About Exhaust Fans
More
About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
About Air Compressors
More
Hazardous Location Upblast Roof-Mount Exhaust Fans

With a UL-listed motor, these fans can be used in hazardous environments with combustible gases and dust to draw stagnant and humid air out through your roof, forcing it up and away from its surface.
Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
Belt-drive fans are quieter and last longer than direct-drive fans because their components can be replaced if they’re worn or damaged.
For technical drawings and 3-D models, click on a part number.
Fans | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Bases | ||||||||||||||
Blade Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Base Wd. | Wt., lbs. | Max. Ambient Temp., °F | Housing Material | Environmental Rating | Each | Each | ||
Totally Enclosed Motor Enclosure | |||||||||||||||
120/240V AC, Single Phase—Hardwire | |||||||||||||||
24" | 3,900 cfm @ 1/2 in. of H₂O 6,900 cfm @ 0 in. of H₂O | 75 dBA @ 5 ft. | 1,150 | 3/4 | 33" | 25" | 36" | 340 | 100° | Steel | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G | 0000000 | 000000000 | 0000000 | 0000000 |
30" | 5,900 cfm @ 1/2 in. of H₂O 9,350 cfm @ 0 in. of H₂O | 72 dBA @ 5 ft. | 1,150 | 1 | 39" | 28" | 42" | 370 | 100° | Steel | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G | 0000000 | 00000000 | 0000000 | 000000 |
240/460V AC, Three Phase—Hardwire | |||||||||||||||
36" | 15,700 cfm @ 1/2 in. of H₂O 21,000 cfm @ 0 in. of H₂O | 79 dBA @ 5 ft. | 1,150 | 3 | 45" | 31" | 48" | 480 | 100° | Steel | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G | 0000000 | 00000000 | 0000000 | 000000 |
42" | 19,400 cfm @ 1/2 in. of H₂O 25,300 cfm @ 0 in. of H₂O | 80 dBA @ 5 ft. | 1,150 | 3 | 51" | 34" | 54" | 520 | 100° | Steel | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G | 0000000 | 00000000 | 0000000 | 000000 |
48" | 31,600 cfm @ 1/2 in. of H₂O 36,200 cfm @ 0 in. of H₂O | 89 dBA @ 5 ft. | 1,150 | 7 1/2 | 57" | 37" | 60" | 670 | 100° | Steel | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G | 0000000 | 00000000 | 0000000 | 000000 |
Fans | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Bases | ||||||||||||||
Blade Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Base Wd. | Wt., lbs. | Max. Ambient Temp., °F | Housing Material | Environmental Rating | Each | Each | ||
Totally Enclosed Motor Enclosure | |||||||||||||||
120/240V AC, Single Phase—Hardwire | |||||||||||||||
24" | 3,530 cfm @ 1/2 in. of H₂O 6,150 cfm @ 0 in. of H₂O | 71 dBA @ 5 ft. | 1,750 | 3/4 | 33" | 25" | 36" | 340 | 100° | Steel | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G | 0000000 | 000000000 | 0000000 | 0000000 |
30" | 2,950 cfm @ 1/2 in. of H₂O 9,800 cfm @ 0 in. of H₂O | 68 dBA @ 5 ft. | 1,750 | 3/4 | 39" | 28" | 42" | 410 | 100° | Steel | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G | 0000000 | 00000000 | 0000000 | 000000 |
240/460V AC, Three Phase—Hardwire | |||||||||||||||
36" | 20,200 cfm @ 1/2 in. of H₂O 24,100 cfm @ 0 in. of H₂O | 82 dBA @ 5 ft. | 1,750 | 5 | 45" | 31" | 48" | 590 | 100° | Steel | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G | 0000000 | 00000000 | 0000000 | 000000 |
42" | 22,400 cfm @ 1/2 in. of H₂O 27,800 cfm @ 0 in. of H₂O | 78 dBA @ 5 ft. | 1,750 | 5 | 51" | 34" | 54" | 720 | 100° | Steel | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G | 0000000 | 00000000 | 0000000 | 000000 |
48" | 28,600 cfm @ 1/2 in. of H₂O 36,700 cfm @ 0 in. of H₂O | 80 dBA @ 5 ft. | 1,750 | 5 | 57" | 37" | 60" | 840 | 100° | Steel | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G | 0000000 | 00000000 | 0000000 | 000000 |
Hazardous Location Exhaust Fans

These fans have a motor that is UL listed for hazardous environments. Use them to draw stagnant and humid air out of a room or area.
Belt-drive fans are quieter and last longer than direct-drive fans because their components can be replaced if they’re worn or damaged. They come with collars, so you can connect these fans to a louver.
For technical drawings and 3-D models, click on a part number.
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Drive Type | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Housing Material | Blade Material | Environmental Rating | Includes | Each | |
120/230V AC, Single Phase—Hardwire | |||||||||||||||
30" | 9,840 | 71 dBA @ 10 ft. | Belt | 1,725 | 1 | 3/4 | 34 3/4" | 34 3/4" | 30" | Steel | Aluminum | NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G | Collar | 0000000 | 000000000 |
36" | 11,000 | 72 dBA @ 10 ft. | Belt | 1,725 | 1 | 3/4 | 40 3/4" | 40 3/4" | 30" | Steel | Aluminum | NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G | Collar | 0000000 | 00000000 |
42" | 14,600 | 74 dBA @ 10 ft. | Belt | 1,725 | 1 | 3/4 | 46 3/4" | 46 3/4" | 30" | Steel | Aluminum | NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G | Collar | 0000000 | 00000000 |
48" | 19,100 | 70 dBA @ 10 ft. | Belt | 1,725 | 1 | 3/4 | 52 3/4" | 52 3/4" | 30" | Steel | Aluminum | NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G | Collar | 0000000 | 00000000 |
High-Flow Low-Pressure Hazardous Location Compressed Air Blowers

