About Sump, Water-Removal, Condensate, and Submersible Pumps
More
How to Prime Your Pump
More
How to Determine Feet of Head
More
Impact-Resistant Submersible/Open-Air Pumps for Water
![](/prerenderstable/mvPRE/contents/gfx/imagecache/418/4182k26p1-c01a-digital@halfx_636899910934114223.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/418/4182k2p1-c01a-digital@halfx_636899894220763877.png?ver=imagenotfound)
Protected from impact by a durable epoxy-coated aluminum housing, these pumps can be submerged or connected remotely to a pipe in your line. Use to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Hardwire pumps must be wired to a plug (not included).
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Features | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug | |||||||||||||||||||
A | 3.4 | 2 | __ | 7.4 | 35° to 120° | 1/150 hp | 1.1 | 1/4 × 1/2 | NPT × NPT | Female × Male | 1/4 | NPT | Male | 4 1/8" | 4 1/8" | 4 5/8" | __ | 0000000 | 0000000 |
B | 5 | 3.4 | 1.2 | 11.8 | 35° to 120° | 1/40 hp | 1.7 | 3/8 | NPT | Female | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | Removable Intake Screen | 000000 | 000000 |
B | 8.3 | 5.6 | 3.5 | 17.3 | 35° to 120° | 1/15 hp | 3.2 | 1/2 | NPT | Female | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | Removable Intake Screen | 000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
B | 5 | 3.4 | 1.2 | 11.8 | 35° to 120° | 1/40 hp | 0.7 | 3/8 | NPT | Female | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | Removable Intake Screen | 0000000 | 000000 |
B | 10 | 8.6 | 6.9 | 21 | 35° to 120° | 1/15 hp | 1.4 | 1/2 | NPT | Female | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | Removable Intake Screen | 0000000 | 000000 |
Impact-Resistant Submersible Pumps for Water
![](/prerenderstable/mvPRE/contents/gfx/imagecache/418/4182k24p1-c01a-digital@halfx_636969763035445113.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/418/4182k2p1-c01a-digital@halfx_636899894220763877.png?ver=imagenotfound)
The durable epoxy-coated aluminum housing handles hard knocks in rough waters. Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Hardwire pumps must be wired to a plug (not included).
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Plug | ||||||||||||||||
A | 2.8 | 1.7 | __ | 7 | 35° to 120° | 1/200 hp | 1.1 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 1/8" | 4 1/8" | 0000000 | 0000000 |
B | 5 | 3.4 | 1.2 | 11.8 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | 000000 | 000000 |
B | 13.5 | 12.4 | 10.2 | 24.5 | 35° to 120° | 1/12 hp | 3.5 | Screened | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | 000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
A | 3.4 | 2 | __ | 7.4 | 35° to 120° | 1/150 hp | 0.4 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 1/8" | 4 1/8" | 0000000 | 000000 |
B | 13.5 | 12.4 | 10.2 | 24.5 | 35° to 120° | 1/12 hp | 1.6 | Screened | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | 0000000 | 000000 |
Submersible Pumps for Water
![](/prerenderstable/mvPRE/contents/gfx/imagecache/418/4182k22p1-c01a-digital@halfx_636969749933497878.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/316/3163k32-@halfx_1707241758.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/998/9988k76p1-c01a-digital@halfx_636899927279834480.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/418/4182k37p1-c01a-digital@halfx_636969753187733535.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/316/3163k311-@halfx_637655745308496081.png?ver=imagenotfound)
Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Hardwire pumps must be wired to a plug (not included).
