McMaster-Carr logo
    Filter by
    American Wire Gauge (AWG)
    Industrial Info Compare
    Attribute Image
    Number of Wires
    Attribute Image
    Wire Construction
    Industrial Info Compare
    System of Measurement
    Wire Material
    Shielding
    Industrial Info Snippet
    Outer Jacket Material
    Industrial Info Compare
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    133 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Lead Wire

    Also known as hook-up wire, this wire is primarily used for wiring electrical panels, lighting, and plant floor equipment. It meets UL 1007, UL 1015, or UL 1569 for appliance wiring.
    Stranded Wire—300V AC
    Image of Product. Front orientation. Stranded Wire. Lead Wire.
    Stranded wire is flexible, so it’s pliable enough to be pulled around corners. The strand count is the number of strands followed by the size of the individual strand. The higher the number of strands, the more flexible the wire.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Certification
    Flammability
    Rating
    AWM Style
    Outer Jacket
    Color
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    500 ft.
    Long
    28
    7/36
    4 amp @ 86° F0.05"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Brown8054T310000000000000000000000000000
    26
    7/34
    5 amp @ 86° F0.05"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Brown8054T1100000000000000000000000
    24
    7/32
    7 amp @ 86° F0.06"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Brown8054T1200000000000000000000000
    22
    7/30
    10 amp @ 86° F0.06"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Brown8054T1300000000000000000000000
    20
    10/30
    13 amp @ 86° F0.07"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Brown8054T1400000000000000000000000
    18
    16/30
    18 amp @ 86° F0.08"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Brown8054T15000000000000000000000000
    16
    26/30
    24 amp @ 86° F0.09"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Brown8054T160000000000000000000000000
    14
    41/30
    33 amp @ 86° F0.11"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Brown8054T1700000000000000000000000000
    12
    65/30
    45 amp @ 86° F0.12"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Brown8054T18000000000000000000000000000
    10
    105/30
    58 amp @ 86° F0.16"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Brown8054T190000000000000000000000000000
    Stranded Wire—600V AC
    Image of Product. Front orientation. Stranded Wire. Lead Wire.
    Stranded wire is flexible, so it’s pliable enough to be pulled around corners. The strand count is the number of strands followed by the size of the individual strand. The higher the number of strands, the more flexible the wire.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Certification
    Flammability
    Rating
    AWM
    Style
    Outer Jacket
    Color
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    500 ft.
    Long
    26
    7/34
    5 amp @ 86° F0.08"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Brown8054T210000000000000000000000000000
    24
    7/32
    7 amp @ 86° F0.09"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Brown8054T2200000000000000000000000
    22
    7/30
    10 amp @ 86° F0.09"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Brown8054T2300000000000000000000000
    20
    10/30
    13 amp @ 86° F0.1"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Brown8054T2400000000000000000000000
    18
    16/30
    18 amp @ 86° F0.11"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Brown8054T25000000000000000000000000
    16
    26/30
    24 amp @ 86° F0.12"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Brown8054T260000000000000000000000000
    14
    41/30
    33 amp @ 86° F0.14"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Brown8054T2700000000000000000000000000
    12
    65/30
    45 amp @ 86° F0.16"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Brown8054T28000000000000000000000000000
    10
    105/30
    58 amp @ 86° F0.18"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Brown8054T290000000000000000000000000000
    Solid Wire—300V AC
    Image of Product. Front orientation. Solid Wire. Lead Wire.
    Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    AWG
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Certification
    Flammability
    Rating
    AWM Style
    Outer Jacket
    Color
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    250 ft.
    Long
    500 ft.
    Long
    26
    5 amp @ 86° F0.05"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1007, 1569Brown8251T9000000000000000000000000000
    24
    7 amp @ 86° F0.05"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Brown8251T100000000000000000000000
    22
    10 amp @ 86° F0.06"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Brown8251T200000000000000000000000
    20
    13 amp @ 86° F0.06"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Brown8251T300000000000000000000000
    18
    18 amp @ 86° F0.07"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 1569Brown8251T4000000000000000000000000
    16
    24 amp @ 86° F0.1"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1007, 1569Brown8251T800000000000000000000000000
    14
    33 amp @ 86° F0.11"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1569Brown8251T700000000000000000000000000
    12
    45 amp @ 86° F0.13"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1569Brown8251T6000000000000000000000000000
    10
    58 amp @ 86° F0.16"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1569Brown8251T50000000000000000000000000000
    Solid Wire—600V AC
    Image of Product. Front orientation. Solid Wire. Lead Wire.
    Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    AWG
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Certification
    Flammability
    Rating
    AWM
    Style
    Outer Jacket
    Color
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    250 ft.
    Long
    500 ft.
    Long
    24
    7 amp @ 86° F0.08"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Brown8428T10000000000000000000000000000
    22
    10 amp @ 86° F0.09"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Brown8428T200000000000000000000000
    20
    13 amp @ 86° F0.1"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Brown8428T3000000000000000000000000
    18
    18 amp @ 86° F0.1"-40 to 220PVCCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015Brown8428T4000000000000000000000000
    16
    24 amp @ 86° F0.12"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1015Brown8428T8000000000000000000000000000
    14
    33 amp @ 86° F0.13"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1015Brown8428T7000000000000000000000000000
    12
    45 amp @ 86° F0.16"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1015Brown8428T6000000000000000000000000000
    10
    58 amp @ 86° F0.18"-40 to 220PVCUL Recognized Component
    UL 2556 VW-1
    1015Brown8428T50000000000000000000000000000

