Light Meters





Measure light quality and intensity with these meters. They’re CE marked, so they meet European safety standards. They should not be used with lasers.
These meters measure brightness in footcandles and lux. One footcandle is one lumen per square foot. One lux is one lumen per square meter.
Use the data hold function to freeze a measurement on the screen, giving you time to write it down. Some meters also have an analog output, which transmits data to a recorder. Meters with minimum/maximum memory let you save and retrieve the high and low measurements you’ve taken. Meters that include an SD card store timestamped readings in Excel format for logging data and transferring it to a PC.
All of these meters measure general lighting. Style A meters measure white LED light. Style B meters measure colored LED light. Style C-E meters measure general lighting only—they are not for use with LED lights.

Light Measurement Range | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Light Technology | For LED Color | Footcandles | Lux | Accuracy | Batteries Included | Features | Includes | Each | |
Meters | |||||||||
LED, CFL, Fluorescent, Halogen, Incandescent, Metal Halide, High-Pressure Sodium, Mercury Vapor | White | 0-40,000 | 0-400,000 | ±3% | Yes | Auto Power Off, Data Hold, Min./Max. Memory | Protective Pouch | 00000000 | 0000000 |
Meters with Calibration Certificate | |||||||||
LED, CFL, Fluorescent, Halogen, Incandescent, Metal Halide, High-Pressure Sodium, Mercury Vapor | White | 0-40,000 | 0-400,000 | ±3% | Yes | Auto Power Off, Data Hold, Min./Max. Memory | Protective Pouch | 00000000 | 000000 |

Light Measurement Range | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Light Technology | For LED Color | Footcandles | Lux | Accuracy | Light Sensor Cable Lg., ft. | Batteries Included | Features | Includes | Each | |
Meters | ||||||||||
LED, CFL, Fluorescent, Halogen, Incandescent, Metal Halide, High-Pressure Sodium, Mercury Vapor | Blue, Green, Red, White, Yellow | 0-40,000 | 0-400,000 | ±3% | 5 | Yes | Auto Power Off, Data Hold, Min./Max. Memory, Storage for up to 99 readings | Case | 00000000 | 0000000 |
Meters with Calibration Certificate | ||||||||||
LED, CFL, Fluorescent, Halogen, Incandescent, Metal Halide, High-Pressure Sodium, Mercury Vapor | Blue, Green, Red, White, Yellow | 0-40,000 | 0-400,000 | ±3% | 5 | Yes | Auto Power Off, Data Hold, Min./Max. Memory, Storage for up to 99 readings | Case | 000000000 | 000000 |

Light Measurement Range | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Light Technology | Footcandles | Lux | Accuracy | Light Sensor Cable Lg., ft. | Output Type | Batteries Included | Features | Each | |
Meters | |||||||||
CFL, Fluorescent, Halogen, Incandescent, Metal Halide, High-Pressure Sodium, Mercury Vapor | 0-5,000 | 0-50,000 | ±5% | 3 | Analog | Yes | Auto Power Off, Data Hold | 00000000 | 0000000 |
Meters with Calibration Certificate | |||||||||
CFL, Fluorescent, Halogen, Incandescent, Metal Halide, High-Pressure Sodium, Mercury Vapor | 0-5,000 | 0-50,000 | ±5% | 3 | Analog | Yes | Auto Power Off, Data Hold | 00000000 | 000000 |

Each | ||
00000000 | 000000 |

Light Measurement Range | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Light Technology | Footcandles | Lux | Accuracy | Light Sensor Cable Lg., ft. | Batteries Included | Features | Includes | Each | |
Meters | |||||||||
CFL, Fluorescent, Halogen, Incandescent, Metal Halide | 0-10,000 | 0-100,000 | ±4% | 3 | Yes | Auto Power Off, Data Hold, Min./Max. Memory, Storage for up to 99 readings | 2 GB Standard SD Card, Case | 000000000 | 0000000 |
Meters with Calibration Certificate | |||||||||
CFL, Fluorescent, Halogen, Incandescent, Metal Halide | 0-10,000 | 0-100,000 | ±4% | 3 | Yes | Auto Power Off, Data Hold, Min./Max. Memory, Storage for up to 99 readings | 2 GB Standard SD Card, Case | 000000000 | 000000 |

Light Measurement Range | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Light Technology | Footcandles | Lux | Accuracy | Light Sensor Cable Lg., ft. | Batteries Included | Features | Includes | Each | |
Meters | |||||||||
Fluorescent, Incandescent, Metal Halide, Mercury Vapor | 0-40,000 | 0-400,000 | ±5% | 2 | Yes | Data Hold, Min./Max. Memory | Case, Protective Pouch | 000000000 | 0000000 |
Meters with Calibration Certificate | |||||||||
Fluorescent, Incandescent, Metal Halide, Mercury Vapor | 0-40,000 | 0-400,000 | ±5% | 2 | Yes | Data Hold, Min./Max. Memory | Case, Protective Pouch | 000000000 | 000000 |
Gloss Meters

