About Air Preparation
More
Space-Saving Compressed Air Filter/Regulator Manifolds

Minimize the footprint of your air preparation system with these all-in-one manifolds—they include a filter, a regulator, a slow-start valve, and a safety lockout valve. Use them to distribute clean, compressed air to up to four locations. Three regulated outlets provide air at the same set pressure, and one unregulated outlet provides high-pressure air for blow guns and other tools. All controls are on the front panel, so you don’t need clearance above or below these manifolds to make adjustments. Since the inlet and outlet ports swivel until tightened, you can connect to your air line without rotating the manifold.
The filter removes both particles and water, and it has an indicator to let you know when the filter element needs to be replaced. The regulator is relieving, so it will exhaust when the downstream pressure exceeds the set pressure. To protect sensitive components from hard starts and surges, the slow-start air-exhaust valve eases pressure into your system. The safety lockout valve keeps the system from starting up during maintenance—lock it with the included padlock and key.
These manifolds are rated IP65 for protection from dust and low-pressure jets of water. When the 1/4 NPT outlets are not in use, cover them with the included threaded plugs to maintain this rating.
Manifolds that operate on 24V DC have LEDs that indicate if the pressure is above or below your set pressure and if the air supply is on or off. They are ATEX certified for use in hazardous locations.
Filter/Regulator Manifolds | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Filter Elements | |||||||||||||
| Inlet Pipe Size | Outlet Pipe Size (No. of Outlets) | Voltage | Max. Flow Rate | Pressure Regulating Range, psi | Max. Pressure, psi | Max. Temp., °F | Removes Particle Size Down To, microns | Environmental Rating | Wd. | Ht. | Each | Each | ||
NPT Female Inlet and Outlet | ||||||||||||||
Clear Bowl with Automatic Drain | ||||||||||||||
| 3/8 | 3/8 (1 Regulated), 1/4 (1 Unregulated), 1/4 (2 Regulated) | __ | 120 scfm @ 100 psi | 0-120 | 145 | 120° | 5 | IP65 | 7" | 5 3/4" | 8628T1 | 0000000 | 8628T21 | 000000 |
| 3/8 | 3/8 (1 Regulated), 1/4 (1 Unregulated), 1/4 (2 Regulated) | 24V DC | 120 scfm @ 100 psi | 0-120 | 145 | 120° | 5 | IEC Zone 2 Groups IIC, IIB, IIA IP65 | 7" | 5 3/4" | 8628T11 | 000000 | 8628T21 | 00000 |
| 1/2 | 1/2 (1 Regulated), 1/4 (1 Unregulated), 1/4 (2 Regulated) | __ | 145 scfm @ 100 psi | 0-120 | 145 | 120° | 5 | IP65 | 7" | 5 3/4" | 8628T2 | 000000 | 8628T21 | 00000 |
| 1/2 | 1/2 (1 Regulated), 1/4 (1 Unregulated), 1/4 (2 Regulated) | 24V DC | 145 scfm @ 100 psi | 0-120 | 145 | 120° | 5 | IEC Zone 2 Groups IIC, IIB, IIA IP65 | 7" | 5 3/4" | 8628T12 | 000000 | 8628T21 | 00000 |