About Industry Designation for Cable Insulation
More
DIN-Rail Mount Branch Circuit Breakers

Mount these circuit breakers directly to DIN rail to protect equipment and wiring in an area of your facility from overloads and short circuits. They meet UL 489 requirements for branch circuit protection and are certified as current limiting, so they protect equipment by minimizing passing current during a short circuit. Because they are thermal-magnetic, these breakers trip two ways. They either trip when heat is generated slowly by consistent low-level overload current, or they trip quickly when the magnetic coil senses a high-current short circuit.
Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
C-trip circuit breakers are the most common. They’re best for applications such as lighting and control panels, where equipment startup causes a moderate spike in current. They won’t trip until a rush of current reaches 5 to 10 times their rated current.
Shunt trips receive a signal from equipment to trip your circuit breaker in situations other than overload or short circuit conditions. For example, use them with a smoke detector to shut off power to a system in the event of a fire.
Auxiliary contacts send a signal to other equipment when the circuit trips. They can activate a warning light, initiate a shutdown, or start a backup power source.
Distribution bars simplify wiring by powering multiple adjacent circuit breakers without needing separate wires for each one. This cuts down on assembly time and space.
Extension terminals raise the wire connection point above distribution bars for easy access to connect power to a set of circuit breakers.
Distribution bar terminal covers shield unused, live terminals on distribution bars to prevent injury and damage.
For technical drawings and 3-D models, click on a part number.



Current, A | Voltage | Frequency, Hz | Breakthrough Current | For DIN Rail Size, mm | Wire Connection Type | Ht. | Wd. | Dp. | Temp. Range, °F | Specifications Met | Each | |
C Trip Type | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 Pole—Toggle Style | ||||||||||||
13 | 277V AC/48V DC | 50/60 | 10,000 A @ 277 V AC 10,000 A @ 48 V DC | 35 | Screw-Clamp Terminals | 4.13" | 0.7" | 2.36" | -10° to 165° | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 00000000 | 000000 |
2 Pole—Toggle Style | ||||||||||||
13 | 277V AC/480YV AC/96V DC | 50/60 | 10,000 A @ 277 V AC 10,000 A @ 480 V AC 10,000 A @ 96 V DC | 35 | Screw-Clamp Terminals | 4.13" | 1.4" | 2.36" | -10° to 165° | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 00000000 | 000000 |
3 Pole—Toggle Style | ||||||||||||
13 | 277V AC/480YV AC | 50/60 | 10,000 A @ 277 V AC 10,000 A @ 480 V AC | 35 | Screw-Clamp Terminals | 4.13" | 2.09" | 2.36" | -10° to 165° | UL 489, CSA Certified, CE Marked, IEC 60947-2 | 00000000 | 000000 |

Voltage | Current, A | Frequency, Hz | For DIN Rail Size, mm | Wire Connection Type | Ht. | Wd. | Dp. | Temp. Range, °F | Specifications Met | Each | |
12-110V AC/12-60V DC | 63 | 50/60 | 35 | Screw-Clamp Terminals | 4.13" | 0.7" | 2.36" | 25° to 100° | UL 489, UL Listed, CSA Certified, CE Marked, IEC 60898 | 00000000 | 000000 |
110-415V AC/110-230V DC | 40 | 50/60 | 35 | Screw-Clamp Terminals | 4.13" | 0.7" | 2.36" | 25° to 100° | UL 489, UL Listed, CSA Certified, CE Marked, IEC 60898 | 00000000 | 00000 |

Voltage | Current, A | Frequency, Hz | Industry Designation | No. of Circuits Controlled | Switch Starting Position | For DIN Rail Size, mm | Wire Connection Type | Ht. | Wd. | Dp. | Temp. Range, °F | Specifications Met | Each | |
250V AC | 6 | 50/60 | DPST | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | 35 | Screw-Clamp Terminals | 3.78" | 0.35" | 2.36" | -10° to 165° F | UL 489, UL Listed, CSA Certified, CE Marked, IEC 60898 | 00000000 | 000000 |

Terminal | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For No. of Poles | No. of Terminals | Voltage | Current, A | Frequency, Hz | Ctr.-to-Ctr. | Wd. | Ht. | Wd. | Dp. | Temp. Range, °F | Specifications Met | Each | |
1 | 12 | 277V AC/480YV AC/96V DC | 80 | 50/60 | 0.7" | 0.2" | 1.28" | 8.06" | 0.61" | -10° to 165° | UL 489, UL Recognized Component, CE Marked, IEC 60898 | 00000000 | 000000 |
2 | 12 | 277V AC/480YV AC/96V DC | 80 | 50/60 | 0.7" | 0.2" | 1.28" | 8.06" | 0.61" | -10° to 165° | UL 489, UL Recognized Component, CE Marked, IEC 60898 | 00000000 | 00000 |
3 | 12 | 277V AC/480YV AC/96V DC | 80 | 50/60 | 0.7" | 0.2" | 1.28" | 8.06" | 0.61" | -10° to 165° | UL 489, UL Recognized Component, CE Marked, IEC 60898 | 00000000 | 00000 |

