    178 Products

    DIN-Rail Mount Equipment Circuit Breakers

    Image of ProductInUse. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers.
    Image of Product. Auxiliary Contact. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers.
    Image of Product. Distribution Bar. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers.
    Image of Product. Distribution Bar Terminal Cover. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers.

    Auxiliary

    Contact

    Distribution Bar

    Distribution Bar

    Terminal Cover

    Image of Product. Distribution Bar End Cover. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers.
    Image of Product. Shunt Trip. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers.
    Image of Product. Extension Terminal. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers.

    Distribution

    Bar End Cover

    Shunt

    Trip

    Extension

    Terminal

    Distribution bars simplify wiring by powering multiple adjacent circuit breakers without needing separate wires for each one. This cuts down on assembly time and space. Cut them to the number of terminals that you need.
    Distribution bar terminal covers shield unused, live terminals on distribution bars to prevent injury and damage.
    Auxiliary contacts send a signal to other equipment when the circuit trips. They can activate a warning light, initiate a shutdown, or start a backup power source.
    Shunt trips receive a signal from equipment to trip your circuit breaker in situations other than overload or short circuit conditions. For example, use them with a smoke detector to shut off power to a system in the event of a fire.
    Extension terminals raise the wire connection point above distribution bars for easy access to connect power to a set of circuit breakers.
    Also known as supplemental protectors, these circuit breakers mount directly to DIN rail downstream from a branch circuit breaker to protect a single piece of equipment. Because they are thermal-magnetic, these breakers trip two ways. They either trip when heat is generated slowly by consistent low-level overload current, or they trip quickly when the magnetic coil senses a high-current short circuit.
    Distribution bar end covers seal the live ends of distribution bars to prevent injury and damage.
    B Trip
    Image of Product. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers, 1 Pole—Toggle-Switch Style.

    1

    Pole—Toggle-Switch

    Style

    B-trip circuit breakers are best for protecting sensitive equipment, such as programmable logic controllers (PLCs) and sensors, which could be damaged by a spike in current. These circuit breakers will trip if a rush of current reaches 3 to 5 times their rated current.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    For DIN
    Rail Size, mm
    Mounting
    Location
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Specs. Met
    Certification
    Each
    1 Pole—Toggle-Switch Style
     
    Thermal/Magnetic
    148V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K679000000
    548V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K61100000
    1048V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K61200000
    1548V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K61300000
    2048V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K61400000
    3048V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K61500000
     
    Accessories for Circuit Breakers
    C Trip
    Image of Product. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers, 1 Pole—Toggle-Switch Style.

    1

    Pole—Toggle-Switch

    Style

    C-trip circuit breakers are the most common. They’re best for applications such as lighting and control panels, where equipment startup causes a moderate spike in current. They won’t trip until a rush of current reaches 5 to 10 times their rated current.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    For DIN
    Rail Size, mm
    Mounting
    Location
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Specs. Met
    Certification
    Each
    1 Pole—Toggle-Switch Style
     
    Thermal/Magnetic
    148V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K65000000
    248V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K6600000
    348V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K6700000
    448V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K6800000
    548V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K6100000
    648V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K62800000
    848V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K62900000
    1048V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K6200000
    1548V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K6300000
    2048V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K6400000
    2548V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K68200000
    3048V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K6900000
    4048V DC
    277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K63100000
    50 48V DC
    277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K63200000
     
    Accessories for Circuit Breakers
    D Trip
    Image of Product. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers, 1 Pole—Toggle-Switch Style.

