Filter by
Length
Flexibility
Shielding
Current @ Temperature
Wire Finish
Wire and Cable Use
Finish
DFARS Specialty Metals
Export Control Classification Number (ECCN)
About Wire and Cable
Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.
Outdoor Lead Wire
600V AC/600V DC
Per Ft. | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | Wire Strand Count | Current @ Temp. | OD | Temp. Range, ° F | Outer Jacket Material | Outer Jacket Color | Cable Designation | Certification | Flammability Rating | Choose a Length, ft. | 1-99 | 100-Up | |||
Stranded Wire | |||||||||||||||
| 6 | 273/30 | 105 amp @ 86° F | 0.47" | -55 to 220 | EPDM | Black | SC | CSA Certified, MSHA Accepted, UL Listed | UL 2556 FT5 | 10, 25, 50, 100 | 6584T17 | 00000 | 00000 | ||
| 4 | 429/30 | 140 amp @ 86° F | 0.51" | -55 to 220 | EPDM | Black | SC | CSA Certified, MSHA Accepted, UL Listed | UL 2556 FT5 | 10, 25, 50, 100 | 6584T16 | 0000 | 0000 | ||
| 2 | 676/30 | 190 amp @ 86° F | 0.58" | -55 to 220 | EPDM | Black | SC | CSA Certified, MSHA Accepted, UL Listed | UL 2556 FT5 | 10, 25, 50, 100 | 6584T15 | 0000 | 0000 | ||
| 1/0 | 1,042/30 | 260 amp @ 86° F | 0.6" | -55 to 220 | EPDM | Black | SC | CSA Certified, MSHA Accepted, UL Listed | UL 2556 FT5 | 10, 25, 50, 100 | 6584T14 | 0000 | 0000 | ||
| 2/0 | 1,316/30 | 300 amp @ 86° F | 0.65" | -55 to 220 | EPDM | Black | SC | CSA Certified, MSHA Accepted, UL Listed | UL 2556 FT5 | 10, 25, 50, 100 | 6584T13 | 00000 | 0000 | ||
| 4/0 | 2,062/30 | 405 amp @ 86° F | 0.77" | -55 to 220 | EPDM | Black | SC | CSA Certified, MSHA Accepted, UL Listed | UL 2556 FT5 | 10, 25, 50, 100 | 6584T11 | 00000 | 00000 | ||
2,000V AC
AWG | Current @ Temp. | OD | Max. Temp., ° F | Outer Jacket Material | Inner Insulation Material | Outer Jacket Color | Cable Designation | Certification | Flammability Rating | 10 ft. Long | 25 ft. Long | 50 ft. Long | 100 ft. Long | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Stranded Wire | ||||||||||||||||
| 12 | Not Rated | 0.21" | 190 | CPE | EPDM | Black | DLO, RHW-2 | MSHA Accepted, UL Listed | UL 2556 FT4 | 6584T24 | 000000 | 000000 | 000000 | 000000 | ||
| 10 | Not Rated | 0.27" | 190 | CPE | EPDM | Black | DLO, RHW-2 | MSHA Accepted, UL Listed | UL 2556 FT4 | 6584T25 | 00000 | 00000 | 00000 | 000000 | ||
| 8 | 55 amp @ 86° F | 0.33" | 190 | CPE | EPDM | Black | DLO, RHW-2 | CSA Certified, MSHA Accepted, UL Listed | UL 2556 FT4 | 6584T26 | 00000 | 00000 | 000000 | 000000 | ||
| 6 | 75 amp @ 86° F | 0.37" | 190 | CPE | EPDM | Black | DLO, RHW-2 | CSA Certified, MSHA Accepted, UL Listed | UL 2556 FT4 | 6584T27 | 00000 | 00000 | 000000 | 000000 | ||
| 4 | 95 amp @ 86° F | 0.44" | 190 | CPE | EPDM | Black | DLO, RHW-2 | CSA Certified, MSHA Accepted, UL Listed | UL 2556 FT4 | 6584T28 | 00000 | 000000 | 000000 | 000000 | ||
| 2 | 130 amp @ 86° F | 0.5" | 190 | CPE | EPDM | Black | DLO, RHW-2 | MSHA Accepted, UL Listed | UL 2556 FT4 | 6584T29 | 00000 | 000000 | 000000 | 000000 | ||
| 1/0 | 170 amp @ 86° F | 0.65" | 190 | CPE | EPDM | Black | DLO, RHW-2 | CSA Certified, MSHA Accepted, UL Listed | UL 2556 FT4 | 6584T31 | 000000 | 000000 | 000000 | 000000 | ||
| 2/0 | 195 amp @ 86° F | 0.69" | 190 | CPE | EPDM | Black | DLO, RHW-2 | MSHA Accepted, UL Listed | UL 2556 FT4 | 6584T32 | 000000 | 000000 | 000000 | 000000 | ||
