McMaster-Carr logo
    Filter by
    American Wire Gauge (AWG)
    Industrial Info Compare
    Attribute Image
    Number of Wires
    Attribute Image
    Wire Construction
    Industrial Info Compare
    Outer Jacket Material
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    168 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Outdoor Lead Wire

    The EPDM insulation on this wire won’t become brittle or crack from sunlight, humidity, rain, temperature changes, abrasion from dirt and debris, and other rough outdoor conditions. It meets Mine Safety and Health Administration (MSHA) standards for material quality.
    600V AC/600V DC
    Image of Product. Side1 orientation. Lead Wire. Outdoor Lead Wire, 600V AC, 600V DC.
    SC Cable—SC wire is a good choice for temporary setups powering outdoor lights, equipment, generators, and power distribution boxes, since its thick insulation makes it easy to move and reuse. Commonly found at outdoor events, it’s also known as stage cable.
    UL 2556 FT5—All are flame rated, so they meets requirements for preventing the spread of flames based on a timed test. FT5 wire is suspended horizontally during testing.
    Per Ft.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Outer Jacket
    Color
    Cable
    Designation
    Certification
    Flammability
    Rating
    Choose a Length, ft.
    1-99
    100-Up
    Stranded Wire
    6
    273/30105 amp @ 86° F0.47"-55 to 220EPDMBlackSCCSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT5
    10, 25, 50, 1006584T170000000000
    4
    429/30140 amp @ 86° F0.51"-55 to 220EPDMBlackSCCSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT5
    10, 25, 50, 1006584T1600000000
    2
    676/30190 amp @ 86° F0.58"-55 to 220EPDMBlackSCCSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT5
    10, 25, 50, 1006584T1500000000
    1/0
    1,042/30
    260 amp @ 86° F0.6"-55 to 220EPDMBlackSCCSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT5
    10, 25, 50, 1006584T1400000000
    2/0
    1,316/30
    300 amp @ 86° F0.65"-55 to 220EPDMBlackSCCSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT5
    10, 25, 50, 1006584T13000000000
    4/0
    2,062/30
    405 amp @ 86° F0.77"-55 to 220EPDMBlackSCCSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT5
    10, 25, 50, 1006584T110000000000
     
    2,000V AC
    Image of Product. Side1 orientation. Lead Wire. Outdoor Lead Wire, 2,000V AC.
    DLO Cable—DLO wire carries higher voltages than SC wire, making it the better choice for heavy duty applications. Use it to run power to motors, cranes, and other equipment in shipyards, mines, and oil- and gas-drilling rigs. Also known as diesel locomotive cable, this wire was originally designed to wire trains. An outer layer of chlorinated polyethylene plastic (CPE) gives it increased resistance to chemicals, heat, and flames. It’s also rated RHW-2, so it can be used underground and in wet locations.
    UL 2556 FT4—All are flame rated, so they meets requirements for preventing the spread of flames based on a timed test. FT4 wire is mounted to a vertical tray during testing.
    AWG
    Current @
    Temp.
    OD
    Max. Temp.,
    ° F
    Outer Jacket
    Material
    Inner Insulation
    Material
    Outer Jacket
    Color
    Cable
    Designation
    Certification
    Flammability
    Rating
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    Stranded Wire
    12
    Not Rated0.21"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T24000000000000000000000000
    10
    Not Rated0.27"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T25000000000000000000000
    8
    55 amp @ 86° F0.33"190CPEEPDM
    BlackDLO, RHW-2CSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T260000000000000000000000
    6
    75 amp @ 86° F0.37"190CPEEPDM
    BlackDLO, RHW-2CSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T270000000000000000000000
    4
    95 amp @ 86° F0.44"190CPEEPDM
    BlackDLO, RHW-2CSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T2800000000000000000000000
    2
    130 amp @ 86° F0.5"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T2900000000000000000000000
    1/0
    170 amp @ 86° F0.65"190CPEEPDM
    BlackDLO, RHW-2CSA Certified, MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T31000000000000000000000000
    2/0
    195 amp @ 86° F0.69"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T32000000000000000000000000
    4/0
    260 amp @ 86° F0.82"190CPEEPDM
    BlackDLO, RHW-2MSHA Accepted, UL Listed
    UL 2556 FT4
    6584T3300000000000000000000000000
     

