McMaster-Carr logo
    Filter by
    Power Source
    System of Measurement
    Electrical Connection
    Methane (Natural Gas) Detection Trigger Point
    Propane Detection Trigger Point
    Butane Detection Trigger Point
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    39 Products

    Gas Leak Detectors for Hard-to-Reach Areas

    Image of Product. Front orientation. Gas Leak Detectors. Gas Leak Detectors for Hard-to-Reach Areas.
    Identify a variety of small leaks quickly and access hard-to-reach areas with the flexible probe. An audible alert increases in intensity the closer you get to the leak. Intrinsically safe for Class I, Divisions I and 2, Groups A, B, C, and D hazardous locations.
    Cannot Be Sold Outside North America—Product regulations restrict sales to the listed areas.
    Detection Trigger Point, ppm
    Methane (Natural
    Gas)
    Propane
    Hydrogen
    Butane
    Acetone
    Methanol
    Ammonia
    Gasoline
    Chlorine
    Acetylene
    Ethane
    Ethylene
    Hydrogen
    Sulfide
    Batteries
    Included
    Container Type
    Cannot Be Sold To
    Each
    5555505020115055005YesPlastic Carrying CaseOutside North America1140T140000000
    Replacements for Gas Leak Detectors

    Combustion Analyzers

    Image of Product. Front orientation. Combustion Analyzers.
    These analyzers measure boiler and furnace combustion efficiency. They automatically calibrate to normal atmospheric oxygen.
    Measurement Range
    Calculated Range
    For Use On
    Ambient Temp.,
    ° F
    Flue Gas Temp.,
    ° F
    Flue Gas
    Oxygen
    Carbon Monoxide,
    ppm
    Combustion
    Efficiency
    Carbon
    Dioxide
    Air Free Carbon
    Monoxide, ppm
    Excess
    Air
    Accuracy
    Batteries
    Included
    Each
    Kerosene, Natural Gas, Oil, Propane25 to 110-4 to 1,2000% to 20.9%0 to 2,0000.1% to 100%0% to 15%0 to 9,9990% to 250%±0.3% of Oxygen ContentYes3937K350000000
    Replacements for Combustion Analyzers

    Surface-Mount Multi-Gas Detectors

    Image of Product. Front orientation. Multi-Gas Detectors. Surface-Mount Multi-Gas Detectors.
    An audible alarm and warning light alert you to the presence of propane, methane, hydrogen, and carbon monoxide. These detectors have a relay for connection to auxiliary alarm systems. A programmable timer allows you to set whether the relay alarm is triggered immediately, or after 4 or 8 minutes of continuous gas exposure. The reset button suspends the alarm and restarts the cycle for 5 to 8 minutes in case of false alarm.
    Cannot Be Sold To—Import regulations restrict sales to the listed areas.
    Detects (Trigger Point)
    Volume (Sound)
    @ Distance
    Temp. Range,
    ° F
    Ht.
    Wd.
    Dp.
    Voltage,
    V AC
    Cord Lg.,
    ft.
    Fasteners
    Included
    Mounting
    Hole Dia.
    Cannot Be
    Sold To
    Each
    Propane (420 ppm); Methane (5,000 ppm); Hydrogen (200 ppm); Carbon Monoxide (150 ppm)80 dB @ 10 ft.-20 to 1206 3/4"3 1/4"1 3/4"1206No3/16"Canada6631T180000000

    Methane Detectors

    Image of Product. Front orientation. Methane Detectors.
    An audible alarm and warning light alert personnel to methane, so they can evacuate or take corrective action. A relay connects to auxiliary alarm systems to trigger building-wide alerts or automated ventilation shutoffs. A programmable timer controls when the relay triggers. Choose immediate activation or a delay of 4 or 8 minutes of continuous exposure. This helps reduce false alarms in environments with brief, transient gas releases. A reset button silences nuisance alarms and restarts the detection cycle for 5 to 8 minutes.
    Cannot Be Sold To—Import regulations restrict sales to the listed areas.
    Trigger
    Point, ppm
    Volume (Sound)
    @ Distance
    Temp.,
    ° F
    Ht.
    Wd.
    Dp.
    Voltage,
    V AC
    Cord Lg.,
    ft.
    Fasteners
    Included
    Mounting
    Hole Dia.
    Cannot Be
    Sold To
    Each
    10,00080 dB @ 10 ft.-20 to 1206 3/4"3 1/4"1 3/4"1206No3/16"Canada6631T430000000

