McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    128 Products

    Wraparound Cable Entry Panels

    Attach a cable entry panel to cord without removing connectors and rewiring. These cable entry panels have a two-piece design to fit around cables with connectors. Choose a housing and then select inserts (sold separately). Inserts have a slit, eliminating the need to thread cable through them.
    Knockout-Mount Housings
    Image of Product. Front orientation. Cable Entry Panels. Wraparound Cable Entry Panels, Knockout Mount.
    Image of Product. Knockout-Mount Housing Shown Open. Front orientation. Exploded view. Cable Entry Panels. Wraparound Cable Entry Panels, Knockout Mount.

    Knockout-Mount

    Housing Shown

    Open

    Image of Specification. 1 Small Insert. Front orientation. For Small Inserts. Wraparound Cable Entry Panels, Knockout Mount, For 1 Insert.

    1

    Small

    Insert

    Image of Specification. 2 Small Inserts. Front orientation. For 2 Inserts. Wraparound Cable Entry Panels, Knockout Mount, For Small Inserts.

    2 Small

    Inserts

    Image of Specification. 4 Small Inserts. Front orientation. For Small Inserts. Wraparound Cable Entry Panels, Knockout Mount, For 4 Inserts.

    4 Small

    Inserts

    For
    Insert
    For No.
    of Inserts
    Shape
    For Knockout
    Trade Size
    Ht.
    Wd.
    Thread
    Type
    For Max.
    Panel Thk.
    Temp. Range,
    ° F
    Features
    Enclosure
    Rating
    Certification
    Each
    Gray Polycarbonate
    1 SmallStraightM20
    0.83"0.83"Metric
    0.31"-20 to 190Nylon Plastic Locknut, Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    0000000000000
    1 SmallStraightM25
    0.83"0.83"Metric
    0.31"-20 to 190Nylon Plastic Locknut, Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    0000000000000
    1 SmallStraightM32
    0.83"0.83"Metric
    0.31"-20 to 190Nylon Plastic Locknut, Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    1 SmallStraightM40
    0.83"0.83"Metric
    0.31"-20 to 190Nylon Plastic Locknut, Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    0000000000000
    2 SmallStraightM50
    0.83"0.83"Metric
    0.31"-20 to 190Nylon Plastic Locknut, Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    4 SmallStraightM63
    0.83"0.83"Metric
    0.31"-20 to 190Nylon Plastic Locknut, Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
     
    Surface-Mount Housings
    Image of Product. Front orientation. Cable Entry Panels. Wraparound Cable Entry Panels, Surface Mount.
    Image of Product. Surface-Mount Housing Shown Open. Front orientation. Exploded view. Cable Entry Panels. Wraparound Cable Entry Panels, Surface Mount.

    Surface-Mount

    Housing Shown

    Open

    Image of Specification. 2 Small Inserts and 1 Large Insert. Front orientation. For Large Inserts. Wraparound Cable Entry Panels, Surface Mount, For Small Inserts, For 2 Inserts, For 1 Insert.
    Image of Specification. 2 Small Inserts and 2 Large Inserts. Front orientation. For Large Inserts. Wraparound Cable Entry Panels, Surface Mount, For Small Inserts, For 2 Inserts.
    Image of Specification. 4 Small Inserts and 1 Large Insert. Front orientation. For Large Inserts. Wraparound Cable Entry Panels, Surface Mount, For 4 Inserts, For 1 Insert, For Small Inserts.

    2 Small Inserts

    and 1 Large

    Insert

    2 Small Inserts and 2 Large

    Inserts

    4 Small Inserts and 1

    Large Insert

    Image of Specification. 4 Small Inserts (2.9" Lg.). Front orientation. For Small Inserts. Wraparound Cable Entry Panels, Surface Mount, For 4 Inserts, 2.9" Long.
    Image of Specification. 4 Small Inserts (4.7" Lg). Front orientation. For Small Inserts. Wraparound Cable Entry Panels, Surface Mount, For 4 Inserts, 4.7" Long, For 3.5" Panel Cutout Length.
    Image of Specification. 5 Small Inserts. Front orientation. For Small Inserts. Wraparound Cable Entry Panels, Surface Mount, For 5 Inserts.

    4 Small

    Inserts

    (2.9" Lg.)

