About Exhaust Fans
More
About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
Corrosion-Resistant Portable Blowers

A plastic housing offers good corrosion resistance. These blowers are powerful enough for use with flexible duct, yet light enough to carry from job to job. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. Blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments. They are stackable for increased airflow and storage.
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Airflow @ Duct Lg. | Volume | Motor Speed, rpm | Power, hp | For Duct Dia. | Ht. | Wd. | Dp. | Plug Type | Cord Lg., ft. | Temp. Range, °F | Housing Material | Blade Material | Each | |
120V AC, Single Phase—Plug | |||||||||||||||
875 | 480 cfm @ 50 ft. | 70 dB @ 15 ft. | 3,200 | 1/4 | 8" | 18 1/2" | 12 1/2" | 18 1/2" | Three Prong | 20 | -20° to 150° | Polyethylene Plastic | Polypropylene Plastic | 00000000 | 0000000 |
2,000 | 1,600 cfm @ 50 ft. | 80 dB @ 15 ft. | 3,425 | 1 | 12" | 21" | 14" | 17" | Three Prong | 20 | -20° to 150° | Polyethylene Plastic | Polypropylene Plastic | 00000000 | 000000 |
Portable Blowers

Powerful enough for use with flexible duct, yet light enough to carry from job to job. Use these blowers for equipment cooling, material conveying, drying, ventilating, and exhausting. Blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Motor Speed, rpm | Power, hp | For Duct Dia. | Ht. | Wd. | Dp. | Plug Type | Cord Lg., ft. | Temp. Range, °F | Housing Material | Blade Material | Each | |
120V AC, Single Phase—Plug | ||||||||||||||
775 | 70 dBA @ 15 ft. | 3,200 | 1/3 | 8" | 10" | 8" | 12" | Three Prong | 6 | -10° to 150° | Powder-Coated Steel | Polypropylene Plastic | 000000 | 0000000 |
1,700 | 80 dBA @ 15 ft. | 3,200 | 1/3 | 12" | 15" | 12" | 15 1/2" | Three Prong | 20 | -10° to 150° | Powder-Coated Steel | Polypropylene Plastic | 000000 | 000000 |
Hazardous Location High-Output Portable Blowers

In addition to blowing twice as much air as other portable blowers, these have an explosion-proof motor that is UL listed for Class I, Divisions 1 and 2, Group D; and Class II, Divisions 1 and 2, Groups E, F, and G hazardous locations. They are powerful enough for use with flexible duct, yet light enough to carry from job to job. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. They rest on the floor with their built-in base or can be mounted on an optional stand (sold separately).
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Airflow @ Duct Lg. | Volume | Motor Speed, rpm | Power, hp | For Duct Dia. | Wd. | Dp. | Temp. Range, °F | Housing Material | Blade Material | Environmental Rating | Each | |
120V AC, Single Phase—Hardwire | |||||||||||||
1,500 | 1,000 cfm @ 50 ft. | 80 dBA @ 15 ft. | 3,450 | 3/4 | 8" | 11 3/8" | 39" | -15° to 125° | Aluminum | ABS Plastic | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 NEMA 9 | 0000000 | 000000000 |
3,000 | 2,300 cfm @ 50 ft. | 85 dBA @ 15 ft. | 3,450 | 1 | 12" | 13 1/4" | 36" | -15° to 125° | Aluminum | Aluminum | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 NEMA 9 | 0000000 | 00000000 |
230V AC, Single Phase—Hardwire | |||||||||||||
3,000 | 2,300 cfm @ 50 ft. | 85 dBA @ 15 ft. | 3,450 | 1 | 12" | 13 1/4" | 36" | -15° to 125° | Aluminum | Aluminum | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 NEMA 9 | 0000000 | 00000000 |
Optional 26" Stand | 0000000 | Each | 0000000 |
High-Output Portable Blowers