Safely produce high-flow compressed air with low pressure or vacuum in environments with flammable gases and combustible dust, such as propane and carbon-based dust. These blowers have an explosion-proof motor and are UL listed for use in hazardous locations. Also known as regenerative blowers, they are commonly used to operate pump drives, lift tables, and conveying systems. They can also be used for drying, exhausting, and aerating.
For technical drawings and 3-D models, click on a part number.
Overall | Pipe Size | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Pressure | Max. Flow Rate | Vacuum Rating | hp | Full Load Current | Vol., dBA | Lg. | Wd. | Ht. | Temp. Range, °F | Inlet | Outlet | Environmental Rating | Each | |
Three Phase, 208V AC/230V AC/460V AC (Inverter Rated) | ||||||||||||||
NPT Female Inlet and Outlet | ||||||||||||||
2 psi 50 in. of H2O | 556 cfm @ 0 psi | 3.7 in. of Hg 50 in. of H2O | 10 | 24.3 A @ 208 V AC 22.4 A @ 230 V AC 11.2 A @ 460 V AC | 81 | 25" | 20" | 22" | 5° to 100° | 4 | 4 | NEC Class I Division 1 Group D; NEC Class II Division 2 Groups F, G | 0000000 | 000000000 |
2 psi 60 in. of H2O | 471 cfm @ 0 psi | 4.4 in. of Hg 60 in. of H2O | 10 | 24.3 A @ 208 V AC 22.4 A @ 230 V AC 11.2 A @ 460 V AC | 81 | 25" | 19" | 22" | 5° to 100° | 4 | 4 | NEC Class I Division 1 Group D; NEC Class II Division 2 Groups F, G | 0000000 | 00000000 |
2 psi 68 in. of H2O | 381 cfm @ 0 psi | 5 in. of Hg 68 in. of H2O | 7 1/2 | 18.9 A @ 208 V AC 17.8 A @ 230 V AC 8.9 A @ 460 V AC | 80 | 23" | 18" | 19" | 5° to 100° | 3 | 3 | NEC Class I Division 1 Group D; NEC Class II Division 2 Groups F, G | 0000000 | 00000000 |
4 psi 116 in. of H2O | 294 cfm @ 0 psi | 8.8 in. of Hg 116 in. of H2O | 7 1/2 | 18.9 A @ 208 V AC 17.8 A @ 230 V AC 8.9 A @ 460 V AC | 80 | 23" | 16" | 19" | 5° to 100° | 3 | 3 | NEC Class I Division 1 Group D; NEC Class II Division 2 Groups F, G | 0000000 | 00000000 |
Overall | Pipe Size | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Pressure | Max. Flow Rate | Vacuum Rating | hp | Full Load Current | Vol., dBA | Lg. | Wd. | Ht. | Temp. Range, °F | Inlet | Outlet | Environmental Rating | Each | |
Three Phase, 208V AC/230V AC/460V AC (Inverter Rated) | ||||||||||||||
NPT Female Inlet and Outlet | ||||||||||||||
2 psi 115 in. of H2O | 274 cfm @ 0 psi | 8.5 in. of Hg 115 in. of H2O | 10 | 24.3 A @ 208 V AC 22.4 A @ 230 V AC 11.2 A @ 460 V AC | 81 | 27" | 20" | 22" | 5° to 100° | 4 | 4 | NEC Class I Division 1 Group D; NEC Class II Division 2 Groups F, G | 0000000 | 000000000 |
3 psi 110 in. of H2O | 220 cfm @ 0 psi | 8.1 in. of Hg 110 in. of H2O | 7 1/2 | 18.9 A @ 208 V AC 17.8 A @ 230 V AC 8.9 A @ 460 V AC | 78 | 27" | 19" | 22" | 5° to 100° | 4 | 4 | NEC Class I Division 1 Group D; NEC Class II Division 2 Groups F, G | 0000000 | 00000000 |
5 psi 150 in. of H2O | 167 cfm @ 0 psi | 11 in. of Hg 150 in. of H2O | 7 1/2 | 18.9 A @ 208 V AC 17.8 A @ 230 V AC 8.9 A @ 460 V AC | 77 | 23" | 18" | 19" | 5° to 100° | 2 | 2 | NEC Class I Division 1 Group D; NEC Class II Division 2 Groups F, G | 0000000 | 00000000 |
8 psi 240 in. of H2O | 128 cfm @ 0 psi | 11.9 in. of Hg 240 in. of H2O | 7 1/2 | 18.9 A @ 208 V AC 17.8 A @ 230 V AC 8.9 A @ 460 V AC | 75 | 27" | 16" | 19" | 5° to 100° | 2 | 2 | NEC Class I Division 1 Group D; NEC Class II Division 2 Groups F, G | 0000000 | 00000000 |