Filter by
Test End Component
AC Current
Electrical Safety Rating
For Fluke Model Number
Measurement Unit
AC Calculation
Software Features
Manufacturer Model Number
Display Features
DFARS Specialty Metals
Calculation Features
Fluke Wireless Remote-Reading Clamp-on-Jaw Current Meters
![]() |
Take current measurements from a distance with these high-quality, durable Fluke meters. They wirelessly transmit readings to a separate display. Because the jaws surround a cable, these meters are convenient for taking frequent measurements since you don't have to interrupt the circuit.
The meters work with the Fluke 3000 FC multimeter, a computer with a Fluke pc3000 FC connector plugged in (not included), or a mobile device that has the Fluke Connect app.
True RMS AC Calculation—These true RMS current meters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. For example, a 1,000-count meter shows numbers up to 999. A higher display count means the meter can give a more precise measurement.
Mfr. Model No. | Test End Component | Jaw Opening | Electrical Safety Rating | Measures | Max. AC Current, amp | Data Log Cap. | Display Count | Includes | Certification | Batteries Included | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
a3000 FC | Current Clamp | 1.33" | CAT III, 600V | AC Current | 400 | 65,000 | 1,000 | — | CSA Certified, CSA-US Certified | Yes | 00000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
a3001 FC | Current Loop | 10" | CAT IV, 600V | AC Current | 2,500 | 65,000 | 2,500 | Magnetic Hanger | CSA Certified, CSA-US Certified | Yes | 00000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Clamp-on-Jaw Multimeters
![]() |
Jaws surround a cable to test current without interrupting the circuit, making these high-quality, durable Fluke multimeters especially useful for testing high current. They include test leads to perform other electrical tests.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | Test Leads | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Multimeters | Multimeters with Calibration Certificate | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Mfr. Model No. | Jaw Opening | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Display Count | Includes | Each | Each | Pair | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
325 | 1.18" | CAT III, 600V; CAT IV, 300V | AC Current, AC Voltage, Capacitance, DC Voltage, Resistance, Temperature | 600 | 600 | 1% | 400 | — | 6,000 | Carrying Case, Temperature Probe, Test Leads | 00000000 | 0000000 | 00000000 | 0000000 | 00000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
355 | 2.3" | CAT IV, 600V | AC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance | 600 | 1,000 | 1% | 2,000 | 2,000 | 10,000 | Alligator Clips, Carrying Case, Test Leads, Test Probes | 00000000 | 00000000 | ——— | 0 | ——— | 0 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
374 FC | 1.3" | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance | 1,000 | 1,000 | 1% | 600 | 600 | 6,000 | Carrying Case, Test Leads | 00000000 | 000000 | 00000000 | 000000 | ——— | 0 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
376 FC | 1.3" | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 1% | 2,500 | 999.9 | 6,000 | Carrying Case, Flexible Current Loop, Test Leads | 00000000 | 000000 | 00000000 | 000000 | ——— | 0 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
381 | 1.34" | CAT IV, 600V | AC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 1% | 2,500 | 999.9 | 6,000 | Alligator Clips, Carrying Case, Flexible Current Loop, Removable Wireless Display, Test Leads | 00000000 | 000000 | 00000000 | 000000 | ——— | 0 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Clamp-on-Jaw Multimeters
![]() |
Suitable for testing high current, these multimeters have jaws that surround a cable to test without interrupting the circuit. They include test leads to perform other electrical tests.
Average-Sensing AC Calculation—Average-sensing multimeters take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors.