    Portable Multi-Gas Detectors with Probe

    Image of Product. Front orientation. Multi-Gas Detectors. Portable Multi-Gas Detectors with Probe.
    Use the probe on these detectors to test the air in a hazardous area before entering. Great for confined spaces. Detectors alert you with an audible alarm, warning light, and vibrating alarm in the presence of combustible and toxic gases. You can adjust the alarm trigger points to suit your environment. There is also a motion sensor that sounds an alarm if the user becomes disabled.
    A calibration check must be performed on these detectors before each use to verify that they are working properly. The check requires a regulator and cylinder (sold separately).
    Note: LEL is lower explosive limit.
    Detects (Measuring Range)
    Volume (Sound)
    @ Distance
    Temp. Range,
    ° F
    Batteries
    Included
    Includes
    Tube Lg.,
    ft.
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (Methylbenzene) (0% to 100% LEL)
    Oxygen (0% to 30% Vol.)
    Carbon Monoxide (0 ppm to 1,999 ppm)
    Hydrogen Sulfide (0 ppm to 200 ppm)
    95 dBA @ 30 cm-40 to 140YesSampling Probe, Tubing Assembly, Battery25NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 0 Groups IIC, IIB, IIA
    AEx Da Ia IIC T4 Ga
    Ex Da Ia IIC T4 Ga
    IP68
    18995T44000000000
    Accessories and Replacements for Multi-Gas Detectors

    Surface-Mount Hydrogen Detectors

    Image of Product. Front orientation. Hydrogen Detectors. Surface-Mount Hydrogen Detectors.
    An audible alarm and warning light alert you to the presence of hydrogen. This detector has a relay for connection to auxiliary alarm systems. A programmable timer allows you to set whether the relay alarm is triggered immediately, or after 4 or 8 minutes of continuous gas exposure. The reset button suspends the alarm and restarts the cycle for 5 to 8 minutes in case of false alarm.
    Cannot Be Sold To—Import regulations restrict sales to the listed areas.
    Electrical
    Trigger
    Point, ppm
    Volume (Sound)
    @ Distance
    Temp. Range,
    ° F
    Ht.
    Wd.
    Dp.
    Connection
    No. of
    Blades
    Voltage,
    V AC
    Cord Lg.,
    ft.
    Fasteners
    Included
    Mounting
    Hole Dia.
    Cannot Be
    Sold To
    Each
    8,00080 dB @ 10 ft.-20 to 1206 3/4"3 1/4"1 3/4"Straight Blade21206No3/16"Canada6631T420000000

    Economy Gas Leak Detectors

    Image of Product. Front orientation. Gas Leak Detectors. Economy Gas Leak Detectors.
    Check for combustible gas leaks in equipment such as pipes, valves, and storage tanks. When these detectors sense combustible gas, they alert you with a warning light and a continuous beeping sound. Unlike our other gas leak detectors, these are compact and can fit in your pocket. However, they only detect combustible gas, not toxic gas.
    Static Absorption Detector—Static absorption detectors also indicate the presence of static that could ignite flammable gases or vapors. To ensure strong charges aren’t present, test for static absorption before entering an area to test for gas leaks.
    Detectors
    Replacement
    Batteries
    Detection
    Trigger Point, ppm
    Methane (Natural
    Gas)
    Propane
    Butane
    Dia.
    Lg.
    Wt.,
    oz.
    Gas Leak Detected
    Batteries
    Included
    Features
    Each
    Pkg.
    Qty.
    Pkg.
    10,00010,00010,0001 1/4"7 1/2"4Butane, Methane, PropaneYesWrist Strap1076T8000000471455K5300000
    1,0005007/8"7"1Methane, PropaneYesPocket Clip, Static Absorption Detector, Wrist Strap1076T1100000471455K620000