    1

    Pole—Toggle-Switch

    Style

    D-trip circuit breakers prevent nuisance tripping, so they are best for equipment that has a high spike in current at startup, such as transformers, power supplies, and heaters. They will not trip unless a rush of current reaches 10 to 20 times their rated current.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    For DIN
    Rail Size, mm
    Mounting
    Location
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Specs. Met
    Certification
    Each
    1 Pole—Toggle-Switch Style
     
    Thermal/Magnetic
    148V DC
    277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K649000000
    248V DC
    277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K31100000
    348V DC
    277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K31200000
    448V DC
    277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K68400000
    548V DC
    277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K31300000
    648V DC
    277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K65100000
    848V DC
    277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K65200000
    1048V DC
    277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K31400000
    1548V DC
    277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K31500000
    2048V DC
    277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K31600000
    2548V DC
    277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K65300000
    3048V DC
    277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K65400000
    4048V DC
    277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K31700000
    50 48V DC
    277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal3.15"0.7"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K65500000
     
    Accessories for Circuit Breakers

    Square D Load-Center Circuit Breakers

    Match these circuit breakers to Square D breaker boxes or panel boards of the same manufacturer series. Because they are thermal-magnetic, these breakers trip two different ways. They either trip when heat is generated by sustained low-level overload current or quickly when the magnetic coil senses a high-current short circuit.
    QO Series
    Image of Product. QO Series, 1 Pole. Front orientation. Circuit Breakers. Square D Load-Center Circuit Breakers, QO Series, 1 Pole—Toggle-Switch Style.

    QO

    Series, 1

    Pole

    UL 489—They meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Mounting
    Location
    Wire Connection
    Method
    Wd.
    Specs.
    Met
    Certification
    Each
    1 Pole—Toggle-Switch Style
    1548V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Breaker BoxSnap On3/4"UL 489UL Listed
    6782K112000000
    2048V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Breaker BoxSnap On3/4"UL 489UL Listed
    6782K11300000
    30120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On3/4"UL 489UL Listed
    6782K1200000
    4048V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Breaker BoxSnap On3/4"UL 489UL Listed
    6782K30100000
     
    QO Series with 6 mA Ground Fault Sensitivity
    Image of Product. QO Series, 1 Pole. Front orientation. Circuit Breakers. Square D Load-Center Circuit Breakers, QO Series, 1 Pole—Toggle-Switch Style.

    QO

    Series, 1

    Pole

    Circuit breakers with ground fault sensitivity will trip if they detect a current leak above 6 mA. This minimizes the risk of electric shock to workers and equipment.
    UL 489—They meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage,
    V AC
    Freq., Hz
    Breakthrough Current
    @ Voltage
    Mounting
    Location
    Wire Connection
    Method
    Wd.
    Specs.
    Met
    Certification
    Each
    1 Pole—Toggle-Switch Style
    2012050/6010,000 amp @ 120V ACBreaker BoxSnap On3/4"UL 489UL Listed
    6782K3020000000
    3012050/6010,000 amp @ 120V ACBreaker BoxSnap On3/4"UL 489UL Listed
    6782K303000000
     
    QOB Series
    Image of Product. QOB Series, 1 Pole. Front orientation. Circuit Breakers. Square D Load-Center Circuit Breakers, QOB Series, 1 Pole—Toggle-Switch Style.

    QOB

    Series,

    1 Pole

    UL 489—They meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Mounting
    Location
    Wire Connection
    Wd.
    Specs.
    Met
    Certification
    Each
    1 Pole—Toggle-Switch Style
    1548V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Panel BoardScrew-Clamp Terminal3/4"UL 489UL Listed
    6782K511000000
    2048V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Panel BoardScrew-Clamp Terminal3/4"UL 489UL Listed
    6782K51200000
    3048V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Panel BoardScrew-Clamp Terminal3/4"UL 489UL Listed
    6782K51300000
    4048V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Panel BoardScrew-Clamp Terminal3/4"UL 489UL Listed
    6782K3100000
     
    Homeline Series
    Image of Product. Homeline Series, 1 Pole. Front orientation. Circuit Breakers. Square D Load-Center Circuit Breakers, Homeline Series, 1 Pole—Toggle-Switch Style.
    Image of Product. Homeline Series, 2 Poles. Front orientation. Circuit Breakers. Square D Load-Center Circuit Breakers, Homeline Series, 1 Pole with Tandem Circuit—Toggle Switch.

