 1/8 in. H₂O
    70 dBA @ 15 ft.1,8001 1/226 11/16"36 11/16"12"175SteelAluminum
    UL Listed
    No7/16"2097K58000000000
     

    High-Output Blowers

    Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard blowers can handle. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, drying, ventilating, and exhausting. Blowers that weigh 280 lbs. or less can also be used for material conveying.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water. It is the responsibility of users in California to follow local energy efficiency regulations. Operating these blowers at a high airflow may violate these regulations.
    With Rectangular Outlet and Round Inlet—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Blowers. High-Output Blowers, Rectangular Outlet.
    Blowers with an open dripproof motor enclosure are for relatively clean, dry, indoor locations.
    Blowers
    Replacement
    Wheels
    Outlet
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Ht.
    Wd.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    Each
    120V AC/230V AC
     
    Single Phase—Hardwire
    505 ft³/min @ 4 1/2 in. H₂O
    635 ft³/min @ 3 1/4 in. H₂O
    74 dBA @ 15 ft.3,4501 1/25 5/8"3 5/8"6"10"17 3/4"15 3/8"14 5/8"5917.8 amp/8.9 amp-15 to 180SteelNo1/2"1953K1320000000001953K9220000000
     

    Belt-Drive Mobile Floor Fans

    Image of Product. Front orientation. Fans. Belt-Drive Mobile Floor Fans.
    Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged.
    Open Dripproof (ODP) Motor Enclosure—Fans with an open dripproof (ODP) motor enclosure are for relatively clean, dry, indoor locations.
    Blade
    Overall
    Dia.
    Material
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Cord Lg.,
    ft.
    Guard Material
    Each
    Open Dripproof (ODP) Motor Enclosure—Steel Housing
     
    120V AC, Single Phase—Three Blade Plug
    60"Steel30,100Not Rated37011 1/214.068"63"25"10Powder-Coated Steel2214K106000000000
     

    Belt-Drive Corrosion-Resistant Duct Fans

    Image of Product. Front orientation. Duct Fans. Belt-Drive Corrosion-Resistant Duct Fans.
    A 304 stainless steel housing offers good corrosion resistance. All of these belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. They install inline in ductwork for use as an exhaust, supply, or booster fan. The fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing Material
    Blade Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    230V AC, 460V AC, Three Phase—Hardwire
    18"14,600 ft³/min @ 3/8 in. H₂O
    4,800 ft³/min @ 1/8 in. H₂O
    65 dBA @ 15 ft.2,3501 1/220 1/16"32 11/16"20"200304 Stainless SteelStainless Steel
    No7/16"2357K37000000000
     

    Belt-Drive Duct Fans

    Image of Product. Front orientation. Duct Fans. Belt-Drive Duct Fans.
    Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Also known as axial duct fans, these install inline in ductwork for use as an exhaust, supply, or booster fan. All fans have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    For Duct
    Dia.
    No. of
    Speeds
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Dp.
    Max. Temp.,
    ° F
    Housing
    Material
    Blade
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    230V AC, 460V AC, Three Phase—Hardwire
    24"17,000 ft³/min @ 3/8 in. H₂O
    7,900 ft³/min @ 1/8 in. H₂O
    70 dBA @ 15 ft.1,8001 1/226 11/16"36 11/16"12"175SteelAluminum
    No7/16"2097K38000000000
     

    Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans

    Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area.
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans.
    Image of Product. Front orientation. Exhaust Fan Collars. Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans.

    Exhaust Fan Collars

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Each
    Each
    36"14,20068 dB @ 5 ft.Belt80011 1/242"42"19 1/8"SteelSteel1922K930000000005353K160000000

    Belt-Drive Downdraft Roof-Mount Exhaust Fans

    Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. More economical than upblast roof-mount exhaust fans, these draw stagnant and humid air out through your roof and then direct it back toward the roof.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    120V AC/208 to 230V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Belt-Drive Downdraft Roof-Mount Exhaust Fans .
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Housing
    Material
    Blade
    Material
    Features
    Each
    Each
    20"4,900 ft³/min @ 1/2 in. H₂O
    5,400 ft³/min @ 0 in. H₂O
    74 dBA @ 5 ft.Belt1,08011 1/238 1/4"31 3/4"30"Aluminum
    Aluminum
    Bird Screen2207K320000000002230K360000000

    Direct-Drive Wall-Mount Exhaust Fans with Louvers

    These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have an open dripproof (ODP) motor enclosure for relatively clean, dry, indoor locations. They also have a wire mesh inlet guard to protect the fan from debris.
    230/460V AC, Three Phase—Hardwire
    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Wall-Mount Exhaust Fans with Louvers.
    Cannot Be Sold to California—Fans that cannot be sold to California are restricted by local energy efficiency requirements.
    For
    Opening
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Frame Material
    Blade
    Material
    Features
    Certification
    Cannot Be
    Sold To
    Each
    36"12,30074 dBA @ 5 ft.Direct85011 1/243 1/4"43 1/4"45 1/2"45 1/2"31 1/2"SteelGalvanized SteelAluminum
    Wire Mesh Inlet GuardC-UL Listed, UL Listed
    California19105K42000000000

    Hazardous Location Exhaust Fans

    These fans have a motor that is UL listed for hazardous environments. Use them to draw stagnant and humid air out of a room or area.
    230/460V AC, Three Phase—Hardwire
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Exhaust Fans .
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Add a collar (sold separately) to connect a wall-mount fan these fans to a louver.
    Cannot Be Sold to California—Fans that cannot be sold to California do not meet energy efficiency requirements.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Blade
    Material
    Certification
    Hazardous Location Rating
    Cannot Be
    Sold To
    Each
    Each
    30"11,00077 dBA @ 5 ft.Direct1,12511 1/236 1/8"36 1/8"29 1/4"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    California2208K540000000005353K270000000

    Jet-Stream Floor Fans

    Often used to cool warehouse aisles and production lines, these fans generate a stream of air that travels farther than air from conventional fans.They have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Without Wheels—Hardwire
    Image of Product. Front orientation. Fans. Jet-Stream Floor Fans.
    Drive Type—Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
    Blade
    Overall
    Dia.
    Material
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Current
    Ht.
    Wd.
    Dp.
    Fan Head
    Movement
    Housing
    Material
    Guard
    Material
    Drive
    Type
    Each
    120/230V AC, Single Phase
    30"Aluminum11,00077 dBA @ 5 ft.1,75011 1/214.6 amp 7.4 amp34"30"20"Non-OscillatingSteelSteelDirect2029K9000000000
     
    back to top