Gas Leak Detectors for Hard-to-Reach Areas

Identify a variety of small leaks quickly and access hard-to-reach areas with the flexible probe. An audible signal increases in intensity the closer you get to the leak. Intrinsically safe for Class I, Divisions I and 2, Groups A, B, C, and D hazardous locations.
Detection Trigger Point, ppm | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Methane (Natural Gas) | Propane | Hydrogen | Butane | Acetone | Methanol | Ammonia | Gasoline | Chlorine | Acetylene | Ethane | Ethylene | Hydrogen Sulfide | Batteries Included | Container Type | Each | |
5 | 5 | 5 | 5 | 50 | 50 | 20 | 1 | 1 | 50 | 5 | 500 | 5 | Yes | Plastic Carrying Case | 0000000 | 0000000 |
Economy Gas Leak Detectors
Check for leaks in pipes, valves, storage tanks, and other gas system components. Detector signals with both a red light and a continuous beeping sound.
Combustion Efficiency Meters
Also known as a combustion analyzer, this meter measures boiler and furnace combustion efficiency. It automatically calibrates to normal atmospheric oxygen.

Measurement Range | Calculated Range | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Use On | Ambient Temp. | Flue Gas Temp. | Flue Gas Oxygen | Carbon Monoxide, ppm | Combustion Efficiency | Carbon Dioxide | Air Free Carbon Monoxide, ppm | Excess Air | Accuracy | Batteries Included | Each | |
Kerosene, Natural Gas, Oil, Propane | 25° to 110° F | -4° to 1200° F | 0-20.9% | 0-2,000 | 0.1%-100% | 0-15% | 0-9,999 | 0-250% | ±0.3% of Oxygen Content | Yes | 0000000 | 0000000 |
Surface-Mount Multi-Gas Detectors

An audible alarm and warning light alert you to the presence of propane, methane, hydrogen, and carbon monoxide. This detector has a relay for connection to auxiliary alarm systems. A programmable timer allows you to set whether the relay alarm is triggered immediately, or after 4 or 8 minutes of continuous gas exposure. The reset button suspends the alarm and restarts the cycle for 5 to 8 minutes in case of false alarm.
Detects (Trigger Point) , ppm | Volume | Temperature Range, °F | Ht. | Wd. | Dp. | Voltage | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Each | |
Propane (420); Methane (5,000); Hydrogen (200); Carbon Monoxide (150) | 80 dB @ 10 ft. | -20° to 120° | 6 3/4" | 3 1/4" | 1 3/4" | 120V AC | 6 | No | 3/16" | 0000000 | 0000000 |
Portable Multi-Gas Detectors

When this detector senses high levels of combustible and toxic gases, it alerts you with an audible alarm, warning light, and vibrating alarm. You can adjust the alarm trigger points to suit your environment. There is also a motion sensor that sounds an alarm if the user becomes disabled.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator and cylinder (sold separately).
Note: LEL is lower explosive limit.
Detects (Measuring Range) | Volume | Temperature Range, °F | Batteries Included | Environmental Rating | Each | |
Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (0-100% LEL), Oxygen (0-30% Vol.), Carbon Monoxide (0-1,999 ppm), Hydrogen Sulfide (0-200 ppm) | 95 dBA @ 30 cm. | -40° to 140° | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA IP68 | 00000000 | 000000000 |
Portable Multi-Gas Detectors with Probe

Use the probe to test the air in a hazardous area before entering. Great for confined spaces. This detector alerts you with an audible alarm, warning light, and vibrating alarm in the presence of combustible and toxic gases. You can adjust the alarm trigger points to suit your environment. There is also a motion sensor that sounds an alarm if the user becomes disabled.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator and cylinder (sold separately).
Note: LEL is lower explosive limit.
Detects (Measuring Range) | Volume | Temperature Range, °F | Batteries Included | Includes | Tube Lg., ft. | Environmental Rating | Each | |
Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (0-100% LEL), Oxygen (0-30% Vol.), Carbon Monoxide (0-1,999 ppm), Hydrogen Sulfide (0-200 ppm) | 95 dBA @ 30 cm. | -40° to 140° | Yes | Sampling Probe, Tubing Assembly, Rechargeable Lithium Ion Battery for Probe | 25 | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEC Zone 0 Groups IIC, IIB, IIA IP68 | 00000000 | 000000000 |
Surface-Mount Hydrogen Detectors

An audible alarm and warning light alert you to the presence of hydrogen. This detector has a relay for connection to auxiliary alarm systems. A programmable timer allows you to set whether the relay alarm is triggered immediately, or after 4 or 8 minutes of continuous gas exposure. The reset button suspends the alarm and restarts the cycle for 5 to 8 minutes in case of false alarm.
Trigger Point, ppm | Volume | Temperature Range, ° F | Ht. | Wd. | Dp. | Voltage | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Each | |
8,000 | 80 dB @ 10 ft. | -20° to 120° | 6 3/4" | 3 1/4" | 1 3/4" | 120V AC | 6 | No | 3/16" | 0000000 | 0000000 |
Hydrogen Sulfide Detectors

