Clamp Type Clamp Type |
---|
![]() | ![]() |
Dual Nut | Single Nut |
![]() | |
U Bolt |
For Wire Gauge For Wire Gauge |
---|
Material Material | Show |
---|
|
Material Material | Hide |
---|
Electrical Properties Electrical Properties |
---|
|
For Pipe Size For Pipe Size |
---|
|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
Electrical Connection Type Electrical Connection Type |
---|
![]() | Bolt |
For Pipe OD For Pipe OD |
---|
|
|
Type Type |
---|
![]() | ![]() |
Rope Clamp | Thimble |
Finish Finish |
---|
|
Capacity Capacity |
---|
|
|
Attachment Type Attachment Type |
---|
![]() | Loop |
For Wire Rope Construction For Wire Rope Construction |
---|
![]() | ![]() |
6 × 19 IWRC | 6 × 19 Fiber Core |
![]() | ![]() |
6 × 26 IWRC | 6 × 37 IWRC |
![]() | |
6 × 7 Fiber Core |
Grounding Rod Clamps
Connect bare-copper ground wire to grounding rods.
Dual nut clamps give you more flexibility than single nut clamps.
U-bolt clamps are the most adjustable and work with rods ranging in size from 3/8" to 1".
Two-piece design clamps are easier to install onto bends and continuous loops than other single- and dual-nut clamps.
For clamps with lay-in wire, there’s no need to thread wire through them. Simply lay the wire into the clamp’s opening and fasten.
UL 467 clamps meet a standard for direct burial.
For technical drawings and 3-D models, click on a part number.



For Rod Dia. (For Wire Gauge) | Material | Features | Specifications Met | Each | |
Single Nut | |||||
---|---|---|---|---|---|
1/2" (6, 5, 4, 3, 2, 1, 1/0, 10, 8, 7, 9) 5/8" (6, 5, 4, 3, 2, 1, 1/0, 10, 8, 7, 9) 3/4" (2, 1, 1/0, 3, 4, 5, 6, 7, 8) | Bronze | __ | UL 467 | 0000000 | 00000 |
1/2" (6, 4) 3/4" (6, 4) | Bronze | Two-Piece Design | __ | 0000000 | 00000 |
Dual Nut | |||||
1/4"-1" (10, 9, 8, 7, 6, 5, 4, 3, 2) | Bronze | Lay-In Wire, Two-Piece Design | __ | 0000000 | 00000 |
1/2" (6, 5, 4, 3, 2, 1, 1/0, 2/0, 3/0, 4/0, 250 MCM, 300 MCM, 350 MCM) 5/8" (6, 5, 4, 3, 2, 1, 1/0, 2/0, 3/0, 4/0, 250 MCM, 300 MCM, 350 MCM) 3/4" (2, 1, 1/0, 2/0, 3/0, 4/0, 250 MCM) | Bronze | __ | UL 467 | 0000000 | 00000 |
U Bolt | |||||
3/8"-1" (6, 5, 4, 3, 2, 1, 1/0, 2/0, 3/0, 4/0, 250 MCM, 300 MCM, 350 MCM, 400 MCM, 500 MCM) | Bronze | __ | UL 467 | 0000000 | 00000 |
Grounding Pipe Clamps


Attach grounding wire to pipes.
For Pipe | ||||||||
---|---|---|---|---|---|---|---|---|
For No. of Wires | Size | OD | For Wire Gauge | Material | Electrical Connection Type | Specifications Met | Each | |
1 | 1/2 to 1 | 1/2"-1 1/4" | 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2 | Bronze | Bolt | UL Listed | 0000000 | 000000 |
2 | 1 to 1 1/4 | 3/4"-1 11/16" | 6, 5, 4, 3, 2, 1, 1/0, 2/0, 3/0, 4/0, 250 MCM | Tin-Plated Bronze | Bolt | UL Listed | 0000000 | 00000 |
2 | 1 1/2 to 2 | 1"-2 3/8" | 6, 5, 4, 3, 2, 1, 1/0, 2/0, 3/0, 4/0, 250 MCM | Tin-Plated Bronze | Bolt | UL Listed | 0000000 | 00000 |
2 | 2 1/2 to 3 | 2 1/4"-3 1/2" | 6, 5, 4, 3, 2, 1, 1/0, 2/0, 3/0, 4/0, 250 MCM | Tin-Plated Bronze | Bolt | UL Listed | 0000000 | 00000 |
2 | 3 1/2 to 4 | 3 1/4"-4 1/2" | 6, 5, 4, 3, 2, 1, 1/0, 2/0, 3/0, 4/0, 250 MCM | Tin-Plated Bronze | Bolt | UL Listed | 0000000 | 00000 |
2 | 5 to 6 | 5 5/8"-6 5/8" | 6, 5, 4, 3, 2, 1, 1/0, 2/0, 3/0, 4/0, 250 MCM | Tin-Plated Bronze | Bolt | UL Listed | 0000000 | 00000 |
Grounding Plate Clamps

