    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Continuous-Flex Power Cable

    Power motors on moving gantries and cranes with this cable that flexes millions of times without breaking. It’s made for constant motion, with finely stranded conductors twisted like a rope to resist wear from bending.
    Shielded—Shielding stops these cables from acting as antennas that emit electromagnetic interference, which could disrupt nearby equipment such as control or data cables.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Clean Room
    Std.
    Choose a Length, ft.
    1-99
    100-Up
    1,000V AC
     
    Image of Product. Side1 orientation. Power Cable. Continuous-Flex Power Cable, Unshielded.
    Unshielded
    10/4
    48 amp @ 86° F4.13"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K150000000000
    8/4
    69 amp @ 86° F5.18"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K170000000000
    8/5
    51 amp @ 86° F5.93"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K180000000000
    6/4
    92 amp @ 86° F6.23"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K190000000000
    6/5
    69 amp @ 86° F7.05"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K210000000000
    4/4
    121 amp @ 86° F7.5"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K220000000000
    2/4
    152 amp @ 86° F8.55"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K230000000000
    1/4
    191 amp @ 86° F10.35"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K240000000000
     
    Image of Product. Side1 orientation. Power Cable. Continuous-Flex Power Cable, Shielded.
    Shielded
    12/5
    27 amp @ 86° F4.43"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K350000000000
    10/4
    48 amp @ 86° F4.73"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K360000000000
    10/5
    36 amp @ 86° F5.33"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K370000000000
    8/4
    69 amp @ 86° F6.08"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K380000000000
    8/5
    51 amp @ 86° F6.68"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K390000000000
    6/4
    92 amp @ 86° F6.98"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K410000000000
    4/4
    121 amp @ 86° F8.4"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K420000000000
    2/4
    152 amp @ 86° F9.6"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K430000000000
    1/4
    191 amp @ 86° F11.1"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K440000000000
    2/0/4
    239 amp @ 86° F12.68"PVC
    Black25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5, 10, 20, 30, 50, 1009243K450000000000
     

    Harsh-Environment Power Cable

    Transmit power in dirty, corrosive environments such as offshore rigs and ships. This cable is strong enough to resist crushing forces from heavy equipment. Its CPE jacket and tin-plated copper conductors maintain power in areas exposed to chemicals, oil, and salt water. It meets UL 1309 for high-performance marine cables, yet works just as well on land.
    Bronze Armor—A layer of bronze armor between the two outer jackets boosts resistance to abrasion, impact, and crushing.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Specs.
    Met
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Image of Product. Front orientation. Power Cable. Harsh-Environment Power Cable, Type P Cable.
    Type P Cable
    16/3
    18 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K160000000000
    16/4
    14 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K2100000000
    14/3
    20 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K1700000000
    14/4
    16 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K2200000000
    12/3
    25 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K1800000000
    12/4
    20 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K2300000000
    10/3
    35 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K1900000000
    10/4
    28 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K2400000000
    8/4
    40 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K2500000000
    6/4
    52 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K260000000000
    4/4
    68 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    5, 10, 25, 508248K270000000000
    2/4
    92 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    5, 10, 25, 508248K280000000000
     
    Image of Product. Front orientation. Power Cable. Harsh-Environment Power Cable, Type P Cable with Bronze Armor.
    Type P Cable with Bronze Armor
    16/3
    18 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K4600000000
    16/4
    14 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K5100000000
    14/3
    20 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K4700000000
    14/4
    16 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K5200000000
    12/3
    25 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K4800000000
    12/4
    20 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K5300000000
    10/3
    35 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K49000000000
    10/4
    28 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K540000000000
    8/4
    40 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K550000000000
    6/4
    52 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    5, 10, 25, 508248K560000000000
    4/4
    68 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    5, 10, 25, 508248K570000000000
    2/4
    92 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    5, 10, 25, 508248K580000000000
     

    Variable-Frequency Drive Motor Cable

    This cable is used in variable-frequency drive motors. It has a layer of braid and foil shielding that provides excellent protection against signal interference caused by voltage fluctuations and current spikes. The industry designation is WTTC, so it can be installed in cable trays or raceway in a wind turbine generator. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray. The insulation resists oil.
    Power Wire— Stranded with PVC Outer Jacket
    Image of Product. Side1 orientation. Variable-Frequency Drive Motor Cable. Power Wire— Stranded with PVC Outer Jacket.
    Image of Product. With Uninsulated Ground Wire. Side1 orientation. Variable-Frequency Drive Motor Cable. Power Wire— Stranded with PVC Outer Jacket, Uninsulated Ground Wire.