    Building Wire

    Install this copper wire in conduit and cable trays in commercial and industrial buildings. It's also known as branch circuit wire. The outer jacket is designed to be installed without applying pulling lubricant.
    Stranded Wire with Nylon Outer Jacket and PVC Inner Insulation
    Image of Product. TFFN, THHN/THWN, and THHN/THWN-2 Stranded. Front orientation. Building Wire. Building Wire, Nylon Outer Jacket, Stranded Wire.

    TFFN, THHN/THWN, and THHN/THWN-2

    Stranded

    Stranded wire is flexible, so it’s pliable enough to be pulled around corners.
    Wire with a nylon outer jacket resists oil and water.
    TFFN Cable—TFFN wire is also known as fixture wire. It’s for use in dry locations.
    THHN Cable—THHN wire can be used in dry or damp locations where wire is exposed to condensation or moisture, such as a basement.
    THWN Cable and THWN-2 Cable—THWN and THWN-2 wire can be used in both wet and dry environments.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    Shorter Lengths
    Longer Lengths
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    Flammability
    Rating
    Outer Jacket
    Color
    Choose a Length, ft.
    Per
    Ft.
    Lg.,
    ft.
    Each
    600V AC/600V DC
    18
    16/30
    6 amp @ 86° F0.09"-10 to 190TFFN
    UL Listed
    Brown50, 100, 2507715T11000005007715T51000000
    16
    26/30
    8 amp @ 86° F0.1"-10 to 190TFFN
    UL Listed
    Brown50, 100, 2507715T1200005007715T5200000
    14
    19/27
    15 amp @ 86° F0.11"-10 to 190THHN, THWN
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Brown25, 50, 100, 2507715T1300005007715T5300000
    12
    19/25
    20 amp @ 86° F0.13"-10 to 190THHN, THWN
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Brown25, 50, 100, 2507715T1400005007715T54000000
    10
    19/23
    30 amp @ 86° F0.16"-10 to 190THHN, THWN
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Brown10, 25, 50, 100, 2507715T1500005007715T55000000
    8
    19/21
    55 amp @ 86° F0.21"-10 to 190THHN, THWN-2
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Brown10, 25, 50, 100, 2507715T1600005007715T56000000
    6
    19/19
    75 amp @ 86° F0.25"-10 to 190THHN, THWN-2
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Brown10, 25, 50, 100, 2507715T1700005007715T57000000
    4
    19/17
    95 amp @ 86° F0.32"-10 to 190THHN, THWN-2
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Brown10, 25, 50, 100, 2507715T1800005007715T58000000
    3
    19/16
    110 amp @ 86° F0.35"-10 to 190THHN, THWN-2
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Brown10, 25, 50, 100, 2507715T1900005007715T5900000000
    2
    19/15
    130 amp @ 86° F0.38"-10 to 190THHN, THWN-2
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Brown10, 25, 50, 100, 2507715T2100005007715T6100000000
    1/0
    19/13
    170 amp @ 86° F0.47"-10 to 190THHN, THWN-2
    UL Listed
    Brown10, 25, 50, 100, 2507715T2200005007715T6200000000
    2/0
    19/12
    195 amp @ 86° F0.52"-10 to 190THHN, THWN-2
    UL Listed
    Brown10, 25, 50, 100, 2507715T2300005007715T6300000000
     
    Solid Wire with Nylon Outer Jacket and PVC Inner Insulation
    Image of Product. THHN/THWN Solid Wire. Front orientation. Building Wire. Building Wire, Nylon Outer Jacket, Solid Wire.