When these detectors sense high levels of hydrogen sulfide, they alert you with an audible alarm, warning light, and vibrating alarm. You can adjust the alarm trigger point to suit your environment.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator, tubing, and cylinder (sold separately).
The detector with a nonreplaceable battery should be thrown away at the end of its two-year lifespan.
Measuring Range, ppm | Volume | Temperature Range, °F | Ht. | Wd. | Dp. | Batteries Included | Environmental Rating | Each | |
Detectors with Nonreplaceable Battery | |||||||||
---|---|---|---|---|---|---|---|---|---|
0-100 | 95 dBA @ 30 cm. | -4° to 122° | 3 1/2" | 2" | 1" | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IP67 | 00000000 | 0000000 |
Detectors with Replaceable Battery | |||||||||
0-200 | 95 dBA @ 30 cm. | 14° to 104° | 3 1/2" | 2" | 1" | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 IEC Zone 0 Groups IIC, IIB, IIA IP67 | 00000000 | 000000 |
Propane Detectors

An audible alarm and warning light alert you to the presence of propane. This detector has a relay for connection to auxiliary alarm systems. A programmable timer allows you to set whether the relay alarm is triggered immediately, or after 4 or 8 minutes of continuous gas exposure. The reset button suspends the alarm and restarts the cycle for 5 to 8 minutes in case of false alarm.
Trigger Point, ppm | Volume | Temperature Range, ° F | Ht. | Wd. | Dp. | Voltage | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Each | |
4,200 | 80 dB @ 10 ft. | -20° to 120° | 6 3/4" | 3 1/4" | 1 3/4" | 120V AC | 6 | No | 3/16" | 0000000 | 0000000 |
Methane Detectors

An audible alarm and warning light alert you to the presence of methane. This detector has a relay for connection to auxiliary alarm systems. A programmable timer allows you to set whether the relay alarm is triggered immediately, or after 4 or 8 minutes of continuous gas exposure. The reset button suspends the alarm and restarts the cycle for 5 to 8 minutes in case of false alarm.
Trigger Point, ppm | Volume | Temperature Range, ° F | Ht. | Wd. | Dp. | Voltage | Cord Lg., ft. | Fasteners Included | Mounting Hole Dia. | Each | |
10,000 | 80 dB @ 10 ft. | -20° to 120° | 6 3/4" | 3 1/4" | 1 3/4" | 120V AC | 6 | No | 3/16" | 0000000 | 0000000 |
Oxygen Detectors

When your work area has too much or too little oxygen, these detectors alert you with an audible alarm, warning light, and vibrating alarm. You can adjust the high and low alarm trigger points to suit your environment.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check can be performed with the press of a button.
The detector with a nonreplaceable battery should be thrown away at the end of its two-year lifespan.
Measuring Range, % Vol. | Volume | Ht. | Wd. | Dp. | Temperature Range, °F | Batteries Included | Battery Chemistry | Environmental Rating | Each | |
Detectors with Nonreplaceable Battery | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
0-25 | 95 dBA @ 30 cm. | 3 1/2" | 2" | 1" | -4° to 122° | Yes | Lithium | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IP67 | 00000000 | 0000000 |
Detectors with Replaceable Battery | ||||||||||
0-25 | 95 dBA @ 30 cm. | 3 1/2" | 2" | 1" | -4° to 122° | Yes | Lithium | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 0 Groups IIC, IIB, IIA | 00000000 | 000000 |
Batteries (Pkg. of 1) | 0000000 | Pkg. | 000000 |
Portable Carbon Monoxide Detectors

When these detectors sense high levels of carbon monoxide, they alert you with an audible alarm, warning light, and vibrating alarm. You can adjust the alarm trigger point to suit your environment.
A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator, tubing, and cylinder (sold separately).
The detector with a nonreplaceable battery should be thrown away at the end of its two-year lifespan.
Measuring Range, ppm | Volume | Temperature Range, °F | Ht. | Wd. | Dp. | Batteries Included | Environmental Rating | Each | |
Detectors with Nonreplaceable Battery | |||||||||
---|---|---|---|---|---|---|---|---|---|
0-500 | 95 dBA @ 30 cm. | -4° to 122° | 3 1/2" | 2" | 1" | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Group G NEC Zone 0 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA IP67 | 00000000 | 0000000 |
Detectors with Replaceable Battery | |||||||||
0-2,000 | 95 dBA @ 30 cm. | 14° to 104° | 3 1/2" | 2" | 1" | Yes | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 IEC Zone 0 Groups IIC, IIB, IIA IP67 | 00000000 | 000000 |