    4 Small Inserts (4.7"

    Lg)

    5 Small Inserts

    Image of Specification. 6 Small Inserts. Front orientation. For Small Inserts. Wraparound Cable Entry Panels, Surface Mount, For 6 Inserts.
    Image of Specification. 6 Small Inserts and 1 Large Insert. Front orientation. For Large Inserts. Wraparound Cable Entry Panels, Surface Mount, For Small Inserts, For 6 Inserts, For 1 Insert.
    Image of Specification. 8 Small Inserts. Front orientation. For Small Inserts. Wraparound Cable Entry Panels, Surface Mount, For 8 Inserts.

    6 Small Inserts

    6 Small Inserts and 1 Large

    Insert

    8 Small Inserts

    Image of Specification. 10 Small Inserts. Front orientation. For Small Inserts. Wraparound Cable Entry Panels, Surface Mount, For 10 Inserts.
    Image of Specification. 1 Large Insert. Front orientation. For Large Inserts. Wraparound Cable Entry Panels, Surface Mount, For 1 Insert.
    Image of Specification. 2 Large Inserts. Front orientation. For Large Inserts. Wraparound Cable Entry Panels, Surface Mount, For 2 Inserts.

    10 Small Inserts

    1 Large

    Insert

    2 Large Inserts

    For
    Insert
    For Panel
    Cutout
    Mounting
    Holes
    For No. of
    Inserts
    Shape
    Ht.
    Wd.
    Lg.
    Wd.
    Dp.
    Lg.
    Wd.
    Mounting Fasteners
    Included
    No.
    of
    Dia.
    Temp. Range,
    ° F
    Features
    Enclosure
    Rating
    Certification
    Each
    Black Nylon
    2 Small
    1 Large
    Straight0.83"
    1.63"
    0.83"
    1.63"
    3.9"2.3"0.7"2.5"1.6"No40.22"-20 to 190Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    00000000000000
    2 Small
    2 Large
    Straight0.83"
    1.63"
    0.83"
    1.63"
    5.8"2.3"0.7"4.4"1.6"No40.22"-20 to 190Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    0000000000000
    4 Small
    1 Large
    Straight0.83"
    1.63"
    0.83"
    1.63"
    4.7"2.3"0.7"3.4"1.6"No40.22"-20 to 190Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    0000000000000
    4 SmallStraight0.83"0.83"2.9"2.3"0.7"1.8"1.8"No40.22"-20 to 190Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    4 SmallStraight0.83"0.83"4.7"2.3"0.7"3.5"0.8"No40.22"-20 to 190Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    0000000000000
    5 SmallStraight0.83"0.83"5.8"2.3"0.7"4.4"0.8"No40.22"-20 to 190Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    0000000000000
    6 Small
    1 Large
    Straight0.83"
    1.63"
    0.83"
    1.63"
    5.8"2.3"0.7"4.4"1.6"No40.22"-20 to 190Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    0000000000000
    6 SmallStraight0.83"0.83"3.9"2.3"0.7"2.6"1.4"No40.22"-20 to 190Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    8 SmallStraight0.83"0.83"4.7"2.3"0.7"3.4"1.4"No40.22"-20 to 190Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    10 SmallStraight0.83"0.83"5.8"2.3"0.7"4.4"1.4"No40.22"-20 to 190Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    1 LargeStraight1.63"1.63"2.9"2.3"0.7"1.6"1.4"No40.22"-20 to 190Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    0000000000000
    2 LargeStraight1.63"1.63"4.7"2.3"0.7"3.3"1.4"No40.22"-20 to 190Rubber GasketNEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    0000000000000
     
    Inserts
    Image of Product. Insert for 0 Cords. Front orientation. Cable Entry Panels. Wraparound Cable Entry Panels, Inserts, Gray Rubber, For 0 Total Cords.
    Image of Product. Insert for 1 Cord. Front orientation. Cable Entry Panels. Wraparound Cable Entry Panels, Inserts, Gray Rubber, For 1 Total Cord.
    Image of Product. Insert for 2 Cords. Front orientation. Cable Entry Panels. Wraparound Cable Entry Panels, Inserts, Gray Rubber, For 2 Total Cords.
    Image of Product. Insert for 4 Cords. Front orientation. Cable Entry Panels. Wraparound Cable Entry Panels, Inserts, Gray Rubber, For 4 Total Cords.

