    14 Products

    Corrosion Resistant Breather Vents

    These breather vents withstand corrosion in damp environments. Use them to prevent excess vacuum and pressure in cylinders, gear boxes, and tanks and to block debris from entering equipment.
    Threaded NPT Male
    Image of Product. Polyethylene. Front orientation. Breather Vents. Corrosion Resistant Breather Vents, Threaded NPT Male, Polyethylene Body.

    Polyethylene

    Polyethylene Body and Fitting—Polyethylene breather vents can be cleaned with mineral spirits.
    Pipe
    Size
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Max. Temp.,
    ° F
    Ht.
    Dia.
    For Use With
    Removes Particle
    Size Down To, μm
    Each
    Polyethylene Body and Fitting
    1/8
    1 scfm @ 100 psi1001507/16"1/2"Air, Inert Gas100000000000000
    1/4
    3 scfm @ 100 psi1001501/2"11/16"Air, Inert Gas10000000000000
    3/8
    9 scfm @ 100 psi10015011/16"15/16"Air, Inert Gas10000000000000
    1/2
    10 scfm @ 100 psi10015011/16"15/16"Air, Inert Gas10000000000000
    3/4
    20 scfm @ 100 psi1001501 1/8"1 1/2"Air, Inert Gas10000000000000
    1
    22 scfm @ 100 psi1001501 3/8"1 7/8"Air, Inert Gas10000000000000
     

    Moisture Absorbing Breather Vents

    Keep moisture, dirt, and debris from entering your oil reservoirs. The silica gel inside these breather vents absorbs moisture from the air, preventing rust from forming inside your tanks. The gel changes from blue to pink as it becomes saturated, letting you know it needs to be replaced. A second filter blocks dust and other particles from getting inside. These breather vents allow air to flow in and out of your lubrication system, keeping excess vacuum or pressure from building up in cylinders, gear boxes, and tanks.
    Steel Body—NPT Male
    Image of Product. Front orientation. Breather Vents. Moisture Absorbing Breather Vents, Steel Body—NPT Male.
    Image of Product. Front orientation. Breather Vent Repair Kits. Moisture Absorbing Breather Vents.

    Repair Kits

    For an extended service life, use breather vents with a steel body. They are stronger than breather vents with plastic bodies and hold up better when exposed to chemicals. A window lets you check the color of the gel.
    Repair Kits—No need to replace the entire unit when the gel is saturated—use rebuild kits to add fresh gel and to replace the window, filters, and gaskets.
    Breather Vents
    Repair Kits
    Pipe
    Size
    For Tank Cap.,
    gal.
    Max. Flow Rate
    @ Pressure
    Max. Temp.,
    ° F
    Ht.
    Dia.
    For Use
    With
    Removes Particle
    Size Down To, μm
    Each
    Each
    Steel Body
    2
    1 to 80085 scfm @ 1 psi22011 1/2"10 1/8"Air10000000000000000000000000000000
    2
    1 to 1,30085 scfm @ 1 psi22013 3/4"10 1/8"Air100000000000000000000000000000
    2
    1 to 2,40080 scfm @ 1 psi22018 1/4"10 1/8"Air100000000000000000000000000000
    3
    1 to 4,000205 scfm @ 1 psi22019 1/4"15 1/2"Air100000000000000000000000000000
     