    Corrosion-Resistant Battery Wire

    Connect batteries in generators, forklifts, and other vehicles in corrosive environments. Also known as marine wire, this copper wire is tin plated to resist corrosion from salt water, battery acid, and oil. Designed for boats, it's a good choice for use outdoors. The PVC outer jacket stands up to fuel and oil. Wire strand count is the number of strands followed by the size of the individual strand.
    Stranded Wire with PVC Outer Jacket
    Image of Product. Front orientation. Battery Wire. Corrosion-Resistant Battery Wire.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Color
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    600V AC
    8
    133/29
    Not Rated0.16"0 to 220Red6444N1100000000000000
    8
    133/29
    Not Rated0.26"0 to 220Black6444N12000000000000
    6
    133/27
    Not Rated0.32"0 to 220Red6444N21000000000000000000
    6
    266/27Not Rated0.32"0 to 220Black6444N2200000000000000000
    4
    133/25
    Not Rated0.36"0 to 220Red6444N31000000000000000000
    4
    420/25Not Rated0.37"0 to 220Black6444N32000000000000000000
    2
    665/30Not Rated0.43"0 to 220Red6444N41000000000000000000
    2
    665/30Not Rated0.47"0 to 220Black6444N42000000000000000000
     

    Harsh-Environment Power Cable

    Transmit power in dirty, corrosive environments such as offshore rigs and ships. This cable is strong enough to resist crushing forces from heavy equipment. Its CPE jacket and tin-plated copper conductors maintain power in areas exposed to chemicals, oil, and salt water. It meets UL 1309 for high-performance marine cables, yet works just as well on land.
    Bronze Armor—A layer of bronze armor between the two outer jackets boosts resistance to abrasion, impact, and crushing.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Specs.
    Met
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Image of Product. Front orientation. Power Cable. Harsh-Environment Power Cable, Type P Cable.
    Type P Cable
    16/3
    18 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K160000000000
    16/4
    14 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K2100000000
    14/3
    20 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K1700000000
    14/4
    16 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K2200000000
    12/3
    25 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K1800000000
    12/4
    20 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K2300000000
    10/3
    35 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K1900000000
    10/4
    28 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K2400000000
    8/4
    40 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K2500000000
    6/4
    52 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K260000000000
    4/4
    68 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    5, 10, 25, 508248K270000000000
    2/4
    92 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    5, 10, 25, 508248K280000000000
     
    Image of Product. Front orientation. Power Cable. Harsh-Environment Power Cable, Type P Cable with Bronze Armor.
    Type P Cable with Bronze Armor
    16/3
    18 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K4600000000
    16/4
    14 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K5100000000
    14/3
    20 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K4700000000
    14/4
    16 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K5200000000
    12/3
    25 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K4800000000
    12/4
    20 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K5300000000
    10/3
    35 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K49000000000
    10/4
    28 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K540000000000
    8/4
    40 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K550000000000
    6/4
    52 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    5, 10, 25, 508248K560000000000
    4/4
    68 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    5, 10, 25, 508248K570000000000
    2/4
    92 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    5, 10, 25, 508248K580000000000
     

    Abrasion-Resistant Power Cable

    Image of Product. Front orientation. Power Cable. Abrasion-Resistant Power Cable, Unshielded.
    Image of Product. Front orientation. Power Cable. Abrasion-Resistant Power Cable, Shielded.