    Insert for 0 Cords

    Insert for 1 Cord

    Insert for 2 Cords

    Insert for 4 Cords

    For Total
    No. of Cords
    Shape
    For Cord OD (No.
    of Cords)
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Enclosure Rating
    Certification
    Each
    Gray Rubber
     
    Small Insert
    0Straight0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    0000000000000
    1Straight0.04" to 0.07"0.83"0.83"0.75"-20 to 190NEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.08" to 0.11"0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.12" to 0.15"0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.16" to 0.19"0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.2" to 0.23"0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    00000000000
    1Straight0.24" to 0.27"0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    00000000000
    1Straight0.28" to 0.31"0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    00000000000
    1Straight0.32" to 0.35"0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    00000000000
    1Straight0.36" to 0.39"0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    00000000000
    1Straight0.4" to 0.43"0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    00000000000
    1Straight0.44" to 0.47"0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    00000000000
    1Straight0.48" to 0.51"0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    00000000000
    1Straight0.52" to 0.54"0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    00000000000
    1Straight0.55" to 0.58"0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.59" to 0.62"0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.63"0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.67"0.83"0.83"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    2Straight0.04"0.83"0.83"0.75"-20 to 190NEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component
    000000000000
    2Straight0.08"0.83"0.83"0.75"-20 to 190NEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component
    000000000000
    2Straight0.12"0.83"0.83"0.75"-20 to 190NEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component
    000000000000
    2Straight0.16"0.83"0.83"0.75"-20 to 190NEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component
    000000000000
    2Straight0.17" to 0.2"0.83"0.83"0.75"-20 to 190NEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component
    00000000000
    2Straight0.21" to 0.24"0.83"0.83"0.75"-20 to 190NEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component
    00000000000
    2Straight0.25" to 0.28"0.83"0.83"0.75"-20 to 190NEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component
    00000000000
    2Straight0.29" to 0.32"0.83"0.83"0.75"-20 to 190NEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component
    00000000000
    4Straight0.08"0.83"0.83"0.75"-20 to 190NEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component
    000000000000
    4Straight0.12"0.83"0.83"0.75"-20 to 190NEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component
    000000000000
    4Straight0.16"0.83"0.83"0.75"-20 to 190NEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component
    00000000000
    4Straight0.2"0.83"0.83"0.75"-20 to 190NEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component
    00000000000
    4Straight0.24"0.83"0.83"0.75"-20 to 190NEMA 12, IP54
    UL Recognized Component, C-UL Recognized Component
    00000000000
     
    Large Insert
    0Straight1.63"1.63"0.75"-20 to 190NEMA 4X, IP54
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.63" to 0.66"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.67" to 0.7"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.71" to 0.74"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.75" to 0.78"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.79" to 0.82"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.83" to 0.86"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.87" to 0.9"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.91" to 0.94"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.95" to 0.97"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight0.98" to 1.01"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight1.02" to 1.05"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight1.06" to 1.09"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    00000000000
    1Straight1.1" to 1.13"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight1.14" to 1.17"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight1.18" to 1.21"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight1.22" to 1.25"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight1.26" to 1.29"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight1.3" to 1.33"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
    1Straight1.34" to 1.37"1.63"1.63"0.75"-20 to 190NEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component
    000000000000
     

