    57 Products

    Panel-Mount Equipment Circuit Breakers

    Mount these breakers, also known as supplemental protectors, through panels downstream from a branch circuit breaker to protect a single piece of equipment. These breakers can also be used as on/off switches. All are thermal, so they use the heat generated in overcurrent situations to trip the breaker.
    Push-Button Style—Screw-On Mount
    Image of Product. Front orientation. Circuit Breakers. Panel-Mount Equipment Circuit Breakers, Push Button Manual Reset.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    For Panel
    Cutout
    Mounting
    Holes
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Ht.
    Wd.
    Dp. Behind
    Panel
    No.
    of
    Dia.
    Mounting Fasteners
    Included
    Quick-Disconnect
    Tab Wd.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole
    560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T41000000
    1060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T4200000
    1560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T4300000
    2060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T4400000
     
    2 Poles
    560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T5100000
    1060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T5200000
    1560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T5300000
    2060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T5400000
     
    Circuit Breaker Covers
    Rocker-Switch Style—Snap-In Mount
    Image of Product. Front orientation. Circuit Breakers. Panel-Mount Equipment Circuit Breakers, Rocker Switch Manual Reset.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    For Panel
    Cutout
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Ht.
    Wd.
    Dp. Behind
    Panel
    Quick-Disconnect
    Tab Wd.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole
    560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T11000000
    1060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T1200000
    1560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T1300000
    2060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T1400000
     
    2 Poles
    560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T2100000
    1060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T2200000
    1560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T2300000
    2060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T2400000
     
    Circuit Breaker Covers
    Toggle-Switch Style—Screw-On Mount
    Image of Product. Front orientation. Circuit Breakers. Panel-Mount Equipment Circuit Breakers, Toggle Switch Manual Reset.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    For Panel
    Cutout Dia.
    Dp. Behind
    Panel
    Mounting Fasteners
    Included
    Quick-Disconnect
    Tab Wd.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole
    1/2075V DC
    250V AC
    50/60200 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T11000000
    2/1075V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1200000
    4/1075V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1300000
    1/275V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1400000
    6/1075V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1500000
    8/1075V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1600000
    175V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1700000
    1 1/275V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1800000
    275V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1900000
    2 1/275V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2100000
    375V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2200000
    475V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2300000
    575V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2400000
    675V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2500000
    875V DC
    250V AC
    50/602,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2600000
    1075V DC
    250V AC
    50/602,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2700000
     

    High-Temperature Panel-Mount Circuit Breakers

    Image of Product. Front orientation. Circuit Breakers. High-Temperature Panel-Mount Circuit Breakers , 1 Pole—Toggle-Switch Style.
    Image of Product. Front orientation. Circuit Breakers. High-Temperature Panel-Mount Circuit Breakers , 2 Poles—Toggle-Switch Style.

    1

    Pole—Toggle-Switch

    Style

    2

    Poles—Toggle-Switch

    Style

    Unlike breakers that trip thermally, these breakers have a hydraulic-magnetic trip mechanism, so they aren’t affected by changes in temperature. Instead, these circuit breakers trip when they hydraulically sense consistent low-level overload current, or they trip quickly when the magnetic coil senses a high-current short circuit. Use the threaded holes on the face to install them through panels, enclosure covers, or walls to keep them close to the equipment they protect.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    For Panel
    Cutout
    Mounting
    Holes
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Temp. Range,
    ° F
    Ht.
    Wd.
    Dia.
    Dp. Behind
    Panel
    No.
    of
    Thread
    Size
    Mounting Fasteners
    Included
    Wire Connection
    Ht.
    Wd.
    Each
    1 Pole—Toggle-Switch Style
    580V DC
    277V AC
    50/605,000 amp @ 277V AC
    7,500 amp @ 80V DC
    -40 to 1850.63"2"26-32
    NoQuick-Disconnect Terminal2"0.75"72015K111000000
    1080V DC
    277V AC
    50/605,000 amp @ 277V AC
    7,500 amp @ 80V DC
    -40 to 1850.63"2"26-32
    NoQuick-Disconnect Terminal2"0.75"72015K11200000
    1580V DC
    277V AC
    50/605,000 amp @ 277V AC
    7,500 amp @ 80V DC
    -40 to 1850.63"2"26-32
    NoQuick-Disconnect Terminal2"0.75"72015K11300000
    2080V DC
    277V AC
    50/605,000 amp @ 277V AC
    7,500 amp @ 80V DC
    -40 to 1850.63"2"26-32
    NoQuick-Disconnect Terminal2"0.75"72015K11400000
    3080V DC
    277V AC
    50/605,000 amp @ 277V AC
    7,500 amp @ 80V DC
    -40 to 1850.63"2"26-32
    NoQuick-Disconnect Terminal2"0.75"72015K11500000
    4080V DC
    250V AC
    50/601,500 amp @ 250V AC
    5,000 amp @ 80V DC
    -40 to 1851.45"0.76"2.573"26-32
    NoScrew Terminal2.5"0.75"72015K3600000
    50 80V DC
    250V AC
    50/601,500 amp @ 250V AC
    5,000 amp @ 80V DC
    -40 to 1851.45"0.76"2.573"26-32
    NoScrew Terminal2.5"0.75"72015K3500000
     
