We will reply to your message within an hour.
More
Prevent equipment damage caused by moisture. The first step in water removal, these separators remove the water that accumulates as compressed air cools.
In addition to removing large amounts of water, these separators also remove particles and oil droplets. Place them after your compressor and aftercooler, or at the point of use in applications that don't require an aftercooler.
Extend the service life of air-powered tools and equipment by removing particles and water droplets from compressed air.
Extend the service life of air-powered tools and equipment by removing particles and water droplets from compressed air. Joiner clamps connect these air filters into your Parker setup.
Assembled, inspected, and packaged in a clean environment, these filters come sealed in antistatic double bags.
Get two stages of filtration—the first stage removes most particles and water droplets; the second captures any remaining particles and water droplets down to 5 microns.
Mount these filters to a 35 mm DIN rail with the included brackets.
Use these filters where high water and dirt removal is needed—they have a two-layer filter element made of stainless steel wire mesh and cotton/polyester packing.
Protect small air-powered tools, such as impact wrenches, ratchet wrenches, grinders, and screwdrivers.
No need to buy and service two filters—these filters have a single element that removes both oil and particles.
Two-stage filtration is like getting two filters in one—the first stage removes large particles, while the second removes fine particles.
Also known as coalescing filters, these filters remove compressor oil to extend the service life of air-powered tools and equipment.
Designed for use in main lines with high contamination, these filters remove oil to extend the service life of air-powered tools and equipment.
Use these filters in applications where high-quality air is critical. They remove particles down to 0.003 microns, eliminating small traces of oil vapor and its associated odor.
Produce clean air for instrumentation and other applications, such as food or medical device manufacturing.
Often used in medical device manufacturing and food-processing facilities, these filters have a stainless steel element that can be sterilized in an autoclave.
A filter and regulator joined top-to-bottom, these filter/regulators fit in the same space as a filter alone.
These filter/regulator combinations come as one convenient unit that cleans the air as it regulates pressure.
No need for thread adapters—these filter/regulators have an NPT inlet and a BSPP outlet.
Mount these filter/regulators to a 35 mm DIN rail with the included brackets.
Assembled, inspected, and packaged in a clean environment, these filter/regulators come sealed in antistatic double bags.
Use a single air supply to distribute air to up to four locations. In addition to the outlet for inline connection, these manifolds have three 1/4 NPT female outlets for connection to air-powered tools and equipment.
A Norgren filter, regulator, and lubricator are combined to provide clean, lubricated compressed air at your required pressure.
An ARO filter, regulator, and lubricator are combined to provide clean, lubricated compressed air at your required pressure.
A filter, regulator, and lubricator are combined to provide clean, lubricated compressed air at your required pressure.
A Festo filter, regulator, and lubricator are combined to provide clean, lubricated compressed air at your required pressure.
A Wilkerson filter, regulator, and lubricator are combined to provide clean, lubricated compressed air at your required pressure.
An ASCO Numatics filter, regulator, and lubricator are combined to provide clean, lubricated compressed air at your required pressure.
With one outlet port before the lubricator and one after, these filter/regulator/lubricators work in systems that require lubrication in some lines but not in others.
No need for thread adapters—these filter/regulator/lubricators have an NPT inlet and a BSPP outlet.
Filter and lubricator in one, these filter/lubricators provide clean, lubricated compressed air to extend the service life of tools and equipment.
Distribute compressed air to multiple locations from a single source.
Each of these filter/dryers has two desiccant towers—one that absorbs moisture, particles, and oil in the air while the other reactivates saturated desiccant so you have an uninterrupted supply of clean, dry compressed air.
For use with Norgren modular compressed air systems, once aftercoolers and separators have removed the bulk of the water, use one of these desiccant-filled dryers to remove any remaining moisture in your air line.
Once aftercoolers and separators have removed the bulk of the water, use these dryers to remove any remaining moisture in your air line.
Get dry compressed air in high-pressure systems—these dryers have a maximum pressure rating of 300 psi. Once aftercoolers and separators have removed the bulk of the water, they remove any remaining moisture in your air line.