True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
Multimeters | Test Leads | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Jaw Opening | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Max. DC Current, amp | Display Count | Includes | Each | Pair | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Average-Sensing AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1" | CAT III, 600V | AC Current, AC Voltage, Capacitance, DC Voltage, Frequency, Resistance, Temperature | 600 | 600 | 1% | 600 | — | 4,000 | Carrying Case, Temperature Probe, Test Leads | 0000000 | 0000000 | 0000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.18" | CAT III, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 750 | 1,000 | 0.8% | 600 | 600 | 6,000 | Temperature Probe, Test Leads | 0000000 | 000000 | 0000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.18" | CAT IV, 300V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance | 600 | 600 | 1% | 600 | 600 | 6,000 | Carrying Case, Test Leads | 0000000 | 000000 | 0000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.7" | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 1.5% | 1,000 | — | 6,000 | Built-In Infrared Temperature Sensor, Carrying Case, Test Leads | 0000000 | 000000 | 0000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.7" | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature | 1,000 | 1,000 | 2.0% | 1,000 | 1,000 | 6,000 | Built-In Infrared Temperature Sensor, Carrying Case, Temperature Probe, Test Leads | 0000000 | 000000 | 0000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2" | CAT IV, 600V | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance | 1,000 | 1,000 | 0.8% | 1,000 | 1,000 | 6,000 | Carrying Case, Test Leads | 0000000 | 000000 | 0000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Clamp-on-Jaw Current Meters
![]() |
Measure current without interrupting the circuit—jaws surround a cable for testing, making these meters convenient for taking frequent measurements.
Average-Sensing AC Calculation—These current meters are average sensing, so they take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors.
Display Count—Display count is an industry designation and not an actual value. For example, a 2,000-count meter shows numbers up to 1,999. A higher display count means the meter can give a more precise measurement.
Electrical Safety Rating | AC Current | Current Accuracy | Measures | Jaw Opening | Includes | Display Count | Batteries Included | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Average-Sensing AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
CAT III, 300V | 0 amp to 20 amp, 0 amp to 200 amp | 2% to 3% | AC Current | 1.25" | Carrying Case | 2,000 | Yes | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Meters for Solar Power Systems
Find the best spot for new solar panels or check the performance of existing ones. These tools measure solar power in different ways, helping you comply with IEC 62446-1, a standard for testing, documenting, and maintaining solar panels connected to the grid. The data hold function freezes a measurement on the screen, so you have time to write it down. CE marked, all meet European safety standards.
Solar Irradiance Meter Kits
![]() |
Solar irradiance meter kits include tools to measure current and voltage, so you can check if your panels are generating the expected power. To test current, position your panel’s wiring within the jaws of the clamp meter. Or, if your wiring is hard to reach or clamp around, attach the flexible AC probe to the clamp meter and loop it around your wiring. Neither method will interrupt your circuit, making frequent measurements possible. To measure voltage, wire the clamp meter’s test leads to your solar panel or power station.
UV Light | Current Range, amp | Voltage Range | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Measuring Increments, W/m² | Measurement Range, W/m² | Measurement Accuracy | Temp. Range | AC | DC | AC, V AC | DC, V DC | Data Connection | Batteries Included | Features | Includes | Each | ||
1 | 0 to 1,400 | -5% to 5% | -22° F to 212° F -30° C to 100° C | 0 to 999.9 | 0 to 999.9 | 0 to 1,000 | 0 to 1,500 | 3.5 mm Audio, Bluetooth | Yes | Angle Indicator, Compass, Data Hold | Temperature Probe, Voltage/Current Clamp Meter (Rated CAT III 1500 V), 18" Lg. Flexible AC Probe, Magnetic Hanging Strap, Carrying Case | 0000000 | 000000000 |
Fluke Test Lead Sets
![]() | ![]() |
Model Number FTPL-1 | Model Number TL175 |
![]() | ![]() |
Model Number TL222 | Model Number TL224 |
![]() | ![]() |
Model Number TL26A | Model Number TL27 |
![]() | ![]() |
Model Number TL28A | Model Number TL40 |
![]() | ![]() |
Model Number TL71 | Model Number TL75 |
![]() | ![]() |
Model Number TL76 | Model Number TL910 |
Connect to Fluke multimeters with a set of red and black test leads.