    With Uninsulated Ground Wire

    Cable with power wires sends electricity to run a motor.
    Uninsulated Ground Wire—Cable with an uninsulated ground wire has an additional uninsulated ground wire you can use to ground the cable’s foil shielding. Also known as a drain wire, it isn’t counted in the cable’s number of wires.
    MSHA Accepted—MSHA-accepted cable meets Mine Safety and Health Administration (MSHA) standards for material quality.
    Power
    Wire
    Inner
    Insulation
    Per Ft.
    No.
    of
    AWG
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Features
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    Double Shielded—1,000V AC/1,500V DC
    418
    18/4
    7 amp @ 86° F0.39"BlackNylon, PVC
    Black-40 to 220WTTC
    UL Listed, C-UL Listed, MSHA Accepted
    5, 10, 20, 30, 50, 1007777T280000000000
    416
    16/4
    10 amp @ 86° F0.46"BlackNylon, PVC
    Black, Green/Yellow-40 to 220WTTC
    Uninsulated Ground WireUL Listed, C-UL Listed, MSHA Accepted
    5, 10, 20, 30, 50, 1007777T2700000000
    414
    14/4
    15 amp @ 86° F0.52"BlackNylon, PVC
    Black, Green/Yellow-40 to 220WTTC
    UL Listed, C-UL Listed
    5, 10, 20, 30, 50, 1007777T2100000000
    412
    12/4
    20 amp @ 86° F0.58"BlackNylon, PVC
    Black, Green/Yellow-40 to 220WTTC
    UL Listed, C-UL Listed
    5, 10, 20, 30, 50, 1007777T2200000000
    410
    10/4
    30 amp @ 86° F0.7"BlackNylon, PVC
    Black, Green/Yellow-40 to 220WTTC
    UL Listed, C-UL Listed
    5, 10, 20, 30, 50, 1007777T2300000000
    48
    8/4
    40 amp @ 86° F0.84"BlackNylon, PVC
    Black, Green/Yellow-40 to 220WTTC
    UL Listed, C-UL Listed
    5, 10, 20, 30, 50, 1007777T240000000000
    46
    6/4
    55 amp @ 86° F1"BlackNylon, PVC
    Black, Green/Yellow-40 to 220WTTC
    UL Listed, C-UL Listed
    5, 10, 20, 30, 50, 1007777T250000000000
    44
    4/4
    70 amp @ 86° F1.19"BlackNylon, PVC
    Black, Green/Yellow-40 to 220WTTC
    UL Listed, C-UL Listed
    5, 10, 20, 30, 50, 1007777T260000000000
     
    Power Wire— Stranded with Cross-Linked Polyethylene Outer Jacket
    Image of Product. With Three Uninsulated Ground Wires. Side1 orientation. Variable-Frequency Drive Motor Cable. Power Wire— Stranded with Cross-Linked Polyethylene Outer Jacket, Three Uninsulated Ground Wires.

    With Three Uninsulated Ground

    Wires

    Cable with power wires sends electricity to run a motor.
    Three Uninsulated Ground Wires—Cable with three uninsulated ground wires pairs a ground wire with each power wire, so you can create multiple circuits from the same cable. These wires aren’t counted in the cable’s number of wires.
    Power
    Wire
    Inner
    Insulation
    No.
    of
    AWG
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Features
    5 ft.
    Long
    10 ft.
    Long
    20 ft.
    Long
    30 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    Double Shielded—1,000V AC/1,000V DC
    314
    14/3
    25 amp @ 86° F0.5"BlackPolyethyleneBlack, White-40 to 220WTTC
    Three Uninsulated Ground Wires7777T310000000000000000000000000000000000000000
    312
    12/3
    30 amp @ 86° F0.57"BlackPolyethyleneBlack, White-40 to 220WTTC
    Three Uninsulated Ground Wires7777T320000000000000000000000000000000000
     
    Power and Control Wire—Stranded with Polyethylene Outer Jacket
    Image of Product. With Uninsulated Ground Wire. Side1 orientation. Variable-Frequency Drive Motor Cable. Power and Control Wire—Stranded with Polyethylene Outer Jacket, Uninsulated Ground Wire.