    Acoustic Imaging Gas Leak Detectors

    Image of Product. Front orientation. ZoomedIn view. Contains Inset, Border. Gas Leak Detectors. Acoustic Imaging Gas Leak Detectors.
    Locate leaks up to 10 times faster than traditional leak-detecting methods. These detectors use 124 microphones to determine the precise location and size of leaks in compressed air and specific gas systems. The screen displays a high-resolution acoustic image that’s overlaid on a digital live shot of your facility to help you visualize the leak. It also displays analytics related to the leak, such as the rate and the potential cost savings of patching your system. You can capture the on-screen view through photos and video to review later. With a built-in flashlight, they remain accurate even in low-light spaces. Light enough to carry with one hand, you can bring these detectors on the go. A 650 ft. range means you can use them from one end of your facility to another, or to detect in hard-to-reach systems.
    Connect the detector to your computer using Wi-Fi or the included USB cable to quickly transfer collected data.
    Max. Working
    Distance, ft.
    Freq. Measured
    Range, kHz
    Diag. Screen
    Size
    Directional
    Resolution Range
    Data
    Connection
    Wt.,
    lb.
    Housing
    Material
    Temp. Range,
    ° F
    Enclosure
    Rating
    Gas Leak Detected
    Batteries
    Included
    Container Type
    Includes
    Features
    Each
    6502 to 1305"1°-0.125°Wi-Fi, USB-A3.2Plastic0 to 120IP54
    Ammonia, Argon, Carbon Dioxide, Helium, Hydrogen, Methane, Compressed Gas LeakYesPlastic Carrying CaseBattery Charger, Charging Cord, Lanyard, USB DriveMemory Storage, LED Flashlight7203N120000000000
    Replacements for Gas Leak Detectors

    Portable Multi-Gas Detectors

    Image of Product. Front orientation. Multi-Gas Detectors. Portable Multi-Gas Detectors.
    When these detectors sense high levels of combustible and toxic gases, they alert you with an audible alarm, warning light, and vibrating alarm. You can adjust the alarm trigger points to suit your environment. There is also a motion sensor that sounds an alarm if the user becomes disabled.
    A calibration check must be performed on detectors before each use to verify that they are working properly. The check requires a regulator and cylinder (sold separately).
    Note: LEL is lower explosive limit.
    Detects (Measuring Range)
    Volume (Sound)
    @ Distance
    Temp. Range,
    ° F
    Batteries
    Included
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    Acetone, Butane, Hydrogen, Methane, Pentane, Propane, Toluene (Methylbenzene) (0% to 100% LEL)
    Oxygen (0% to 30% Vol.)
    Carbon Monoxide (0 ppm to 1,999 ppm)
    Hydrogen Sulfide (0 ppm to 200 ppm)
    95 dBA @ 30 cm-40 to 140YesNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    NEC Zone 0 Groups IIC, IIB, IIA
    AEx Da Ia IIC T4 Ga
    Ex Da Ia IIC T4 Ga
    IP68
    18995T42000000000
    Accessories for Multi-Gas Detectors

    Air Filter Monitors for Supplied-Air Respirators for Plant Air Lines

    Track the quality of incoming air as it travels from your air line to your respirator. These monitors display air-quality data, including carbon monoxide and water vapor levels, and sound an alarm if the air is unsafe to breathe. They also filter the air three times before it reaches you to remove oil, water, and solid particles.
    Monitors with Low-Battery Alarm
    Image of Product. Closed. Front orientation. Respirator Filter Monitors. Air Filter Monitors for Supplied-Air Respirators for Plant Air Lines, Monitors with Low-Battery Alarm, 1/2.
    Image of Product. Open. Front orientation. Respirator Filter Monitors. Air Filter Monitors for Supplied-Air Respirators for Plant Air Lines, Monitors with Low-Battery Alarm, 1/2.

    Closed

    Open

    Respirator Filter Monitor Calibration Kits—Calibration kits (sold separately) come with everything you need to test the accuracy of the filter monitor, including a regulator, tubing, and fittings. The components are packed in a carrying case. Air filter monitors should be calibrated monthly to ensure they’re working properly.
    Respirator Filter Monitors
    Respirator Filter
    Monitor Calibration Kits
    Replacement
    Filters
    Overall
    For Use With
    Inlet Coupling
    Size
    Outlet Coupling
    Size
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Pressure Regulation
    Range, psi
    Regulating
    Accuracy
    Wd.
    Ht.
    Max. Temp.,
    ° F
    Battery
    Type
    Batteries
    Included
    Battery
    Size
    No. of Batteries
    Req.
    Cord Lg.,
    ft.
    Each
    Each
    Each
    Plastic Housing
     