Blow twice as much air as other portable blowers. These are powerful enough for use with flexible duct, yet light enough to carry from job to job. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments. They rest on the floor with their built-in base or can be mounted on an optional stand (sold separately).
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Airflow @ Duct Lg. | Volume | Motor Speed, rpm | Power, hp | For Duct Dia. | Ht. | Wd. | Dp. | Plug Type | Temp. Range, °F | Housing Material | Blade Material | Each | |
120V AC, Single Phase—Plug | ||||||||||||||
1,500 | 1,000 cfm @ 50 ft. | 80 dBA @ 15 ft. | 3,450 | 3/4 | 8" | 13 3/4" | 11 3/8" | 39" | Three Prong | -15° to 125° | Aluminum | ABS Plastic | 0000000 | 000000000 |
3,000 | 2,300 cfm @ 50 ft. | 85 dBA @ 15 ft. | 3,450 | 1 | 12" | 15 5/8" | 13 1/4" | 36" | Three Prong | -15° to 125° | Aluminum | Aluminum | 0000000 | 00000000 |
230V AC, Single Phase—Hardwire, Plug | ||||||||||||||
3,000 | 2,300 cfm @ 50 ft. | 85 dBA @ 15 ft. | 3,450 | 1 | 12" | 15 5/8" | 13 1/4" | 36" | __ | -15° to 125° | Aluminum | Aluminum | 0000000 | 00000000 |
Optional 26" Stand | 0000000 | Each | 0000000 |
Air-Powered Portable Blowers

Use your compressed air source to power these blowers. They are powerful enough for use with flexible duct, yet light enough to carry from job to job. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting.
Note: Airflow is based on an air supply of 80 psi.
For technical drawings and 3-D models, click on a part number.
Blowers | Duct | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Airflow @ Duct Lg. | Volume | Air Consumption, cfm | Max. Air Pressure, psi | Air Inlet Pipe Size | For Duct Dia. | O'all Dp. | Base Dia. | Temp. Range, °F | Housing Material | Mount. Fasteners Included | Each | Each | ||
NPT Female Air Inlet | |||||||||||||||
With Galvanized Steel Diffuser | |||||||||||||||
1,000 | 600 cfm @ 50 ft. | 70 dBA @ 5 ft. | 50 | 150 | 1/2 | 6" | 16 3/4" | 7 5/16" | -15° to 350° | Aluminum | No | 0000000 | 0000000 | 0000000 | 0000000 |
7,300 | 4,000 cfm @ 50 ft. | 80 dBA @ 5 ft. | 380 | 150 | 1 | 16" | 48" | 17" | -15° to 350° | Aluminum | No | 0000000 | 00000000 | 0000000 | 000000 |
With Powder-Coated Steel Diffuser | |||||||||||||||
1,500 | Not Rated | 80 dBA @ 15 ft. | 60 | 150 | 1/2 | 6" | 16 1/2" | 7 1/2" | -15° to 350° | Aluminum | No | 0000000 | 000000 | 0000000 | 000000 |
1,700 | 1,350 cfm @ 50 ft. | 80 dBA @ 15 ft. | 60 | 150 | 1/2 | 8" | 33" | 7 1/2" | -15° to 350° | Aluminum | No | 0000000 | 000000 | 0000000 | 000000 |
4,500 | 3,580 cfm @ 50 ft. | 85 dBA @ 15 ft. | 125 | 150 | 1 | 12" | 44 1/4" | 11 1/2" | -15° to 350° | Aluminum | No | 0000000 | 00000000 | 0000000 | 000000 |
With Plastic Diffuser | |||||||||||||||
1,500 | Not Rated | 80 dBA @ 15 ft. | 60 | 150 | 1/2 | 6" | 16 1/2" | 7 1/2" | -15° to 160° | Aluminum | No | 0000000 | 000000 | 0000000 | 000000 |
1,700 | 1,350 cfm @ 50 ft. | 80 dBA @ 15 ft. | 60 | 150 | 1/2 | 8" | 33" | 7 1/2" | -15° to 160° | Aluminum | No | 0000000 | 000000 | 0000000 | 000000 |
4,500 | 3,580 cfm @ 50 ft. | 85 dBA @ 15 ft. | 125 | 150 | 1 | 12" | 44 1/4" | 11 1/2" | -15° to 160° | Aluminum | No | 0000000 | 00000000 | 0000000 | 000000 |
Direct-Drive Wall-Mount Exhaust Fans

Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have an open dripproof motor enclosure for relatively clean, dry, indoor locations.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.
Fans | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Collars | |||||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Max. Ambient Temperature | Frame Material | Blade Material | Specifications Met | Each | Each | ||
120V AC, Single Phase—Hardwire | ||||||||||||||||
12" | 1,500 | 60 dBA @ 5 ft. | 1,550 | 1 | 1/8 | 16 1/8" | 16 1/8" | 8" | 105° F | Steel | Aluminum | UL Listed | 0000000 | 0000000 | 0000000 | 0000000 |
20" | 4,100 | 64 dBA @ 5 ft. | 1,075 | 1 | 1/2 | 24 1/8" | 24 1/8" | 10 5/8" | 105° F | Steel | Aluminum | UL Listed | 0000000 | 000000 | 0000000 | 000000 |
24" | 6,600 | 67 dBA @ 5 ft. | 1,075 | 1 | 3/4 | 30 1/8" | 30 1/8" | 11 1/8" | 105° F | Steel | Aluminum | UL Listed | 0000000 | 000000 | 0000000 | 000000 |
Window-Mount Office Fans

Draw fresh air in or push stale air out of your windows. Reverse airflow with the flip of a switch. Side panels expand to fit the width of your window.
Overall | Blade | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | No. of Speeds | Current, A | Ht. | Wd. | Dp. | Cord Lg., ft. | Housing Material | Material | Rotation | Guard Material | Specifications Met | Each | |
120V AC, Single Phase—Three Prong Plug | ||||||||||||||
Non-Oscillating | ||||||||||||||
20" | 3,500 | 3 | 1.4 | 26" | 27"-38" | 10" | 7 | Plastic | Steel | Reversible | Steel | ETL Listed | 0000000 | 0000000 |
Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers

These light duty fans are designed for use without duct. They come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
For technical drawings and 3-D models, click on a part number.
For Opening | Overall | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Ht. | Wd. | Dp. | Max. Ambient Temperature | Control Type | Frame Material | Blade Material | Mount. Fasteners Included | Mount. Hole Dia. | Specifications Met | Each | |
120V AC, Single Phase—Hardwire | ||||||||||||||||||
10" | 680 | 1,560 | 3 | 1/12 | 10 1/2" | 10 1/2" | 13" | 13" | 8 1/8" | 100° F | Pull Switch | Steel | Aluminum | No | 1/4" | UL Recognized Component | 00000000 | 0000000 |
12" | 825 | 1,560 | 3 | 1/12 | 12 1/2" | 12 1/2" | 15" | 15" | 9 1/2" | 100° F | Pull Switch | Steel | Aluminum | No | 1/4" | UL Recognized Component | 00000000 | 000000 |
16" | 2,100 | 1,660 | 3 | 1/8 | 16 1/2" | 16 1/2" | 19" | 19" | 9 1/2" | 100° F | Pull Switch | Steel | Aluminum | No | 1/4" | UL Recognized Component | 00000000 | 000000 |
18" | 2,300 | 1,660 | 3 | 1/8 | 18 1/2" | 18 1/2" | 21" | 21" | 9 1/2" | 100° F | Pull Switch | Steel | Aluminum | No | 1/4" | UL Recognized Component | 00000000 | 000000 |
20" | 2,925 | 1,140 | 2 | 1/4 | 20" | 20" | 23" | 23" | 9 1/2" | 100° F | Pull Switch | Steel | Aluminum | No | 1/4" | UL Recognized Component | 00000000 | 000000 |
24" | 3,400 | 1,140 | 2 | 1/4 | 24 1/2" | 24 1/2" | 27" | 27" | 9 1/2" | 100° F | Pull Switch | Steel | Aluminum | No | 1/4" | UL Recognized Component | 00000000 | 000000 |
30" | 3,950 | 1,140 | 2 | 1/4 | 30 1/2" | 30 1/2" | 33" | 33" | 9 1/2" | 100° F | Pull Switch | Steel | Aluminum | No | 1/4" | UL Recognized Component | 00000000 | 000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||||||
24" | 3,950 | 1,720 | Variable | 1/2 | 24 1/2" | 24 1/2" | 28" | 28" | 17" | 100° F | Knob, On-Off Switch | Steel | Aluminum | No | 1/4" | UL Recognized Component | 00000000 | 000000 |
Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans


Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.
Fans | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Collars | |||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Frame Material | Blade Material | Each | Each | ||
230/460V AC, Three Phase—Hardwire | ||||||||||||||
36" | 14,200 | 68 dB @ 5 ft. | 800 | 1 | 1 1/2 | 42" | 42" | 19 1/8" | Steel | Steel | 0000000 | 000000000 | 0000000 | 0000000 |
48" | 26,800 | 72 dB @ 5 ft. | 600 | 1 | 3 | 54" | 54" | 24 7/8" | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
54" | 37,600 | 70 dB @ 5 ft. | 525 | 1 | 5 | 60" | 60" | 23 1/2" | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
60" | 50,000 | 79 dB @ 5 ft. | 500 | 1 | 7 1/2 | 66" | 66" | 23 1/2" | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
Belt-Drive Wall-Mount Exhaust Fans
Use these fans to draw stagnant and humid air out of a room or area. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. All have an open dripproof motor enclosure for relatively clean, dry, indoor locations.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.