    2 Poles—Toggle-Switch Style
    580V DC
    277V AC
    50/605,000 amp @ 277V AC
    7,500 amp @ 80V DC
    -40 to 1850.63"2"46-32
    NoQuick-Disconnect Terminal2"1.5"72015K5100000
    1080V DC
    277V AC
    50/605,000 amp @ 277V AC
    7,500 amp @ 80V DC
    -40 to 1850.63"2"46-32
    NoQuick-Disconnect Terminal2"1.5"72015K5200000
    15250V AC50/601,500 amp @ 250V AC-40 to 1851.45"1.52"2.573"46-32
    NoScrew Terminal2.5"1.5"72015K41000000
    20250V AC50/601,500 amp @ 250V AC-40 to 1851.45"1.52"2.573"46-32
    NoScrew Terminal2.5"1.5"72015K42000000
     

    Harsh-Environment Circuit Breakers

    Image of Product. Front orientation. Circuit Breakers. Harsh-Environment Circuit Breakers, 1 Pole—Push-Pull-Button Style.

    1

    Pole—Push-Pull-Button

    Style

    Built to resist vibration and corrosion in harsh environments, these circuit breakers protect against overload and short circuits in low-voltage automotive and other electronic applications. All are thermal, so they use the heat generated in overcurrent situations to trip the breaker.
    Push-Pull Button Manual Reset—Push-pull button and lever style breakers can be used as an on/off switch.
    UL 1077—Place UL 1077-rated breakers downstream from a branch circuit breaker to protect a single piece of equipment. They are also known as supplemental protectors.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Screw On
    Current,
    A
    Voltage,
    V DC
    Breakthrough Current
    @ Voltage
    For Panel
    Cutout Dia.
    Dp. Behind
    Panel
    Mounting
    Location
    Mounting Fasteners
    Included
    Wire
    Connection
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole—Push-Pull-Button Style
     
    Thermal
    30286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T11000000
    35286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1200000
    40286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1300000
    45286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1400000
    50 286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1500000
    55286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1600000
    60286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1700000
    70286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1800000
    80286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1900000
    90286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T2100000
     

    Space-Saving Panel-Mount Branch Circuit Breakers

    Image of Product. Front orientation. Circuit Breakers. Space-Saving Panel-Mount Branch Circuit Breakers.
    Small enough to fit in tight spaces, these circuit breakers mount through panels. They are thermal, so they use the heat generated in overcurrent situations to trip the breaker.
    UL 489—These circuit breakers are UL 489-rated for branch circuit protection.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Screw On
    Current,
    A
    Voltage,
    V AC
    Freq., Hz
    Breakthrough Current
    @ Voltage
    For Panel
    Cutout Dia.
    Dp. Behind
    Panel
    Mounting
    Location
    Mounting Fasteners
    Included
    Wire Connection
    Quick-Disconnect
    Tab Wd.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole—Push-Button Style
     
    Thermal
    1512050/605,000 amp @ 120V AC0.38"1.43"PanelYesQuick-Disconnect Terminal0.25"35 to 140UL 489UL Listed, CSA Certified
    3851K11000000
    2012050/605,000 amp @ 120V AC0.38"1.43"PanelYesQuick-Disconnect Terminal0.25"35 to 140UL 489UL Listed, CSA Certified
    3851K1200000
     
    back to top