Filter by
Maximum Pressure
Power Source
Maximum Flow Rate @ Pressure
Vacuum Rating
Full Load Current @ Voltage
Stage
Outlet Thread Type
Inlet Thread Type
Frequency
Mobility
Maximum Temperature
DFARS Specialty Metals
Export Control Classification Number (ECCN)
REACH
About Air Compressors
More
High-Flow Low-Pressure Compressed Air Blowers
Also known as regenerative blowers, use these to produce high-flow compressed air with low pressure or vacuum to operate pump drives, lift tables, and conveying systems. Compressed air blowers are also used for drying, exhausting, and aeration.
Air circulates inside the blower housing to compress air, which generates pressure or vacuum. Single-stage blowers circulate air once and then exhaust.
Inverter-rated blowers have a motor that can run at slow speeds without overheating, so they can be used with a motor speed control (variable frequency drive).
For technical drawings and 3-D models, click on a part number.
Single Stage

Single Stage Blower
Blowers | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Pipe Size | Air-Intake Filters | Relief Valves | ||||||||||||||
Maximum Pressure | Max. Flow Rate @ psi | Vacuum Rating | hp | Full Load Current | Vol. | Lg. | Wd. | Ht. | Temp. Range, °F | Inlet | Outlet | Each | Each | Each | |||
Single Phase, 120/208/230V AC | |||||||||||||||||
NPT Female Inlet and Outlet | |||||||||||||||||
1 psi 29 in. of H₂O | 27 cfm @ 0 | 1.9 in. of Hg 27 in. of H₂O | 1/8 | 2.3 A @ 115 V AC 1.2 A @ 208 V AC 1.2 A @ 230 V AC | 57 dBA | 9" | 8" | 9" | 32° to 100° | 1 | 1 | 0000000 | 0000000 | 00000000 | 0000000 | 00000000 | 0000000 |
1 psi 39 in. of H₂O | 42 cfm @ 0 | 2.6 in. of Hg 35 in. of H₂O | 1/3 | 3.8 A @ 115 V AC 2.0 A @ 208 V AC 1.9 A @ 230 V AC | 63 dBA | 10" | 9" | 9" | 32° to 100° | 1 | 1 | 0000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
2 psi 65 in. of H₂O | 127 cfm @ 0 | 4.4 in. of Hg 60 in. of H₂O | 1 1/2 | 17.5 A @ 115 V AC 10.0 A @ 208 V AC 9.0 A @ 230 V AC | 74 dBA | 16" | 13" | 14" | 32° to 100° | 1 1/2 | 1 1/2 | 0000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
Three Phase, 208/230/460V AC | |||||||||||||||||
NPT Female Inlet and Outlet | |||||||||||||||||
2 psi 65 in. of H₂O | 127 cfm @ 0 | 4.4 in. of Hg 60 in. of H₂O | 1 1/2 | 5.1 A @ 208 V AC 4.9 A @ 230 V AC 2.5 A @ 460 V AC | 74 dBA | 14" | 13" | 14" | 32° to 100° | 1 1/2 | 1 1/2 | 0000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
Three Phase, 208/230/460V AC (Inverter Rated) | |||||||||||||||||
NPT Female Inlet and Outlet | |||||||||||||||||
4 psi 105 in. of H₂O | 207 cfm @ 0 | 6.5 in. of Hg 88 in. of H₂O | 5 | 13.0 A @ 208 V AC 12.0 A @ 230 V AC 6.0 A @ 460 V AC | 72 dBA | 19" | 15" | 15" | 32° to 100° | 2 | 2 | 0000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |
5 psi 125 in. of H₂O | 420 cfm @ 0 | 8.1 in. of Hg 110 in. of H₂O | 10 | 35.0 A @ 208 V AC 29.5 A @ 230 V AC 15.0 A @ 460 V AC | 78 dBA | 22" | 18" | 20" | 32° to 100° | 2 1/2 | 2 1/2 | 0000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 |