McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    46 Products

    Breather Vents

    Image of Product. Style A. Front orientation. Style A. Breather Vents.
    Image of Product. Style H. Front orientation. Style H. Breather Vents.

    Style A

    Style H

    Protect against excess vacuum and pressure in cylinders, gear boxes, enclosures, manifolds, and tanks. You can also use these breather vents to block debris from entering equipment.
    Style H—Style H has a Buna-N O-ring for extra protection against leaks.
    Style
    Pipe
    Size
    Thread
    Size
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Max. Temp.,
    ° F
    Ht.
    For Use With
    Removes Particle
    Size Down To, μm
    Each
    NPT Male
     
    Zinc-Plated Steel Body and Fitting
    A2
    1,095 scfm @ 100 psi1503001 5/8"Air, Inert Gas900000000000000
     
    Nickel-Plated Steel Body and Fitting
    A1/8
    2 scfm @ 100 psi1503007/16"Air, Inert Gas4000000000000
    A1/4
    3 scfm @ 100 psi1503005/8"Air, Inert Gas4000000000000
    A3/8
    7 scfm @ 100 psi1503003/4"Air, Inert Gas4000000000000
    A1/2
    17 scfm @ 100 psi1503007/8"Air, Inert Gas4000000000000
    A3/4
    20 scfm @ 100 psi1503001"Air, Inert Gas4000000000000
    A1
    28 scfm @ 100 psi1503001 5/16"Air, Inert Gas4000000000000
    A1 1/4
    50 scfm @ 100 psi1503001 7/16"Air, Inert Gas40000000000000
    A1 1/2
    73 scfm @ 100 psi1503001 1/2"Air, Inert Gas40000000000000
     
    Brass Body and Fitting
    A1/16
    13 scfm @ 100 psi1503001/2"Air, Inert Gas9000000000000
     
    UNF Male
     
    Brass Body and Fitting
    A10-32
    6 scfm @ 100 psi1503003/8"Air, Inert Gas9000000000000
    H10-32
    1 scfm @ 100 psi1252007/16"Air, Inert Gas4000000000000
     
    BSPT Male
     
    Zinc-Plated Steel Body and Fitting
    A1/8
    26 scfm @ 100 psi1503007/16"Air, Inert Gas9000000000000
    A1/4
    35 scfm @ 100 psi15030011/16"Air, Inert Gas9000000000000
    A3/8
    87 scfm @ 100 psi15030013/16"Air, Inert Gas9000000000000
    A1/2
    131 scfm @ 100 psi1503001"Air, Inert Gas9000000000000
    A3/4
    219 scfm @ 100 psi1503001 1/16"Air, Inert Gas9000000000000
     
    NPSM Female
     
    Zinc-Plated Steel Body and Fitting
    F1/8
    26 scfm @ 100 psi1503005/8"Air, Inert Gas9000000000000
    F1/4
    35 scfm @ 100 psi1503003/4"Air, Inert Gas9000000000000
    F3/8
    87 scfm @ 100 psi15030015/16"Air, Inert Gas9000000000000
    F1/2
    131 scfm @ 100 psi1503001"Air, Inert Gas9000000000000
     

    Self-Draining Breather Vents

    Minimize moisture buildup in enclosures. Also known as drain plugs, these breather vents have a small outlet that allows condensation to drain. They have a silicone O-ring above the threads for a tight seal. Install them at the lowest point of the enclosure. Breather vents meet IP66 for protection in washdown environments. Use them to prevent excess vacuum and pressure in cylinders, gear boxes, and tanks and to block debris from entering equipment.
    Threaded NPT Male
    Image of Product. Bottom orientation. Breather Vents. Self-Draining Breather Vents.
    316 Stainless Steel Body and Fitting—316 stainless steel breather vents have excellent corrosion resistance.
    Brass Body and Fitting—Brass breather vents have good corrosion resistance.
    Pipe
    Size
    Max. Flow Rate
    @ Pressure
    Max.
    Pressure
    Max. Temp.,
    ° F
    Ht.
    Dia.
    For Use
    With
    Environment
    Hazardous Location Protection Type
    Enclosure
    Rating
    Hazardous Location Rating
    O-Ring
    Material
    Certification
    Features
    Each
    316 Stainless Steel Body and Fitting
    1/4
    Not RatedNot Rated3201 1/16"11/16"AirCorrosive, Dusty, Outdoor, Washdown, WetIP66, NEMA 4X
    Silicone Rubber
    Drain0000000000000
    1/2
    Not RatedNot Rated3201 1/8"1"AirCorrosive, Dusty, Hazardous, Outdoor, Washdown, WetIncreased Safety, Protection by EnclosureIP66, NEMA 4X
    ATEX I M2 Ex E I Mb; ATEX II 2 GD Ex E IIC Gb Ex Tb IIIC Db; IEC Zone 1 Groups IIC, IIB, IIA; IEC Zone 21 Groups IIIC, IIIB, IIIA; IECEx Ex E I/IIC Mb/Gb; IECEx Ex IIIC Tb DbSilicone Rubber
    CE Marked
    Drain000000000000
     