    Wet-Location Multi-Diameter Cable Entry Panels

    Modify these cable entry panels to get the right fit for your cord even when you don't know your exact cord diameter. They have a frame with a two-piece rubber insert that fits around cables with connectors. The insert is made of layers that you peel away until you reach the size that fits your cord.
    Replacement inserts allow you to change cord sizes and configurations.
    Black Nylon
    Image of Product. Front orientation. Cable Entry Panels. Wet-Location Multi-Diameter Cable Entry Panels, Black Nylon.
    Nylon is chemical resistant.
    NEMA 4X Enclosure Rating, NEMA 13 Enclosure Rating, IP66 Enclosure Rating, and IP67 Enclosure Rating—Panels are rated IP66 and IP67 for protection from washdowns and temporary water submersion and NEMA 4X and 13 for indoor and outdoor protection against corrosion, water projected from a hose, and oil/coolant spraying.
    For Panel
    Cutout
    For Total
    No. of Cords
    For Cord OD (No. of Cords)
    Mounting
    Location
    Lg.
    Wd.
    Dp.
    Dia.
    Lg.
    Wd.
    Temp. Range,
    ° F
    Enclosure Rating
    Each
    40.14" to 0.65"Surface3.8"2.8"1.2"2"-40 to 140NEMA 4X, NEMA 13, IP66, IP67
    000000000000
    70.14" to 0.65" (6), 0.37" to 1.28" (1)Surface6.6"2.8"1.2"4.3"1.5"-40 to 140NEMA 4X, NEMA 13, IP66, IP67
    000000000000
    100.14" to 0.65"Surface6.6"2.8"1.2"4.3"1.5"-40 to 140NEMA 4X, NEMA 13, IP66, IP67
    000000000000
    100.14" to 0.65" (8), 0.37" to 1.28" (2)Surface9"3.5"1.3"6.2"1.5"-40 to 140NEMA 4X, NEMA 13, IP66, IP67
    000000000000
    160.14" to 0.65"Surface9"3.5"1.3"6.2"1.5"-40 to 140NEMA 4X, NEMA 13, IP66, IP67
    000000000000
    Replacement Inserts for Black Nylon Cable Entry Panels
    White Painted Steel
    Image of Product. Front orientation. Cable Entry Panels. Wet-Location Multi-Diameter Cable Entry Panels, White Painted Steel.
    NEMA 4X Enclosure Rating, NEMA 13 Enclosure Rating, IP66 Enclosure Rating, and IP67 Enclosure Rating—Panels are rated IP66 and IP67 for protection from washdowns and temporary water submersion and NEMA 4X and 13 for indoor and outdoor protection against corrosion, water projected from a hose, and oil/coolant spraying.
    For Panel
    Cutout
    For Total
    No. of Cords
    For Cord OD (No. of Cords)
    Mounting
    Location
    Lg.
    Wd.
    Dp.
    Lg.
    Wd.
    Max.
    Thk.
    Temp. Range,
    ° F
    Enclosure Rating
    Each
    40.37" to 1.28"Panel9.21"3.66"1.65"7.4"2.8"0.16"-40 to 175NEMA 4X, NEMA 13, IP66, IP67
    0000000000000
    100.14" to 0.65" (8), 0.37" to 1.28" (2)Panel9.21"3.66"1.65"7.4"2.8"0.16"-40 to 175NEMA 4X, NEMA 13, IP66, IP67
    000000000000
    160.14" to 0.65"Panel9.21"3.66"1.65"7.4"2.8"0.16"-40 to 175NEMA 4X, NEMA 13, IP66, IP67
    000000000000
    190.14" to 0.41" (12), 0.14" to 0.65" (6), 0.37" to 1.28" (1)Panel9.21"3.66"1.65"7.4"2.8"0.16"-40 to 175NEMA 4X, NEMA 13, IP66, IP67
    000000000000
    Replacement Inserts for White Painted and Stainless Steel Cable Entry Panels
    Stainless Steel
    Image of Product. Front orientation. Cable Entry Panels. Wet-Location Multi-Diameter Cable Entry Panels, Stainless Steel.
    NEMA 4X Enclosure Rating, NEMA 13 Enclosure Rating, IP66 Enclosure Rating, and IP67 Enclosure Rating—Panels are rated IP66 and IP67 for protection from washdowns and temporary water submersion and NEMA 4X and 13 for indoor and outdoor protection against corrosion, water projected from a hose, and oil/coolant spraying.
    IP69K Enclosure Rating—Stainless steel panels are also rated IP69K for protection against high-pressure, high-temperature jets of water and have excellent corrosion resistance.
    For Panel
    Cutout
    For Total
    No. of Cords
    For Cord OD (No. of Cords)
    Mounting
    Location
    Lg.
    Wd.
    Dp.
    Lg.
    Wd.
    Max.
    Thk.
    Temp. Range,
    ° F
    Enclosure Rating
    Each
    40.37" to 1.28"Panel9.21"3.66"1.65"7.4"2.8"0.16"-40 to 175NEMA 4X, NEMA 13, IP66, IP67, IP69K
    0000000000000
    100.14" to 0.65" (8), 0.37" to 1.28" (2)Panel9.21"3.66"1.65"7.4"2.8"0.16"-40 to 175NEMA 4X, NEMA 13, IP66, IP67, IP69K
    000000000000
    160.14" to 0.65"Panel9.21"3.66"1.65"7.4"2.8"0.16"-40 to 175NEMA 4X, NEMA 13, IP66, IP67, IP69K
    000000000000
    190.14" to 0.41" (12), 0.14" to 0.65" (6), 0.37" to 1.28" (1)Panel9.21"3.66"1.65"7.4"2.8"0.16"-40 to 175NEMA 4X, NEMA 13, IP66, IP67, IP69K
    000000000000
    Replacement Inserts for White Painted and Stainless Steel Cable Entry Panels