| 4/0 | 260 amp @ 86° F | 0.82" | 190 | CPE | EPDM | Black | DLO, RHW-2 | MSHA Accepted, UL Listed | UL 2556 FT4 | 6584T33 | 000000 | 000000 | 000000 | 00000000 | ||
Corrosion-Resistant Battery Wire
Stranded Wire with PVC Outer Jacket
AWG | Wire Strand Count | Current @ Temp. | OD | Temp. Range, ° F | Outer Jacket Color | 25 ft. Long | 50 ft. Long | 100 ft. Long | |||
|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | |||||||||||
| 8 | 133/29 | Not Rated | 0.16" | 0 to 220 | Red | 6444N11 | — | 0000000 | 0000000 | ||
| 8 | 133/29 | Not Rated | 0.26" | 0 to 220 | Black | 6444N12 | — | 000000 | 000000 | ||
| 6 | 133/27 | Not Rated | 0.32" | 0 to 220 | Red | 6444N21 | 000000 | 000000 | 000000 | ||
| 6 | 266/27 | Not Rated | 0.32" | 0 to 220 | Black | 6444N22 | 00000 | 000000 | 000000 | ||
| 4 | 133/25 | Not Rated | 0.36" | 0 to 220 | Red | 6444N31 | 000000 | 000000 | 000000 | ||
| 4 | 420/25 | Not Rated | 0.37" | 0 to 220 | Black | 6444N32 | 000000 | 000000 | 000000 | ||
| 2 | 665/30 | Not Rated | 0.43" | 0 to 220 | Red | 6444N41 | 000000 | 000000 | 000000 | ||
| 2 | 665/30 | Not Rated | 0.47" | 0 to 220 | Black | 6444N42 | 000000 | 000000 | 000000 | ||
Harsh-Environment Power Cable
Outer Jacket | Per Ft. | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cable AWG | Current @ Temp. | Material | Color | Temp., ° F | Specs. Met | Certification | Choose a Length, ft. | 1-99 | 100-Up | |||
600V AC | ||||||||||||
Type P Cable | ||||||||||||
| 16/3 | 18 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K16 | 00000 | 00000 | ||
| 16/4 | 14 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K21 | 0000 | 0000 | ||
| 14/3 | 20 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K17 | 0000 | 0000 | ||
| 14/4 | 16 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K22 | 0000 | 0000 | ||
| 12/3 | 25 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K18 | 0000 | 0000 | ||
| 12/4 | 20 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K23 | 0000 | 0000 | ||
| 10/3 | 35 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K19 | 0000 | 0000 | ||
| 10/4 | 28 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K24 | 0000 | 0000 | ||
| 8/4 | 40 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K25 | 0000 | 0000 | ||
| 6/4 | 52 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K26 | 00000 | 00000 | ||
| 4/4 | 68 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 5, 10, 25, 50 | 8248K27 | 00000 | 00000 | ||
| 2/4 | 92 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 5, 10, 25, 50 | 8248K28 | 00000 | 00000 | ||
Type P Cable with Bronze Armor | ||||||||||||
| 16/3 | 18 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K46 | 0000 | 0000 | ||
| 16/4 | 14 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K51 | 0000 | 0000 | ||
| 14/3 | 20 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K47 | 0000 | 0000 | ||
| 14/4 | 16 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K52 | 0000 | 0000 | ||
| 12/3 | 25 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K48 | 0000 | 0000 | ||
| 12/4 | 20 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K53 | 0000 | 0000 | ||
| 10/3 | 35 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K49 | 00000 | 0000 | ||
| 10/4 | 28 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K54 | 00000 | 00000 | ||
| 8/4 | 40 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 10, 25, 50, 100 | 8248K55 | 00000 | 00000 | ||