![](/prerenderstable/mvPRE/contents/gfx/imagecache/418/4182k22p1-c01a-digital@halfx_636969749933497878.png?ver=imagenotfound)
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
A | Plug | 2.8 | 1.7 | __ | 7 | 35° to 120° | 1/125 hp | 0.6 | Screened | 1/4 | NPT | Male | 6 | 3 5/8" | 2 7/8" | 3 1/2" | 0000000 | 0000000 |
A | Plug | 5 | 4 | 2.2 | 12.2 | 35° to 120° | 1/40 hp | 0.8 | Screened | 1/4 | NPT | Male | 6 | 4 1/4" | 2 7/8" | 4 7/8" | 0000000 | 000000 |
![](/prerenderstable/mvPRE/contents/gfx/imagecache/316/3163k32-@halfx_1707241758.png?ver=imagenotfound)
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
B | Plug | 5.6 | 4.3 | 0.8 | 11.1 | 35° to 85° | 1/15 hp | 0.8 | Screened | 1/4 | NPT | Male | 6 | 4" | 3 7/8" | 5 3/8" | 0000000 | 000000 |
B | Plug | 8.9 | 6.9 | 2.5 | 13 | 35° to 85° | 1/10 hp | 1.2 | Screened | 1/2 | NPT | Male | 6 | 4 1/2" | 4" | 5 5/8" | 0000000 | 00000 |
115V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||||||
B | Plug | 3.5 | 1.5 | __ | 7.1 | 35° to 85° | 1/25 hp | 0.5 | Screened | 1/4 | NPT | Male | 6 | 3 7/8" | 3 1/2" | 4 5/8" | 0000000 | 00000 |
![](/prerenderstable/mvPRE/contents/gfx/imagecache/998/9988k76p1-c01a-digital@halfx_636899927279834480.png?ver=imagenotfound)
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
C | Plug | 3.5 | 2.5 | __ | 10.2 | 35° to 120° | 1/150 hp | 1.1 | Screened | 1/4 | NPT | Male | 6 | 4 5/8" | 4 1/8" | 4 1/8" | 0000000 | 0000000 |
C | Plug | 5.4 | 4.5 | 2.2 | 12.3 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 6 | 4 5/8" | 5" | 5" | 0000000 | 000000 |
C | Plug | 5.4 | 4.5 | 2.2 | 12.3 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 18 | 4 5/8" | 5" | 5" | 0000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
C | Hardwire | 5.4 | 4.5 | 2.2 | 12.3 | 35° to 120° | 1/40 hp | 0.7 | Screened | 1/4 | NPT | Male | 12 | 4 5/8" | 5" | 5" | 0000000 | 000000 |
![](/prerenderstable/mvPRE/contents/gfx/imagecache/418/4182k37p1-c01a-digital@halfx_636969753187733535.png?ver=imagenotfound)
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
D | Plug | 7.9 | 6.6 | 3.4 | 13.4 | 35° to 120° | 1/28 hp | 1.4 | Screened | 3/8 | NPT | Male | 6 | 4" | 4" | 4 5/8" | 0000000 | 0000000 |
![](/prerenderstable/mvPRE/contents/gfx/imagecache/316/3163k311-@halfx_637655745308496081.png?ver=imagenotfound)
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
E | Plug | 20 | 12 | 4 | 15 | 35° to 85° | 1/15 hp | 1 | Screened | 3/4 | NPT | Male | 15 | 5 1/4" | 3 3/4" | 6 3/8" | 00000000 | 0000000 |
Submersible/Open-Air Pumps for Water
![](/prerenderstable/mvPRE/contents/gfx/imagecache/418/4182k25p1-@halfx_637208283928821399.png?ver=imagenotfound)
These pumps can be submerged or connected remotely to a pipe in your line. Use them to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Max. Flow Rate, gpm | Intake | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Plug | ||||||||||||||||
2.8 | 1.7 | 7 | 35° to 120° | 1/125 hp | 0.6 | 1/4 × 1/2 | NPT × NPT | Female × Male | 1/4 | NPT | Male | 3 3/8" | 3 3/4" | 2 3/4" | 0000000 | 0000000 |
Extended-Life Submersible Pumps for Water
![](/prerenderstable/mvPRE/contents/gfx/imagecache/997/9971k41p1-@halfx_637209026792818128.png?ver=imagenotfound)
Magnets turn the impeller so there's no shaft seal to wear out. Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry.
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 0 Ft. of Head | @ 1 Ft. of Head | @ 3 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||||
Plug | ||||||||||||||||
3 | 2.6 | 1.8 | 4.6 | 3" | 35° to 160° | 1/200 hp | 0.5 | Screened | 1/4 | NPT | Male | 3 1/4" | 3 3/4" | 3 7/8" | 0000000 | 0000000 |
Extended-Life Submersible/Open-Air Pumps for Water
![](/prerenderstable/mvPRE/contents/gfx/imagecache/997/9971k21p1-@halfx_637209026431618687.png?ver=imagenotfound)
These pumps can be submerged or connected remotely to a pipe in your line. Magnets turn the impeller so there's no shaft seal to wear out. Use to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 0 Ft. of Head | @ 1 Ft. of Head | @ 3 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Tube Connection Type | For Tube ID | Tube Connection Type | For Tube ID | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||
Plug | 2.3 | 2 | 1.5 | 4.6 | 3" | 35° to 160° | 1/200 hp | 0.5 | Barbed | 3/8" | Barbed | 3/8" | 3 1/4" | 3 3/4" | 4 1/2" | 0000000 | 0000000 |
Plug | 3 | 2.6 | 1.8 | 4.6 | 3" | 35° to 160° | 1/200 hp | 0.5 | Barbed | 1/2" | Barbed | 1/2" | 3 1/4" | 3 3/4" | 4 1/2" | 0000000 | 000000 |
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Connection Type | @ 0 Ft. of Head | @ 1 Ft. of Head | @ 3 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||||
Plug | 3 | 2.6 | 1.8 | 4.6 | 3" | 35° to 160° | 1/200 hp | 0.5 | 1/4 | NPT | Male | 1/4 | NPT | Male | 3 1/4" | 3 3/4" | 4 1/2" | 0000000 | 0000000 |
High-Head Submersible Pumps for Water
![](/prerenderstable/mvPRE/contents/gfx/imagecache/350/3501n21_fc265d4f-b61a-4875-9665-7a8d830ff465@halfx_1677610632.png?ver=imagenotfound)
Also known as deep-well submersible pumps, use these pumps to transfer drinking water from wells and cisterns up to 250 ft. deep. They are activated by a pressure switch and must be hardwired. Do not run dry.