Eliminate the need to drive a new ground rod—these clamps connect grounding wire to an existing flat grounding surface, such as the lid of an electric meter box.
For Wire Gauge | For Max. Plate Thick. | Material | For No. of Wires | Electrical Connection Type | Specifications Met | Each | |
14, 13, 12, 11, 10, 9, 8, 7, 6 | 3/8" | Bronze | 1 | Bolt | UL Listed | 0000000 | 000000 |
Grounding Splices

Join two grounding wires to extend the length of your grounding connection or connect to an existing ground wire.
Grounding Screws

Connect grounding wires to steel structures, fence posts, and transformers. These screws can also tap one or two cables from a bus bar.
For technical drawings and 3-D models, click on a part number.
For Wire Gauge | Screw Size | Material | Specifications Met | Each | |
12, 11, 10, 9, 8 | 1/4" | Bronze | UL Listed, CSA Certified | 0000000 | 000000 |
10, 9, 8, 7, 6 | 1/4" | Bronze | UL Listed, CSA Certified | 0000000 | 00000 |
10, 9, 8, 7, 6, 5, 4 | 5/16" | Bronze | UL Listed, CSA Certified | 0000000 | 00000 |
10, 9, 8, 7, 6, 5, 4, 3, 2 | 3/8" | Bronze | UL Listed, CSA Certified | 0000000 | 00000 |
10, 9, 8, 7, 6, 5, 4, 3, 2, 1 | 3/8" | Bronze | UL Listed, CSA Certified | 0000000 | 00000 |
2, 1, 1/0, 2/0 | 1/2" | Bronze | UL Listed, CSA Certified | 0000000 | 00000 |
2, 1, 1/0, 2/0, 3/0 | 1/2" | Bronze | UL Listed, CSA Certified | 0000000 | 000000 |
1, 1/0, 2/0, 3/0, 4/0 | 5/8" | Bronze | UL Listed, CSA Certified | 0000000 | 000000 |
3/0, 4/0, 250 MCM, 300 MCM, 350 MCM, 400 MCM, 450 MCM, 500 MCM | 3/4" | Bronze | UL Listed, CSA Certified | 0000000 | 000000 |
Wire Rope Clamps with Thimbles—Not for Lifting



A clamp and thimble in one convenient fitting simplifies installation while providing support and fray protection to the wire rope loop. Use a torque wrench to tighten the clamp.
Warning: Test all assemblies for required strength before use. Do not use with coated rope unless the coating is removed.
Loop | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Wire Rope Dia. | Rope Turnback | For Wire Rope Construction | Inside Lg. | Inside Wd. | Overall Lg. | Fabrication | Required Torque, ft.-lbs. | Capacity, lbs. | Each | |
Bronze | ||||||||||
1/8" | 3 1/4" | 6 × 7 Fiber Core 6 × 19 IWRC 6 × 19 Fiber Core 6 × 26 IWRC 6 × 37 IWRC | 15/16" | 9/16" | 2 1/2" | Cast | 8 | 300 | 0000000 | 000000 |
3/16" | 3 3/4" | 6 × 7 Fiber Core 6 × 19 IWRC 6 × 19 Fiber Core 6 × 26 IWRC 6 × 37 IWRC | 1 1/8" | 21/32" | 2 7/8" | Cast | 12 | 600 | 0000000 | 00000 |
1/4" | 4 3/4" | 6 × 7 Fiber Core 6 × 19 IWRC 6 × 19 Fiber Core 6 × 26 IWRC 6 × 37 IWRC | 1 9/16" | 7/8" | 3 3/4" | Cast | 19 | 1,000 | 0000000 | 00000 |
5/16" | 5 1/4" | 6 × 7 Fiber Core 6 × 19 IWRC 6 × 19 Fiber Core 6 × 26 IWRC 6 × 37 IWRC | 1 15/16" | 1 1/16" | 4 5/8" | Cast | 19 | 1,600 | 0000000 | 00000 |