    THHN/THWN Solid Wire

    Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
    Wire with a nylon outer jacket resists oil and water.
    THHN Cable—THHN wire can be used in dry or damp locations where wire is exposed to condensation or moisture, such as a basement.
    THWN Cable—THWN and THWN-2 wire can be used in both wet and dry environments.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    Shorter Lengths
    Longer Lengths
    AWG
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    Flammability
    Rating
    Outer Jacket
    Color
    Choose a Length, ft.
    Per
    Ft.
    Lg.,
    ft.
    Each
    600V AC/600V DC
    14
    15 amp @ 86° F0.1"-10 to 190THHN, THWN
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Brown25, 50, 100, 2507715T31000005007715T71000000
    12
    20 amp @ 86° F0.12"-10 to 190THHN, THWN
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Brown25, 50, 100, 2507715T3200005007715T72000000
    10
    30 amp @ 86° F0.15"-10 to 190THHN, THWN
    C-UL Listed, UL Listed
    UL 2556 VW-1
    Brown25, 50, 100, 2507715T3300005007715T73000000
     

    Thermostat Cable

    Image of Product. Front orientation. Thermostat Cable.
    Hook up thermostats, air-conditioning units, and other low-voltage equipment. This cable is designated CL2 so it has flame-resistant insulation. The wires are solid so it stays in the shape you bend it.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    Solid Wire
     
    150V AC/150V DC
    20
    220/2
    0.11"PVC
    BrownPolyethyleneRed, White0 to 140CL2
    ETL Listed
    8278T1100000000000000000000000000000
    20
    320/3
    0.12"PVC
    BrownPolyethyleneGreen, Red, White0 to 140CL2
    ETL Listed
    8278T120000000000000000000
    20
    420/4
    0.13"PVC
    BrownPolyethyleneBlue, Green, Red, White0 to 140CL2
    ETL Listed
    8278T130000000000000000000000000
    20
    520/5
    0.15"PVC
    BrownPolyethyleneBlue, Green, Red, White, Yellow0 to 140CL2
    ETL Listed
    8278T140000000000000000000000000
    20
    620/6
    0.16"PVC
    BrownPolyethyleneBlue, Brown, Green, Red, White, Yellow0 to 140CL2
    ETL Listed
    8278T1500000000000000000000000000
    20
    820/8
    0.17"PVC
    BrownPolyethyleneBlack, Blue, Brown, Green, Orange, Red, White, Yellow0 to 140CL2
    ETL Listed
    8278T1600000000000000000000000000
    18
    218/2
    0.13"PVC
    BrownPolyethyleneRed, White0 to 140CL2
    ETL Listed
    8278T21000000000000000000000000
    18
    318/3
    0.14"PVC
    BrownPolyethyleneGreen, Red, White0 to 140CL2
    ETL Listed
    8278T22000000000000000000000000
    18
    418/4
    0.15"PVC
    BrownPolyethyleneBlue, Green, Red, White0 to 140CL2
    ETL Listed
    8278T2300000000000000000000000000
    18
    518/5
    0.17"PVC
    BrownPolyethyleneBlue, Green, Red, White, Yellow0 to 140CL2
    ETL Listed
    8278T2400000000000000000000000000
    18
    618/6
    0.19"PVC
    BrownPolyethyleneBlue, Brown, Green, Red, White, Yellow0 to 140CL2
    ETL Listed
    8278T2500000000000000000000000000
    18
    818/8
    0.2"PVC
    BrownPolyethyleneBlack, Blue, Brown, Green, Orange, Red, White, Yellow0 to 140CL2
    ETL Listed
    8278T2600000000000000000000000000
     