| 6/4 | 52 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 5, 10, 25, 50 | 8248K56 | 00000 | 00000 | ||
| 4/4 | 68 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 5, 10, 25, 50 | 8248K57 | 00000 | 00000 | ||
| 2/4 | 92 amp @ 86° F | CPE | Black | -40 to 230 | UL 1309 | ABS Type Approved, CSA Certified, UL Listed | 5, 10, 25, 50 | 8248K58 | 00000 | 00000 | ||
Abrasion-Resistant Power Cable
Outer Jacket | Per Ft. | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cable AWG | Current @ Temp. | Material | Color | Temp., ° F | Flammability Rating | Certification | Choose a Length, ft. | 1-99 | 100-Up | |||
300V AC | ||||||||||||
Unshielded | ||||||||||||
| 24/2 | 2.3 amp @ 86° F | Polyurethane Rubber | Black | -20 to 190 | UL 2556 VW-1 | C-UL Recognized Component, UL Recognized Component | 5, 10, 25, 50, 100 | 8237K22 | 00000 | 00000 | ||
| 22/2 | 3.4 amp @ 86° F | Polyurethane Rubber | Black | -20 to 190 | UL 2556 VW-1 | C-UL Recognized Component, UL Recognized Component | 5, 10, 25, 50, 100 | 8237K21 | 0000 | 0000 | ||
| 20/2 | 5.6 amp @ 86° F | Polyurethane Rubber | Black | -20 to 190 | UL 2556 VW-1 | C-UL Recognized Component, UL Recognized Component | 5, 10, 25, 50, 100 | 8237K23 | 0000 | 0000 | ||
| 18/2 | 7.9 amp @ 86° F | Polyurethane Rubber | Black | -20 to 190 | UL 2556 VW-1 | C-UL Recognized Component, UL Recognized Component | 5, 10, 25, 50, 100 | 8237K11 | 0000 | 0000 | ||
| 18/4 | 6.3 amp @ 86° F | Polyurethane Rubber | Black | -20 to 190 | UL 2556 VW-1 | C-UL Recognized Component, UL Recognized Component | 5, 10, 25, 50, 100 | 8237K13 | 0000 | 0000 | ||
| 18/6 | 6.3 amp @ 86° F | Polyurethane Rubber | Black | -20 to 190 | UL 2556 VW-1 | C-UL Recognized Component, UL Recognized Component | 5, 10, 25, 50, 100 | 8237K15 | 00000 | 00000 | ||
| 18/15 | 3.9 amp @ 86° F | Polyurethane Rubber | Black | -20 to 190 | UL 2556 VW-1 | C-UL Recognized Component, UL Recognized Component | 5, 10, 25, 50, 100 | 8237K17 | 00000 | 00000 | ||
| 16/2 | 11.3 amp @ 86° F | Polyurethane Rubber | Black | -20 to 190 | UL 2556 VW-1 | C-UL Recognized Component, UL Recognized Component | 5, 10, 25, 50, 100 | 8237K24 | 0000 | 0000 | ||
Shielded | ||||||||||||
| 22/6 | 2.7 amp @ 86° F | Polyurethane Rubber | Black | -20 to 190 | UL 2556 VW-1 | C-UL Recognized Component, UL Recognized Component | 5, 10, 25, 50, 100 | 8237K19 | 00000 | 0000 | ||
Submersible Pump Cable
AWG | No. of Wires | Cable AWG | Current @ Temp. | OD | Outer Jacket Color | Temp. Range, ° F | Features | Cable Designation | Certification | Specs. Met | 10 ft. Long | 25 ft. Long | 50 ft. Long | 100 ft. Long | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Stranded Wire with TPE Outer Jacket | |||||||||||||||||
600V AC | |||||||||||||||||
| 12 | 3 | 12/3 | 20 amp @ 86° F | 0.46" | Black, Green, Red, Yellow | -55 to 140 | Insulated Ground Wire | THW | UL Listed | UL 83 | 6237N22 | 000000 | 000000 | 0000000 | 0000000 | ||
| 10 | 3 | 10/3 | 20 amp @ 86° F | 0.51" | Black, Green, Red, Yellow | -55 to 140 | Insulated Ground Wire | THW | UL Listed | UL 83 | 6237N23 | 00000 | 000000 | 000000 | 000000 | ||
Pendant Cable
Stranded Wire with Three Uninsulated Ground Wires
Inner Insulation | Per Ft. | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | No. of Wires | Cable AWG | Current @ Temp. | OD | Outer Jacket Color | Material | Color | Temp., ° F | Certification | Choose a Length, ft. | 1-99 | 100-Up | |||