    Brass Body and Fitting
    1/4
    Not RatedNot Rated3201 1/16"11/16"AirCorrosive, Dusty, Outdoor, Washdown, WetIP66, NEMA 4X
    Silicone Rubber
    Drain000000000000
    1/2
    Not RatedNot Rated3201 1/8"1"AirCorrosive, Dusty, Hazardous, Outdoor, Washdown, WetIncreased Safety, Protection by EnclosureIP66, NEMA 4X
    ATEX I M2 Ex E I Mb; ATEX II 2 GD Ex E IIC Gb Ex Tb IIIC Db; IEC Zone 1 Groups IIC, IIB, IIA; IEC Zone 21 Groups IIIC, IIIB, IIIA; IECEx Ex E I/IIC Mb/Gb; IECEx Ex IIIC Tb DbSilicone Rubber
    CE Marked
    Drain000000000000
     

    Submersible Threaded Breather Vents

    Use these vents to maintain consistent pressure as temperatures fluctuate by allowing air to flow through sealed enclosures. All have a hydrophobic and oleophobic filter membrane that blocks moisture and contamination from particle buildup.
    Metric
    Image of Product. Front orientation. Breather Vents. Submersible Threaded Breather Vents, Metric, Nickel-Plated Brass.

    Nickel-Plated

    Brass

    Nickel-Plated Brass—Nickel-plated brass vents stand up to corrosive environments better than nylon and polycarbonate vents. They’re also durable, which means you won’t have to replace them as often.
    Thread
    Size
    Thread
    Pitch, mm
    For Hole
    Dia.
    Head
    Dia.
    Environment
    Enclosure
    Rating
    Features
    Each
     
    Nickel-Plated Brass
    M12
    1.51/2"3/4"Dusty, Submersible, Washdown, WetIP66, IP68
    Gasket0000000000000
    M16
    1.55/8"3/4"Dusty, Submersible, Washdown, WetIP66, IP68
    Gasket000000000000
    M20
    1.513/16"15/16"Dusty, Submersible, Washdown, WetIP66, IP68
    Gasket000000000000
     

    Hazardous-Location Electrical Enclosure Drain Vents

    Image of Product. Front orientation. Electrical Enclosure Drain Vents. Hazardous-Location Electrical Enclosure Drain Vents, Glass-Filled Nylon.

    Glass-Filled Nylon

    Safe for use around hazardous gasses and dust, these drain vents maintain steady pressure and prevent moisture buildup from temperature changes inside enclosures. They allow air to flow through the enclosures while protecting the contents from washdowns, dirt, and weather. Install these drain vents at the lowest point on an enclosure, so moisture can drip out.
    Increased Safety—Increased-safety drain vents keep sparks, high temperatures, or current creepage inside an enclosure, so they won’t ignite flammable gasses and dust.
    Glass-Filled Nylon—Glass-filled nylon drain vents are lightweight yet durable. They’re good for most areas.
    Thread Size
    Ht.
    Enclosure
    Rating
    Nut
    Material
    O-Ring
    Material
    Color
    Max. Temp.,
    ° F
    Hazardous Location Rating
    Each
    Increased-Safety Drain Vents
     
    Glass-Filled Nylon
    M20 × 1.5 mm1 1/4"NEMA 4X, IP66
    BrassBuna-N
    Black185ATEX II 2DG
    IECEx Ex Tb IIIC Db
    IECEx Exe II Gb
    NEC Class I Division 2 Groups A, B, C, D
    0000000000000
     

    Air-Release Valves for Water and Coolant

    These valves are often used to remove air pockets in cooling and heating systems to maintain consistent flow and prevent water surges that can damage equipment. All have a vented relief port to exhaust discharge directly.
    NPT Female Inlet and Relief Vent
    Image of Product. Front orientation. Air Vent Valves. Air-Release Valves for Water and Coolant, Female Inlet.
    Inlet
    Pipe
    Size
    Location
    Relief Port
    Location
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Overall
    Ht.
    Each
    Brass Body—Vertical Mount
    1/8
    BottomTop7533 to 2404 3/8"000000000000
    1/4
    BottomTop15033 to 2404 3/8"00000000000
     