    With Uninsulated Ground Wire

    Cable with power and control wires has an individually shielded pair of wires that connect to a brake or temperature sensor, reducing the number of cables used in areas with limited space.
    Uninsulated Ground Wire—Cable with an uninsulated ground wire has an additional uninsulated ground wire you can use to ground the cable’s foil shielding. Also known as a drain wire, it isn’t counted in the cable’s number of wires.
    Power
    Wire
    Control
    Wire
    Inner
    Insulation
    No.
    of
    AWG
    Cable
    AWG
    No.
    of
    AWG
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Features
    5 ft.
    Long
    10 ft.
    Long
    20 ft.
    Long
    30 ft.
    Long
    50 ft.
    Long
    Double Shielded—1,000V AC/1,000V DC
    416
    16/4
    218
    18/2
    18 amp @ 86° F0.57"BlackPolyethyleneBlack, Green/Yellow-40 to 220WTTC
    Uninsulated Ground Wire7777T116000000000000000000000000000000000
    414
    14/4
    218
    18/2
    25 amp @ 86° F0.62"BlackPolyethyleneBlack, Green/Yellow-40 to 220WTTC
    Uninsulated Ground Wire7777T120000000000000000000000000000
    412
    12/4
    218
    18/2
    30 amp @ 86° F0.65"BlackPolyethyleneBlack, Green/Yellow-40 to 220WTTC
    Uninsulated Ground Wire7777T1400000000000000000000000000000
     

    Servomotor Continuous-Flex Cable

    Connect servocontrollers and servomotors in automated equipment and on assembly lines. This cable withstands continuous motion without degrading data or signal transmission. The polyurethane rubber insulation resists abrasion and oil. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    Power Wire—Stranded
    Image of Product. Front orientation. Servo Cable. Servomotor Continuous-Flex Cable, Double Shielded.
    Image of Attribute. Front orientation. Contains Annotated. Servomotor Continuous-Flex Cable.

    Double Shielded

    Cable with power wires sends electricity to run a servomotor.
    Double Shielded—Double shielded cable has a layer of braid and foil shielding for better protection against signal interference than braid alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors.
    Bend Radius—Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
    Per Ft.
    No. of
    Wires
    AWG
    Cable
    AWG
    Current @
    Temp.
    OD
    Bend
    Radius
    Outer Jacket
    Material
    Outer Jacket
    Color
    Inner Insulation
    Material
    Inner Insulation
    Color
    Temp. Range,
    ° F
    Certification
    Flammability
    Rating
    Choose a Length, ft.
    1-49
    50-Up
    Double Shielded—1,000V AC
    414
    14/4
    15 amp @ 86° F0.42"3.15"Polyurethane Rubber
    OrangePolypropylene
    Black, Green/Yellow-40 to 175UL Recognized Component, CSA Certified
    UL 2556 VW-1
    5, 10, 20, 30, 508815T110000000000
    412
    12/4
    20 amp @ 86° F0.47"3.53"Polyurethane Rubber
    OrangePolypropylene
    Black, Green/Yellow-40 to 175UL Recognized Component, CSA Certified
    UL 2556 VW-1
    5, 10, 20, 30, 508815T130000000000
    410
    10/4
    30 amp @ 86° F0.57"4.28"Polyurethane Rubber
    OrangePolypropylene
    Black, Green/Yellow-40 to 175UL Recognized Component, CSA Certified
    UL 2556 VW-1
    5, 10, 20, 30, 508815T140000000000
     
    Control Wire—Stranded
    Image of Product. Front orientation. Servo Cable. Servomotor Continuous-Flex Cable, Shielded.
    Image of Attribute. Front orientation. Contains Annotated. Servomotor Continuous-Flex Cable.

    Shielded

    Cable with control wires is also known as feedback cable. It sends and receives signals between a servomotor and a PLC.
    Shielded—Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
    Bend Radius—Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
    No. of
    Wires
    AWG
    Cable
    AWG
    Current @
    Temp.
    OD
    Bend
    Radius
    Outer Jacket
    Material
    Outer Jacket
    Color
    Inner Insulation
    Material
    Inner Insulation Color
    Temp. Range,
    ° F
    Certification
    Flammability
    Rating
    5 ft.
    Long
    10 ft.
    Long
    20 ft.
    Long
    30 ft.
    Long
    50 ft.
    Long
    Shielded—30V AC/ 45V DC
    826
    26/8
    0.7 amp @ 86° F0.25"2.17"Polyurethane Rubber
    GreenPolypropylene
    Black, Blue, Brown, Green, Orange, Purple, Red, Yellow-40 to 175UL Recognized Component
    UL 2556 VW-1
    8815T21000000000000000000000000000000000
    824
    24/8
    1.4 amp @ 86° F0.29"1.87"Polyurethane Rubber
    GreenPolypropylene
    Blue, Brown, Gray, Green, Pink, Red, White, Yellow-40 to 175UL Recognized Component
    UL 2556 VW-1
    8815T220000000000000000000000000000
     
    Power and Control Wire—Stranded
    Image of Product. Front orientation. Servo Cable. Servomotor Continuous-Flex Cable, Double Shielded.
    Image of Attribute. Front orientation. Contains Annotated. Servomotor Continuous-Flex Cable.