600V AC | |||||||||||||||
| 12 | 3 | 12/3 | 25 amp @ 86° F | 0.42" | Gray | PVC | Black, Red, White | -40 to 140 | UL Listed | 10, 25, 50, 100, 250 | 7128K11 | 00000 | 00000 | ||
| 10 | 3 | 10/3 | 30 amp @ 86° F | 0.47" | Gray | PVC | Black, Red, White | -40 to 140 | UL Listed | 10, 25, 50, 100, 250 | 7128K13 | 0000 | 0000 | ||
| 8 | 3 | 8/3 | 40 amp @ 86° F | 0.63" | Gray | PVC | Black, Red, White | -40 to 140 | UL Listed | 10, 25, 50, 100 | 7128K15 | 0000 | 0000 | ||
Vehicle Wire
GPT Stranded Wire
AWG | Wire Strand Count | Current @ Temp. | OD | Outer Jacket Material | Temp. Range, ° F | Specs. Met | Lg., ft. | Choose an Outer Jacket Color | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
25V AC/60V DC | ||||||||||||
| 20 | 10/30 | 9 amp @ 86° F | 0.09" | PVC | -10 to 175 | SAE J1128 | 100 | Black, Blue, Green, Red, White, Yellow | 6659T64 | 000000 | ||
| 18 | 16/30 | 17 amp @ 86° F | 0.1" | PVC | -10 to 175 | SAE J1128 | 45 | Black, Blue, Green, Red, White, Yellow | 6659T58 | 0000 | ||
| 18 | 16/30 | 17 amp @ 86° F | 0.1" | PVC | -10 to 175 | SAE J1128 | 100 | Black, Blue, Green, Red, White, Yellow | 6659T54 | 00000 | ||
| 16 | 19/29 | 21 amp @ 86° F | 0.11" | PVC | -10 to 175 | SAE J1128 | 35 | Black, Blue, Green, Red, White, Yellow | 6659T48 | 0000 | ||
| 16 | 19/29 | 21 amp @ 86° F | 0.11" | PVC | -10 to 175 | SAE J1128 | 100 | Black, Blue, Green, Red, White, Yellow | 6659T44 | 00000 | ||
| 14 | 19/27 | 29 amp @ 86° F | 0.12" | PVC | -10 to 175 | SAE J1128 | 20 | Black, Blue, Green, Red, White, Yellow | 6659T38 | 0000 | ||
| 14 | 19/27 | 29 amp @ 86° F | 0.12" | PVC | -10 to 175 | SAE J1128 | 100 | Black, Blue, Green, Red, White, Yellow | 6659T34 | 00000 | ||
| 12 | 19/25 | 38 amp @ 86° F | 0.15" | PVC | -10 to 175 | SAE J1128 | 12 | Black, Blue, Green, Red, White, Yellow | 6659T28 | 0000 | ||
| 12 | 19/25 | 38 amp @ 86° F | 0.15" | PVC | -10 to 175 | SAE J1128 | 100 | Black, Blue, Green, Red, White, Yellow | 6659T24 | 00000 | ||
| 10 | 19/23 | 51 amp @ 86° F | 0.18" | PVC | -10 to 175 | SAE J1128 | 8 | Black, Blue, Green, Red, White, Yellow | 6659T18 | 0000 | ||
| 10 | 19/23 | 51 amp @ 86° F | 0.18" | PVC | -10 to 175 | SAE J1128 | 100 | Black, Blue, Green, Red, White, Yellow | 6659T14 | 00000 | ||
| 8 | 19/21 | 51 amp @ 86° F | 0.22" | PVC | -10 to 175 | SAE J1128 | 8 | Black, Red | 6659T6 | 0000 | ||
| 8 | 19/21 | 51 amp @ 86° F | 0.22" | PVC | -10 to 175 | SAE J1128 | 100 | Black, Red | 6659T8 | 00000 | ||
GXL Stranded Wire
AWG | Wire Strand Count | Current @ Temp. | OD | Outer Jacket Material | Temp. Range, ° F | Specs. Met | Lg., ft. | Choose an Outer Jacket Color | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
25V AC/60V DC | ||||||||||||
| 20 | 7/28 | 5 amp @ 86° F | 0.09" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Blue, Green, Red, White | 5980N1 | 00000 | ||
| 20 | 7/28 | 5 amp @ 86° F | 0.09" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 50 | Black, Blue, Green, Red, White | 5980N2 | 00000 | ||
| 20 | 7/28 | 5 amp @ 86° F | 0.09" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Blue, Green, Red, White | 5980N3 | 00000 | ||
| 20 | 7/28 | 5 amp @ 86° F | 0.09" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 250 | Black, Red, White | 5980N4 | 00000 | ||