    Machine Tool Wire

    More flexible than standard wire, this wire is often used for internal appliance wiring. The strand count is the number of strands followed by the size of the individual strand. The higher the number of strands, the more flexible the wire. Also known as MTW wire, it’s rated UL 1063 for machine tool wiring.
    600V AC
    Image of Product. Front orientation. Lead Wire. Machine Tool Wire.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Flexibility
    Cable
    Designation
    Specs.
    Met
    Certification
    Flammability
    Rating
    Outer Jacket
    Color
    Choose a Length, ft.
    Per
    Ft.
    Stranded Wire
    18
    16/30
    19 amp @ 86° F0.11"0 to 190PVCFlexibleMTW
    UL 1063CSA Certified, UL Listed
    UL 2556 VW-1
    Brown25, 50, 100, 2509874T1100000
    16
    26/30
    24 amp @ 86° F0.12"0 to 190PVCFlexibleMTW
    UL 1063CSA Certified, UL Listed
    UL 2556 VW-1
    Brown25, 50, 100, 2509874T120000
    14
    41/30
    33 amp @ 86° F0.14"0 to 190PVCFlexibleMTW
    UL 1063CSA Certified, UL Listed
    UL 2556 VW-1
    Brown25, 50, 100, 2509874T130000
    12
    65/30
    43 amp @ 86° F0.16"0 to 190PVCFlexibleMTW
    UL 1063CSA Certified, UL Listed
    UL 2556 VW-1
    Brown25, 50, 100, 2509874T140000
    10
    105/30
    59 amp @ 86° F0.18"0 to 190PVCFlexibleMTW
    UL 1063CSA Certified, UL Listed
    UL 2556 VW-1
    Brown10, 25, 50, 100, 2509874T150000
     
    600V AC
    Image of Product. Front orientation. Lead Wire. Machine Tool Wire.
    UL 2556 VW-1—Flame rated VW-1 wire meets requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Flexibility
    Cable
    Designation
    Specs.
    Met
    Certification
    Flammability
    Rating
    Lg.,
    ft.
    Outer Jacket
    Color
    Each
    Stranded Wire
    18
    16/30
    19 amp @ 86° F0.11"0 to 190PVCFlexibleMTW
    UL 1063CSA Certified, UL Listed
    UL 2556 VW-1
    500Brown9874T21000000
    16
    26/30
    24 amp @ 86° F0.12"0 to 190PVCFlexibleMTW
    UL 1063CSA Certified, UL Listed
    UL 2556 VW-1
    500Brown9874T2200000
    14
    41/30
    33 amp @ 86° F0.14"0 to 190PVCFlexibleMTW
    UL 1063CSA Certified, UL Listed
    UL 2556 VW-1
    500Brown9874T23000000
    12
    65/30
    43 amp @ 86° F0.16"0 to 190PVCFlexibleMTW
    UL 1063CSA Certified, UL Listed
    UL 2556 VW-1
    500Brown9874T24000000
    10
    105/30
    59 amp @ 86° F0.18"0 to 190PVCFlexibleMTW
    UL 1063CSA Certified, UL Listed
    UL 2556 VW-1
    500Brown9874T25000000
     

    Ribbon Cable

    Image of Product. Front orientation. Ribbon Cable.
    Often used in electronic prototyping or in the interior of computers, this flat cable is ultra flexible with small-gauge wires so it fits in tight spaces. Unlike standard flat control cable, the wires are bonded together without an overall insulation, so they can be easily separated for installation.
    UL 2556 VW-1— Cable is flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    Outer
    Jacket
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    Wd.
    Thk.
    Material
    Color
    Temp. Range,
    ° F
    Certification
    Flammability
    Rating
    10 ft.
    Long
    25 ft.
    Long
    Stranded Wire
     
    150V AC
    26
    1026/10
    1 amp @ 86° F0.39"0.04"PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow0 to 175UL Recognized Component
    UL 2556 VW-1
    2674N210000000000000
    26
    1526/15
    1 amp @ 86° F0.59"0.04"PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow0 to 175UL Recognized Component
    UL 2556 VW-1
    2674N2200000000000
    24
    1024/10
    2.1 amp @ 86° F0.44"0.04"PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow0 to 175UL Recognized Component
    UL 2556 VW-1
    2674N23000000000000
    24
    1524/15
    2.1 amp @ 86° F0.66"0.04"PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow0 to 175UL Recognized Component
    UL 2556 VW-1
    2674N24000000000000
    22
    1022/10
    3.1 amp @ 86° F0.51"0.05"PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow0 to 175UL Recognized Component
    UL 2556 VW-1
    2674N25000000000000
    22
    1522/15
    3.1 amp @ 86° F0.77"0.05"PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow0 to 175UL Recognized Component
    UL 2556 VW-1
    2674N26000000000000
     

    Light Duty Power Cable

    Image of Product. Front orientation. Power Cable. Light Duty Power Cable.
    This cable is best for light fixtures, portable heaters, and other small appliances. Also known as zip cord, its wires separate with a quick tug for hassle-free installation. Plus, with a flat shape, it runs neatly along walls and baseboards.
    Cable
    AWG
    Current @
    Temp.
    Outer Jacket
    Material
    Temp.,
    ° F
    Certification
    Outer Jacket
    Color
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    300V AC/300V DC
     
