    14 Products

    DIN-Rail Mount Electronic Circuit Breakers

    An electronic trip mechanism makes these circuit breakers fast, precise, and consistent. They continuously monitor current and trip at a precise value compared to the much wider current range in traditional thermal-magnetic breakers. They're good for protecting devices that could be easily damaged by overcurrent such as sensors, HMIs, and controllers. Because they trip electronically, they don't require the bulky housing necessary for thermal trip mechanisms, so they take up less space in your control cabinet. They also eliminate the need for accessories, such as shunt trips, because they can be remotely monitored and controlled. For at the source troubleshooting, they have an indicator light and on/off/reset button for each circuit. To make sure your equipment is receiving the correct voltage, these breakers will also trip when the supply voltage goes under or over a set value.
    Adjustable—IO Link
    Image of System. Front orientation. Contains MultipleImages. Circuit Breakers. DIN-Rail Mount Electronic Circuit Breakers, Push-Button Style, 4 Circuits Controlled.
    Image of System. Front orientation. Contains MultipleImages. Circuit Breakers. DIN-Rail Mount Electronic Circuit Breakers, Push-Button Style, 8 Circuits Controlled.

    Push-Button Style

    4 Circuits Controlled

    Push-Button Style

    8 Circuits Controlled

    Adjustable-current breakers let you choose the current at which they’ll trip. As your operation changes, you can adjust when these breakers will trip rather than replacing the entire breaker.
    Breakers with IO Link give you more control than breakers with digital input/outputs. Not only can you check the status to reset or turn your breaker on and off, but you can also adjust their current and view current in real-time. This is helpful when troubleshooting issues such as a breaker that repeatedly trips.
    4 Circuits Controlled and 8 Circuits Controlled—Breakers that control 4 or 8 circuits allow you to individually set each circuit. If one trips, the others will keep working.
    No. of Circuits
    Controlled
    Current, A
    Voltage,
    V DC
    For DIN
    Rail Size, mm
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Enclosure
    Rating
    Each
    Push-Button Style
    41, 2, 3, 4, 5, 6, 7, 8, 9, 102435Spring-Clamp Terminal3.54"1.77"4.55"-10 to 145IP20
    3897N190000000
    81, 2, 3, 4, 5, 6, 7, 8, 9, 102435Spring-Clamp Terminal5"1.65"5.61"-10 to 145IP20
    3897N22000000
     

    Current-Monitoring Relays

    Image of Product. Front orientation. Contains Annotated. Monitoring Relays. Current-Monitoring Relays, Screw Terminals with IO Link, Keypad Adjustment.
    Image of Product. Front orientation. Contains Annotated. Monitoring Relays. Current-Monitoring Relays, Spring-Clamp Terminals with IO Link, Keypad Adjustment.

    Screw Terminals

    with IO Link,

    Keypad Adjustment

    Spring-Clamp

    Terminals with IO

    Link, Keypad

    Adjustment

    Protect electrical equipment from overcurrent and undercurrent damage—these relays continuously monitor current flow. When current is outside a set range, they trip and cut power to prevent overheating, fire hazards, and stalling. Rated IP20, these relays have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on a 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
    Spring-Clamp-Terminal Wire Connection—Relays with spring-clamp terminals connect and disconnect to wire without screws. Because there’s no screw, these connections are less likely to loosen over time, even in high-vibration environments.
    IO Link Communication Protocol—Relays with IO link can be programmed, monitored, and reset remotely by connecting them to a programmable logic controller (PLC), human-machine interface (HMI), or computer. If you want to program them locally, they have a keypad.
    No. of
    Terminals
    Input Voltage,
    V DC
    Trip Current,
    amp
    Trip Time,
    sec.
    Reset
    Type
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Adjustment Mechanism
    Ht.
    Wd.
    Dp.
    Digital Display
    Type
    Each
    Screw Terminals with IO Link
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    9240.05 to 100 to 999Automatic3 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad3.6"0.9"3.4"LCD8123N110000000
     
    Spring-Clamp Terminals with IO Link
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    9240.05 to 100 to 999Automatic3 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad3.8"0.9"3.4"LCD8123N12000000
     

    Ground-Fault Monitoring Relays

    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Ground-Fault Monitoring Relays, Screw Terminals with IO Link.
    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Ground-Fault Monitoring Relays, Spring-Clamp Terminals with IO Link.