| 20 | 7/28 | 5 amp @ 86° F | 0.09" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 500 | Black, Red, White | 5980N5 | 00000 | ||
| 18 | 16/30 | 5 amp @ 86° F | 0.09" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Blue, Green, Red, White | 5980N6 | 0000 | ||
| 18 | 16/30 | 5 amp @ 86° F | 0.09" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 50 | Black, Blue, Green, Red, White | 5980N7 | 00000 | ||
| 18 | 16/30 | 5 amp @ 86° F | 0.09" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Blue, Green, Red, White | 5980N8 | 00000 | ||
| 18 | 16/30 | 5 amp @ 86° F | 0.09" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 250 | Black, Red, White | 5980N9 | 00000 | ||
| 18 | 16/30 | 5 amp @ 86° F | 0.09" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 500 | Black, Red, White | 5980N211 | 00000 | ||
| 16 | 19/29 | 8 amp @ 86° F | 0.11" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Blue, Green, Red, White | 5980N212 | 0000 | ||
| 16 | 19/29 | 8 amp @ 86° F | 0.11" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 50 | Black, Blue, Green, Red, White | 5980N213 | 00000 | ||
| 16 | 19/29 | 8 amp @ 86° F | 0.11" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Blue, Green, Red, White | 5980N214 | 00000 | ||
| 16 | 19/29 | 8 amp @ 86° F | 0.11" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 250 | Black, Red, White | 5980N215 | 00000 | ||
| 16 | 19/29 | 8 amp @ 86° F | 0.11" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 500 | Black, Red, White | 5980N216 | 000000 | ||
| 14 | 19/27 | 11 amp @ 86° F | 0.12" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Blue, Green, Red, White | 5980N217 | 00000 | ||
| 14 | 19/27 | 11 amp @ 86° F | 0.12" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 50 | Black, Blue, Green, Red, White | 5980N218 | 00000 | ||
| 14 | 19/27 | 11 amp @ 86° F | 0.12" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Blue, Green, Red, White | 5980N219 | 00000 | ||
| 14 | 19/27 | 11 amp @ 86° F | 0.12" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 250 | Black, Red, White | 5980N311 | 00000 | ||
| 14 | 19/27 | 11 amp @ 86° F | 0.12" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 500 | Black, Red, White | 5980N312 | 000000 | ||
| 12 | 19/25 | 14 amp @ 86° F | 0.15" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Blue, Green, Red, White | 5980N313 | 00000 | ||
| 12 | 19/25 | 14 amp @ 86° F | 0.15" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 50 | Black, Blue, Green, Red, White | 5980N314 | 00000 | ||
| 12 | 19/25 | 14 amp @ 86° F | 0.15" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Blue, Green, Red, White | 5980N315 | 00000 | ||
| 12 | 19/25 | 14 amp @ 86° F | 0.15" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 250 | Black, Red, White | 5980N316 | 000000 | ||
| 12 | 19/25 | 14 amp @ 86° F | 0.15" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 500 | Black, Red, White | 5980N317 | 000000 | ||
| 10 | 19/23 | 23 amp @ 86° F | 0.18" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Blue, Green, Red, White | 5980N318 | 00000 | ||
| 10 | 19/23 | 23 amp @ 86° F | 0.18" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 50 | Black, Blue, Green, Red, White | 5980N319 | 00000 | ||
| 10 | 19/23 | 23 amp @ 86° F | 0.18" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Blue, Green, Red, White | 5980N321 | 00000 | ||