    Unshielded

    Shielded

    Pull this cable over rough surfaces without damage. The thick polyurethane jacket protects the wires inside and resists wear. It also stands up to moisture, oil, and chemicals.
    Shielded—Shielding stops these cables from acting as antennas that emit electromagnetic interference, which could disrupt nearby equipment such as control or data cables.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @ Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    300V AC
     
    Unshielded
    24/2
    2.3 amp @ 86° FPolyurethane Rubber
    Black-20 to 190UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    5, 10, 25, 50, 1008237K220000000000
    22/2
    3.4 amp @ 86° FPolyurethane Rubber
    Black-20 to 190UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    5, 10, 25, 50, 1008237K2100000000
    20/2
    5.6 amp @ 86° FPolyurethane Rubber
    Black-20 to 190UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    5, 10, 25, 50, 1008237K2300000000
    18/2
    7.9 amp @ 86° FPolyurethane Rubber
    Black-20 to 190UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    5, 10, 25, 50, 1008237K1100000000
    18/4
    6.3 amp @ 86° FPolyurethane Rubber
    Black-20 to 190UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    5, 10, 25, 50, 1008237K1300000000
    18/6
    6.3 amp @ 86° FPolyurethane Rubber
    Black-20 to 190UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    5, 10, 25, 50, 1008237K150000000000
    18/15
    3.9 amp @ 86° FPolyurethane Rubber
    Black-20 to 190UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    5, 10, 25, 50, 1008237K170000000000
    16/2
    11.3 amp @ 86° FPolyurethane Rubber
    Black-20 to 190UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    5, 10, 25, 50, 1008237K2400000000
     
    Shielded
    22/6
    2.7 amp @ 86° FPolyurethane Rubber
    Black-20 to 190UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    5, 10, 25, 50, 1008237K19000000000
     

    Submersible Pump Cable

    Image of Product. Side1 orientation. Submersible Pump Cable.
    Supply power to submersible pumps in water or oil wells. The TPE insulation holds up to moisture, chemicals, oil, and UV light, so this cable can be used outdoors. Also known as twisted pump cable, it can be used in grounded or ungrounded water well cable systems. The insulated ground wire is not counted in the number of wires.
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket Color
    Temp. Range,
    ° F
    Features
    Cable
    Designation
    Certification
    Specs.
    Met
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    Stranded Wire with TPE Outer Jacket
     
    600V AC
    12
    312/3
    20 amp @ 86° F0.46"Black, Green, Red, Yellow-55 to 140Insulated Ground WireTHWUL Listed
    UL 836237N2200000000000000000000000000
    10
    310/3
    20 amp @ 86° F0.51"Black, Green, Red, Yellow-55 to 140Insulated Ground WireTHWUL Listed
    UL 836237N2300000000000000000000000
     

    Pendant Cable

    Often used to wire pendant switches, this cable hangs from an overhead connection. It’s also known as bus drop cable.
    Stranded Wire with Three Uninsulated Ground Wires
    Image of Product. Front orientation. Pendant Cable. Stranded Wire with Three Uninsulated Ground Wires.
    Cable with three uninsulated ground wires can be used in wet environments. The ground wires are not counted in the number of wires.
    PVC Inner Insulation—The PVC insulation resists abrasion, chemicals, and oil.
    Inner
    Insulation
    Per Ft.
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Color
    Material
    Color
    Temp.,
    ° F
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
    12
    312/3
    25 amp @ 86° F0.42"GrayPVC
    Black, Red, White-40 to 140UL Listed
    10, 25, 50, 100, 2507128K110000000000
    10
    310/3
    30 amp @ 86° F0.47"GrayPVC
    Black, Red, White-40 to 140UL Listed
    10, 25, 50, 100, 2507128K1300000000
    8
    38/3
    40 amp @ 86° F0.63"GrayPVC
    Black, Red, White-40 to 140UL Listed
    10, 25, 50, 1007128K1500000000
     