Confirm that each product is as shiny as the last. These meters measure the gloss of paint and coatings as well as metal, ceramic, and granite surfaces. All come with a USB cord to transfer data to PCs.
Meters with a 60° field of view can evaluate the gloss of most standard, semi-gloss surfaces.
Meters with a 20°, 60°, and 85° field of view can evaluate low-gloss/matte and high-gloss surfaces in addition to semi-gloss surfaces—their gloss measuring range is 10 times as broad as meters with only a 60° field of view. They’re compatible with a free app that lets you use your Android device to start and stop recording and send data using Bluetooth.
These meters come with a calibration block, and you should calibrate them before each reading. Lay the block on a flat surface and press the calibration button on your meter. Position the meter on top of the block, and your meter will calibrate.
Sensing Area | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Measuring Range | Measuring Increments | Accuracy | Repeatability | Field of View | Ht. | Wd. | Dp. | Lg., mm | Wd., mm | Data Connection Type | Operating System Compatibility | Batteries Included | Battery Type | Includes | Each | |
For Use On Ceramic, Metal, Paper, Plastic, Stone, Wood | ||||||||||||||||
0-200 GU | 0.1 GU | ±1.5% | 0.2% | 60° | 5 1/2" | 3" | 1 1/2" | 20 | 10 | USB-C | Windows 7 or Later | Yes | Rechargeable | 3 ft. Long USB Cord, AC Adapter, Calibration Block, Microfiber Cloth | 0000000 | 0000000 |
0-2,000 GU | 1 GU | ±1.5% | 0.2% | 20°, 60°, 85° | 6" | 3" | 2" | 39 | 9 | Bluetooth, Mini USB-B | Android 4.2 or Later, Windows 7 or Later | Yes | Disposable | 3 ft. Long USB Cord, Calibration Block | 0000000 | 00000000 |
Light Monitors

Continuously monitor light quality, intensity, and density in light-sensitive environments, such as photo labs and pharmaceutical manufacturing facilities. While light meters spot-measure intensity in a specific area, these monitors give you detailed readings for an extended period. They combine a light sensor, transmitter, and digital display unit. Configurable alarm outputs notify you when light levels are outside of a set range. These monitors are IP rated for protection against dust and splashing water.
A 5 ft. cable lets you keep your display visible while you check light levels in dim or hard-to-reach areas. You can mount the digital display to your wall for easy viewing with the included fasteners. If you want to mount the transmitter to a wall or onto DIN rail, connect it to the included adapter rail.
For setup, connect the light meter to the transmitter, and the transmitter to the display. Everything needs to be wired together with 4-20 mA wire (not included). You need to wire the transmitter to a 90 to 260 ACV power supply. Wiring instructions are included.
Transmitter | Display Console | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Light Measurement Range | Measuring Increments | Accuracy | Input Voltage Range | Output Current Range | No. of Relay Outputs | Switching Current @ Voltage | Probe Cable Lg., ft. | Mounting Fasteners Included | Environmental Rating | Mounting Fasteners Included | Environmental Rating | Features | Each | |
0-50,000 lx | 1 lx | ±5% | 90-260V AC | 4-20mA | 2 | 5 A @ 240 V AC | 5 | No | IP54 | Yes | IP65 | Configurable Alarm Outputs | 0000000 | 0000000 |
Indoor Environmental Meters
Measure airflow, light, humidity, and temperature with a single, pocket-sized tool. These meters have built-in sensors that can detect multiple environmental factors in your plant or office. This helps you maintain safety compliance and track energy efficiency. A data hold function lets you freeze a measurement on the screen, giving you time to write it down. Additionally, they have the memory to store your high and low measurements. These meters are also known as hygro-thermo-anemometers.
They’re CE marked as compliant with European health, safety, and environmental standards.
Plug in an optional thermocouple probe to measure the surface temperatures of hard-to-reach areas, such as duct walls.

Light Measurement Range | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Measures | Airflow | For Light Technology | Footcandles | Lux | Relative Humidity | Temp. Range, °F | Display | Ht. | Wd. | Dp. | Blade Dia. | Batteries Included | Specifications Met | Each | |
Fan Meter | |||||||||||||||
Airflow, Light, Relative Humidity, Temperature | 80-5,905 fpm 0.95-65 mph 0.85-55 kn 0.4-25 mm/sec. 1.45-105 km/hr. | Halogen | 0-1,855 | 0-15,000 | 95% | 35° to 120° | LCD | 6" | 2 1/4" | 1 1/4" | 1" | Yes | CE Marked | 0000000 | 0000000 |

Thermocouple Type | Cable Lg., ft. | Temp. Range, °F | Each | |
K | 3 | -40° to 482° | 0000000 | 000000 |