    Low-Profile Submersible Break-Through Cable Entry Panels

    The face of these panels is flush with the cable-entry point for a seamless appearance. They have a thin, flexible seal that covers the holes until you push a cord through.
    Knockout Mount
    Image of Product. For 3 Cords. Front orientation. Cable Entry Panels. Low-Profile Submersible Break-Through Cable Entry Panels, Knockout Mount, Gray Nylon, For 3 Total Cords.
    Image of Product. For 4 Cords. Front orientation. Cable Entry Panels. Low-Profile Submersible Break-Through Cable Entry Panels, Knockout Mount, Gray Nylon, For 4 Total Cords.
    Image of Product. For 7 Cords. Front orientation. Cable Entry Panels. Low-Profile Submersible Break-Through Cable Entry Panels, Knockout Mount, Gray Nylon, For 7 Total Cords.
    Image of Product. For 8 Cords. Front orientation. Cable Entry Panels. Low-Profile Submersible Break-Through Cable Entry Panels, Knockout Mount, Gray Nylon, For 8 Total Cords.

    For 3 Cords

    For 4 Cords

    For 7 Cords

    For 8 Cords

    Image of Product. For 9 Cords. Front orientation. Cable Entry Panels. Low-Profile Submersible Break-Through Cable Entry Panels, Knockout Mount, Gray Nylon, For 9 Total Cords.
    Image of Product. For 10 Cords. Front orientation. Cable Entry Panels. Low-Profile Submersible Break-Through Cable Entry Panels, Knockout Mount, Gray Nylon, For 10 Total Cords.
    Image of Product. For 12 Cords. Front orientation. Cable Entry Panels. Low-Profile Submersible Break-Through Cable Entry Panels, Knockout Mount, Gray Nylon, For 12 Total Cords.
    Image of Product. For 13 Cords. Front orientation. Cable Entry Panels. Low-Profile Submersible Break-Through Cable Entry Panels, Knockout Mount, Gray Nylon, For 13 Total Cords.

    For 9 Cords

    For 10 Cords

    For 12 Cords

    For 13 Cords

    Image of Product. For 14 Cords. Front orientation. Cable Entry Panels. Low-Profile Submersible Break-Through Cable Entry Panels, Knockout Mount, Gray Nylon, For 14 Total Cords.
    Image of Product. For 19 Cords. Front orientation. Cable Entry Panels. Low-Profile Submersible Break-Through Cable Entry Panels, Knockout Mount, Gray Nylon, For 19 Total Cords.
    Image of Product. For 35 Cords. Front orientation. Cable Entry Panels. Low-Profile Submersible Break-Through Cable Entry Panels, Knockout Mount, Gray Nylon, For 35 Total Cords.
    Image of Product. For 78 Cords. Front orientation. Cable Entry Panels. Low-Profile Submersible Break-Through Cable Entry Panels, Knockout Mount, Gray Nylon, For 78 Total Cords.

    For 14 Cords

    For 19 Cords

    For 35 Cords

    For 78 Cords

    NEMA 4X Enclosure Rating, NEMA 12 Enclosure Rating, IP66 Enclosure Rating, and IP68 Enclosure Rating—Panels are rated IP66, IP68, NEMA 4X, and NEMA 12 for protection from continuous submersion, washdowns and oil/coolant splashing.
    For Total
    No. of Cords
    Shape
    For Cord OD (No. of Cords)
    For Knockout
    Trade Size
    Thread
    Type
    For Max.
    Panel Thk.
    Temp. Range,
    ° F
    Features
    Enclosure Rating
    Certification
    Each
    Gray Nylon
    3Straight0.13" to 0.2" (2), 0.13" to 0.25" (1)M25
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    0000000000000
    4Straight0.13" to 0.2"M25
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    4Straight0.2" to 0.37"M32
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    4Straight0.13" to 0.26" (3), 0.28" to 0.49" (1)M32
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    7Straight0.13" to 0.25"M32
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    8Straight0.13" to 0.25" (4), 0.2" to 0.4" (4)M40
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    8Straight0.2" to 0.4" (5), 0.28" to 0.49" (3)M50
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    9Straight0.13" to 0.25" (1), 0.2" to 0.4" (3), 0.35" to 0.64" (4), 0.63" to 0.87" (1)M63
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    10Straight0.13" to 0.26" (7), 0.2" to 0.4" (2), 0.63" to 0.87" (1)M50
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    12Straight0.13" to 0.25" (4), 0.2" to 0.4" (8)M50
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    13Straight0.13" to 0.25" (4), 0.2" to 0.4" (4), 0.35" to 0.64" (5)M63
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    14Straight0.2" to 0.4"M63
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    19Straight0.13" to 0.26"M50
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    35Straight0.13" to 0.25"M63
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    78Straight0.06" to 0.1" (76), 0.1" to 0.2" (2)M50
    Metric
    0.32"-40 to 190Nylon Plastic LocknutNEMA 4X, NEMA 12, IP66, IP68
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
     

    Food and Beverage Wraparound Cable Entry Panels

    Image of ProductInUse. Housing with Inserts (Sold Separately). Front orientation. Cable Entry Panels. Food and Beverage Wraparound Cable Entry Panels.