    Vehicle Wire

    Originally designed to meet the quality standards of the auto industry, this wire withstands high temperatures, flames, and abrasion. You'll often hear it referred to as primary wire in trucks, trailers, forklifts, and other vehicles.
    GPT Stranded Wire
    Image of Product. Front orientation. Vehicle Wire. Vehicle Wire, GPT Cable.
    In protected environments, such as vehicle interiors, GPT wire is the best choice.
    SAE J1128—Unlike other low-voltage wires, this wire meets strict SAE performance requirements.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Outer Jacket
    Material
    Temp. Range,
    ° F
    Specs.
    Met
    Lg.,
    ft.
    Choose an Outer Jacket Color
    Each
    25V AC/60V DC
    20
    10/30
    9 amp @ 86° F0.09"PVC
    -10 to 175SAE J1128100Black, Blue, Green, Red, White, Yellow6659T64000000
    18
    16/30
    17 amp @ 86° F0.1"PVC
    -10 to 175SAE J112845Black, Blue, Green, Red, White, Yellow6659T580000
    18
    16/30
    17 amp @ 86° F0.1"PVC
    -10 to 175SAE J1128100Black, Blue, Green, Red, White, Yellow6659T5400000
    16
    19/29
    21 amp @ 86° F0.11"PVC
    -10 to 175SAE J112835Black, Blue, Green, Red, White, Yellow6659T480000
    16
    19/29
    21 amp @ 86° F0.11"PVC
    -10 to 175SAE J1128100Black, Blue, Green, Red, White, Yellow6659T4400000
    14
    19/27
    29 amp @ 86° F0.12"PVC
    -10 to 175SAE J112820Black, Blue, Green, Red, White, Yellow6659T380000
    14
    19/27
    29 amp @ 86° F0.12"PVC
    -10 to 175SAE J1128100Black, Blue, Green, Red, White, Yellow6659T3400000
    12
    19/25
    38 amp @ 86° F0.15"PVC
    -10 to 175SAE J112812Black, Blue, Green, Red, White, Yellow6659T280000
    12
    19/25
    38 amp @ 86° F0.15"PVC
    -10 to 175SAE J1128100Black, Blue, Green, Red, White, Yellow6659T2400000
    10
    19/23
    51 amp @ 86° F0.18"PVC
    -10 to 175SAE J11288Black, Blue, Green, Red, White, Yellow6659T180000
    10
    19/23
    51 amp @ 86° F0.18"PVC
    -10 to 175SAE J1128100Black, Blue, Green, Red, White, Yellow6659T1400000
    8
    19/21
    51 amp @ 86° F0.22"PVC
    -10 to 175SAE J11288Black, Red6659T60000
    8
    19/21
    51 amp @ 86° F0.22"PVC
    -10 to 175SAE J1128100Black, Red6659T800000
     