    Homeline

    Series, 1

    Pole

    Homeline

    Series, 2

    Poles

    UL 489—They meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage, V AC
    Freq., Hz
    Breakthrough Current @ Voltage
    Mounting
    Location
    Wire Connection
    Method
    Wd.
    Specs.
    Met
    Certification
    Each
    1 Pole—Toggle-Switch Style
    15120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On1"UL 489UL Listed
    69225K71000000
    20120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On1"UL 489UL Listed
    69225K7200000
    30120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On1"UL 489UL Listed
    69225K7300000
    40120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On1"UL 489UL Listed
    69225K9100000
    50 120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On1"UL 489UL Listed
    69225K10100000
     
    1 Pole with Tandem Circuit—Toggle Switch
    20120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On1"UL 489UL Listed
    69225K8400000
     
    Homeline Series with 6 mA Ground Fault Sensitivity
    Image of Product. Homeline Series, 1 Pole. Front orientation. Circuit Breakers. Square D Load-Center Circuit Breakers, Homeline Series, 1 Pole—Toggle-Switch Style.

    Homeline

    Series, 1

    Pole

    Circuit breakers with ground fault sensitivity will trip if they detect a current leak above 6 mA. This minimizes the risk of electric shock to workers and equipment.
    UL 489—They meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage,
    V AC
    Freq., Hz
    Breakthrough Current
    @ Voltage
    Mounting
    Location
    Wire Connection
    Method
    Wd.
    Specs.
    Met
    Certification
    Each
    1 Pole—Toggle-Switch Style
    2012050/6010,000 amp @ 120V ACBreaker BoxSnap On1"UL 489UL Listed
    69225K820000000
     

    DIN-Rail Mount Branch Circuit Breakers

    Image of ProductInUse. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers.
    Image of Product. Extension Terminal. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers.
    Image of Product. Distribution Bar Terminal Cover. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers.
    Image of Product. Shunt Trip. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers.

    Extension

    Terminal

    Distribution

    Bar Terminal

    Cover

    Shunt

    Trip

    Image of Product. Auxiliary Contact. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers.
    Image of Product. Distribution Bar. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers.

    Auxiliary

    Contact

    Distribution Bar

    Distribution bar terminal covers shield unused, live terminals on distribution bars to prevent injury and damage.
    Auxiliary contacts send a signal to other equipment when the circuit trips. They can activate a warning light, initiate a shutdown, or start a backup power source.
    Shunt trips receive a signal from equipment to trip your circuit breaker in situations other than overload or short circuit conditions. For example, use them with a smoke detector to shut off power to a system in the event of a fire.
    Extension terminals raise the wire connection point above distribution bars for easy access to connect power to a set of circuit breakers.
    Mount these circuit breakers directly to DIN rail to protect equipment and wiring in an area of your facility from overloads and short circuits. Because they are thermal-magnetic, these breakers trip two ways. They either trip when heat is generated slowly by consistent low-level overload current, or they trip quickly when the magnetic coil senses a high-current short circuit.
    Distribution bars simplify wiring by powering multiple adjacent circuit breakers without needing separate wires for each one. This cuts down on assembly time and space.
    B Trip
    Image of Product. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers, 1 Pole—Toggle-Switch Style.

    1

    Pole—Toggle-Switch

    Style

    B-trip circuit breakers are best for protecting sensitive equipment, such as programmable logic controllers (PLCs) and sensors, which could be damaged by a spike in current. These circuit breakers will trip if a rush of current reaches 3 to 5 times their rated current.
    UL 489—They meet UL 489 requirements for branch circuit protection and are certified as current limiting, so they protect equipment by minimizing passing current during a short circuit.
    Voltage
    Freq., Hz
    For DIN
    Rail Size, mm
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Specs. Met
    Certification
    Choose a Current, A
    Each
    1 Pole—Toggle-Switch Style
    48V DC
    277V AC
    50/6035Screw-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    1
    ,
    5
    ,
    10
    ,
    15
    ,
    20
    ,
    30
    5789T201000000
     
    Accessories for Circuit Breakers
    C Trip
    Image of Product. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers, 1 Pole—Toggle-Switch Style.

