Shielding Shielding |
---|
![]() | Unshielded |
![]() | Shielded |
Wire Type Wire Type |
---|
![]() | |
Cable AWG Cable AWG | Show |
---|
Cable AWG Cable AWG | Hide |
---|
Flexibility Flexibility |
---|
![]() |
Continuous Flex |
![]() |
Flexible |
System of Measurement System of Measurement |
---|
|
Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Shield Type Shield Type |
---|
![]() | Braid |
Width Width |
---|
|
Thickness Thickness |
---|
|
Wire Finish Wire Finish |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Wire Material Wire Material |
---|
|
About Wire and Cable
More
Miniature Cable


- Use For: Automation, Interference Shielding, Continuous Motion
- Continuous Flex
- Temperature Range: -40° to 220° F
- Insulation: PVC Plastic
Often used in computers, small electronics, and electronic prototyping, this cable is very flexible with small gauge wire to handle tight curves in narrow spaces. It withstands continuous motion, so it’s also commonly used around heavy vibration and in automated tasks, including robotics. A braid shield blocks interference from nearby equipment.
High-Voltage Continuous-Flex Flat Cable


- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
Rated to 17,000 volts AC or higher, this cable is often used in oil drilling, robotics, and festoon systems. It withstands continuous motion without degrading data or signal transmission. With a flat shape, it’s good for tight spaces. It meets UL 94 V-0 for flame retardance.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | ||||||||||||||
12,000V DC/17,000V AC | ||||||||||||||
28 | 4 | 28/4 | 5 A @ 86° F | 0.23" | 0.08" | 0.8" | Clear | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 00000 | 00000 |
Telephone Cable

- Use For: Telephones
- Flexible