About Exhaust Fans
More
About Calculating the Airflow Required for Air Cleaning
More
About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
About Air Preparation
More
Ceiling-Mount Lavatory Exhaust Fans





Use these fans to draw stagnant and humid air out of a room.
Fans that cannot be sold to the regions listed do not meet local energy efficiency requirements.
For technical drawings and 3-D models, click on a part number.


Guard | For Opening | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Dia. | Airflow, cfm | Volume, dBA | Lg. | Wd. | Wd. | Dia. | Dp. | Housing Material | Mount. Fasteners Included | Mount. Hole Dia. | Mount. Location | Features | Specifications Met | Cannot Be Sold To | Each | ||
120V AC, Single Phase—Hardwire | |||||||||||||||||
1 | 3" | 50 | 48 | 9 1/4" | 9" | 7 1/4" | __ | 3 5/8" | Steel | No | 1/8" | Ceiling, Wall | Backdraft-Preventing Damper | UL Listed | CO, DC, MA, MD, NJ, NV, NY, OR, RI, VT, WA | 0000000 | 000000 |
1 | 3" | 70 | 54 | 9 1/4" | 9" | 7 1/4" | __ | 3 5/8" | Steel | No | 1/8" | Ceiling, Wall | Backdraft-Preventing Damper | UL Listed | CO, DC, MA, MD, NJ, NV, NY, OR, RI, VT, WA | 0000000 | 00000 |
1 | 4" | 80 | 31 | 12" | 11 1/2" | 9 1/4" | __ | 5 3/4" | Steel | No | 3/16" | Ceiling, Wall | Backdraft-Preventing Damper | UL Listed | __ | 0000000 | 00000 |
2 | 8" | 200 | 58 | 11 1/2" | 11 1/2" | __ | 8 1/4" | 7" | Steel | No | 3/16" | Ceiling | Backdraft-Preventing Damper | UL Listed | CO, DC, MA, MD, NJ, NV, NY, OR, RI, VT, WA | 0000000 | 000000 |
120V AC, Single Phase—Plug | |||||||||||||||||
1 | 4" | 110 | 28 | 12" | 11 1/2" | 9 1/4" | __ | 5 3/4" | Steel | Yes | 1/4" | Ceiling, Wall | Backdraft-Preventing Damper | UL Listed | __ | 000000 | 000000 |

For Duct | Guard | For Opening | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Airflow, cfm | Volume, dBA | Lg. | Wd. | Wd. | Dp. | Housing Material | Mount. Fasteners Included | Mount. Hole Dia. | Mount. Location | Features | Specifications Met | Cannot Be Sold To | Each | ||
120V AC, Single Phase—Hardwire | |||||||||||||||||
3 | 3 1/4" | 10" | 160 | 51 | 11 1/2" | 11 1/2" | 12" | 3 1/4" | Steel | No | 3/16" | Ceiling, Wall | Backdraft-Preventing Damper | UL Listed | CO, DC, MA, MD, NJ, NV, NY, OR, RI, VT, WA | 0000000 | 0000000 |

For Duct | Guard | For Opening | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Oval Ht. | Oval Wd. | Airflow, cfm | Volume, dBA | Lg. | Wd. | Wd. | Dp. | Housing Material | Mount. Fasteners Included | Mount. Hole Dia. | Mount. Location | Features | Specifications Met | Each | |
120V AC, Single Phase—Hardwire | |||||||||||||||
2" | 4" | 50, 80, 100 | 31 | 13 3/4" | 13" | 10 1/4" | 3 3/8" | Steel | Yes | 7/16" | Ceiling, Wall | Backdraft-Preventing Damper | C-ETL Listed, ETL Listed | 0000000 | 0000000 |

For Duct | Guard | For Opening | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Dia. | Oval Ht. | Oval Wd. | Airflow, cfm | Volume, dBA | Lg. | Wd. | Wd. | Dp. | Housing Material | Mount. Fasteners Included | Mount. Hole Dia. | Mount. Location | Features | Specifications Met | Each | |
120V AC, Single Phase—Hardwire | ||||||||||||||||
3" | 2" | 4" | 80 | 28 | 13 3/4" | 13" | 10 1/2" | 4" | Steel | Yes | 7/16" | Ceiling, Wall | Backdraft-Preventing Damper | C-UL Listed, UL Listed | 0000000 | 0000000 |
Ceiling-Mount Lavatory Exhaust Fans with Lights