    1

    Pole—Toggle-Switch

    Style

    C-trip circuit breakers are the most common. They’re best for applications such as lighting and control panels, where equipment startup causes a moderate spike in current. They won’t trip until a rush of current reaches 5 to 10 times their rated current.
    UL 489—They meet UL 489 requirements for branch circuit protection and are certified as current limiting, so they protect equipment by minimizing passing current during a short circuit.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    For DIN
    Rail Size, mm
    Mounting
    Location
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Specs. Met
    Certification
    Choose a Current,
    A
    Each
    1 Pole—Toggle-Switch Style
     
    Thermal/Magnetic
    48V DC
    240V AC
    50/6010,000 amp @ 240V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    35
    ,
    40
    ,
    50
    ,
    63
    5789T204000000
    48V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    1/25789T10100000
    48V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    15789T10200000
    48V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    1 1/25789T10300000
    48V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    25789T10400000
    48V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    35789T10500000
    48V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    45789T10600000
    48V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    55789T7100000
    48V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    65789T10700000
    48V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    75789T10800000
    48V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    85789T10900000
    48V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    105789T7200000
    48V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    135789T11100000
    48V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    305789T7500000
    48V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    325789T11400000
    48V DC
    277V AC
    50/6014,000 amp @ 277V AC
    14,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    155789T7300000
    48V DC
    277V AC
    50/6014,000 amp @ 277V AC
    14,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    165789T11200000
    48V DC
    277V AC
    50/6014,000 amp @ 277V AC
    14,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    205789T7400000
    48V DC
    277V AC
    50/6014,000 amp @ 277V AC
    14,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    255789T11300000
     
    Accessories for Circuit Breakers
    D Trip
    Image of Product. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers, 1 Pole—Toggle-Switch Style.

    1

    Pole—Toggle-Switch

    Style

    D-trip circuit breakers prevent nuisance tripping, so they are best for equipment that has a high spike in current at startup, such as transformers, power supplies, and heaters. They will not trip unless a rush of current reaches 10 to 20 times their rated current.
    UL 489—They meet UL 489 requirements for branch circuit protection and are certified as current limiting, so they protect equipment by minimizing passing current during a short circuit.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    For DIN
    Rail Size, mm
    Mounting
    Location
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Specs. Met
    Certification
    Each
    1 Pole—Toggle-Switch Style
     
    Thermal/Magnetic
    148V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T438000000
    248V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T41100000
    348V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T41200000
    448V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T43900000
    548V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T41300000
    648V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T4400000
    848V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T44100000
    1048V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T41400000
    1548V DC
    277V AC
    50/6014,000 amp @ 277V AC
    14,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T41500000
    2048V DC
    277V AC
    50/6014,000 amp @ 277V AC
    14,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T41600000
    2548V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T44200000
    3048V DC
    277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T41700000
    4048V DC
    240V AC
    50/6010,000 amp @ 240V AC
    10,000 amp @ 48V DC
    35DIN RailScrew-Clamp Terminal4.13"0.7"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T44300000
     
    Accessories for Circuit Breakers

    Harsh-Environment Circuit Breakers

    Built to resist vibration and corrosion in harsh environments, these circuit breakers protect against overload and short circuits in low-voltage automotive and other electronic applications. All are thermal, so they use the heat generated in overcurrent situations to trip the breaker.
    Lever Manual Reset and Push-Pull Button Manual Reset—Push-pull button and lever style breakers can be used as an on/off switch.
    UL 1077—Place UL 1077-rated breakers downstream from a branch circuit breaker to protect a single piece of equipment. They are also known as supplemental protectors.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Mounting
    Holes
    Screw On
    Current,
    A
    Voltage,
    V DC
    Breakthrough Current
    @ Voltage
    For Panel
    Cutout Dia.
    Dp. Behind
    Panel
    Mounting
    Location
    No.
    of
    Dia.
    Mounting Fasteners
    Included
    Wire
    Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole—Push-Pull-Button Style
    Image of Product. Front orientation. Circuit Breakers. Harsh-Environment Circuit Breakers, 1 Pole—Push-Pull-Button Style.
     