    SPT-1 Cable
    18/2
    10 amp @ 86° FPVC
    0 to 140CSA Certified, UL Listed
    Brown7870T21000000000000000000
     

    Mil. Spec. Lead Wire

    Image of Product. Front orientation. Lead Wire. Mil. Spec. Lead Wire.
    This wire meets stringent military specifications for material quality. It’s also known as hook-up wire.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Certification
    Mil. Spec.
    Outer Jacket
    Color
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    200 ft.
    Long
    500 ft.
    Long
    Stranded Wire
     
    1,000V AC
    24
    7/32
    6 amp @ 86° F0.06"-40 to 220PVCMil. Spec.
    MIL-DTL-16878/2 Type C, MIL-W-76 Type MWBrown6981T1000000000000000000000000000
    22
    7/30
    8 amp @ 86° F0.06"-40 to 220PVCMil. Spec.
    MIL-DTL-16878/2 Type C, MIL-W-76 Type MWBrown6981T200000000000000000000000
    20
    10/30
    10 amp @ 86° F0.07"-40 to 220PVCMil. Spec.
    MIL-DTL-16878/2 Type C, MIL-W-76 Type MWBrown6981T300000000000000000000000
    18
    16/30
    15 amp @ 86° F0.08"-40 to 220PVCMil. Spec.
    MIL-DTL-16878/2 Type C, MIL-W-76 Type MWBrown6981T4000000000000000000000000
    16
    19/29
    19 amp @ 86° F0.1"-40 to 220PVCMil. Spec.
    MIL-DTL-16878/2 Type C, MIL-W-76 Type MWBrown6981T500000000000000000000000000
    14
    19/27
    27 amp @ 86° F0.11"-40 to 220PVCMil. Spec.
    MIL-DTL-16878/2 Type C, MIL-W-76 Type MWBrown6981T600000000000000000000000000
    12
    19/25
    36 amp @ 86° F0.12"-40 to 220PVCMil. Spec.
    MIL-DTL-16878/2 Type C, MIL-W-76 Type MWBrown6981T7000000000000000000000000000
     
    3,000V AC
    10
    37/26
    58 amp @ 86° F0.18"-40 to 220PVCMil. Spec.
    MIL-DTL-16878/3, MIL-W-76 Type HWBrown6981T80000000000000000000000000000
     

    Lead Wire Assortments

    Image of Product. Eight Spools. Front orientation. 8. Lead Wire Assortments.

    Eight Spools

    Keep spools of wire in multiple colors on hand; each assortment includes one spool of each color listed. Mount the included rack (fasteners not included) or use it to transport wire. Also known as hook-up wire, it’s primarily used for wiring electrical panels, lighting, and plant for equipment. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material. Wire meets UL standards for appliance wiring.
    Stranded Wire—Stranded wire is flexible, so it’s pliable enough to be pulled around corners.
    Solid Wire—Solid wire bends and stays in the position that you bend it. It’s easier to terminate than stranded wire.
    Mount
    Holes
    25 ft. Long
    No. of
    Spools
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Outer Jacket Color
    Certification
    Flammability
    Rating
    AWM Style
    No.
    of
    Dia.
    Each
    Stranded Wire
     
    300V AC
    826
    7/34
    5 amp @ 86° F0.05"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    1007, 156920.19"6616N41000000
    824
    7/32
    7 amp @ 86° F0.06"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    1007, 156920.19"6616N4200000
    822
    7/30
    10 amp @ 86° F0.06"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    1007, 156920.19"6616N4300000
    820
    10/30
    13 amp @ 86° F0.07"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    1007, 156920.19"6616N4400000
    818
    16/30
    18 amp @ 86° F0.08"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    1007, 156920.19"6616N4500000
     
    600V AC
    826
    7/34
    5 amp @ 86° F0.09"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    101520.19"6616N5100000
    824
    7/32
    7 amp @ 86° F0.09"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    101520.19"6616N5200000
    822
    7/30
    10 amp @ 86° F0.09"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowC-UL Listed, CSA Certified, UL Listed
    UL 2556 VW-1
    101520.19"6616N5300000
     
    Solid Wire
     
    300V AC
    824
    7 amp @ 86° F0.05"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"9948T2100000
    822
    10 amp @ 86° F0.06"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"9948T2200000
    820
    13 amp @ 86° F0.06"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"9948T1700000
    818
    18 amp @ 86° F0.07"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1007, 156920.19"9948T1800000
     
    600V AC
    824
    7 amp @ 86° F0.09"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015, 1032, 1230, 133520.19"9948T4800000
    822
    10 amp @ 86° F0.09"-40 to 220PVCBlack, Blue, Brown, Green, Orange, Red, White, YellowCSA Certified, UL Recognized Component
    UL 2556 VW-1
    1015, 1032, 1230, 133520.19"9948T4900000
     

    Mil. Spec. Lead Wire Assortments

    Image of Product. Eight Spools. Front orientation. 8. Mil. Spec. Lead Wire Assortments.