    Double Shielded

    Cable with power and control wires sends data such as positioning information from a servomotor to a controller. It has four power wires and two pairs of control wires.
    Double Shielded—Double shielded cable has a layer of braid and foil shielding for better protection against signal interference than braid alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors.
    Bend Radius—Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
    Power
    Wire
    Control Wire
    Per Ft.
    No. of
    Wires
    No. of
    Wires
    AWG
    Cable
    AWG
    No. of
    Wires
    AWG
    Cable
    AWG
    No. of
    Wires
    AWG
    Cable
    AWG
    Current @
    Temp.
    OD
    Bend
    Radius
    Outer Jacket
    Material
    Outer Jacket
    Color
    Inner Insulation
    Material
    Inner Insulation
    Color
    Temp. Range,
    ° F
    Certification
    Flammability
    Rating
    Choose a Length, ft.
    1-49
    50-Up
    Double Shielded—1,000V AC
    8414
    14/4
    418
    18/4
    15 amp @ 86° F0.57"4.28"Polyurethane Rubber
    OrangePolypropylene
    Black, Green/Yellow-40 to 175UL Recognized Component, CSA Certified
    UL 2556 VW-1
    5, 10, 20, 30, 508815T16000000000000
    8412
    12/4
    218
    18/2
    216
    16/2
    20 amp @ 86° F0.64"4.8"Polyurethane Rubber
    OrangePolypropylene
    Black, Green/Yellow-40 to 175UL Recognized Component, CSA Certified
    UL 2556 VW-1
    5, 10, 20, 30, 508815T170000000000
    8410
    10/4
    218
    18/2
    216
    16/2
    30 amp @ 86° F0.71"5.33"Polyurethane Rubber
    OrangePolypropylene
    Black, Green/Yellow-40 to 175UL Recognized Component, CSA Certified
    UL 2556 VW-1
    5, 10, 20, 30, 508815T180000000000
     

    Heavy Duty Harsh-Environment Power Cable

    Image of Product. Front orientation. Power Cable. Heavy Duty Harsh-Environment Power Cable.
    Delivering up to 2,000 volts in the harshest conditions, this Type W cable is often used in mining equipment and drilling rigs. It resists abrasion if you drag it across rocky terrain and won’t get crushed even when heavy equipment drives over it. The EPDM jacket stands up to chemicals, oil, and moisture. MSHA accepted, it meets mining safety standards, so you can rely on it where other power cables fail.
    Outer
    Jacket
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    2,000V AC/2,000V DC
     
    Type W Cable
    8/2
    74 amp @ 86° FEPDM
    Black-40 to 190CSA Certified, MSHA Accepted, UL Listed
    2962N1000000000000000000000000000
    8/3
    74 amp @ 86° FEPDM
    Black-40 to 190CSA Certified, MSHA Accepted, UL Listed
    2962N4000000000000000000000000
    6/2
    99 amp @ 86° FEPDM
    Black-40 to 190CSA Certified, MSHA Accepted, UL Listed
    2962N200000000000000000000000000
    6/3
    99 amp @ 86° FEPDM
    Black-40 to 190CSA Certified, MSHA Accepted, UL Listed
    2962N500000000000000000000000000
    4/3
    130 amp @ 86° FEPDM
    Black-40 to 190CSA Certified, MSHA Accepted, UL Listed
    2962N6000000000000000000
    2/3
    174 amp @ 86° FEPDM
    Black-40 to 190CSA Certified, MSHA Accepted, UL Listed
    2962N700000000000000000000
     

    Continuous-Twist and -Flex Control Cable

    Image of Product. Front orientation. Control Cable. Continuous-Twist and -Flex Control Cable, Shielded.