    Quick-Disconnect Male Inlet × Quick-Disconnect Female Outlet
    Solid Particles, Oil, Water1/21/415 ft³/min @ 100 psi1500 to 160±1 psi19"13"120DisposableNoAA8106793N170000000006793N1300000006793N120000000
     
    Monitors with Data Logging Capabilities and Low-Battery Alarm
    Image of Product. Closed. Front orientation. Respirator Filter Monitors. Air Filter Monitors for Supplied-Air Respirators for Plant Air Lines, Monitors with Data Logging Capabilities and Low-Battery Alarm.
    Image of Product. Open. Front orientation. Respirator Filter Monitors. Air Filter Monitors for Supplied-Air Respirators for Plant Air Lines, Monitors with Data Logging Capabilities and Low-Battery Alarm.

    Closed

    Open

    Monitors with data-logging capabilities record air-quality data and calibration results onto a removable USB drive. Download your data from the USB for compliance reports and recordkeeping. They have a large color screen to easily view the quality and status of air as it flows through the filter. When it is time to calibrate the filter monitor, the screen gives clear, step-by-step instructions.
    Respirator Filter Monitor Calibration Kits—Calibration kits (sold separately) come with everything you need to test the accuracy of the filter monitor, including a regulator, tubing, and fittings. The components are packed in a carrying case. Air filter monitors should be calibrated monthly to ensure they’re working properly.
    Respirator Filter Monitors
    Respirator Filter
    Monitor Calibration Kits
    Replacement
    Filters
    Overall
    For Use With
    Inlet Coupling
    Size
    Outlet Coupling
    Size
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Pressure Regulation
    Range, psi
    Regulating
    Accuracy
    Wd.
    Ht.
    Max. Temp.,
    ° F
    Battery
    Type
    Batteries
    Included
    No. of Batteries
    Req.
    Cord Lg.,
    ft.
    Each
    Each
    Each
    Plastic Housing
     
    Quick-Disconnect Male Inlet × Quick-Disconnect Female Outlet
    Solid Particles, Oil, Water1/41/415 ft³/min @ 100 psi1500 to 160±1 psi18 1/2"13"100RechargeableYes176793N140000000006793N1500000006793N160000000
     

    Oxygen Detectors

    Image of Product. Front orientation. Oxygen Detectors.
    When your work area has too much or too little oxygen, these detectors alert you with an audible alarm, warning light, and vibrating alarm. You can adjust the high and low alarm trigger points to suit your environment.
    A calibration check must be performed on the detector before each use to verify that it is working properly. The check can be performed with the press of a button.
    Detectors with Nonreplaceable Battery—The detector with a nonreplaceable battery should be thrown away at the end of its two-year lifespan.
    Oxygen Detectors
    Batteries
    Oxygen Volume Percent
    Concentration Measured
    Volume (Sound)
    @ Distance
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Batteries
    Included
    Battery
    Chemistry
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    Pkg.
    Qty.
    Pkg.
    Detectors with Nonreplaceable Battery
    0% to 25%95 dBA @ 30 cm3 1/2"2"1"-4 to 122YesLithiumNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Group G
    NEC Zone 0 Groups IIC, IIB, IIA
    IEC Zone 1 Groups IIC, IIB, IIA
    AEx Ia IIC T4
    ATEX II 2 G Ex Ia IIC T4 Gb
    IECEx Ex Ia IIC T4
    IP67
    18995T810000000———0
     
    Detectors with Replaceable Battery
    0% to 25%95 dBA @ 30 cm3 1/2"2"1"-4 to 122YesLithiumNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Group G
    NEC Zone 0 Groups IIC, IIB, IIA
    IEC Zone 0 Groups IIC, IIB, IIA
    AEx Ia IIC T4
    ATEX II 1 G Ex Ia IIC T4 Ga
    ATEX II 2 G Ex Ia IIC T4 Gb
    IECEx Ex Ia IIC T4
    18995T9200000017821K7200000
     