| 10 | 19/23 | 23 amp @ 86° F | 0.18" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 250 | Black, Red, White | 5980N322 | 000000 | ||
| 10 | 19/23 | 23 amp @ 86° F | 0.18" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 500 | Black, Red, White | 5980N323 | 000000 | ||
TXL Stranded Wire
AWG | Wire Strand Count | Current @ Temp. | OD | Outer Jacket Material | Temp. Range, ° F | Specs. Met | Lg., ft. | Choose an Outer Jacket Color | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
25V AC/60V DC | ||||||||||||
| 22 | 7/30 | 3 amp @ 86° F | 0.06" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Blue, Green, Red, White | 5979N1 | 00000 | ||
| 22 | 7/30 | 3 amp @ 86° F | 0.06" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 50 | Black, Blue, Green, Red, White | 5979N2 | 0000 | ||
| 22 | 7/30 | 3 amp @ 86° F | 0.06" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Blue, Green, Red, White | 5979N3 | 00000 | ||
| 22 | 7/30 | 3 amp @ 86° F | 0.06" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 250 | Black, Red, White | 5979N4 | 00000 | ||
| 22 | 7/30 | 3 amp @ 86° F | 0.06" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 500 | Black, Red, White | 5979N5 | 00000 | ||
| 20 | 7/28 | 5 amp @ 86° F | 0.07" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Blue, Green, Red, White | 5979N6 | 0000 | ||
| 20 | 7/28 | 5 amp @ 86° F | 0.07" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 50 | Black, Blue, Green, Red, White | 5979N7 | 0000 | ||
| 20 | 7/28 | 5 amp @ 86° F | 0.07" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Blue, Green, Red, White | 5979N8 | 00000 | ||
| 20 | 7/28 | 5 amp @ 86° F | 0.07" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 250 | Black, Red, White | 5979N9 | 00000 | ||
| 20 | 7/28 | 5 amp @ 86° F | 0.07" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 500 | Black, Red, White | 5979N211 | 00000 | ||
| 18 | 16/30 | 7 amp @ 86° F | 0.08" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Blue, Green, Red, White | 5979N212 | 0000 | ||
| 18 | 16/30 | 7 amp @ 86° F | 0.08" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 50 | Black, Blue, Green, Red, White | 5979N213 | 0000 | ||
| 18 | 16/30 | 7 amp @ 86° F | 0.08" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Blue, Green, Red, White | 5979N214 | 00000 | ||
| 18 | 16/30 | 7 amp @ 86° F | 0.08" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 250 | Black, Red, White | 5979N215 | 00000 | ||
| 18 | 16/30 | 7 amp @ 86° F | 0.08" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 500 | Black, Red, White | 5979N216 | 00000 | ||
| 16 | 19/29 | 10 amp @ 86° F | 0.09" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Blue, Green, Red, White | 5979N217 | 0000 | ||
| 16 | 19/29 | 10 amp @ 86° F | 0.09" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 50 | Black, Blue, Green, Red, White | 5979N218 | 00000 | ||
| 16 | 19/29 | 10 amp @ 86° F | 0.09" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Blue, Green, Red, White | 5979N219 | 00000 | ||
| 16 | 19/29 | 10 amp @ 86° F | 0.09" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 250 | Black, Red, White | 5979N311 | 00000 | ||
| 16 | 19/29 | 10 amp @ 86° F | 0.09" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 500 | Black, Red, White | 5979N312 | 000000 | ||