These fans have a light that can operate alone or share a switch with the fan. Use them to draw stagnant and humid air out of a room.
Fans that cannot be sold to the regions listed do not meet local energy efficiency requirements.
For technical drawings and 3-D models, click on a part number.
Guard | For Opening | Bulb | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Dia. | Airflow, cfm | Volume, dBA | Lg. | Wd. | Wd. | Dp. | Housing Material | Included | No. Required | Max. Wattage, W | Mount. Fasteners Included | Mount. Hole Dia. | Features | Specifications Met | Cannot Be Sold To | Each | |
For Round Duct | |||||||||||||||||
120V AC, Single Phase—Hardwire | |||||||||||||||||
4" | 50 | 41 | 11 1/8" | 10 5/8" | 8" | 5 3/4" | Steel | No | 1 | 100 | No | 3/16" | Backdraft-Preventing Damper, Light | UL Listed | CO, DC, MA, MD, NJ, NV, NY, OR, RI, VT, WA | 0000000 | 000000 |
4" | 70 | 38 | 12 1/8" | 11 1/2" | 9 1/4" | 5 3/4" | Steel | No | 1 | 100 | No | 3/16" | Backdraft-Preventing Damper, Light | UL Listed | CO, DC, MA, MD, NJ, NV, NY, OR, RI, VT, WA | 0000000 | 000000 |
120V AC, Single Phase—Plug | |||||||||||||||||
4" | 110 | 28 | 12 1/2" | 11 3/4" | 9 1/4" | 5 3/4" | Steel | Built-In LED | __ | __ | Yes | 1/4" | Backdraft-Preventing Damper, Light | UL Listed | __ | 0000000 | 000000 |
Motion-Activated Ceiling-Mount Lavatory Exhaust Fans
When a room is occupied, these fans detect the motion and turn on. Set them to turn off anywhere from 30 seconds to 80 minutes after motion is no longer detected. They also sense humidity levels in the room and turn the fan on until the humidity level falls below a set percentage. You can set them to a maximum of 80% relative humidity.

Guard | For Opening | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Wd. | Airflow, cfm | Volume, dBA | Lg. | Wd. | Lg. | Wd. | Dp. | Housing Material | Mount. Fasteners Included | Mount. Hole Dia | Features | Each | |
For Round Duct | |||||||||||||
120V AC, Single Phase—Hardwire | |||||||||||||
6" | 130 | 23 | 14 1/4" | 14 1/4" | 13" | 12 7/8" | 9 7/8" | Steel | No | 3/8" | Backdraft-Preventing Damper | 0000000 | 0000000 |

Guard | For Opening | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct Wd. | Airflow, cfm | Volume, dBA | Lg. | Wd. | Lg. | Wd. | Dp. | Housing Material | Mount. Fasteners Included | Mount. Hole Dia | Features | Each | |
For Round Duct | |||||||||||||
120V AC, Single Phase—Hardwire | |||||||||||||
6" | 130 | 23 | 17" | 15 7/8" | 13" | 12 7/8" | 9 7/8" | Steel | No | 3/8" | Backdraft-Preventing Damper, Light | 0000000 | 0000000 |
Ultra-Quiet Ceiling-Mount Lavatory Exhaust Fans
Keep noise to a minimum with 1/2" thick acoustical insulation and vibration-resistant motor mounts. Use these fans to draw stagnant and humid air out of a room.
Speed controls are optional. They fit single-gang electrical boxes.
For technical drawings and 3-D models, click on a part number.


Exhaust Fans | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Guard | Speed Controls | |||||||||||||
For Duct Dia. | Airflow, cfm | Volume, dBA | Lg. | Wd. | Housing Material | Mount. Fasteners Included | Mount. Hole Dia. | Mount. Location | Features | Specifications Met | Each | Each | ||
120V AC, Single Phase—Hardwire | ||||||||||||||
8" | 130 | 10 | 14" | 14" | Steel | Yes | 13/32" | Ceiling, Wall | Backdraft-Preventing Damper, Vibration-Resistant Mounts | UL Listed | 0000000 | 0000000 | 0000000 | 000000 |
8" | 200 | 28 | 14" | 14" | Steel | Yes | 13/32" | Ceiling, Wall | Backdraft-Preventing Damper, Vibration-Resistant Mounts | UL Listed | 0000000 | 000000 | 0000000 | 00000 |
8" | 230 | 32 | 14" | 14" | Steel | No | 1/2" | Ceiling, Wall | Backdraft-Preventing Damper, Vibration-Resistant Mounts | UL Listed | 0000000 | 000000 | 0000000 | 00000 |
8" | 270 | 33 | 14" | 14" | Steel | Yes | 13/32" | Ceiling, Wall | Backdraft-Preventing Damper, Vibration-Resistant Mounts | UL Listed | 0000000 | 000000 | 0000000 | 00000 |
8" | 310 | 41 | 14" | 14" | Steel | Yes | 13/32" | Ceiling, Wall | Backdraft-Preventing Damper, Vibration-Resistant Mounts | UL Listed | 0000000 | 000000 | 0000000 | 00000 |