The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Mfr. Model No. | For Fluke Model No. | Test End | Connection End | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | Certification | No. of Cords | Cord Lg. | Color | Test End Material | Pair | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FTPL-1 | 289 | Notched Threaded Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 0000000 | |
TL175 | 77IV, 113, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289 | Notched Threaded Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 00000 | |
TL222 | 83V, 87V, 787 | Sheathed Banana Plug | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT III, 1,000V; CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 60" | Black, Red | Copper | 00000000 | 00000 | |
TL224 | 87V, 107, 179, 233, 287, 3000 | Sheathed Banana Plug | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT III, 1,000V; CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 60" | Black, Red | Copper | 00000000 | 00000 | |
TL26A | 83V, 87V, 88V/A, 107, 179, 287, 289 | Serrated Alligator Clip | Sheathed Standard Banana Plug | 30 | 30 | 8 | — | CSA Certified, CSA-US Certified | 2 | 60" | Black, Red | Nickel-Plated Copper | 00000000 | 00000 | |
TL27 | 107, 175, 177, 179, 787 | Sheathed Banana Plug | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT III, 1,000V | CSA Certified, CSA-US Certified | 2 | 60" | Black, Red | Copper | 00000000 | 00000 | |
TL28A | 88V/A, 107, 175, 177, 179, 287, 289 | Serrated Alligator Clip | Sheathed Standard Banana Plug | 30 | 30 | 10 | CAT I, 30V | CSA Certified, CSA-US Certified | 2 | 60" | Black, Red | Copper | 00000000 | 00000 | |
TL40 | 83V, 87V, 88V/A, 287, 289, 787 | Retractable Probe Tip | Sheathed Standard Banana Plug | 600 | 600 | 3 | CAT II, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Stainless Steel | 00000000 | 00000 | |
TL71 | 27 II, 28 II, 83V, 87V, 88V, 114, 115, 116, 117, 175, 177, 179, 233, 787, 789 | Notched Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 00000 | |
TL75 | 83V, 87V, 113, 175, 177, 179, 287, 289, 787, 789 | Notched Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT IV, 600V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 00000 | |
TL76 | 87V, 107, 179, 287, 289, 787 | Pointed Threaded Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT II, 1,000V | CSA Certified, CSA-US Certified | 2 | 48" | Black, Red | Nickel-Plated Brass | 00000000 | 00000 | |
TL910 | 83V, 87V, 287, 289, 787 | Pointed Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 3 | CAT II, 1,000V | CSA Certified, CSA-US Certified | 2 | 40" | Black, Red | Gold-Plated Copper | 00000000 | 00000 |
Current-Sensing Test Leads
![]() | ![]() |
Current Loop | Current Clamp |
Measure current without interrupting the circuit by connecting these test leads to a multimeter or current meter.
The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter or current meter.
These test leads step down the sensed current to a level that works with a multimeter or current meter—the signal reduction ratio is the factor by which they reduce current.
Test End | For Max. Cord Dia. | Connection End | AC Current, amp | DC Current, amp | Current Accuracy | Voltage Output Signal Per Amp Supplied | For Current Range | AC Voltage, V AC | Electrical Safety Rating | Freq. Range, kHz | Jaw Opening | Loop Opening | Cord Lg. | Batteries Req. | Batteries Included | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Measures AC Current | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flexible Current Loop | — | Sheathed Standard Banana Plug | 5 to 3,000 | — | 1% | 10.000 mV AC, 1.000 mV AC, 1.000 mV DC | 5 amp to 300 amp 50 amp to 3,000 amp | 1,000 | CAT IV, 600V | 5 to 40 | — | 7.6" | 78" | Yes | Yes | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Measures AC Current and DC Current | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Current Clamp | 1.22" | Sheathed Standard Banana Plug | 0 to 1,000 | 0 to 1,000 | 1% | 1.000 mV AC, 1.000 mV DC | 0 amp to 200 amp 0 amp to 1,000 amp | 300 | CAT III, 300V | 0 to 10 | 1.25" | — | 59" | Yes | Yes | 00000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Current-Sensing Test Leads
![]() |
Current Clamp |
Measure current without interrupting the circuit by connecting these test leads to a multimeter or current meter.