    Thermal
    30286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T11000000
    35286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1200000
    40286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1300000
    45286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1400000
    50 286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1500000
    55286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1600000
    60286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1700000
    70286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1800000
    80286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T1900000
    90286,000 amp @ 28V DC0.49"2.48"PanelYesScrew Terminal-65 to 165UL 1077UL Recognized Component
    6608T2100000
     
    1 Pole—Lever Style
    Image of Product. Front orientation. Circuit Breakers. Harsh-Environment Circuit Breakers, 1 Pole—Lever Style.
     
    Thermal
    30481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22200000
    40481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22300000
    50 481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22400000
    60481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22500000
    70481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22600000
    80481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22700000
    100481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22800000
    120481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K22900000
    135481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K23100000
    150481,500 amp @ 48V DC30.19"NoScrew Terminal3.44"2.32"1.72"-40 to 185CE Marked
    4514K23200000
     
    1 Pole—Push-Button Style
    Image of Product. Front orientation. Circuit Breakers. Harsh-Environment Circuit Breakers, 1 Pole—Push-Button Style.
     
    Thermal
    30481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13100000
    40481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13200000
    50 481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13300000
    60481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13400000
    70481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13500000
    80481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13600000
    90481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13700000
    100481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13800000
    120481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K13900000
    135481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K14100000
    150481,500 amp @ 48V DC20.25"NoScrew Terminal2.89"1.9"1.44"-40 to 185CE Marked
    4514K14200000
     

    Panel-Mount Equipment Circuit Breakers

    Mount these breakers, also known as supplemental protectors, through panels downstream from a branch circuit breaker to protect a single piece of equipment. These breakers can also be used as on/off switches. All are thermal, so they use the heat generated in overcurrent situations to trip the breaker.
    Push-Button Style—Screw-On Mount
    Image of Product. Front orientation. Circuit Breakers. Panel-Mount Equipment Circuit Breakers, Push Button Manual Reset.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    For Panel
    Cutout
    Mounting
    Holes
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Ht.
    Wd.
    Dp. Behind
    Panel
    No.
    of
    Dia.
    Mounting Fasteners
    Included
    Quick-Disconnect
    Tab Wd.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole
    560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T41000000
    1060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T4200000
    1560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T4300000
    2060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T4400000
     
    Circuit Breaker Covers
    Rocker-Switch Style—Snap-In Mount
    Image of Product. Front orientation. Circuit Breakers. Panel-Mount Equipment Circuit Breakers, Rocker Switch Manual Reset.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    For Panel
    Cutout
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Ht.
    Wd.
    Dp. Behind
    Panel
    Quick-Disconnect
    Tab Wd.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole
    560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T11000000
    1060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T1200000
    1560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T1300000
    2060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T1400000
     
    Circuit Breaker Covers
    Toggle-Switch Style—Screw-On Mount
    Image of Product. Front orientation. Circuit Breakers. Panel-Mount Equipment Circuit Breakers, Toggle Switch Manual Reset.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    For Panel
    Cutout Dia.
    Dp. Behind
    Panel
    Mounting Fasteners
    Included
    Quick-Disconnect
    Tab Wd.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole
    1/2075V DC
    250V AC
    50/60200 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T11000000
    2/1075V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1200000
    4/1075V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1300000
    1/275V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1400000
    6/1075V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1500000
    8/1075V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1600000
    175V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1700000
    1 1/275V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1800000
    275V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T1900000
    2 1/275V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2100000
    375V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2200000
    475V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2300000
    575V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2400000
    675V DC
    250V AC
    50/601,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2500000
    875V DC
    250V AC
    50/602,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2600000
    1075V DC
    250V AC
    50/602,000 amp @ 250V AC
    800 amp @ 75V DC
    1/4"2.42"Yes0.25"-20 to 140UL 1077UL Recognized Component
    7588T2700000
     

    Siemens Load-Center Circuit Breakers

    Image of Product. Front orientation. Circuit Breakers. Siemens Load-Center Circuit Breakers, 1 Pole—Toggle-Switch Style.