| 14 | 19/27 | 15 amp @ 86° F | 0.1" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Blue, Green, Red, White | 5979N313 | 00000 | ||
| 14 | 19/27 | 15 amp @ 86° F | 0.1" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 50 | Black, Blue, Green, Red, White | 5979N314 | 00000 | ||
| 14 | 19/27 | 15 amp @ 86° F | 0.1" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Blue, Green, Red, White | 5979N315 | 00000 | ||
| 14 | 19/27 | 15 amp @ 86° F | 0.1" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 250 | Black, Red, White | 5979N316 | 00000 | ||
| 14 | 19/27 | 15 amp @ 86° F | 0.1" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 500 | Black, Red, White | 5979N317 | 000000 | ||
| 12 | 19/25 | 20 amp @ 86° F | 0.13" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Blue, Green, Red, White | 5979N318 | 00000 | ||
| 12 | 19/25 | 20 amp @ 86° F | 0.13" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 50 | Black, Blue, Green, Red, White | 5979N319 | 00000 | ||
| 12 | 19/25 | 20 amp @ 86° F | 0.13" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Blue, Green, Red, White | 5979N411 | 00000 | ||
| 12 | 19/25 | 20 amp @ 86° F | 0.13" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 250 | Black, Red, White | 5979N412 | 000000 | ||
| 12 | 19/25 | 20 amp @ 86° F | 0.13" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 500 | Black, Red, White | 5979N413 | 000000 | ||
SXL Stranded Wire
AWG | Wire Strand Count | Current @ Temp. | OD | Outer Jacket Material | Temp. Range, ° F | Specs. Met | Lg., ft. | Choose an Outer Jacket Color | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
25V AC/60V DC | ||||||||||||
| 18 | 16/30 | 20 amp @ 86° F | 0.11" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Red | 6232N11 | 00000 | ||
| 18 | 16/30 | 20 amp @ 86° F | 0.11" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Red | 6232N21 | 00000 | ||
| 16 | 19/29 | 26 amp @ 86° F | 0.12" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Red | 6232N12 | 0000 | ||
| 16 | 19/29 | 26 amp @ 86° F | 0.12" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Red | 6232N22 | 00000 | ||
| 14 | 19/27 | 40 amp @ 86° F | 0.14" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Red | 6232N13 | 00000 | ||
| 14 | 19/27 | 40 amp @ 86° F | 0.14" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Red | 6232N23 | 00000 | ||
| 12 | 19/25 | 50 amp @ 86° F | 0.16" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Red | 6232N14 | 00000 | ||
| 12 | 19/25 | 50 amp @ 86° F | 0.16" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Red | 6232N24 | 00000 | ||
| 10 | 19/23 | 70 amp @ 86° F | 0.19" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 25 | Black, Red | 6232N15 | 00000 | ||
| 10 | 19/23 | 70 amp @ 86° F | 0.19" | Cross-Linked Polyethylene | -40 to 255 | SAE J1128 | 100 | Black, Red | 6232N25 | 00000 | ||
Moisture-Resistant Control Cable
Outer Jacket | Per Ft. | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cable AWG | Current @ Temp. | Material | Color | Cable Designation | Temp., ° F | Certification | Choose a Length, ft. | 1-249 | 250-Up | |||
300V AC | ||||||||||||
Unshielded | ||||||||||||
| 18/2 | 5 amp @ 86° F | PVC with Fiber Tape | Black | CL3 | 0 to 220 | UL Listed | 10, 25, 50, 100, 250 | 7000T32 | 00000 | 00000 | ||
| 18/4 | 7.2 amp @ 86° F | PVC with Fiber Tape | Black | CMG | 0 to 220 | UL Listed | 10, 25, 50, 100, 250 | 7000T33 | 0000 | 0000 | ||