The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter or current meter.
These test leads step down the sensed current to a level that works with a multimeter or current meter—the signal reduction ratio is the factor by which they reduce current.
Mfr. Model No. | Test End | For Max. Cord Dia. | Connection End | AC Current, amp | Current Accuracy | Current Output Signal per amp Supplied, mA | For Current Range | AC Voltage, V AC | Electrical Safety Rating | Freq. Range | Jaw Opening | For Fluke Model No. | Cord Lg. | Batteries Req. | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Measures AC Current | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
i400 | Current Clamp | 1.25" | Sheathed Standard Banana Plug | 1 to 400 | 2% | 1.000 | 1 amp to 400 amp | 1,000 | CAT IV, 600V | 5 Hz to 20 kHz | 1.25" | 27 II, 28 II, 77IV, 83V, 87V, 179, 287, 289, 787, 789, 1577, 1587 | 59" | No | 0000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Analog Clamp-on-Jaw Multimeters
![]() |
Measure rapidly changing electrical values more easily than with digital multimeters. Convenient for taking frequent high current measurements, the meters have jaws that surround a cable to test current without interrupting the circuit. Use the included test leads to perform other electrical tests.
Average-Sensing AC Calculation—Average-sensing multimeters take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors.
Batteries | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Jaw Opening | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Max. AC Current, amp | Hardware Features | Includes | Size | Req. | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Average-Sensing AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.5" | AC Current, AC Voltage, DC Voltage, Resistance | 600 | 60 | 4% | 600 | Overload Protection | Test Leads | AA | Yes | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Test Lead Tips
![]() |
Adapt Fluke test leads to perform electrical tests in tight spaces. Attach these tips to test leads that have 4 mm banana plugs.
Test End | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | For Fluke Model No. | Test End Component | Connection End | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | Color | Material | Insulation Material | Pair | ||
TP1 | 83V, 87V, 175, 177, 179, 373, 374, 376, 381, 787, 789, T+PRO, T5-1000, T5-600 | Needle Tip | Standard Banana Jack | 1,000 | 1,000 | 10 | CAT II, 1,000V | Black, Red | Stainless Steel | Polypropylene | 0000000 | 000000 |
Fluke Test Lead Kits
![]() |
These kits include a set of red and black Fluke test leads with a variety of interchangeable tips.
The connection end on the test leads is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Mfr. Model No. | For Fluke Model No. | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | Includes | Cord Lg. | Color | Each | ||
---|---|---|---|---|---|---|---|---|---|---|---|
TL220 | 27 II, 28 II, 83V, 87V, 114, 115, 116, 117, 123, 175, 177, 179, 233, 287, 289, 373, 374, 787, 789 | 1,000 | 1,000 | 10 | CAT II, 1,000V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug Two Needle Tips Two Insulated Plunger Style Alligator Clips | 59" | Black, Red | 0000000 | 000000 | |
TLK-225 | 27 II, 28 II, 83V, 87V, 175, 177, 179, 287, 289, 787, 789, 1577, 1587 | 1,000 | 1,000 | 1 | CAT IV, 600V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug Two Needle Tips Two Insulated Alligator Clips Two Retractable Grabbers Two Retractable Precision Grabbers Two Retractable Precision Hooks Pouch | 59" | Black, Red | 0000000 | 000000 | |
TLK289 | 287, 289, 376, 381 | 1,000 | 1,000 | 3 | CAT II, 1,000V | Two Cords with Sheathed Straight Banana Plug and Sheathed Right-Angle Banana Plug Two Needle Tips Two Insulated Alligator Clips Two Retractable Grabbers Two Retractable Precision Hooks Thermocouple Magnetic Hanger Pouch | 59" | Black, Red | 0000000 | 000000 |
Build-Your-Own Test Leads
![]() | ![]() | ![]() |
Style A | Style B | Style C |
![]() | ![]() | ![]() |
Style D | Style E | Style F |
![]() | ![]() | ![]() |
Style G | Style H | Style J |
![]() | ![]() | |
Style K | Style L |
Choose your own combination of test lead tips and cords.
