    High-Output Blowers

    Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard blowers can handle. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, drying, ventilating, and exhausting. Blowers that weigh 280 lbs. or less can also be used for material conveying.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water. It is the responsibility of users in California to follow local energy efficiency regulations. Operating these blowers at a high airflow may violate these regulations.
    With Round Outlet and Round Inlet—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Blowers. High-Output Blowers, Round Outlet.
    Blowers with a totally enclosed motor enclosure can be used in dirty, dusty, and wet environments.
    Blowers
    Replacement
    Wheels
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    Each
    230V AC/460V AC
     
    Three Phase—Hardwire
    1,500 ft³/min @ 5 in. H₂O
    1,900 ft³/min @ 3 in. H₂O
    75 dBA @ 15 ft.3,45058"8"14"26 1/8"23 3/4"25 1/4"17611.8 amp/5.9 amp-10 to 150SteelNo7/16"1953K670000000001953K840000000
     
    With Rectangular Outlet and Round Inlet—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Blowers. High-Output Blowers, Rectangular Outlet.
    Blowers with a totally enclosed motor enclosure can be used in dirty, dusty, and wet environments.
    Blowers
    Replacement
    Wheels
    Outlet
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Ht.
    Wd.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    Each
    230V AC/460V AC
     
    Three Phase—Hardwire
    1,600 ft³/min @ 4 1/2 in. H₂O
    1,800 ft³/min @ 3 1/4 in. H₂O
    73 dBA @ 15 ft.3,55057"5 5/8"8"12"22 1/4"20 9/16"17 5/8"22411.8 amp/5.9 amp-15 to 180SteelNo1/2"1953K1380000000001953K9330000000
    3,245 ft³/min @ 5 in. H₂O
    3,875 ft³/min @ 3 in. H₂O
    65 dBA @ 15 ft.3,450510 3/8"15 1/4"14 5/8"13 1/2"28 3/16"25 1/16"28 1/4"31411.8 amp/5.9 amp-15 to 180SteelNo9/16"1953K46000000001953K10500000000
     
    With Rectangular Outlet and Round Inlet—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Blowers. High-Output Blowers, Rectangular Outlet.
    Blowers with an open dripproof motor enclosure are for relatively clean, dry, indoor locations.
    Blowers
    Replacement
    Wheels
    Outlet
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Ht.
    Wd.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    Each
    230V AC/460V AC
     
    Three Phase—Hardwire
    1,600 ft³/min @ 4 1/4 in. H₂O
    1,800 ft³/min @ 3 1/4 in. H₂O
    73 dBA @ 15 ft.3,45057"5 5/8"8"12"22 1/4"20 9/16"17 5/8"19712.6 amp/6.32 amp-15 to 180SteelNo1/2"1953K1330000000001953K9330000000
     

    High-Output Spark-Resistant Blowers

    Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard spark-resistant blowers can handle. They have an aluminum housing for spark resistance. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    With Round Outlet and Round Inlet—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Blowers. High-Output Spark-Resistant Blowers.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    230V AC/460V AC
     
    Three Phase—Hardwire
    1,240 ft³/min @ 5 in. H₂O
    1,400 ft³/min @ 3 in. H₂O
    74 dBA @ 15 ft.3,45056"7"13"21 5/16"18 1/2"18 1/2"16211.8 amp/5.9 amp-10 to 150AluminumNo7/16"1954K88000000000
    1,600 ft³/min @ 5 in. H₂O
    1,890 ft³/min @ 3 in. H₂O
    76 dBA @ 15 ft.3,45058"8"14"26"22 1/16"22 3/16"21311.8 amp/5.9 amp-10 to 150AluminumNo7/16"1954K8900000000
     

    High-Output Hazardous Location Spark-Resistant Blowers

    Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard hazardous location spark-resistant blowers can handle. They have an explosion-proof motor that is UL listed for hazardous locations. They also have an aluminum housing for spark resistance. These blowers install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water. It is the responsibility of users in California to follow local energy efficiency regulations. Operating these blowers at a high airflow may violate these regulations.
    With Round Outlet and Round Inlet
    Image of Product. Front orientation. Blowers. High-Output Hazardous Location Spark-Resistant Blowers.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Temp. Range,
    ° F
    Housing
    Material
    Hazardous Location Rating
    Fasteners
    Included
    Hole
    Dia.
    Each
    230V AC/460V AC
     
    Three Phase—Hardwire
    1,400 ft³/min @ 3 in. H₂O74 dBA @ 15 ft.3,45056"7"13"21 5/16"18 1/2"21 3/4"18312.2 amp/6.1 amp-10 to 150AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    No7/16"1954K107000000000
    1,890 ft³/min @ 3 in. H₂O76 dBA @ 15 ft.3,45058"8"14"26 5/8"22 3/16"24 7/16"23412.2 amp/6.1 amp-10 to 150AluminumNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    No7/16"1954K10800000000
     