    NPT Female Inlet, NPT Female Outlet and Relief Vent
    Image of Product. Front orientation. Air Vent Valves. Air-Release Valves for Water and Coolant, Female Inlet, Female Outlet.
    Inlet
    Outlet
    Pipe
    Size
    Location
    Pipe
    Size
    Location
    Relief Port
    Location
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Overall
    Ht.
    Each
    Brass Body—Vertical Mount
    1/8
    Bottom1/8
    SideTop7533 to 2404 3/8"000000000000
     
    NPT Female/Male Inlet and Relief Vent
    Image of Product. Front orientation. Air Vent Valves. Air-Release Valves for Water and Coolant, Female, Male.
    Valves with female/male inlets have an inlet with both male and female threads, so they can be connected to both male and female adapters and equipment ports.
    Inlet
    Female
    Pipe Size
    Male Pipe
    Size
    Location
    Relief Port
    Location
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Overall
    Ht.
    Each
    Brass Body—Vertical Mount
    1/2
    3/4
    BottomTop15033 to 2404 3/4"000000000000
     
    NPT Male Inlet and Relief Vent
    Image of Product. Top orientation. Air Vent Valves. Air-Release Valves for Water and Coolant, Male Inlet.
    Inlet
    Pipe
    Size
    Location
    Relief Port
    Location
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Overall
    Ht.
    Each
    Brass Body—Vertical Mount
    1/8
    BottomTop5033 to 2402 5/8"0000000000000
    1/8
    BottomTop5033 to 2403 3/4"000000000000
    1/8
    BottomTop7533 to 2404 3/8"00000000000
    1/4
    BottomTop5033 to 2404"000000000000
    1/4
    BottomTop15033 to 2404 3/4"00000000000
    1/2
    BottomTop15033 to 2403 3/8"000000000000
    3/4
    BottomTop15033 to 2403 3/8"000000000000
    1
    BottomTop15033 to 2403 1/2"000000000000
     

    Air-Release Valves for Steam

    Image of Product. Top orientation. Air Vent Valves. Air-Release Valves for Steam.
    Our only air-release valves for steam, these seal shut when steam enters the valve to prevent system contents from escaping through the relief port. They are commonly used to eliminate air pockets in steam mains and risers. They exhaust discharge directly through the vented relief port.
    Inlet
    Max. Steam
    Pressure, psi
    Pipe
    Size
    Location
    Relief Port
    Location
    Max. Temp.,
    ° F
    Overall
    Ht.
    Each
    NPT Male Relief Vent
     
    Brass Body
    153/4
    BottomTop2503 1/2"0000000000000
     

    Inline Air-Release Valves for Water

    Image of Product. Front orientation. Air Vent Valves. Inline Air-Release Valves for Water.
    Eliminate air pockets without stopping flow—these valves have an internal wire brush that traps air bubbles and discharges them through the top relief port while allowing inline flow from the inlet to the outlet. They are often used to increase efficiency in heating and cooling systems. The vented relief port exhausts discharge directly. Valves have a durable bronze body for a long service life.
    Inlet
    Outlet
    Relief
    Port
    Pipe
    Size
    Location
    Pipe
    Size
    Location
    Type
    Location
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Overall
    Ht.
    End-to-End
    Lg.
    Each
    NPT Female Inlet, NPT Female Outlet and Relief Vent
     
    Bronze Body—Vertical Mount
    3/4
    Side3/4
    SideVentTop12540 to 2406 15/16"2 11/16"00000000000000
    1
    Side1
    SideVentTop12540 to 2406 1/2"3 1/8"0000000000000
     

    Key-Operated Air-Release Valves for Water

    Image of Product. Front orientation. Air Vent Valves. Key-Operated Air-Release Valves for Water.
    Turn the key to manually release air from radiators, heaters, and other hot water equipment. These valves have a vented relief port that exhausts discharge directly. Body is nickel-plated brass for good corrosion resistance.
    Valves
    Replacement Keys
    Inlet
    Relief
    Port
    Pipe
    Size
    Location
    Type
    Location
    Max. Pressure,
    psi
    Temp. Range,
    ° F
    Overall
    Ht.
    Each
    Each
    NPT Male Inlet and Relief Vent
     
    Nickel-Plated Brass Body—Any-Angle Mount
    1/8
    BottomVentSide15033 to 2001"0000000000000000000000000
     
    back to top