    GXL Stranded Wire
    Image of Product. Front orientation. Vehicle Wire. Vehicle Wire, GXL Cable.
    For wiring exposed to weather and wear and tear, GXL wire is the standard choice, as it balances flexibility and abrasion-resistance.
    Cross-Linked Polyethylene Outer Jacket—For wiring exposed to weather and wear and tear, choose a wire with a cross-linked polyethylene outer jacket.
    SAE J1128—Unlike other low-voltage wires, this wire meets strict SAE performance requirements.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Outer Jacket Material
    Temp. Range,
    ° F
    Specs.
    Met
    Lg.,
    ft.
    Choose an Outer Jacket Color
    Each
    25V AC/60V DC
    20
    7/28
    5 amp @ 86° F0.09"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Blue, Green, Red, White5980N100000
    20
    7/28
    5 amp @ 86° F0.09"Cross-Linked Polyethylene-40 to 255SAE J112850Black, Blue, Green, Red, White5980N200000
    20
    7/28
    5 amp @ 86° F0.09"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Blue, Green, Red, White5980N300000
    20
    7/28
    5 amp @ 86° F0.09"Cross-Linked Polyethylene-40 to 255SAE J1128250Black, Red, White5980N400000
    20
    7/28
    5 amp @ 86° F0.09"Cross-Linked Polyethylene-40 to 255SAE J1128500Black, Red, White5980N500000
    18
    16/30
    5 amp @ 86° F0.09"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Blue, Green, Red, White5980N60000
    18
    16/30
    5 amp @ 86° F0.09"Cross-Linked Polyethylene-40 to 255SAE J112850Black, Blue, Green, Red, White5980N700000
    18
    16/30
    5 amp @ 86° F0.09"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Blue, Green, Red, White5980N800000
    18
    16/30
    5 amp @ 86° F0.09"Cross-Linked Polyethylene-40 to 255SAE J1128250Black, Red, White5980N900000
    18
    16/30
    5 amp @ 86° F0.09"Cross-Linked Polyethylene-40 to 255SAE J1128500Black, Red, White5980N21100000
    16
    19/29
    8 amp @ 86° F0.11"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Blue, Green, Red, White5980N2120000
    16
    19/29
    8 amp @ 86° F0.11"Cross-Linked Polyethylene-40 to 255SAE J112850Black, Blue, Green, Red, White5980N21300000
    16
    19/29
    8 amp @ 86° F0.11"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Blue, Green, Red, White5980N21400000
    16
    19/29
    8 amp @ 86° F0.11"Cross-Linked Polyethylene-40 to 255SAE J1128250Black, Red, White5980N21500000
    16
    19/29
    8 amp @ 86° F0.11"Cross-Linked Polyethylene-40 to 255SAE J1128500Black, Red, White5980N216000000
    14
    19/27
    11 amp @ 86° F0.12"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Blue, Green, Red, White5980N21700000
    14
    19/27
    11 amp @ 86° F0.12"Cross-Linked Polyethylene-40 to 255SAE J112850Black, Blue, Green, Red, White5980N21800000
    14
    19/27
    11 amp @ 86° F0.12"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Blue, Green, Red, White5980N21900000
    14
    19/27
    11 amp @ 86° F0.12"Cross-Linked Polyethylene-40 to 255SAE J1128250Black, Red, White5980N31100000
    14
    19/27
    11 amp @ 86° F0.12"Cross-Linked Polyethylene-40 to 255SAE J1128500Black, Red, White5980N312000000
    12
    19/25
    14 amp @ 86° F0.15"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Blue, Green, Red, White5980N31300000
    12
    19/25
    14 amp @ 86° F0.15"Cross-Linked Polyethylene-40 to 255SAE J112850Black, Blue, Green, Red, White5980N31400000
    12
    19/25
    14 amp @ 86° F0.15"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Blue, Green, Red, White5980N31500000
    12
    19/25
    14 amp @ 86° F0.15"Cross-Linked Polyethylene-40 to 255SAE J1128250Black, Red, White5980N316000000
    12
    19/25
    14 amp @ 86° F0.15"Cross-Linked Polyethylene-40 to 255SAE J1128500Black, Red, White5980N317000000
    10
    19/23
    23 amp @ 86° F0.18"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Blue, Green, Red, White5980N31800000
    10
    19/23
    23 amp @ 86° F0.18"Cross-Linked Polyethylene-40 to 255SAE J112850Black, Blue, Green, Red, White5980N31900000
    10
    19/23
    23 amp @ 86° F0.18"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Blue, Green, Red, White5980N32100000
    10
    19/23
    23 amp @ 86° F0.18"Cross-Linked Polyethylene-40 to 255SAE J1128250Black, Red, White5980N322000000
    10
    19/23
    23 amp @ 86° F0.18"Cross-Linked Polyethylene-40 to 255SAE J1128500Black, Red, White5980N323000000
     