    1

    Pole—Toggle-Switch

    Style

    Use with Siemens EQ series breaker boxes. Because they are thermal-magnetic, these circuit breakers trip two different ways. They either trip when heat is generated slowly by consistent low-level overload current or quickly when the magnetic coil senses a high-current short circuit.
    UL 489—These circuit breakers meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage, V AC
    Freq.,
    Hz
    Breakthrough Current @ Voltage
    Mounting
    Location
    Wire Connection
    Wd.
    Specs.
    Met
    Each
    1 Pole—Toggle-Switch Style
     
    Thermal/Magnetic
    15120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal1"UL 4895259T41000000
    20120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal1"UL 4895259T4200000
    30120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal1"UL 4895259T4300000
     

    DIN-Rail Mount Electronic Circuit Breakers

    An electronic trip mechanism makes these circuit breakers fast, precise, and consistent. They continuously monitor current and trip at a precise value compared to the much wider current range in traditional thermal-magnetic breakers. They're good for protecting devices that could be easily damaged by overcurrent such as sensors, HMIs, and controllers. Because they trip electronically, they don't require the bulky housing necessary for thermal trip mechanisms, so they take up less space in your control cabinet. They also eliminate the need for accessories, such as shunt trips, because they can be remotely monitored and controlled. For at the source troubleshooting, they have an indicator light and on/off/reset button for each circuit. To make sure your equipment is receiving the correct voltage, these breakers will also trip when the supply voltage goes under or over a set value.
    Fixed Current—Digital Input/Output
    Image of System. Front orientation. Contains MultipleImages. Circuit Breakers. DIN-Rail Mount Electronic Circuit Breakers, Push-Button Style, 1 Circuit Controlled.

    Push-Button Style,

    1 Circuit

    Controlled

    Fixed-current breakers come set to trip at a specific current. This prevents accidental or unauthorized changes to when they’ll trip.
    Breakers with digital input/outputs send and receive signals, so you can remotely check the status of your breaker, reset it, and turn it on and off.
    No. of Circuits
    Controlled
    Current,
    A
    Voltage,
    V DC
    No. of
    Inputs
    No. of
    Outputs
    For DIN
    Rail Size, mm
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    Push-Button Style
    11/2241135Spring-Clamp Terminal3.7"0.24"3.85"-10 to 145IP20
    3897N12000000
    11241135Spring-Clamp Terminal3.7"0.24"3.85"-10 to 145IP20
    3897N1300000
    12241135Spring-Clamp Terminal3.7"0.24"3.85"-10 to 145IP20
    3897N1400000
    14241135Spring-Clamp Terminal3.7"0.24"3.85"-10 to 145IP20
    3897N1500000
    16241135Spring-Clamp Terminal3.7"0.24"3.85"-10 to 145IP20
    3897N1600000
    18241135Spring-Clamp Terminal3.7"0.24"3.85"-10 to 145IP20
    3897N17000000
     
    Adjustable Current—Digital Input/Output
    Image of System. Front orientation. Contains MultipleImages. Circuit Breakers. DIN-Rail Mount Electronic Circuit Breakers, Push-Button Style, 1 Circuit Controlled.
    Image of System. Front orientation. Contains MultipleImages. Circuit Breakers. DIN-Rail Mount Electronic Circuit Breakers, Push-Button Style, 4 Circuits Controlled.
    Image of System. Front orientation. Contains MultipleImages. Circuit Breakers. DIN-Rail Mount Electronic Circuit Breakers, Push-Button Style, 8 Circuits Controlled.

