McMaster-Carr logo
    Filter by
    Housing Material
    Discharge Pipe Size
    Industrial Info Compare
    Maximum Flow Rate @ 25 psi
    Intake Pipe Size
    Industrial Info Compare
    Maximum Pressure
    Electrical Phase
    Shaft Diameter
    Discharge Thread Type
    Industrial Info Compare
    Intake Connection Port
    Discharge Connection Port
    Intake Connection
    DFARS Specialty Metals
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    18 Products

    Constant-Flow-Rate Gear Pumps for Water

    Image of Product. Front orientation. Gear Pumps. Constant-Flow-Rate Gear Pumps for Water.
    These gear pumps produce a smooth flow of liquid for applications such as cooling engines, powering hydraulic equipment, and extracting liquid from holding tanks. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward. Do not use with solids. Pumps can be used in dusty, dirty, and damp environments.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Cannot Be Sold to Canada—Pumps that cannot be sold to Canada are restricted by local energy efficiency requirements.
    Intake
    (NPT)
    Discharge
    (NPT)
    Overall
    Max. Flow
    Rate, gpm
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current
    Pipe
    Size
    Gender
    Pipe
    Size
    Gender
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Cannot Be
    Sold To
    Each
    115V AC/230V AC, Single Phase—Without Thermal Overload Protection
     
    Hardwire
    2.1150100,00032 to 1401/27.4 amp/3.7 amp1/4
    Female1/4
    FemaleTotally Enclosed16 1/16"8 3/16"8"4272K31000000000
    8.5150100,00032 to 140112.8 amp/6.4 amp1/2
    Female1/2
    FemaleTotally Enclosed18 1/8"9 3/16"9"4272K2100000000
     
    230V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    10.2150100,00032 to 1401 1/24.4 amp/2.2 amp1/2
    Female1/2
    FemaleTotally Enclosed Fan-Cooled (TEFC)19 13/16"9 5/16"7 1/4"Canada4272K2200000000
    23150100,00032 to 14038.4 amp/4.2 amp1
    Female1
    FemaleTotally Enclosed Fan-Cooled (TEFC)25 1/8"10 5/16"9 1/16"Canada4272K2300000000
     

    Constant-Flow-Rate Gear Pumps without Motor for Water

    Image of Product. Front orientation. Gear Pumps. Constant-Flow-Rate Gear Pumps without Motor for Water.
    These gear pumps have a bronze housing and gears for use with water. Select your own motor to tailor them to your application. Use a NEMA 56C frame electric motor with a coupling and belt/pulley drive. They produce a smooth flow of liquid for water delivery. All are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Do not use with solids.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Required
    hp, hp
    Intake (NPT)
    Discharge (NPT)
    Overall
    Shaft
    Max. Flow Rate @
    25 psi, gpm
    Max. Flow
    Rate
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    @ 25
    psi
    @ 100
    psi
    Pipe
    Size
    Connection
    Gender
    Pipe
    Size
    Connection
    Gender
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Each
    For 1,725 rpm Maximum Motor Speed
    1.82.1 gpm34515017,300-20 to 2101/81/41/4
    ThreadedFemale1/4
    ThreadedFemale6 3/16"2 1/2"3"1/2"1 13/16"1 7/8"4271K10000000
    10.210.6 gpm34515017,300-20 to 2103/41 3/41/2
    ThreadedFemale1/2
    ThreadedFemale6 7/8"3 3/4"4 1/4"5/8"2"2 3/4"4271K14000000
    1919.8 gpm34515017,300-20 to 2101 1/22 3/43/4
    ThreadedFemale3/4
    ThreadedFemale7 1/16"4 3/8"5 1/4"5/8"2 3/16"3 9/16"4271K15000000
    22.223.5 gpm34515017,300-20 to 2101 1/22 3/41
    ThreadedFemale1
    ThreadedFemale7 5/16"4 5/16"5 1/4"5/8"2 3/16"3 9/16"4271K16000000
     
    For 1,750 rpm Maximum Motor Speed
    77.2 gpm34515017,300-40 to 2103/41 1/23/8
    ThreadedFemale3/8
    ThreadedFemale6 9/16"3 3/4"4 1/4"5/8"2 1/16"2 3/4"4271K13000000
     

    Harsh Environment Self-Priming Dewatering Pumps

    Image of Product. Front orientation. Dewatering Pumps. Harsh Environment Self-Priming Dewatering Pumps.
    This pump has a totally enclosed nonventilated (TENV) motor that is cooled by the liquid being pumped. Also known as a flexible impeller pump, it creates a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. Mount up to 6 feet above your liquid source. Pump can pass solids up to 1/4" in diameter without clogging, so there’s no need to filter sediment and debris. A handle makes it convenient for on-the-go removal of bilge water, waste oil, and spills. Pump can also be used to cool marine engines and drain liquid from holding tanks.
    Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
    Overall
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Solids
    Dia.
    Removes Water
    Down To
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Intake Size
    Discharge Size
    Ht.
    Wd.
    Lg.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug with 8 ft. Long Cord
    5 4/5301/4"Not Rated12560 to 1801/44.21/2 NPT Female, 3/4 GHT Male1/2 NPT Female, 3/4 GHT Male9"5 5/8"7 3/8"4381K670000000
     

    Self-Priming Circulation Pumps without Motor for Oil

    Image of Product. Front orientation. Centrifugal Pumps. Self-Priming Circulation Pumps without Motor for Oil.
    Use these pumps to move lubricating oil such as hydraulic and motor oil. Also known as flexible impeller pumps, they create a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. The impeller resists clogging and wear. Select a spark-free air motor for hazardous environments or attach an electric motor with a speed reducer or a belt pulley to alter the pump speed.
    Repair kits (sold separately) include components such as impellers, O-rings, and seal lips.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Shaft
    Overall
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max.
    Viscosity
    Temp. Range,
    ° F
    Req. Power,
    hp
    Intake Connection
    Type
    Discharge Connection
    Type
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Ht.
    Lg.
    Wd.
    Each
    For 500 rpm to 2,100 rpm Motor Speed
    11.55021Not Rated50 to 1801/31/2 Female NPT1/2 Female NPT5/8"1 1/8"1 15/16"3 13/16"4 1/2"4 1/8"4281K240000000
    255026Not Rated50 to 1803/41 Female NPT1 Female NPT5/8"2 1/4"1 7/8"3 9/16"6 3/8"4 3/4"4281K26000000
     
    Repair Kits

    Self-Priming Circulation Pumps without Motor for Water

    Image of Product. Front orientation. Centrifugal Pumps. Self-Priming Circulation Pumps without Motor for Water.
    Also known as flexible impeller pumps, these create a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. The impeller resists clogging and wear. Select a spark-free air motor for hazardous environments or attach an electric motor with a speed reducer or a belt pulley to alter the pump speed.
    Repair kits (sold separately) include components such as impellers, O-rings, and seal lips.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Overall
    Shaft
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max.
    Viscosity
    Temp. Range,
    ° F
    Req. Power,
    hp
    Intake Connection
    Type
    Discharge Connection
    Type
    Ht.
    Lg.
    Wd.
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Each
    For 500 rpm to 2,100 rpm Motor Speed
    136026Not Rated50 to 1801/31/2 Female NPT1/2 Female NPT3 13/16"4 1/2"4 1/8"5/8"1 1/8"1 15/16"4281K210000000
    27.96026Not Rated50 to 1803/41 Female NPT1 Female NPT3 9/16"6 3/8"4 3/4"5/8"2 1/4"1 7/8"4281K23000000
     
    Repair Kits
    back to top