    TXL Stranded Wire
    Image of Product. Front orientation. Vehicle Wire. Vehicle Wire, TXL Cable.
    For wiring exposed to weather and wear and tear, TXL wire has a thinner insulation, making it easy to maneuver in tight spaces.
    Cross-Linked Polyethylene Outer Jacket—For wiring exposed to weather and wear and tear, choose a wire with a cross-linked polyethylene outer jacket.
    SAE J1128—Unlike other low-voltage wires, this wire meets strict SAE performance requirements.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Outer Jacket Material
    Temp. Range,
    ° F
    Specs.
    Met
    Lg.,
    ft.
    Choose an Outer Jacket Color
    Each
    25V AC/60V DC
    22
    7/30
    3 amp @ 86° F0.06"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Blue, Green, Red, White5979N100000
    22
    7/30
    3 amp @ 86° F0.06"Cross-Linked Polyethylene-40 to 255SAE J112850Black, Blue, Green, Red, White5979N20000
    22
    7/30
    3 amp @ 86° F0.06"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Blue, Green, Red, White5979N300000
    22
    7/30
    3 amp @ 86° F0.06"Cross-Linked Polyethylene-40 to 255SAE J1128250Black, Red, White5979N400000
    22
    7/30
    3 amp @ 86° F0.06"Cross-Linked Polyethylene-40 to 255SAE J1128500Black, Red, White5979N500000
    20
    7/28
    5 amp @ 86° F0.07"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Blue, Green, Red, White5979N60000
    20
    7/28
    5 amp @ 86° F0.07"Cross-Linked Polyethylene-40 to 255SAE J112850Black, Blue, Green, Red, White5979N70000
    20
    7/28
    5 amp @ 86° F0.07"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Blue, Green, Red, White5979N800000
    20
    7/28
    5 amp @ 86° F0.07"Cross-Linked Polyethylene-40 to 255SAE J1128250Black, Red, White5979N900000
    20
    7/28
    5 amp @ 86° F0.07"Cross-Linked Polyethylene-40 to 255SAE J1128500Black, Red, White5979N21100000
    18
    16/30
    7 amp @ 86° F0.08"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Blue, Green, Red, White5979N2120000
    18
    16/30
    7 amp @ 86° F0.08"Cross-Linked Polyethylene-40 to 255SAE J112850Black, Blue, Green, Red, White5979N2130000
    18
    16/30
    7 amp @ 86° F0.08"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Blue, Green, Red, White5979N21400000
    18
    16/30
    7 amp @ 86° F0.08"Cross-Linked Polyethylene-40 to 255SAE J1128250Black, Red, White5979N21500000
    18
    16/30
    7 amp @ 86° F0.08"Cross-Linked Polyethylene-40 to 255SAE J1128500Black, Red, White5979N21600000
    16
    19/29
    10 amp @ 86° F0.09"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Blue, Green, Red, White5979N2170000
    16
    19/29
    10 amp @ 86° F0.09"Cross-Linked Polyethylene-40 to 255SAE J112850Black, Blue, Green, Red, White5979N21800000
    16
    19/29
    10 amp @ 86° F0.09"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Blue, Green, Red, White5979N21900000
    16
    19/29
    10 amp @ 86° F0.09"Cross-Linked Polyethylene-40 to 255SAE J1128250Black, Red, White5979N31100000
    16
    19/29
    10 amp @ 86° F0.09"Cross-Linked Polyethylene-40 to 255SAE J1128500Black, Red, White5979N312000000
    14
    19/27
    15 amp @ 86° F0.1"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Blue, Green, Red, White5979N31300000
    14
    19/27
    15 amp @ 86° F0.1"Cross-Linked Polyethylene-40 to 255SAE J112850Black, Blue, Green, Red, White5979N31400000
    14
    19/27
    15 amp @ 86° F0.1"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Blue, Green, Red, White5979N31500000
    14
    19/27
    15 amp @ 86° F0.1"Cross-Linked Polyethylene-40 to 255SAE J1128250Black, Red, White5979N31600000
    14
    19/27
    15 amp @ 86° F0.1"Cross-Linked Polyethylene-40 to 255SAE J1128500Black, Red, White5979N317000000
    12
    19/25
    20 amp @ 86° F0.13"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Blue, Green, Red, White5979N31800000
    12
    19/25
    20 amp @ 86° F0.13"Cross-Linked Polyethylene-40 to 255SAE J112850Black, Blue, Green, Red, White5979N31900000
    12
    19/25
    20 amp @ 86° F0.13"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Blue, Green, Red, White5979N41100000
    12
    19/25
    20 amp @ 86° F0.13"Cross-Linked Polyethylene-40 to 255SAE J1128250Black, Red, White5979N412000000
    12
    19/25
    20 amp @ 86° F0.13"Cross-Linked Polyethylene-40 to 255SAE J1128500Black, Red, White5979N413000000
     