The connection end on the cords is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Cords
![]() | ![]() | ![]() |
Style A | Style B | Style C |
Style | Connection End | Connection End Shape | AC Voltage, V AC | DC Voltage | Current, amp | Electrical Safety Rating | No. of Cords | Cord Lg. | AWG | Color | Pair | |||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A | Sheathed Standard Banana Plug x Sheathed Standard Banana Plug | 90° Angle x 90° Angle | 1,000 | 1,000 mV DC | 10 | CAT III, 1,000V | 2 | 47" | 18 | Black, Red | 0000000 | 000000 | ||
B | Sheathed Standard Banana Plug x Sheathed Standard Banana Plug | Straight x 90° Angle | 1,000 | 1,000V DC | 10 | CAT III, 1,000V | 2 | 47" | 18 | Black, Red | 0000000 | 00000 | ||
C | Sheathed Standard Banana Plug x Sheathed Standard Banana Plug | Straight x Straight | 1,000 | 1,000V DC | 10 | CAT III, 1,000V | 2 | 47" | 18 | Black, Red | 0000000 | 00000 | ||
Tips
![]() | ![]() | ![]() | ![]() |
Style D | Style E | Style F | Style G |
![]() | ![]() | ![]() | ![]() |
Style H | Style J | Style K | Style L |
Style | Test End | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | Test End Material | Color | Pair | |||
---|---|---|---|---|---|---|---|---|---|---|---|
D | Alligator Clip | 1,000 | 1,000 | 20 | CAT II, 1,000V | Nickel-Plated Steel | Black, Red | 0000000 | 000000 | ||
E | Alligator Clip | 1,000 | 1,000 | 20 | CAT III, 1,000V | Nickel-Plated Brass | Black, Red | 0000000 | 00000 | ||
F | Pointed Banana Plug | 1,000 | 1,000 | 10 | CAT III, 1,000V | Nickel-Plated Brass | Black, Red | 0000000 | 00000 | ||
G | Retractable Grabber | 1,000 | 1,000 | 10 | CAT III, 1,000V | Nickel-Plated Brass | Black, Red | 0000000 | 00000 | ||
H | Precision Retractable Grabber | 1,000 | 1,000 | 10 | CAT II, 1,000V | Nickel-Plated Stainless Steel | Black, Red | 0000000 | 00000 | ||
J | Retractable Hook | 1,000 | 1,000 | 10 | CAT III, 1,000V | Nickel-Plated Copper | Black, Red | 0000000 | 00000 | ||
K | Precision Retractable Hook | 1,000 | 1,000 | 20 | CAT III, 1,000V | Nickel-Plated Brass | Black, Red | 0000000 | 00000 | ||
L | Retractable Insulation Piercing Grabber | 1,000 | 1,000 | 5 | CAT III, 1,000V | Stainless Steel | Black, Red | 0000000 | 000000 | ||
Test Lead Kits
![]() |
Perform electrical tests with a set of red and black test leads and interchangeable tips.