    Eight Spools

    Maintain a supply of Mil. Spec. wire in multiple colors; each assortment includes one spool of each color listed. Mount the included rack (fasteners not included) or use it to transport wire. This wire meets MIL-W-76 Type MW for material quality. It’s also known as hook-up wire.
    Mount
    Holes
    No. of
    Spools
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Outer Jacket
    Material
    Outer Jacket Color
    Lg.,
    ft.
    Mil. Spec.
    No.
    of
    Dia.
    Each
    Stranded Wire
     
    1,000V AC
    820
    10/30
    10 amp @ 86° F0.07"-40 to 175PVCBlack, Blue, Brown, Green, Orange, Red, White, Yellow25MIL-W-76 Type MW20.19"6808K220000000
    818
    16/30
    15 amp @ 86° F0.08"-40 to 175PVCBlack, Blue, Brown, Green, Orange, Red, White, Yellow25MIL-W-76 Type MW20.19"6808K21000000
    816
    19/29
    19 amp @ 86° F0.09"-40 to 175PVCBlack, Blue, Brown, Green, Orange, Red, White, Yellow25MIL-W-76 Type MW20.19"6808K32000000
     

    Circuit Board Cords

    Make connections in circuit boards with these short lengths of terminated wire. Length does not include the machine pins.
    Machine-Pin Terminal Connection—Insert a male machine pin into the holes on a solderless circuit board, or into a female machine pin.
    Outer Jacket Color—Cords with multiple colors are assortments that contains one cord in each color.
    Lg.
    Outer
    Jacket
    AWG
    Wire Strand
    Count
    Pin Dia./For
    Pin Dia.
    Temp. Range,
    ° F
    Inch
    Metric,
    cm
    Material
    Color
    Pkg.
    Qty.
    Pkg.
    Stranded Wire
     
    Image of Product. Front orientation. Circuit Board Cords. Circuit Board Cords, Female Machine-Pin Terminal × Female Machine-Pin Terminal.
    Female Machine-Pin Terminal × Female Machine-Pin Terminal
    24
    11/34
    0.025" × 0.025"-40 to 1751.97"5PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N3900000
    24
    11/34
    0.025" × 0.025"-40 to 1753.94"10PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N410000
    24
    11/34
    0.025" × 0.025"-40 to 1757.87"20PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N420000
    24
    11/34
    0.025" × 0.025"-40 to 17511.81"30PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N430000
     
    Image of Product. Front orientation. Circuit Board Cords. Circuit Board Cords, Male Machine-Pin Terminal × Female Machine-Pin Terminal.
    Male Machine-Pin Terminal × Female Machine-Pin Terminal
    24
    11/34
    0.025" × 0.025"-40 to 1751.97"5PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N350000
    24
    11/34
    0.025" × 0.025"-40 to 1753.94"10PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N360000
    24
    11/34
    0.025" × 0.025"-40 to 1757.87"20PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N370000
    24
    11/34
    0.025" × 0.025"-40 to 17511.81"30PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N380000
     
    Image of Product. Front orientation. Circuit Board Cords. Circuit Board Cords, Male Machine-Pin Terminal × Male Machine-Pin Terminal.
    Male Machine-Pin Terminal × Male Machine-Pin Terminal
    24
    11/34
    0.025" × 0.025"-40 to 1751.97"5PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N310000
    24
    11/34
    0.025" × 0.025"-40 to 1751.97"5PVC
    Brown103104N110000
    24
    11/34
    0.025" × 0.025"-40 to 1753.94"10PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N320000
    24
    11/34
    0.025" × 0.025"-40 to 1757.87"20PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N330000
    24
    11/34
    0.025" × 0.025"-40 to 17511.81"30PVC
    Black, Blue, Brown, Gray, Green, Orange, Purple, Red, White, Yellow103104N340000
     
    back to top