Fans | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Collars | |||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Frame Material | Blade Material | Each | Each | ||
120V AC, Single Phase—Hardwire | ||||||||||||||
30" | 8,200 | 56 dB @ 5 ft. | 600 | 1 | 1/2 | 36" | 36" | 18 3/8" | Steel | Steel | 0000000 | 0000000 | 0000000 | 0000000 |
36" | 10,600 | 56 dB @ 5 ft. | 425 | 1 | 1/2 | 42" | 42" | 18 5/8" | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
48" | 18,500 | 61 dB @ 5 ft. | 400 | 1 | 1 | 54" | 54" | 24 3/4" | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||
30" | 8,200 | 56 dB @ 5 ft. | 600 | 1 | 1/2 | 36" | 36" | 18 3/8" | Steel | Steel | 0000000 | 000000 | 0000000 | 000000 |
36" | 10,600 | 56 dB @ 5 ft. | 425 | 1 | 1/2 | 42" | 42" | 18 5/8" | Steel | Steel | 0000000 | 000000 | 0000000 | 000000 |
48" | 18,500 | 56 dB @ 5 ft. | 400 | 1 | 1 | 54" | 54" | 24 3/4" | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans





Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.
Fans | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Collars | |||||||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Wt., lbs. | Max. Ambient Temperature | Frame Material | Blade Material | Specifications Met | Each | Each | |||
120V AC, Single Phase—Hardwire | ||||||||||||||||||
1 | 8" | 520 | Not Rated | 3,125 | 1 | 1/10 | 12 1/4" | 12 1/4" | 3 1/8" | 8 | 149° F | Steel | Steel | UL Recognized Component | 000000 | 0000000 | 000000 | 00 |
1 | 10" | 1,000 | Not Rated | 2,650 | 1 | 1/4 | 14 5/8" | 14 5/8" | 3 1/4" | 12 | Not Rated | Steel | Steel | UL Recognized Component | 000000 | 000000 | 000000 | 00 |
1 | 12" | 1,500 | Not Rated | 2,850 | 1 | 1/4 | 17" | 17" | 3 3/4" | 14 | Not Rated | Steel | Steel | UL Recognized Component | 000000 | 000000 | 000000 | 00 |
1 | 14" | 1,800 | Not Rated | 1,525 | 1 | 1/4 | 19" | 19" | 4 1/8" | 18 | 77° F | Steel | Steel | UL Recognized Component | 000000 | 000000 | 000000 | 00 |
2 | 17" | 3,300 | Not Rated | 1,650 | 1 | 3/8 | __ | 21 3/8" Dia. | 6 1/2" | 33 | Not Rated | Steel | Steel | UL Recognized Component | 000000 | 000000 | 000000 | 00 |
3 | 8" | 400 | 34 dBA @ 15 ft. | 1,550 | 1 | 1/30 | 13" | 13" | 6 5/8" | 15 | 104° F | Steel | Aluminum | __ | 0000000 | 000000 | 000000 | 00 |
3 | 10" | 600 | 42 dBA @ 15 ft. | 1,550 | 1 | 1/40 | 13" | 13" | 6 5/8" | 14 | 104° F | Steel | Aluminum | __ | 0000000 | 000000 | 000000 | 00 |
3 | 12" | 825 | Not Rated | 1,560 | 3 | 1/12 | 14 1/2" | 14 1/2" | 9 1/4" | 14 | 100° F | Steel | Aluminum | UL Recognized Component | 0000000 | 000000 | 000000 | 00 |
3 | 12" | 1,300 | 40 dBA @ 15 ft. | 1,650 | 1 | 1/4 | 20" | 20" | 7 7/8" | 29 | 104° F | Steel | Aluminum | __ | 0000000 | 000000 | 0000000 | 0000000 |