    Push-Button Style,

    1 Circuit

    Controlled

    Push-Button Style

    4 Circuits Controlled

    Push-Button Style

    8 Circuits Controlled

    Adjustable-current breakers let you choose the current at which they’ll trip. As your operation changes, you can adjust when these breakers will trip rather than replacing the entire breaker.
    Breakers with digital input/outputs send and receive signals, so you can remotely check the status of your breaker, reset it, and turn it on and off.
    4 Circuits Controlled and 8 Circuits Controlled—Breakers that control 4 or 8 circuits allow you to individually set each circuit. If one trips, the others will keep working.
    No. of Circuits
    Controlled
    Current, A
    Voltage,
    V DC
    No. of
    Inputs
    No. of
    Outputs
    For DIN
    Rail Size, mm
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    Push-Button Style
    11, 2, 3, 4, 5, 6, 7, 8241135Spring-Clamp Terminal3.7"0.24"3.85"-10 to 145IP20
    3897N11000000
    42, 3, 4, 5, 6, 7, 8, 9, 10241235Spring-Clamp Terminal3.54"1.77"4.55"-10 to 145IP20
    3897N18000000
    82, 3, 4, 5, 6, 7, 8, 9, 10241235Spring-Clamp Terminal5"1.65"5.61"-10 to 145IP20
    3897N21000000
     
    Adjustable—IO Link
    Image of System. Front orientation. Contains MultipleImages. Circuit Breakers. DIN-Rail Mount Electronic Circuit Breakers, Push-Button Style, 4 Circuits Controlled.
    Image of System. Front orientation. Contains MultipleImages. Circuit Breakers. DIN-Rail Mount Electronic Circuit Breakers, Push-Button Style, 8 Circuits Controlled.

    Push-Button Style

    4 Circuits Controlled

    Push-Button Style

    8 Circuits Controlled

    Adjustable-current breakers let you choose the current at which they’ll trip. As your operation changes, you can adjust when these breakers will trip rather than replacing the entire breaker.
    Breakers with IO Link give you more control than breakers with digital input/outputs. Not only can you check the status to reset or turn your breaker on and off, but you can also adjust their current and view current in real-time. This is helpful when troubleshooting issues such as a breaker that repeatedly trips.
    4 Circuits Controlled and 8 Circuits Controlled—Breakers that control 4 or 8 circuits allow you to individually set each circuit. If one trips, the others will keep working.
    No. of Circuits
    Controlled
    Current, A
    Voltage,
    V DC
    For DIN
    Rail Size, mm
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    Push-Button Style
    41, 2, 3, 4, 5, 6, 7, 8, 9, 102435Spring-Clamp Terminal3.54"1.77"4.55"-10 to 145IP20
    3897N190000000
    81, 2, 3, 4, 5, 6, 7, 8, 9, 102435Spring-Clamp Terminal5"1.65"5.61"-10 to 145IP20
    3897N22000000
     

    Cutler-Hammer Load-Center Circuit Breakers

    Image of Product. Front orientation. Circuit Breakers. Cutler-Hammer Load-Center Circuit Breakers, 1 Pole—Toggle-Switch Style.

    1

    Pole—Toggle-Switch

    Style

    Install these circuit breakers into Cutler-Hammer CH series breaker boxes. Because these circuit breakers are thermal-magnetic, they trip two different ways. They either trip when heat is generated slowly by consistent low-level overload current or quickly when the magnetic coil senses a high-current short circuit.
    UL 489—They meet UL 489 requirements for branch circuit protection and are certified as current limiting, so they protect equipment by minimizing passing current during a short circuit.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage, V AC
    Freq.,
    Hz
    Breakthrough Current @ Voltage
    Mounting
    Location
    Wire Connection
    Wd.
    Specs.
    Met
    Each
    1 Pole—Toggle-Switch Style
     
    Thermal/Magnetic
    15120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal3/4"UL 4895259T71000000
    20120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal3/4"UL 4895259T7200000
    30120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal3/4"UL 4895259T7300000
     

    High-Temperature Panel-Mount Circuit Breakers

    Image of Product. Front orientation. Circuit Breakers. High-Temperature Panel-Mount Circuit Breakers , 1 Pole—Toggle-Switch Style.