For No. of Poles | Voltage | Current, A | Frequency, Hz | Wire Connection Type | Ht. | Wd. | Dp. | Temp. Range, °F | Specifications Met | Each | |
1, 2, 3 | 480V AC/96V DC | 80 | 50/60 | Screw-Clamp Terminals | 2.82" | 0.64" | 1.23" | -10° to 165° | UL 489, UL Recognized Component, CE Marked, IEC 60898 | 0000000 | 000000 |

For No. of Terminals | Ht. | Wd. | Dp. | Material | Temp. Range, °F | Specifications Met | Each | |
3 | 0.94" | 1.9" | 0.63" | Plastic | -10° to 165° | UL 489, UL Recognized Component, CE Marked, IEC 60898 | 00000000 | 00000 |
Automatic-Wind Cord Reels
![]() With Three Outlets and Circuit Breaker | ![]() NEMA 5-15 Plug |
![]() NEMA 5-15 Socket |
A ratchet holds the extension cord on these reels in place at any length; a quick pull releases the cord and the spring-driven winding mechanism retracts it. An adjustable ball lock controls how much cord retracts into the reel.
Reels with a swivel eye hook mount to the ceiling, so you can keep your cord on hand but out of the way.
Reels with a circuit breaker trip if there’s too much current to prevent overload damage.
Extension Cord | Power Cord | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Lg., ft. | Wire Ga. | Industry Designation | Lg. | Wire Ga. | Housing Material | Current, A | Voltage | Protection Type | Lg. | Wd. | Ht. | Features | Specifications Met | Color | Each | |
Extension Cord with NEMA 5-15 Socket and Power Cord with NEMA 5-15 Plug | |||||||||||||||||
3 | 30 | 14 | SJTW | 18" | 14 | Steel | 13 | 120V AC | Circuit Breaker | 9 1/2" | 3" | 11 1/4" | Adjustable Ball Lock, Ratchet, Swivel Eye Hook | UL Listed | Black | 0000000 | 0000000 |
Impact-Resistant Automatic-Wind Cord Reels
![]() With Three Outlets | ![]() NEMA 5-15 Plug |
![]() NEMA 5-15 Socket |
Made of impact-resistant plastic, these reels are more durable than other automatic-wind cord reels. They have a ratchet to hold the extension cord in place at any length; a quick pull releases the cord and the spring-driven winding mechanism retracts it. A resettable circuit breaker prevents overload damage. Mount reels to a wall or ceiling with the quick-release mounting bracket. The included extension cord resists oil and water.
Extension Cord | Power Cord | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Lg., ft. | Wire Ga. | Industry Designation | Lg., ft. | Wire Ga. | Housing Material | Current, A | Voltage | Protection Type | Lg. | Wd. | Ht. | Features | Specifications Met | Color | Each | |
Extension Cord with NEMA 5-15 Socket and Power Cord with NEMA 5-15 Plug | |||||||||||||||||
3 | 50 | 14 | SJTOW | 3 | 14 | Plastic | 13 | 120V AC | Circuit Breaker | 11 1/2" | 4 1/2" | 15 1/4" | Carrying Handle, Quick-Release Mounting Bracket, Ratchet | UL Listed, C-UL Listed | Black | 0000000 | 0000000 |
Water-Resistant Automatic-Wind Cord Reels
![]() | ![]() NEMA 5-15 Plug |
![]() NEMA 5-15 Socket |
With external components that resist water, oil, and UV light, these cord reels make power accessible in wet and outdoor areas. They’re great for maintenance vehicles, outdoor conveyors, and for powering tools such as compressors and power washers. The housing is rated NEMA 3R for outdoor use. It’s also made of impact-resistant plastic, so it won’t dent, bend, or corrode like a steel housing. The extension cord has water- and oil-resistant insulation, and the plug has a watertight connector. Close the connector’s outlet cover to keep out water and dust when you’re not using it.
A ratchet holds the cord extended at any length. A tug on the cord winds it up automatically, so you don’t have to wind it yourself.
To prevent overload damage, these reels have a circuit breaker that trips if there’s too much current.
For technical drawings and 3-D models, click on a part number.
Extension Cord | Power Cord | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Lg., ft. | Wire Ga. | Industry Designation | Lg., ft. | Wire Ga. | Housing Material | Current, A | Voltage | Protection Type | Lg. | Wd. | Ht. | Features | Environmental Rating | Specifications Met | Each | |
Extension Cord with NEMA 5-15 Socket and Power Cord with NEMA 5-15 Plug | |||||||||||||||||
1 | 30 | 14 | SJTOOW | 5 | 14 | Plastic | 13 | 125V AC | Circuit Breaker | 11 3/8" | 4 1/8" | 10 3/4" | Adjustable Ball Lock, Mounting Bracket, Outlet Cover, Ratchet | NEMA 3R | UL 94 V-0 | 0000000 | 0000000 |