3 | 16" | 2,100 | Not Rated | 1,660 | 3 | 1/8 | 19 1/8" | 19 1/8" | 10 1/8" | 21 | 100° F | Steel | Aluminum | UL Recognized Component | 0000000 | 000000 | 000000 | 00 |
3 | 16" | 2,900 | 49 dBA @ 15 ft. | 1,750 | 1 | 1/3 | 24" | 24" | 12 5/8" | 37 | 104° F | Steel | Aluminum | __ | 0000000 | 000000 | 0000000 | 000000 |
3 | 18" | 4,200 | 53 dBA @ 15 ft. | 1,750 | 1 | 1/2 | 26" | 26" | 13 7/8" | 40 | 104° F | Steel | Aluminum | __ | 0000000 | 000000 | 000000 | 00 |
3 | 20" | 2,925 | Not Rated | 1,140 | 2 | 1/4 | 23 1/8" | 23 1/8" | 10" | 35 | 100° F | Steel | Aluminum | UL Recognized Component | 0000000 | 000000 | 000000 | 00 |
3 | 24" | 4,800 | 56 dB @ 5 ft. | 850 | 1 | 1/2 | 30" | 30" | 15 1/2" | 45 | 104° F | Steel | Aluminum | __ | 0000000 | 000000 | 0000000 | 000000 |
4 | 30" | 7,300 | 61 dB @ 5 ft. | 825 | 1 | 1/2 | 36" | 36" | 13 3/4" | 75 | 104° F | Steel | Steel | __ | 0000000 | 00000000 | 0000000 | 000000 |
4 | 36" | 8,600 | 65 dB @ 5 ft. | 825 | 1 | 1/2 | 42" | 42" | 12 1/4" | 95 | 104° F | Steel | Steel | __ | 0000000 | 00000000 | 0000000 | 000000 |
120/230V AC, Single Phase—Hardwire | ||||||||||||||||||
3 | 20" | 6,200 | 56 dBA @ 15 ft. | 1,750 | 1 | 3/4 | 28" | 28" | 15 5/8" | 60 | 104° F | Steel | Aluminum | __ | 0000000 | 000000 | 000000 | 00 |
208-230/460V AC, Three Phase—Hardwire | ||||||||||||||||||
4 | 30" | 7,300 | 61 dB @ 5 ft. | 825 | 1 | 1/2 | 36" | 36" | 13 3/4" | 74 | 104° F | Steel | Steel | __ | 0000000 | 00000000 | 0000000 | 000000 |
4 | 36" | 8,600 | 64 dB @ 5 ft. | 825 | 1 | 1/2 | 42" | 42" | 12 1/4" | 95 | 104° F | Steel | Steel | __ | 0000000 | 00000000 | 0000000 | 000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||||||
3 | 24" | 4,600 | 56 dB @ 5 ft. | 825 | 1 | 1/4 | 30" | 30" | 15 1/2" | 51 | 104° F | Steel | Aluminum | __ | 0000000 | 00000000 | 0000000 | 000000 |
5 | 18" | 3,900 | 66 dB @ 5 ft. | 1,750 | 1 | 1/2 | 24" | 24" | 10" | 42 | 104° F | Steel | Steel | __ | 000000 | 000000 | 0000000 | 000000 |
5 | 24" | 6,800 | 72 dB @ 5 ft. | 1,750 | 1 | 1 | 30" | 30" | 12 1/4" | 78 | 104° F | Steel | Steel | __ | 000000 | 00000000 | 0000000 | 000000 |
5 | 30" | 14,400 | 80 dB @ 5 ft. | 1,750 | 1 | 3 | 36" | 36" | 14 1/4" | 148 | 104° F | Steel | Steel | __ | 0000000 | 00000000 | 0000000 | 000000 |
5 | 36" | 20,300 | 83 dB @ 5 ft. | 1,750 | 1 | 5 | 42" | 42" | 15 3/4" | 225 | 104° F | Steel | Steel | __ | 0000000 | 00000000 | 0000000 | 000000 |
5 | 42" | 26,600 | 80 dB @ 5 ft. | 1,150 | 1 | 5 | 48" | 48" | 20" | 295 | 104° F | Steel | Steel | __ | 0000000 | 00000000 | 0000000 | 000000 |
5 | 48" | 37,100 | 82 dB @ 5 ft. | 1,150 | 1 | 7 1/2 | 54" | 54" | 22 1/2" | 470 | 104° F | Steel | Steel | __ | 0000000 | 00000000 | 0000000 | 000000 |