    Screw Terminals with

    IO Link

    Spring-Clamp

    Terminals with IO

    Link

    Detect and mitigate ground faults to prevent harm to equipment, circuits, and people. These relays monitor the differential between incoming and outgoing current, also known as residual current. When the balance is off, they trip and cut power to the circuit. These relays are highly sensitive, so you can trust them to de-energize faulty circuits before a minor issue becomes a major one. Rated IP20, they have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
    These relays require a current-indicating ring (sold separately) to operate. Choose a ring that is large enough for your lines to pass through. Feed the lines of the circuit through the center of the ring and connect the indicating ring output to the relay.
    Spring-Clamp-Terminal Wire Connection—Relays with spring-clamp terminals connect and disconnect to wire without screws. Because they don’t have screws, there’s less of a risk that they will loosen over time, even when they’re under vibration.
    IO Link Communication Protocol—Relays with IO link can be programmed, monitored, and reset remotely by connecting them to a programmable logic controller (PLC), human-machine interface (HMI), or computer. If you want to program them locally, they have a keypad.
    No. of
    Terminals
    Input Voltage,
    V DC
    Trip Current,
    amp
    Trip Time,
    sec.
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Adjustment Mechanism
    Ht.
    Wd.
    Dp.
    Features
    Each
    Screw Terminals with IO Link
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    12240.03 to 400 to 9993 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad4"0.9"3.6"Remote Reset8121N1090000000
     
    Spring-Clamp Terminals with IO Link
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    12240.03 to 400 to 9993 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad4.1"0.9"3.6"Remote Reset8121N111000000
     
    Current Indicating Rings

    Voltage-Monitoring Relays

    Safeguard your equipment against overheating, wear, and malfunction from a spike or dip in voltage. These relays continuously monitor your AC or DC power supply and trip when the voltage is outside a set range. Rated IP20, these relays have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on a 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
    Monitoring Relays with IO Link
    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Voltage-Monitoring Relays, Monitoring Relays with IO Link.
    Relays with IO link can be programmed, monitored and reset remotely by connecting them to a programmable logic controller (PLC), human-machine interface (HMI), or computer. If you want to program them locally, they have a keypad.
    With Spring-Clamp Terminals—Relays with spring-clamp terminals connect and disconnect to wire without screws. Because there’s no screw, these connections are less likely to loosen over time, even in high-vibration environments.
    No. of
    Terminals
    Input Voltage,
    V DC
    Trip Voltage
    Trip Time,
    sec.
    Reset
    Type
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Adjustment Mechanism
    Ht.
    Wd.
    Dp.
    Digital Display
    Type
    Features
    Each
    1 Circuit Controlled with 1 Off or 1 On—SPDT
     
    With Screw Terminals
    92410V AC to 600V AC, 10V DC to 600V DC0 to 999Automatic3 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad3.6"0.9"3.6"LCDRemote Reset8446N1050000000
     
    With Spring-Clamp Terminals
    92410V AC to 600V AC, 10V DC to 600V DC0 to 999Automatic3 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad3.8"0.9"3.6"LCDRemote Reset8446N106000000
     

    Multifunction Monitoring Relays

    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Multifunction Monitoring Relays.
    Monitor phase, voltage, and frequency at the same time to protect motors, generators, and other three-phase circuits from burning out or overheating. They'll switch the circuit off if they detect voltage or frequencies outside of the set range or phase loss, imbalance, or reversal. Rated IP20, they have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on a 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
    These relays use IO Link, so they can be programmed, monitored, and reset remotely by connecting them to a programmable logic controller (PLC), human-machine interface (HMI), or computer. If you want to program them locally, they have a keypad.
    Spring-Clamp-Terminal Wire Connection—Relays with spring-clamp terminals connect and disconnect to wire without screws. Because there’s no screw, these connections are less likely to loosen over time, even in high-vibration environments.
    No. of
    Terminals
    Input Voltage,
    V DC
    Trip Voltage,
    V AC
    Input Freq.,
    Hz
    Trip Freq.,
    Hz
    Trip Time,
    sec.
    Reset
    Type
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Adjustment Mechanism
    Ht.
    Wd.
    Dp.
    Each
    1 Circuit Controlled with 1 Off or 1 On—SPDT
     
    Screw Terminals with IO Link
    122490 to 76050, 6015 to 700.1 to 30Automatic3 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad3.9"0.9"3.6"8449N120000000
     
    Spring-Clamp Terminals with IO Link
    122490 to 76050, 6015 to 700.1 to 30Automatic3 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad3.9"0.9"3.6"8449N11000000
     
    back to top