| 16/4 | 9 amp @ 86° F | PVC with Fiber Tape | Black | CMG | 0 to 220 | UL Listed | 10, 25, 50, 100, 250 | 7000T34 | 0000 | 0000 | ||
| 14/2 | 8 amp @ 86° F | PVC with Fiber Tape | Black | CL3 | 0 to 220 | UL Listed | 10, 25, 50, 100, 250 | 7000T35 | 0000 | 0000 | ||
| 14/4 | 13 amp @ 86° F | PVC with Fiber Tape | Black | CL3 | 0 to 220 | UL Listed | 10, 25, 50, 100, 250 | 7000T36 | 0000 | 0000 | ||
| 12/2 | 12 amp @ 86° F | PVC with Fiber Tape | Black | CL3 | 0 to 220 | UL Listed | 10, 25, 50, 100, 250 | 7000T37 | 0000 | 0000 | ||
Irrigation Cable
AWG | No. of Wires | Cable AWG | OD | Outer Jacket Color | Inner Insulation Material | Inner Insulation Color | Temp. Range, ° F | Certification | 10 ft. Long | 25 ft. Long | 50 ft. Long | 100 ft. Long | 250 ft. Long | 500 ft. Long | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Solid Wire with Polyethylene Outer Jacket | |||||||||||||||||
30V AC/30V DC | |||||||||||||||||
| 18 | 2 | 18/2 | 0.2" | Black | Polypropylene | Red, White | 0 to 140 | UL Listed | 8070T11 | 00000 | 000000 | 000000 | 000000 | 000000 | 0000000 | ||
| 18 | 3 | 18/3 | 0.21" | Black | Polypropylene | Green, Red, White | 0 to 140 | UL Listed | 8070T12 | 00000 | 00000 | 00000 | 00000 | 000000 | 000000 | ||
| 18 | 4 | 18/4 | 0.23" | Black | Polypropylene | Blue, Green, Red, White | 0 to 140 | UL Listed | 8070T13 | 00000 | 00000 | 00000 | 00000 | 000000 | 000000 | ||
| 18 | 5 | 18/5 | 0.25" | Black | Polypropylene | Blue, Green, Red, White, Yellow | 0 to 140 | UL Listed | 8070T14 | 00000 | 00000 | 00000 | 00000 | 000000 | 000000 | ||
| 18 | 6 | 18/6 | 0.27" | Black | Polypropylene | Blue, Brown, Green, Red, White, Yellow | 0 to 140 | UL Listed | 8070T15 | 00000 | 00000 | 00000 | 00000 | 000000 | 000000 | ||
| 18 | 7 | 18/7 | 0.27" | Black | Polypropylene | Blue, Brown, Green, Orange, Red, White, Yellow | 0 to 140 | UL Listed | 8070T16 | 00000 | 00000 | 00000 | 00000 | 000000 | 000000 | ||
| 18 | 8 | 18/8 | 0.29" | Black | Polypropylene | Black, Blue, Brown, Green, Orange, Red, White, Yellow | 0 to 140 | UL Listed | 8070T17 | 00000 | 00000 | 00000 | 000000 | 000000 | 000000 | ||
| 18 | 9 | 18/9 | 0.31" | Black | Polypropylene | Black, Blue, Brown, Green, Orange, Pink, Red, White, Yellow | 0 to 140 | UL Listed | 8070T18 | 00000 | 00000 | 00000 | 000000 | 000000 | 000000 | ||
Fusible Link Wire
AWG | Wire Strand Count | OD | Max. Temp., ° F | Specs. Met | Outer Jacket Color | Lg., ft. | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|
Stranded Wire with Cross-Linked Polyethylene Outer Jacket | ||||||||||
12V DC | ||||||||||
| 18 | 19/23 | 0.02" | 300 | SAE J1128 | Blue | 8 | 6316N145 | 00000 | ||
| 18 | 19/23 | 0.02" | 300 | SAE J1128 | Blue | 100 | 6316N248 | 00000 | ||
| 16 | 19/30 | 0.04" | 300 | SAE J1128 | Black | 7 | 6316N154 | 0000 | ||
| 16 | 19/30 | 0.04" | 300 | SAE J1128 | Black | 100 | 6316N258 | 00000 | ||
| 14 | 19/28 | 0.08" | 300 | SAE J1128 | Gray | 6 | 6316N163 | 0000 | ||
| 14 | 19/28 | 0.08" | 300 | SAE J1128 | Gray | 100 | 6316N268 | 00000 | ||
| 12 | 19/25 | 0.12" | 300 | SAE J1128 | Blue | 4 | 6316N172 | 0000 | ||
| 12 | 19/25 | 0.12" | 300 | SAE J1128 | Blue | 100 | 6316N278 | 000000 | ||
| 10 | 16/18 | 0.2" | 300 | SAE J1128 | Red | 1 | 6316N181 | 0000 | ||
| 10 | 16/18 | 0.2" | 300 | SAE J1128 | Red | 75 | 6316N287 | 000000 | ||




