    SXL Stranded Wire
    Image of Product. Front orientation. Vehicle Wire. Vehicle Wire, SXL Cable.
    For wiring exposed to weather and wear and tear, SXL wire has a thicker insulation and is the most durable. It can withstand repeated exposure to heat, dust, chemicals, and salt.
    Cross-Linked Polyethylene Outer Jacket—For wiring exposed to weather and wear and tear, choose a wire with a cross-linked polyethylene outer jacket.
    SAE J1128—Unlike other low-voltage wires, this wire meets strict SAE performance requirements.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Outer Jacket Material
    Temp. Range,
    ° F
    Specs.
    Met
    Lg.,
    ft.
    Choose an Outer
    Jacket Color
    Each
    25V AC/60V DC
    18
    16/30
    20 amp @ 86° F0.11"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Red6232N1100000
    18
    16/30
    20 amp @ 86° F0.11"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Red6232N2100000
    16
    19/29
    26 amp @ 86° F0.12"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Red6232N120000
    16
    19/29
    26 amp @ 86° F0.12"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Red6232N2200000
    14
    19/27
    40 amp @ 86° F0.14"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Red6232N1300000
    14
    19/27
    40 amp @ 86° F0.14"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Red6232N2300000
    12
    19/25
    50 amp @ 86° F0.16"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Red6232N1400000
    12
    19/25
    50 amp @ 86° F0.16"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Red6232N2400000
    10
    19/23
    70 amp @ 86° F0.19"Cross-Linked Polyethylene-40 to 255SAE J112825Black, Red6232N1500000
    10
    19/23
    70 amp @ 86° F0.19"Cross-Linked Polyethylene-40 to 255SAE J1128100Black, Red6232N2500000
     

    Moisture-Resistant Control Cable

    Image of Product. Front orientation. Control Cable. Moisture-Resistant Control Cable.
    Safely wire control circuits in wet locations such as washdown areas. A water-blocking fiber tape under the jacket of this cable prevents swelling and protects your connection. Use this cable to control, monitor, and regulate stationary equipment such as sensors and PLCs. You can flex and bend this cable during installation and adjustments, but it isn't made for continuous motion.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Cable
    Designation
    Temp.,
    ° F
    Certification
    Choose a Length, ft.
    1-249
    250-Up
    300V AC
     
    Unshielded
    18/2
    5 amp @ 86° FPVC with Fiber TapeBlackCL30 to 220UL Listed
    10, 25, 50, 100, 2507000T320000000000
    18/4
    7.2 amp @ 86° FPVC with Fiber TapeBlackCMG
    0 to 220UL Listed
    10, 25, 50, 100, 2507000T3300000000
    16/4
    9 amp @ 86° FPVC with Fiber TapeBlackCMG
    0 to 220UL Listed
    10, 25, 50, 100, 2507000T3400000000
    14/2
    8 amp @ 86° FPVC with Fiber TapeBlackCL30 to 220UL Listed
    10, 25, 50, 100, 2507000T3500000000
    14/4
    13 amp @ 86° FPVC with Fiber TapeBlackCL30 to 220UL Listed
    10, 25, 50, 100, 2507000T3600000000
    12/2
    12 amp @ 86° FPVC with Fiber TapeBlackCL30 to 220UL Listed
    10, 25, 50, 100, 2507000T3700000000
     