    Shielded

    Ideal for multi-axis, torsional, and bending movements, this cable is often used in robot arms. It will endure millions of flex cycles while sending reliable signals, even when it's twisting. Internally, fine strands of conductors are twisted together like a rope, resisting fatigue from constant bending. On the outside, a rugged polyurethane jacket resists abrasion, chemicals, oil, and moisture.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Clean Room
    Std.
    Choose a Length, ft.
    1-99
    100-Up
    1,000V AC
     
    Shielded
    16/3
    21 amp @ 86° F3.3"Polyurethane Rubber
    Blue-10 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    10, 20, 30, 50, 1008559K350000000000
    16/4
    21 amp @ 86° F3.7"Polyurethane Rubber
    Blue-10 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    10, 20, 30, 50, 1008559K3700000000
    14/3
    30 amp @ 86° F3.9"Polyurethane Rubber
    Blue-10 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    10, 20, 30, 50, 1008559K3600000000
    14/4
    30 amp @ 86° F4.1"Polyurethane Rubber
    Blue-10 to 175UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 1
    10, 20, 30, 50, 1008559K3800000000
     

    Motor Winding Wire

    Image of Product. Front orientation. Magnet Wire. Motor Winding Wire.
    Also known as magnet wire, this wire is commonly used in motors, transformers, relays, and other high-speed winding applications. It stays in the position you bend it.
    ANSI/NEMA 1000 MW 35-C and ANSI/NEMA 1000 MW 73-C—Wire meets ANSI/NEMA 1000 MW 35-C for material quality and ANSI/NEMA 1000 MW 73-C for use in sealed motors and material quality.
    AWG
    OD
    Outer Jacket
    Material
    Max. Temp.,
    ° F
    Lg.,
    ft.
    Specs. Met
    Certification
    Each
    Solid Wire
    36
    0.01"Nylon
    3906,150ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K27000000
    36
    0.01"Nylon
    39012,300ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K8500000
    34
    0.01"Nylon
    3903,900ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K2800000
    34
    0.01"Nylon
    3907,800ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K8700000
    32
    0.01"Nylon
    3904,350ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K8900000
    32
    0.01"Nylon
    3908,700ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K8800000
    30
    0.01"Nylon
    3903,000ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K7100000
    30
    0.01"Nylon
    3906,000ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K4100000
    28
    0.02"Nylon
    3902,000ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K7300000
    28
    0.02"Nylon
    3904,000ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K4300000
    26
    0.02"Nylon
    3901,500ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K7500000
    26
    0.02"Nylon
    3903,000ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K5500000
    24
    0.02"Nylon
    390790ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K7700000
    24
    0.02"Nylon
    3902,000ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K5700000
    22
    0.03"Nylon
    390750ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K7900000
    22
    0.03"Nylon
    3901,500ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K59000000
    20
    0.04"Nylon
    390500ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K8100000
    20
    0.04"Nylon
    390900ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K61000000
    18
    0.04"Nylon
    390300ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K8300000
    18
    0.04"Nylon
    390600ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K6300000
    16
    0.06"Nylon
    390125ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K2100000
    16
    0.06"Nylon
    390250ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K2200000
    14
    0.07"Nylon
    39080ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K2300000
    14
    0.07"Nylon
    390160ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K2400000
    12
    0.09"Nylon
    39050ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K2500000
    12
    0.09"Nylon
    390100ANSI/NEMA 1000 MW 35-C, ANSI/NEMA 1000 MW 73-CUL Recognized Component
    7588K2600000
     

    Abrasion-Resistant Lead Wire

    Run power over rough surfaces—this wire has thick insulation that stands up to wear and tear. It’s flame rated, which means it meets requirements for preventing the spread of fire. Also known as hook-up wire.
    Stranded Wire with Aramid Fabric Outer Jacket and Silicone Rubber Inner Insulation
    Image of Product. Front orientation. Lead Wire. Abrasion-Resistant Lead Wire, Stranded Wire, Aramid Fabric Outer Jacket.
    Wire with aramid fabric outer and silicone rubber inner insulation is best for your most rugged applications, such as wiring inside a motor. Its outer layer protects the wire if it’s cut or struck. Meanwhile, its inner layer makes it flexible enough to bend in tight spots. It’s also known as silicone rubber motor lead (SRML) wire.
    AWG
    Wire Strand
    Count
    Current @
    Temp.
    OD
    Temp. Range,
    ° F
    Certification
    Flammability
    Rating
    Outer Jacket
    Color
    Choose a Length, ft.
    Per
    Ft.
    600V AC
    14
    7/2255 amp @ 86° F0.19"-40 to 390UL Recognized Component
    UL 2556 VW-1
    Black10, 25, 50, 100, 5006119N1100000
    12
    19/2470 amp @ 86° F0.21"-40 to 390UL Recognized Component
    UL 2556 VW-1
    Black10, 25, 50, 100, 5006119N120000
    10
    19/23
    92 amp @ 86° F0.23"-40 to 390UL Recognized Component
    UL 2556 VW-1
    Black10, 25, 50, 100, 5006119N130000
     
    back to top