    Corrosion-Resistant Blowers

    A 304 stainless steel housing offers good corrosion resistance. These blowers install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    With Rectangular Outlet and Round Inlet—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Blowers. Corrosion-Resistant Blowers.
    Blowers
    Replacement
    Wheels
    Outlet
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Ht.
    Wd.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Current
    Temp. Range,
    ° F
    Housing Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    Each
    230V AC/460V AC
     
    Three Phase—Hardwire
    1,600 ft³/min @ 4 1/2 in. H₂O
    1,800 ft³/min @ 3 1/4 in. H₂O
    73 dBA @ 15 ft.3,55057"5 5/8"5"12"22 1/4"20 9/16"17 5/8"11.8 amp/5.9 amp-15 to 180304 Stainless SteelNo1/2"2283K320000000001953K9330000000
     

    High-Flow Low-Pressure Compressed Air Blowers

    Also known as regenerative blowers, use these to produce high-flow compressed air with low pressure or vacuum to operate pump drives, lift tables, and conveying systems. Compressed air blowers are also used for drying, exhausting, and aeration.
    Air circulates inside the blower housing to compress air, which generates pressure or vacuum.
    Single Stage
    Image of Product. Front orientation. Blowers. High-Flow Low-Pressure Compressed Air Blowers, Single Stage.
    Single-stage blowers circulate air once and then exhaust.
    Inverter Rated—Inverter-rated blowers have a motor that can run at slow speeds without overheating, so they can be used with a motor speed control (variable frequency drive).
    Blowers
    Air Intake
    Filters
    Valves
    Overall
    Pipe
    Size
    Max. Pressure
    Max. Flow Rate
    @ Pressure
    Vacuum Rating
    Power,
    hp
    Full Load Current @ Voltage
    Volume (Sound),
    dBA
    Lg.
    Wd.
    Ht.
    Temp. Range,
    ° F
    Inlet
    Outlet
    Each
    Each
    Each
    Three Phase, 208/230/460V AC (Inverter Rated)
     
    NPT Female Inlet and Outlet
    4 psi
    105 in. H₂O
    207 ft³/min @ 0 psi6.5 in. Hg
    88 in. H₂O
    513 amp @ 208V AC
    12 amp @ 230V AC
    6 amp @ 460V AC
    7219"15"15"32 to 1002
    2
    9960K630000000009960K82600000009960K8210000000
     

    Chemical-Resistant Blowers

    For resistance to chemicals as well as corrosion, these blowers have a plastic housing. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    With Rectangular Outlet and Round Inlet—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Blowers. Chemical-Resistant Blowers, Rectangular Outlet.
    Image of Product. Front orientation. Blower Wheels. Chemical-Resistant Blowers.

    Replacement Wheels

    PVC Housing—PVC housing offers greater chemical resistance than the fiberglass housing. It resists strong oxidizing acids such as sulfuric acid but will not withstand contact with perchloric acid.
    Cannot Be Sold to California—Blowers that cannot be sold to the listed areas are restricted due to energy efficiency requirements.
    Blowers
    Replacement
    Wheels
    Outlet
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Ht.
    Wd.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Housing
    Material
    Fasteners
    Included
    Hole
    Dia.
    Cannot Be
    Sold To
    Each
    Each
    208V AC to 230V AC/460V AC
     
    Three Phase—Hardwire
    4,700 ft³/min @ 1 in. H₂O
    4,900 ft³/min @ 1/2 in. H₂O
    Not Rated1,725511 7/8"9 3/4"13"14 1/2"31 1/2"30"29 3/4"17213.9 amp/6.7 ampPVCNo3/8"California2093K850000000002093K38000000000
     

    Direct-Drive Exhaust Fans

    With fewer moving parts than belt-drive fans, these direct-drive exhaust fans require less maintenance. They have a built-in grease pan to collect waste while cooking. Mount these fans directly to your roof with the attached mounting brackets. They meet UL standards for ventilation in residential, commercial, and institutional kitchens.
    208V AC, Three Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Exhaust Fans.
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Overall
    Ht.
    Base
    Wd.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Blade
    Material
    Features
    Specs. Met
    Certification
    Each
    31"7,000 ft³/min @ 1/2 in. H₂O
    8,500 ft³/min @ 0 in. H₂O
    72 dB @ 5 ft.Direct675Variable585 7/8"52 1/4"350SteelSteelGrease PanUL 705, UL 762, ULC-S645ETL Listed
    4706N17000000000

    Hazardous Location Upblast Roof-Mount Exhaust Fans

    With a UL-listed motor, these fans can be used in hazardous environments with combustible gases and dust to draw stagnant and humid air out through your roof, forcing it up and away from its surface.
    Belt Drive
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Upblast Roof-Mount Exhaust Fans.
    Belt-drive fans are quieter and last longer than direct-drive fans because their components can be replaced if they’re worn or damaged.
    Exhaust Fans
    Mounting Bases
    Overall
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Max. Ambient
    Temp., ° F
    Housing
    Material
    Hazardous Location Rating
    Each
    Each
    Totally Enclosed Motor Enclosure
     