The connection end on the test leads is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Includes | Cord Lg. | Color | AWG | Each | ||
---|---|---|---|---|---|---|
Two Cords with Sheathed Straight and Sheathed Right-Angle Banana Plugs, CAT III, 1,000V, 10A Two Insulated Alligator Clips, CAT II, 1,000V, 10A Two Pointed Banana Plugs, CAT III, 1,000V, 10A Two Precision Retractable Grabbers, CAT II, 1,000V, 10A Pouch | 47" | Black, Red | 18 | 0000000 | 0000000 | |
Two Cords with Sheathed Straight and Sheathed Right-Angle Banana Plugs, CAT III, 1,000V, 10A Two Alligator Clips, CAT III, 1,000V, 10A Two Pointed Banana Plugs, CAT III, 1,000V, 6A Two Retractable Precision Grabbers, CAT III, 1,000V, 4A Two Retractable Grabbers, CAT III, 1,000V, 10A Two Retractable Hooks, CAT III, 1,000V, 10A Pouch | 63" | Black, Red | 18 | 0000000 | 000000 |
Test Leads
![]() | ![]() |
Sheathed 90° Standard Banana Plug | Sheathed Straight Standard Banana Plug |
Replace a test lead or complete a set with a red or black lead.
The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Test End | Connection End | Connection End Shape | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | No. of Cords | Cord Lg. | AWG | Test End Material | Cord Insulation Material | Choose a Color | Each | |||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Retractable Hook | Sheathed Standard Banana Plug | 90° Angle | 300 | 300 | 5 | CAT II, 300V | 1 | 48" | 18 | Gold-Plated Copper | Silicone Rubber | Black , Red | 0000000 | 000000 | ||
Retractable Hook | Sheathed Standard Banana Plug | Straight | 300 | 300 | 5 | CAT II, 300V | 1 | 48" | 18 | Gold-Plated Copper | Silicone Rubber | Black , Red | 0000000 | 00000 | ||
Test Leads with Reel
![]() |
Extend the distance between your multimeter and the equipment you’re testing.
One end of the test leads is a 4 mm banana plug, which is the standard for connecting to a multimeter. The other end is a 4 mm banana jack that attaches to test leads that have a 4 mm banana plug.
Cord Color | Connection End | Connection End Shape | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | AWG | Cord Insulation Material | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
40 ft. Long | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Black | Sheathed Standard Banana Plug x Sheathed Standard Banana Jack | 90° Angle x Straight | 1,000 | 1,000 | 20 | CAT III, 1,000V | 18 | Silicone Rubber | 00000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Red | Sheathed Standard Banana Plug x Sheathed Standard Banana Jack | 90° Angle x Straight | 1,000 | 1,000 | 20 | CAT III, 1,000V | 18 | Silicone Rubber | 00000000 | 00000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Test Lead Sets
![]() | ![]() | ![]() |
Style A | Style B | Style C |
![]() | ![]() | ![]() |
Style D | Style E | Style F |
Pairs of red and black test leads are ready to connect to a multimeter or other electrical test equipment.
The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter.
Style D—Style D come with alligator clips that screw onto the tips for two testing options with one test lead set.
Style | Test End | Connection End | AC Voltage, V AC | DC Voltage, V DC | Current, amp | Electrical Safety Rating | No. of Cords | Cord Lg. | Color | Test End Material | Pair | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A | Precision Retractable Hook | Sheathed Standard Banana Plug | 300 | 300 | 5 | CAT II, 300V | 2 | 48" | Black, Red | Gold-Plated Copper | 0000000 | 000000 | |
B | Precision Retractable Hook | Sheathed Standard Banana Plug | 300 | 300 | 5 | CAT II, 300V | 2 | 48" | Black, Red | Gold-Plated Copper | 0000000 | 00000 | |
C | Threaded Needle Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 20 | CAT II, 1,000V | 2 | 48" | Black, Red | Stainless Steel | 00000000 | 00000 | |
D | Threaded Needle Tip with Alligator Clip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 20 | CAT II, 300V | 2 | 44" | Black, Red | Stainless Steel | 0000000 | 00000 | |
E | Notched Probe Tip | Sheathed Standard Banana Plug | 1,000 | 1,000 | 10 | CAT II, 1,000V | 2 | 48" | Black, Red | Nickel-Plated Brass | 0000000 | 00000 | |
F | Precision Tweezer | Sheathed Standard Banana Plug | 30 | 60 | 3 | — | 2 | 48" | Black | Brass | 0000000 | 00000 |