    Irrigation Cable

    Image of Product. Front orientation. Irrigation Cable.
    This wire is often used for sprinkler systems.
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Outer Jacket
    Color
    Inner Insulation
    Material
    Inner Insulation Color
    Temp. Range,
    ° F
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    500 ft.
    Long
    Solid Wire with Polyethylene Outer Jacket
     
    30V AC/30V DC
    18
    218/2
    0.2"BlackPolypropylene
    Red, White0 to 140UL Listed
    8070T11000000000000000000000000000000000000
    18
    318/3
    0.21"BlackPolypropylene
    Green, Red, White0 to 140UL Listed
    8070T1200000000000000000000000000000000
    18
    418/4
    0.23"BlackPolypropylene
    Blue, Green, Red, White0 to 140UL Listed
    8070T1300000000000000000000000000000000
    18
    518/5
    0.25"BlackPolypropylene
    Blue, Green, Red, White, Yellow0 to 140UL Listed
    8070T1400000000000000000000000000000000
    18
    618/6
    0.27"BlackPolypropylene
    Blue, Brown, Green, Red, White, Yellow0 to 140UL Listed
    8070T1500000000000000000000000000000000
    18
    718/7
    0.27"BlackPolypropylene
    Blue, Brown, Green, Orange, Red, White, Yellow0 to 140UL Listed
    8070T1600000000000000000000000000000000
    18
    818/8
    0.29"BlackPolypropylene
    Black, Blue, Brown, Green, Orange, Red, White, Yellow0 to 140UL Listed
    8070T17000000000000000000000000000000000
    18
    918/9
    0.31"BlackPolypropylene
    Black, Blue, Brown, Green, Orange, Pink, Red, White, Yellow0 to 140UL Listed
    8070T18000000000000000000000000000000000
     

    Fusible Link Wire

    Image of Product. Side1 orientation. Vehicle Wire. Fusible Link Wire.
    Often found in older vehicles, this fusible link wire protects a circuit in applications where you can’t use a standard fuse. The conductor in the fusible link melts if there’s a short circuit or voltage spike, breaking the circuit to protect the rest of your wiring. Since the conductor needs to be thin enough to melt before the rest of your wiring overheats, choose a fusible link wire that’s four gauge sizes smaller than your circuit. If you’re replacing a fusible link that has burned out, make sure the new wire is the same length and gauge as the old one.
    Cross-Linked Polyethylene Outer Jacket—Made of cross-linked polyethylene, the jacket withstands high temperatures and contains any sparks or flames caused by current overload.
    AWG
    Wire Strand
    Count
    OD
    Max. Temp.,
    ° F
    Specs.
    Met
    Outer Jacket
    Color
    Lg.,
    ft.
    Each
    Stranded Wire with Cross-Linked Polyethylene Outer Jacket
     
    12V DC
    18
    19/23
    0.02"300SAE J1128Blue86316N14500000
    18
    19/23
    0.02"300SAE J1128Blue1006316N24800000
    16
    19/30
    0.04"300SAE J1128Black76316N1540000
    16
    19/30
    0.04"300SAE J1128Black1006316N25800000
    14
    19/280.08"300SAE J1128Gray66316N1630000
    14
    19/280.08"300SAE J1128Gray1006316N26800000
    12
    19/25
    0.12"300SAE J1128Blue46316N1720000
    12
    19/25
    0.12"300SAE J1128Blue1006316N278000000
    10
    16/180.2"300SAE J1128Red16316N1810000
    10
    16/180.2"300SAE J1128Red756316N287000000
     
    back to top