Exhaust Fans | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Duct | Guard | Speed Controls | |||||||||||||
Ht. | Wd. | Airflow, cfm | Volume, dBA | Lg. | Wd. | Housing Material | Mount. Fasteners Included | Mount. Hole Dia. | Mount. Location | Features | Specifications Met | Each | Each | ||
120V AC, Single Phase—Hardwire | |||||||||||||||
5" | 19" | 480 | 40 | 23 1/4" | 14" | Steel | No | 1/2" | Ceiling, Wall | Backdraft-Preventing Damper, Vibration-Resistant Mounts | UL Listed | 0000000 | 0000000 | 0000000 | 000000 |
Ceiling Fans
Mount these fans on flat ceilings. They include a support cable or downrods to mount them into joists. All have optional speed control.
Optional installation kits (sold separately) allow fans to mount between joists.
Fans that cannot be sold to the listed regions do not meet energy efficiency regulations.
For technical drawings and 3-D models, click on a part number.


Fans | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade | Installation Kits | |||||||||||||
Blade Dia. | Airflow, cfm | No. of Speeds | Current, A | Rotation | Material | Color | For Min. Ceiling Ht., ft. | Mounting Fasteners Included | Includes | Specifications Met | Each | Each | ||
120V AC, Single Phase—Hardwire | ||||||||||||||
Non-Oscillating | ||||||||||||||
36" | 2,126 | 1 | 0.3 | Reversible | Painted Steel | White | 10 | Yes | Support Cable, 24" Downrod | C-UL Listed, UL Listed | 0000000 | 0000000 | 0000000 | 000000 |
48" | 3,861 | 1 | 0.4 | Reversible | Painted Steel | White | 10 | Yes | Support Cable, 24" Downrod | C-UL Listed, UL Listed | 0000000 | 000000 | 0000000 | 00000 |
56" | 8,959 | 1 | 0.9 | Nonreversible | Painted Steel | White | 10 | Yes | Support Cable, 24" Downrod | C-UL Listed, UL Listed | 0000000 | 000000 | 0000000 | 00000 |
60" | 6,090 | 1 | 0.6 | Nonreversible | Painted Steel | White | 10 | Yes | Support Cable, 24" Downrod | C-UL Listed, UL Listed | 0000000 | 000000 | 0000000 | 00000 |


Blade | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | No. of Speeds | Current, A | Rotation | Material | Color | Brightness, lumens | For Min. Ceiling Ht., ft. | Mounting Fasteners Included | Includes | Specifications Met | Cannot Be Sold To | Each | |
120V AC, Single Phase—Hardwire | ||||||||||||||
Non-Oscillating | ||||||||||||||
60" | 6,600 | 6 | 0.7 | Reversible | Plastic | White | 1,520 | 9 | Yes | 2" Downrod, 9" Downrod, Remote Control | ETL Listed | __ | 0000000 | 0000000 |
60" | 13,000 | 8 | 0.5 | Reversible | Powder-Coated Aluminum | Black | 2,600 | 11 | Yes | 11" Downrod, Remote Control | ETL Listed, UL 507 | __ | 0000000 | 00000000 |
72" | 17,900 | 8 | 0.6 | Reversible | Powder-Coated Aluminum | Black | 2,600 | 11 | Yes | 11" Downrod, Remote Control | ETL Listed, UL 507 | __ | 0000000 | 00000000 |
84" | 22,100 | 8 | 0.5 | Reversible | Powder-Coated Aluminum | Black | 2,600 | 11 | Yes | 11" Downrod, Remote Control | ETL Listed, UL 507 | __ | 0000000 | 00000000 |
96" | 22,000 | 8 | 1.1 | Reversible | Powder-Coated Aluminum | Black | 2,600 | 11 | Yes | 11" Downrod, Remote Control | ETL Listed, UL 507 | Canada | 0000000 | 00000000 |
Octagonal Steel Outlet Boxes with Knockouts
Knockouts allow you to modify these boxes to fit your application.
For technical drawings and 3-D models, click on a part number.