    Housing with Inserts

    (Sold Separately)

    FDA compliant for direct food contact, these cable entry panels have a multi-piece design to wrap around cords in sanitary environments without removing connectors or rewiring. Choose a housing and then select inserts (sold separately).
    Surface-Mount Housings
    Image of Product. Housing Shown Open. Front orientation. Exploded view. Cable Entry Panels. Food and Beverage Wraparound Cable Entry Panels, Surface Mount.
    Image of Product. Housing for 6 Inserts. Front orientation. Cable Entry Panels. Food and Beverage Wraparound Cable Entry Panels, Surface Mount, Stainless Steel and Blue TPE, For 6 Inserts.
    Image of Product. Housing for 8 Inserts. Front orientation. Cable Entry Panels. Food and Beverage Wraparound Cable Entry Panels, Surface Mount, Stainless Steel and Blue TPE, For 8 Inserts.
    Image of Product. Housing for 12 Inserts. Front orientation. Cable Entry Panels. Food and Beverage Wraparound Cable Entry Panels, Surface Mount, Stainless Steel and Blue TPE, For 12 Inserts.

    Housing Shown Open

    Housing for 6 Inserts

    Housing for 8

    Inserts

    Housing for 12

    Inserts

    Stainless Steel—Made of stainless steel, housings resist chemicals and corrosion.
    IP66 Enclosure Rating—They’re rated IP66 as protective against dust and washdowns.
    For
    Insert
    For Panel
    Cutout
    Mounting
    Holes
    For No.
    of Inserts
    Shape
    Dia.
    Relative
    Size
    Lg.
    Wd.
    Dp.
    Lg.
    Wd.
    Mounting Fasteners
    Included
    No.
    of
    Dia.
    Temp. Range,
    ° F
    Enclosure
    Rating
    Food Industry Std.
    Each
    Stainless Steel and Blue TPE
    6Straight0.67"Small5.83"1.5"0.56"4.4"0.7"No40.22"-40 to 175NEMA 4X, IP66
    FDA Compliant 21 CFR 177.2600
    000000000000000
    8Straight0.67"Small4.77"2.29"0.56"3.4"1.4"No40.22"-40 to 175NEMA 4X, IP66
    FDA Compliant 21 CFR 177.2600
    00000000000000
    12Straight0.67"Small5.83"2.29"0.56"4.4"1.4"No40.22"-40 to 175NEMA 4X, IP66
    FDA Compliant 21 CFR 177.2600
    00000000000000
     
    Inserts
    Image of Product. Insert for 0 Cords. Front orientation. Cable Entry Panels. Food and Beverage Wraparound Cable Entry Panels, Inserts, Blue TPE, For 0 Total Cords.
    Image of Product. Insert for 1 Cord. Front orientation. Cable Entry Panels. Food and Beverage Wraparound Cable Entry Panels, Inserts, Blue TPE, For 1 Total Cord.

    Insert for 0 Cords

    Insert for 1 Cord

    TPE Rubber—Inserts are made of TPE, which combines the flexibility and resilience of rubber and plastic, so they’ll maintain their shape when wrapped around your cords.
    For 0 Total Cords—Use inserts for 0 cords to block off unused openings in the housing.
    For 1 Total Cord—Inserts for 1 cord have a slit that eliminates the need to thread cable through them.
    IP66 Enclosure Rating—They’re rated IP66 as protective against dust and washdowns.
    For Total
    No. of Cords
    Shape
    For Cord OD (No.
    of Cords)
    Dia.
    Dp.
    Temp. Range,
    ° F
    Enclosure
    Rating
    Food Industry Std.
    Each
    Blue TPE
     