    1

    Pole—Toggle-Switch

    Style

    Unlike breakers that trip thermally, these breakers have a hydraulic-magnetic trip mechanism, so they aren’t affected by changes in temperature. Instead, these circuit breakers trip when they hydraulically sense consistent low-level overload current, or they trip quickly when the magnetic coil senses a high-current short circuit. Use the threaded holes on the face to install them through panels, enclosure covers, or walls to keep them close to the equipment they protect.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    For Panel
    Cutout
    Mounting
    Holes
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Temp. Range,
    ° F
    Ht.
    Wd.
    Dia.
    Dp. Behind
    Panel
    No.
    of
    Thread
    Size
    Mounting Fasteners
    Included
    Wire Connection
    Ht.
    Wd.
    Each
    1 Pole—Toggle-Switch Style
    580V DC
    277V AC
    50/605,000 amp @ 277V AC
    7,500 amp @ 80V DC
    -40 to 1850.63"2"26-32
    NoQuick-Disconnect Terminal2"0.75"72015K111000000
    1080V DC
    277V AC
    50/605,000 amp @ 277V AC
    7,500 amp @ 80V DC
    -40 to 1850.63"2"26-32
    NoQuick-Disconnect Terminal2"0.75"72015K11200000
    1580V DC
    277V AC
    50/605,000 amp @ 277V AC
    7,500 amp @ 80V DC
    -40 to 1850.63"2"26-32
    NoQuick-Disconnect Terminal2"0.75"72015K11300000
    2080V DC
    277V AC
    50/605,000 amp @ 277V AC
    7,500 amp @ 80V DC
    -40 to 1850.63"2"26-32
    NoQuick-Disconnect Terminal2"0.75"72015K11400000
    3080V DC
    277V AC
    50/605,000 amp @ 277V AC
    7,500 amp @ 80V DC
    -40 to 1850.63"2"26-32
    NoQuick-Disconnect Terminal2"0.75"72015K11500000
    4080V DC
    250V AC
    50/601,500 amp @ 250V AC
    5,000 amp @ 80V DC
    -40 to 1851.45"0.76"2.573"26-32
    NoScrew Terminal2.5"0.75"72015K3600000
    50 80V DC
    250V AC
    50/601,500 amp @ 250V AC
    5,000 amp @ 80V DC
    -40 to 1851.45"0.76"2.573"26-32
    NoScrew Terminal2.5"0.75"72015K3500000
     

    Space-Saving Panel-Mount Branch Circuit Breakers

    Image of Product. Front orientation. Circuit Breakers. Space-Saving Panel-Mount Branch Circuit Breakers.
    Small enough to fit in tight spaces, these circuit breakers mount through panels. They are thermal, so they use the heat generated in overcurrent situations to trip the breaker.
    UL 489—These circuit breakers are UL 489-rated for branch circuit protection.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Screw On
    Current,
    A
    Voltage,
    V AC
    Freq., Hz
    Breakthrough Current
    @ Voltage
    For Panel
    Cutout Dia.
    Dp. Behind
    Panel
    Mounting
    Location
    Mounting Fasteners
    Included
    Wire Connection
    Quick-Disconnect
    Tab Wd.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    1 Pole—Push-Button Style
     
    Thermal
    1512050/605,000 amp @ 120V AC0.38"1.43"PanelYesQuick-Disconnect Terminal0.25"35 to 140UL 489UL Listed, CSA Certified
    3851K11000000
    2012050/605,000 amp @ 120V AC0.38"1.43"PanelYesQuick-Disconnect Terminal0.25"35 to 140UL 489UL Listed, CSA Certified
    3851K1200000
     