About Air Preparation
More
Norgren Modular Compressed Air Regulator Manifolds

Connect two or more of these manifold regulators to meet multiple pressure requirements from a single air supply—set a different output pressure with each regulator. Each regulator has two regulated outlets and one unregulated outlet. Regulators are relieving style, so they exhaust when the downstream pressure exceeds the set pressure. Install in your air line after filters.
Mounting brackets (sold separately) allow you to attach manifold regulators to a wall or equipment.
Joiner clamps (sold separately) connect manifold regulators to each other and other Norgren modular components with the same series number. They come with mounting brackets.
End block sets (sold separately) allow you to swap out filter/regulator/lubricator components without unthreading your air line connections. The blocks remain connected to your pipe while you replace components between them.
Regulator Manifolds | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Joiner Clamps | End Block Sets | ||||||||||||
| Manufacturer Series | Inlet Pipe Size | Outlet Pipe Size (No. of Outlets) | Max. Flow Rate | Max. Pressure, psi | Wd. | Ht. | Max. Temp., °F | Pressure Regulating Range, psi | Each | Each | Each | |||
Aluminum Housing | ||||||||||||||
Series No. 74—NPT Female Inlet and Outlets | ||||||||||||||
| R74 | 1/2 | 1/2 (1 Unregulated), 1/2 (1 Regulated), 1/8 (1 Regulated) | 160 scfm @ 100 psi | 300 | 3 1/8" | 6 5/8" | 175° | 5-150 | 00000000 | 0000000 | 000000 | 000000 | 0000000 | 000000 |
| Mounting Bracket for Series No. 74 Regulator Manifolds | 0000000 | Each | 000000 |
Wilkerson Modular Compressed Air Regulator Manifolds

Connect two or more of these manifold regulators to meet multiple pressure requirements from a single air supply—set a different output pressure with each regulator. Each regulator has two regulated outlets, one unregulated outlet, and an additional port that can be used for a pressure gauge. Regulators are relieving style, so they exhaust when the downstream pressure exceeds the set pressure. Install in your air line after filters.
Joiner clamps (sold separately) connect manifold regulators to each other and other Wilkerson modular components with the same series number. They come with mounting brackets to attach the regulator to a wall or equipment.
End block sets (sold separately) allow you to swap out filter/regulator/lubricator components without unthreading your air line connections. The blocks remain connected to your pipe while you replace components between them.
Gauges are not included with Series No. 19 manifold regulators.
Regulator Manifolds | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Joiner Clamps | End Block Sets | |||||||||||||
| Manufacturer Series | Inlet Pipe Size | Outlet Pipe Size (No. of Outlets) | Max. Flow Rate | Max. Pressure, psi | Gauge Included | Wd. | Ht. | Max. Temp., °F | Choose a Pressure Regulating Range, psi | Each | Each | Each | |||
Aluminum Housing | |||||||||||||||
Series No. 19—NPT Female Inlet and Outlets | |||||||||||||||
| R19 | 1/2 | 1/2 (1 Unregulated), 1/4 (2 Regulated) | 62 scfm @ 100 psi | 300 | No | 2 3/8" | 5 1/2" | 150° | 0000000 | 000000 | 00000000 | 000000 | 00000000 | 000000 | |
| R19 | 1/2 | 1/2 (1 Unregulated), 1/4 (2 Regulated) | 82 scfm @ 48 psi | 300 | No | 2 3/8" | 5 1/2" | 150° | 0-60 | 00000000 | 00000 | 00000000 | 00000 | 00000000 | 00000 |
| R19 | 1/2 | 1/2 (1 Unregulated), 1/4 (2 Regulated) | 132 scfm @ 100 psi | 300 | No | 2 3/8" | 5 1/2" | 150° | 0-250 | 00000000 | 00000 | 00000000 | 00000 | 00000000 | 00000 |
Compressed Air Regulating Manifolds