    Small Insert
    0Straight0.67"1.11"-40 to 175NEMA 4X, IP66
    FDA Compliant 21 CFR 177.2600
    0000000000000
    1Straight0.08" to 0.11"0.67"1.11"-40 to 175NEMA 4X, IP66
    FDA Compliant 21 CFR 177.2600
    000000000000
    1Straight0.12" to 0.15"0.67"1.11"-40 to 175NEMA 4X, IP66
    FDA Compliant 21 CFR 177.2600
    000000000000
    1Straight0.16" to 0.19"0.67"1.11"-40 to 175NEMA 4X, IP66
    FDA Compliant 21 CFR 177.2600
    000000000000
    1Straight0.2" to 0.23"0.67"1.11"-40 to 175NEMA 4X, IP66
    FDA Compliant 21 CFR 177.2600
    000000000000
    1Straight0.24" to 0.27"0.67"1.11"-40 to 175NEMA 4X, IP66
    FDA Compliant 21 CFR 177.2600
    000000000000
    1Straight0.28" to 0.31"0.67"1.11"-40 to 175NEMA 4X, IP66
    FDA Compliant 21 CFR 177.2600
    000000000000
    1Straight0.32" to 0.35"0.67"1.11"-40 to 175NEMA 4X, IP66
    FDA Compliant 21 CFR 177.2600
    000000000000
    1Straight0.36" to 0.39"0.67"1.11"-40 to 175NEMA 4X, IP66
    FDA Compliant 21 CFR 177.2600
    000000000000
    1Straight0.4" to 0.43"0.67"1.11"-40 to 175NEMA 4X, IP66
    FDA Compliant 21 CFR 177.2600
    000000000000
    1Straight0.44" to 0.47"0.67"1.11"-40 to 175NEMA 4X, IP66
    FDA Compliant 21 CFR 177.2600
    000000000000
     

    Low-Profile Wet-Location Break-Through Cable Entry Panels

    The face of these panels is flush with the cable-entry point for a seamless appearance. They have a thin, flexible seal that covers the holes until you push a cord through. This design allows installation of additional cables without changing panels.
    Surface Mount
    Image of Product. For 13 Cords. Front orientation. Cable Entry Panels. Low-Profile Wet-Location Break-Through Cable Entry Panels, Surface Mount, Gray Nylon, For 13 Total Cords.
    Image of Product. For 17 Cords. Front orientation. Cable Entry Panels. Low-Profile Wet-Location Break-Through Cable Entry Panels, Surface Mount, Gray Nylon, For 17 Total Cords.
    Image of Product. For 25 Cords. Front orientation. Cable Entry Panels. Low-Profile Wet-Location Break-Through Cable Entry Panels, Surface Mount, Gray Nylon, For 25 Total Cords.

    For 13

    Cords

    For 17

    Cords

    For 25

    Cords

    NEMA 12 Enclosure Rating and IP66 Enclosure Rating—They are rated NEMA 12 and IP66 to provide protection from dust, water jets, and splashing oil and coolant.
    For Panel
    Cutout
    Mounting
    Holes
    For Total
    No. of Cords
    Shape
    For Cord OD (No. of Cords)
    Lg.
    Wd.
    Mounting Fasteners
    Included
    No.
    of
    Dia.
    Temp. Range,
    ° F
    Enclosure
    Rating
    Certification
    Each
    Gray Nylon
    13Straight0.13" to 0.26" (8), 0.2" to 0.4" (4), 0.63" to 0.87" (1)1.8"1.8"No40.22"-40 to 190NEMA 12, IP66
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    0000000000000
    17Straight0.13" to 0.26" (10), 0.2" to 0.4" (4), 0.29" to 0.47" (2), 0.35" to 0.64" (1)1.8"1.8"No40.22"-40 to 190NEMA 12, IP66
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
    25Straight0.13" to 0.26"1.8"1.8"No40.22"-40 to 190NEMA 12, IP66
    UL Recognized Component, C-UL Recognized Component, DNV-GL Type Approved
    000000000000
     

    Round Wet-Location Multi-Diameter Cable Entry Panels

    Modify these cable entry panels to get the right fit for your cord even when you don't know your exact cord diameter. They have a frame with a two-piece rubber insert that fits around cables with connectors. The insert is made of layers that you peel away until you reach the size that fits your cord.
    Replacement inserts allow you to change cord sizes and configurations.
    Knockout Mount
    Image of Product. For 4 Cords. Front orientation. Cable Entry Panels. Round Wet-Location Multi-Diameter Cable Entry Panels, Knockout Mount, For 4 Total Cords.
    Image of Product. For 9 Cords. Front orientation. Cable Entry Panels. Round Wet-Location Multi-Diameter Cable Entry Panels, Knockout Mount, For 9 Total Cords.