    Propane Detectors

    Image of Product. Front orientation. Propane Detectors.
    An audible alarm and warning light alert you to the presence of propane. These detectors have a relay for connection to auxiliary alarm systems. A programmable timer allows you to set whether the relay alarm is triggered immediately, or after 4 or 8 minutes of continuous gas exposure. The reset button suspends the alarm and restarts the cycle for 5 to 8 minutes in case of false alarm.
    Cannot Be Sold To—Import regulations restrict sales to the listed areas.
    Trigger
    Point, ppm
    Volume (Sound)
    @ Distance
    Temp. Range,
    ° F
    Ht.
    Wd.
    Dp.
    Voltage,
    V AC
    Cord Lg.,
    ft.
    Fasteners
    Included
    Mounting
    Hole Dia.
    Cannot Be
    Sold To
    Each
    4,20080 dB @ 10 ft.-20 to 1206 3/4"3 1/4"1 3/4"1206No3/16"Canada6631T410000000

    Hydrogen Sulfide Detectors

    Image of Product. Front orientation. Hydrogen Sulfide Detectors.
    When these detectors sense high levels of hydrogen sulfide, they alert you with an audible alarm, warning light, and vibrating alarm. You can adjust the alarm trigger point to suit your environment.
    A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator, tubing, and cylinder (sold separately).
    Nonreplaceable Batteries—The detector with a nonreplaceable battery should be thrown away at the end of its two-year lifespan.
    Hydrogen Sulfide Concentration
    Measured, ppm
    Volume (Sound)
    @ Distance
    Temp. Range,
    ° F
    Ht.
    Wd.
    Dp.
    Batteries
    Included
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    Nonreplaceable Batteries
    0 to 10095 dBA @ 30 cm-4 to 1223 1/2"2"1"YesNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Group G
    NEC Zone 0 Groups IIC, IIB, IIA
    IEC Zone 1 Groups IIC, IIB, IIA
    IECEx Ex Ia IIC T4
    AEx Ia IIC T4
    ATEX II 2 G Ex Ia IIC T4 Gb
    IP67
    18995T850000000
     
    Replaceable Batteries
    0 to 20095 dBA @ 30 cm14 to 1043 1/2"2"1"YesNEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    IEC Zone 0 Groups IIC, IIB, IIA
    IECEx Ex Ia IIC T4 Ga
    ATEX II 1 G Ex Ia IIC T4 Ga
    IP67
    18995T19000000
     
    Accessories for Hydrogen Sulfide Detectors

    Portable Carbon Monoxide Detectors

    Image of Product. Front orientation. Carbon Monoxide Detectors. Portable Carbon Monoxide Detectors.
    When these detectors sense high levels of carbon monoxide, they alert you with an audible alarm, warning light, and vibrating alarm. You can adjust the alarm trigger point to suit your environment.
    A calibration check must be performed on the detector before each use to verify that it is working properly. The check requires a regulator, tubing, and cylinder (sold separately).
    Nonreplaceable Batteries—The detector with a nonreplaceable battery should be thrown away at the end of its two-year lifespan.
    Carbon Monoxide Concentration
    Measured, ppm
    Volume (Sound)
    @ Distance
    Temp.,
    ° F
    Ht.
    Wd.
    Dp.
    Batteries
    Included
    Certification
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    Nonreplaceable Batteries
    0 to 50095 dBA @ 30 cm-4 to 1223 1/2"2"1"YesCSA-US Certified
    CSA Certified
    CE Marked
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Group G
    NEC Zone 0 Groups IIC, IIB, IIA
    IEC Zone 1 Groups IIC, IIB, IIA
    IECEx Ex Ia IIC T4
    ATEX II 2 G Ex Ia IIC T4 Gb
    AEx Ia IIC T4
    IP67
    18995T830000000
     
    Replaceable Batteries
    0 to 2,00095 dBA @ 30 cm14 to 1043 1/2"2"1"YesCSA-US Certified
    CSA Certified
    CE Marked
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEC Class III Divisions 1, 2
    IEC Zone 0 Groups IIC, IIB, IIA
    IECEx Ex Ia IIC T4 Ga
    ATEX II 1 G Ex Ia IIC T4 Ga
    IP67
    18995T15000000
     
    Accessories and Replacements for Carbon Monoxide Detectors
    back to top