Use a single air supply to meet the pressure requirements of multiple applications—connect one of these manifolds to your air line, and then set a different output pressure for each station. All are relieving regulators, so they exhaust when the downstream pressure exceeds the set pressure. Install in your air line after filters.
Style B manifolds are designed for assembly lines, packaging machinery, and other general industrial applications.
Style C manifolds are suitable in the high-pressure systems required for sandblasting, molding and machining operations, and conveying.
Pipe Size | Overall | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Gauge Included | Wd. | Ht. | Housing Material | Max. Temp., °F | Regulating Accuracy | Pressure Regulating Range, psi | Each | ||
NPT Female Inlet and Outlet | |||||||||||||
2 Stations | |||||||||||||
| B | 1/2 | 3/8 | 141 scfm @ 100 psi | 145 | Yes | 5 3/4" | 5" | Aluminum | 140° | ±4 psi | 8-123 psi | 0000000 | 0000000 |
| C | 1/2 | 1/2 | 230 scfm @ 100 psi | 290 | Yes | 6 1/4" | 7 3/8" | Aluminum | 140° | ±7 psi | 4.4-174 psi | 0000000 | 000000 |
4 Stations | |||||||||||||
| B | 1/2 | 3/8 | 141 scfm @ 100 psi | 145 | Yes | 11 5/8" | 5" | Aluminum | 140° | ±4 psi | 8-123 psi | 0000000 | 000000 |
| C | 1/2 | 1/2 | 230 scfm @ 100 psi | 290 | Yes | 12 3/8" | 7 3/8" | Aluminum | 140° | ±7 psi | 4.4-174 psi | 0000000 | 000000 |
6 Stations | |||||||||||||
| B | 1/2 | 3/8 | 141 scfm @ 100 psi | 145 | Yes | 17 1/2" | 5" | Aluminum | 140° | ±4 psi | 8-123 psi | 0000000 | 000000 |
| C | 1/2 | 1/2 | 230 scfm @ 100 psi | 290 | Yes | 18 5/8" | 7 3/8" | Aluminum | 140° | ±7 psi | 4.4-174 psi | 0000000 | 000000 |
8 Stations | |||||||||||||
| B | 1/2 | 3/8 | 141 scfm @ 100 psi | 145 | Yes | 23 1/2" | 5" | Aluminum | 140° | ±4 psi | 8-123 psi | 0000000 | 000000 |
| C | 1/2 | 1/2 | 230 scfm @ 100 psi | 290 | Yes | 24 3/4" | 7 3/8" | Aluminum | 140° | ±7 psi | 4.4-174 psi | 0000000 | 000000 |
Manifold Blocks for Parker Modular Compressed
Air Filter/Regulator/Lubricators (FRLs)

Distribute compressed air to multiple locations from a single source. These manifolds connect with Parker modular components that have the same manufacturer series.
Use joiner clamps to connect the manifold block to another Parker modular unit with the same series number.
Compressed Air Filter/Regulator Manifolds

Use a single air supply to distribute air to up to four locations. In addition to the outlet for inline connection, these manifolds have three 1/4 NPT female outlets for connection to air-powered tools and equipment. The outlet for inline connection and two of the 1/4 NPT outlets are regulated and will all have the same set pressure. The third 1/4 NPT outlet is unregulated for use with high-pressure applications, such as with a compressed air gun. Cover the 1/4 NPT outlets with the included threaded plugs when not in use. All outlets are filtered.
Manifolds have an integral slow-start valve that slowly increases pressure to your system to prevent surge damage. They also have a shut-off valve with padlock and key. A filter removes particles and a regulator allows you to adjust and maintain the pressure of your compressed air. Regulator is relieving style so the regulated outlets exhaust when the downstream pressure exceeds the set pressure. Housing meets IP65 for protection from dust and water spray.
Manifolds that operate on 24V DC have LEDs that indicate if the pressure is above or below your set pressure and if the air supply is on or off. They are ATEX Certified for use in hazardous locations.
Filter/Regulator Manifolds | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Filter Elements | |||||||||||||
| Inlet Pipe Size | Outlet Pipe Size (No. of Outlets) | Voltage | Max. Flow Rate | Pressure Regulating Range, psi | Max. Pressure, psi | Max. Temp., °F | Removes Particle Size Down To, microns | Environmental Rating | Wd. | Ht. | Each | Each | ||
NPT Female Inlet and Outlet | ||||||||||||||
Clear Bowl with Automatic Drain | ||||||||||||||
| 1/2 | 1/2 (1 Regulated), 1/4 (1 Unregulated), 1/4 (2 Regulated) | __ | 145 scfm @ 100 psi | 0-120 | 145 | 120° | 5 | IP65 | 7" | 5 3/4" | 000000 | 0000000 | 0000000 | 000000 |
| 1/2 | 1/2 (1 Regulated), 1/4 (1 Unregulated), 1/4 (2 Regulated) | 24V DC | 145 scfm @ 100 psi | 0-120 | 145 | 120° | 5 | IEC Zone 2 Groups IIC, IIB, IIA IP65 | 7" | 5 3/4" | 0000000 | 000000 | 0000000 | 00000 |