    For 4 Cords

    For 9 Cords

    Stainless Steel—Stainless steel is more corrosion-resistant than brass.
    NEMA 4X Enclosure Rating, NEMA 13 Enclosure Rating, IP66 Enclosure Rating, and IP67 Enclosure Rating—Panels are rated NEMA 4X and NEMA 13 for indoor and outdoor protection against corrosion, water projected from a hose, and oil/coolant spraying, and IP66 and IP67 for protection from washdowns and temporary water submersion.
    For Total
    No. of Cords
    Shape
    For Cord OD (No.
    of Cords)
    For Knockout
    Trade Size
    Thread
    Type
    For Max.
    Panel Thk.
    Temp. Range,
    ° F
    Features
    Enclosure Rating
    Certification
    Each
    Stainless Steel
    4Straight0.14" to 0.65"M63
    Metric
    0.16"-40 to 140Stainless Steel Locknut, Two-Piece Blue Rubber InsertsNEMA 4X, NEMA 13, IP66, IP67
    UL Listed
    0000000000000
    9Straight0.14" to 0.41"M63
    Metric
    0.16"-40 to 140Stainless Steel Locknut, Two-Piece Blue Rubber InsertsNEMA 4X, NEMA 13, IP66, IP67
    UL Listed
    000000000000
     
    Nickel-Plated Brass
    4Straight0.14" to 0.65"M63
    Metric
    0.16"-40 to 140Nickel-Plated Brass Locknut, Two-Piece Blue Rubber InsertsNEMA 4X, NEMA 13, IP66, IP67
    UL Listed
    000000000000
    9Straight0.14" to 0.41"M63
    Metric
    0.16"-40 to 140Nickel-Plated Brass Locknut, Two-Piece Blue Rubber InsertsNEMA 4X, NEMA 13, IP66, IP67
    UL Listed
    000000000000
     
    Replacement Inserts

    Brass Multi-Diameter Wet-Location Cable Entry Panels

    Modify these cable entry panels to get the right fit for your cord even when you don't know your exact cord diameter. They have a frame with a two-piece rubber insert that fits around cables with connectors. The insert is made of layers that you peel away until you reach the size that fits your cord.
    Replacement inserts allow you to change cord sizes and configurations.
    Knockout Mount
    Image of Product. Front orientation. Cable Entry Panels. Brass Multi-Diameter Wet-Location Cable Entry Panels.
    Nickel-Plated Brass—The frame is nickel-plated brass for corrosion resistance.
    NEMA 4X Enclosure Rating, NEMA 13 Enclosure Rating, IP66 Enclosure Rating, and IP67 Enclosure Rating—Panels are rated IP66, IP67, NEMA 4X, and NEMA 13.
    Shape
    For Cord OD (No.
    of Cords)
    For Knockout
    Trade Size
    Thread
    Type
    For Max.
    Panel Thk.
    Temp. Range,
    ° F
    Features
    Enclosure Rating
    Certification
    Each
    Nickel-Plated Brass
    Straight0.37" to 1.28"M63
    Metric
    0.16"-40 to 140Nickel-Plated Brass Locknut, Two-Piece Blue Rubber InsertsNEMA 4X, NEMA 13, IP66, IP67
    UL Listed
    0000000000000
     
    Replacement Inserts

    Stainless Steel Multi-Diameter Wet-Location Cable Entry Panels

    Modify these cable entry panels to get the right fit for your cord even when you don't know the exact diameter. They have a corrosion-resistant frame with a two-piece rubber insert that fits around cables with connectors. The insert is made of layers that you peel away until you reach the size that fits your cord.
    Knockout Mount
    Image of Product. Front orientation. Cable Entry Panels. Stainless Steel Multi-Diameter Wet-Location Cable Entry Panels.
    NEMA 4X Enclosure Rating, NEMA 13 Enclosure Rating, and IP67 Enclosure Rating—Panels are rated NEMA 4X and NEMA 13 for indoor and outdoor protection against corrosion, water projected from a hose, and oil/coolant spraying, and IP67 for temporary water submersion.
    Shape
    For Cord OD (No.
    of Cords)
    For Knockout
    Trade Size
    Thread
    Type
    For Max.
    Panel Thk.
    Temp. Range,
    ° F
    Features
    Enclosure Rating
    Certification
    Each
    Stainless Steel
    Straight0.37" to 1.28"M63
    Metric
    0.16"-40 to 140Stainless Steel Locknut, Two-Piece Blue Rubber InsertsNEMA 4X, NEMA 13, IP67
    UL Listed
    0000000000000
     
    Replacement Inserts
    back to top