For technical drawings and 3-D models, click on a part number.
Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Ft. of Head, ft. | Removes Water Down To, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Ht. | Specifications Met | Each | |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||
Hardwire | ||||||||||||||
14.7 | 309.5 | 250 | 68° to 104° | 1 7/16 hp | 13.1 | Screened | 1 1/4 | NPT | Female | 3 15/16" | 31 3/8" | NSF/ANSI 61, UL Listed | 0000000 | 000000000 |
16.4 | 223.5 | 250 | 68° to 104° | 1 1/2 hp | 13.1 | Screened | 1 1/2 | NPT | Female | 3 15/16" | 27 3/16" | NSF/ANSI 61, UL Listed | 0000000 | 00000000 |
Submersible Pumps for Cutting Oil
![](/prerenderstable/mvPRE/contents/gfx/imagecache/419/4191k21p1-@halfx_637208287582154268.png?ver=imagenotfound)
Submerge these pumps to circulate machine and cutting oil with a viscosity up to 9 centipoise. Plug in to activate. Do not run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 3 Ft. of Head | @ 5 Ft. of Head | @ 7 Ft. of Head | Max. Ft. of Head, ft. | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug | |||||||||||||||||||
5 | 4.3 | 3.4 | 2.5 | 11.8 | 9 | 35° to 120° | 1/40 hp | 1.7 | 3/8 | NPT | Female | 1/4 | NPT | Male | 4 5/8" | 3 1/2" | 5 3/4" | 0000000 | 0000000 |
Submersible Pumps for Chemicals
![](/prerenderstable/mvPRE/contents/gfx/imagecache/998/9987k77p1-c01a-digital@halfx_636899912287980976.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/998/9987k67p1-c01a-digital@halfx_636899910346364885.png?ver=imagenotfound)
These pumps circulate solvent-based parts-washing solutions. Submerge in solutions that are UL classified as PJQU (flash point no lower than 100° F). Pumps must be wired to a plug (not included) to activate. Do not run dry. Not for use in heated parts washer applications.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 3 Ft. of Head | @ 5 Ft. of Head | @ 7 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
A | 5 | 4.3 | 3.4 | 2.5 | 11.8 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | 0000000 | 0000000 |
B | 3.4 | 2.8 | 2 | 0.3 | 7.4 | 35° to 120° | 1/150 hp | 1.1 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 5/8" | 4 1/8" | 0000000 | 000000 |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
A | 2.8 | 2.3 | 1.7 | __ | 7 | 35° to 120° | 1/125 hp | 0.6 | Screened | 1/4 | NPT | Male | 3 5/8" | 2 3/4" | 3 1/4" | 0000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Hardwire | |||||||||||||||||
B | 3.4 | 2.8 | 2 | 0.3 | 7.4 | 35° to 120° | 1/150 hp | 0.6 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 5/8" | 4 1/8" | 0000000 | 000000 |
Submersible Pumps for Salt Water
![](/prerenderstable/mvPRE/contents/gfx/imagecache/998/99845k48p1-c01a-digital@halfx_636899906347862070.png?ver=imagenotfound)
Circulate salt water in submerged and open-air applications. These pumps use magnets to turn the impellers so there is no shaft seal to wear out. They must be wired to a plug (not included) to activate. Do not run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 1 Ft. of Head | @ 5 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
5 | 3.8 | 13 | 35° to 130° | 1/50 hp | 0.9 | 3/8 × 3/4 | NPT × NPT | Female × Male | 1/4 | NPT | Male | 4 1/8" | 6 1/8" | 4 7/8" | 00000000 | 0000000 |
8.5 | 8 | 19 | 35° to 130° | 1/20 hp | 2 | 3/4 | NPT | Female | 1/2 | NPT | Male | 4 7/8" | 7 3/8" | 4 3/4" | 00000000 | 000000 |