No. of Knockouts | Knockout Trade Size | Ht. | Wd. | Dp. | Capacity, cu. in. | Finish | Each | |
4 | 1/2 | 4" | 4" | 1 1/2" | 15.5 | Zinc Plated | 00000000 | 00000 |

Ht. | Wd. | Finish | Mounting Fasteners Included | Each | |
4" | 4" | Zinc Plated | No | 00000000 | 00000 |

No. of Knockouts | Knockout Trade Size | Ht. | Wd. | Finish | Mounting Fasteners Included | Each | |
1 | 1/2 | 4" | 4" | Zinc Plated | No | 00000000 | 00000 |

For Max. No. of Devices | Ht. | Wd. | Finish | Mounting Fasteners Included | Each | |
1 | 4" | 4" | Zinc Plated | No | 00000000 | 00000 |
Fan-Cooled Compressed Air Aftercoolers

These aftercoolers have a fan that chills hot air coming from a compressor. Cooling the air condenses water for removal from your compressed air system. Install a separator (not included) after your aftercooler to collect and discharge water.
For technical drawings and 3-D models, click on a part number.
Air Inlet | Air Outlet | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Max. Pressure, psi | Max. Flow Rate @ psi | Max. Temp., °F | Cools Air Within | Ht. | Wd. | Dp. | hp | Each | |
Ceiling-, Floor-, and Wall-Mount | |||||||||||||||
Single Phase, 115-230V AC | |||||||||||||||
1 | NPT | Female | 1 | NPT | Female | 250 | 50 scfm @ 80 | 350° | 15° F of Ambient Air | 12 7/8" | 19 1/2" | 13 3/4" | 1/3 | 0000000 | 000000000 |
1 1/2 | NPT | Female | 1 1/2 | NPT | Female | 250 | 100 scfm @ 80 | 350° | 15° F of Ambient Air | 13 1/4" | 19 1/2" | 15 1/8" | 1/3 | 0000000 | 00000000 |
1 1/2 | NPT | Female | 1 1/2 | NPT | Female | 250 | 200 scfm @ 80 | 350° | 15° F of Ambient Air | 17 1/4" | 23 1/4" | 16 1/4" | 1/2 | 0000000 | 00000000 |
Ceiling-Mount Office Air Cleaners

Save floor space—cleaners mount in a T-bar style ceiling to remove contaminants.
These cleaners cannot be sold to California due to local energy efficiency requirements.
Reusable prefilter can be washed.
Reusable electrostatic filter has an inherent electrostatic charge attracts particles. It can be washed.
For Ceiling Tile | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Voltage | Current | Lg. | Wd. | Lg. | Ht. | Wd. | Housing Material | Includes | For Removing | Cannot Be Sold To | Each | |
White Housing | ||||||||||||||
500 | 43 dB @ 15 ft. | 120V AC | 1.8A | 24" | 48" | 23 3/4" | 11" | 47 3/4" | Steel | Disposable HEPA/Odor-Removal Filter (Captures 99.97% of particles down to 0.3 microns), Reusable Prefilter | Dust and Particles | CA | 0000000 | 000000000 |
650 | 45 dB @ 15 ft. | 120V AC | 2.6A | 24" | 48" | 23 3/4" | 11" | 47 3/4" | Steel | Disposable Odor-Removal After-Filter, Reusable Electrostatic Filter (Captures 97% of particles down to 0.01 microns), Reusable Prefilter | Dust and Particles | CA | 0000000 | 00000000 |
Black Housing | ||||||||||||||
500 | 43 dB @ 15 ft. | 120V AC | 1.8A | 24" | 48" | 23 3/4" | 11" | 47 3/4" | Steel | Disposable HEPA/Odor-Removal Filter (Captures 99.97% of particles down to 0.3 microns), Reusable Prefilter | Dust and Particles | CA | 0000000 | 00000000 |
650 | 45 dB @ 15 ft. | 120V AC | 2.6A | 24" | 48" | 23 3/4" | 11" | 47 3/4" | Steel | Disposable Odor-Removal After-Filter, Reusable Electrostatic Filter (Captures 97% of particles down to 0.01 microns), Reusable Prefilter | Dust and Particles | CA | 0000000 | 00000000 |