    240/460V AC, Three Phase—Hardwire
    36"20,200 ft³/min @ 1/2 in. H₂O
    24,100 ft³/min @ 0 in. H₂O
    82 dBA @ 5 ft.1,750545"31"48"590100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N230000000002230K480000000
    42"22,400 ft³/min @ 1/2 in. H₂O
    27,800 ft³/min @ 0 in. H₂O
    78 dBA @ 5 ft.1,750551"34"54"720100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N24000000002230K49000000
    48"28,600 ft³/min @ 1/2 in. H₂O
    36,700 ft³/min @ 0 in. H₂O
    80 dBA @ 5 ft.1,750557"37"60"840100SteelNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    4746N25000000002230K26000000
     

    Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans

    Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area.
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Exhaust Fans. Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans.
    Image of Product. Front orientation. Exhaust Fan Collars. Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans.

    Exhaust Fan Collars

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Frame
    Material
    Blade
    Material
    Each
    Each
    54"37,60070 dB @ 5 ft.Belt5251560"60"23 1/2"SteelSteel1922K960000000005353K190000000

    Direct-Drive Upblast Roof-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Upblast Roof-Mount Exhaust Fans , Style 1.
    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Upblast Roof-Mount Exhaust Fans , Style 2.

    Style 1

    Style 2

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. These exhaust fans draw stagnant and humid air out through your roof and then expel it up and away from the roof surface. All fans have a disconnect switch to turn off the power for servicing.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Exhaust Fans
    Mounting Bases
    Overall
    Style
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Certification
    Each
    Each
    Open Dripproof (ODP) Motor Enclosure
     
    208 to 230V AC, Three Phase—Hardwire
    120 3/4"5,900 ft³/min @ 1/2 in. H₂O
    6,450 ft³/min @ 0 in. H₂O
    85 dBA @ 5 ft.1,425537 3/8"33 1/4"28"221300Aluminum
    AMCA Certified, ETL Listed
    2232K370000000002230K350000000
    130"9,500 ft³/min @ 1/2 in. H₂O
    10,500 ft³/min @ 0 in. H₂O
    71 dBA @ 5 ft.725551 1/4"44"40"497300Aluminum
    AMCA Certified, ETL Listed
    2232K39000000002230K94000000
     
    Totally Enclosed Motor Enclosure
     
    460V AC, Three Phase—Hardwire
    248"25,500 ft³/min @ 1/2 in. H₂O
    34,300 ft³/min @ 0 in. H₂O
    76 dBA @ 5 ft.1,150556"38 3/4"60"650120Steel2081K17000000002230K26000000
     

    Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans

    Image of Product. Back orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 5.

    Style 5

    Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
    230/460V AC, Three Phase (Hardwire)—Totally Enclosed Motor Enclosure
    Image of Product. Back orientation. Exhaust Fans. Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans, Style 5.

    Style 5

    Exhaust Fan Collars—Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Style
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Frame
    Material
    Blade
    Material
    Each
    Each
    536"20,30083 dB @ 5 ft.Direct1,7501542"42"15 3/4"225104SteelSteel2222K140000000005353K160000000
    542"26,60080 dB @ 5 ft.Direct1,1501548"48"20"295104SteelSteel2222K17000000005353K17000000

    Direct-Drive Downdraft Roof-Mount Exhaust Fans

    Image of Product. Front orientation. Exhaust Fans. Direct-Drive Downdraft Roof-Mount Exhaust Fans, Style 2.

    Style 2

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. More economical than upblast roof-mount exhaust fans, these draw stagnant and humid air out through your roof and then direct it back toward the roof. All fans have a disconnect switch to turn off the power for servicing.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Exhaust Fans
    Mounting Bases
    Overall
    Style
    Blade
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Dia.
    Ht.
    Base
    Wd.
    Wt.,
    lb.
    Ambient
    Temp., ° F
    Housing
    Material
    Certification
    Each
    Each
    Open Dripproof (ODP) Motor Enclosure
     
    208/230V AC Three Phase—Hardwire
    221"6,200 ft³/min @ 1/2 in. H₂O
    6,700 ft³/min @ 0 in. H₂O
    82 dBA @ 5 ft.1,400538 15/16"32 1/4"28"201120Aluminum
    AMCA Certified, ETL Listed
    2011K240000000002230K350000000
    230"10,400 ft³/min @ 1/2 in. H₂O
    11,500 ft³/min @ 0 in. H₂O
    69 dBA @ 5 ft.700552 13/16"44"40"467120Aluminum
    AMCA Certified, ETL Listed
    2011K26000000002230K94000000
    236"11,000 ft³/min @ 1/2 in. H₂O
    13,500 ft³/min @ 0 in. H₂O
    64 dBA @ 5 ft.450563 5/16"49 1/2"44"532120Aluminum
    AMCA Certified, ETL Listed
    2011K27000000002230K57000000
     