Material Material |
---|
|
Thread Type Thread Type |
---|
Connection Style Connection Style |
---|
![]() |
Flanged |
![]() |
Socket Connect |
![]() |
Threaded |
Threading Threading |
---|
![]() |
Threaded on Both Ends |
![]() |
Unthreaded |
System of Measurement System of Measurement |
---|
|
Length Length |
---|
Maximum Temperature Maximum Temperature |
---|
|
For Use With For Use With | Show |
---|
|
For Use With For Use With | Hide |
---|
For Pipe Material For Pipe Material |
---|
|
Connection Type Connection Type |
---|
![]() | Pipe |
Maximum Pressure Maximum Pressure |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Schedule Schedule |
---|
![]() | |
For Pipe Schedule For Pipe Schedule |
---|
![]() | |
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
How to Identify and Measure Fittings
Pipe size is an industry designation, not the actual size. View information about how to measure threaded and unthreaded pipe and pipe fittings.
More
Flame-Retardant PVDF Pipe Fittings for Chemicals
- For Use With: Chlorine, Salt Water, Solvents
- Temperature Range: 40° to 280° F
- Specifications Met: ASTM D3222, UL 94 V-0
- Pipe Nipples and Pipe: Use Schedule 80 PVDF Plastic
- Flanges: Use Class 150 PVDF Plastic
These fittings meet UL 94 V-0 for flame retardance, so they delay the spread of flames to valuable equipment. They are made of PVDF (polyvinylidene fluoride), which is comparable to Kynar, and has the chemical resistance to stand up to solvents and other harsh substances. Also known as Schedule 80 fittings, they have thick walls for heavy duty chemical processing applications. When connecting to pipe, apply a non-hardening, plastic-compatible sealant to the male threads to prevent leaks. Tape or sealants with PTFE are not recommended for plastic-to-plastic threaded connections. When making a threaded connection be careful not to overtighten the threads. To prevent cracks and leaks, finger tighten the fitting, then wrench-tighten one to two turns. Fittings meet ASTM D3222 specifications and testing requirements for material quality.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
Sealants cannot be sold to Colorado, Connecticut, District of Columbia, Delaware, Illinois, Indiana, Massachusetts, Maryland, Maine, Michigan, New Hampshire, New Jersey, Northern Virginia, New York, Ohio, Pennsylvania, Rhode Island, or Utah due to local VOC (Volatile Organic Compounds) regulations.
For technical drawings and 3-D models, click on a part number.

Pipe Size | Material | Color | Max. Pressure | Each | |
NPT Threads | |||||
---|---|---|---|---|---|
1/2 | PVDF Plastic | Red | 290 psi @ 72° F | 00000000 | 000000 |
3/4 | PVDF Plastic | Red | 230 psi @ 72° F | 00000000 | 00000 |
1 | PVDF Plastic | Red | 210 psi @ 72° F | 00000000 | 00000 |
1 1/2 | PVDF Plastic | Red | 160 psi @ 72° F | 00000000 | 000000 |
2 | PVDF Plastic | Red | 140 psi @ 72° F | 00000000 | 000000 |
Non-Hardening Thread Sealant (8-oz. Brush-Top Can) | 000000 | Each | 000000 |

Unions separate into three pieces, so you can access your line without unthreading pipe connections.
Pipe Size | Material | Color | O-Ring Material | Max. Pressure | Each | |
NPT Threads | ||||||
---|---|---|---|---|---|---|
1/2 | PVDF Plastic | Red | Viton® Fluoroelastomer Rubber | 290 psi @ 72° F | 00000000 | 0000000 |
3/4 | PVDF Plastic | Red | Viton® Fluoroelastomer Rubber | 230 psi @ 72° F | 00000000 | 000000 |
1 | PVDF Plastic | Red | Viton® Fluoroelastomer Rubber | 210 psi @ 72° F | 00000000 | 000000 |
1 1/2 | PVDF Plastic | Red | Viton® Fluoroelastomer Rubber | 160 psi @ 72° F | 00000000 | 000000 |
2 | PVDF Plastic | Red | Viton® Fluoroelastomer Rubber | 140 psi @ 72° F | 00000000 | 000000 |
Non-Hardening Thread Sealant (8-oz. Brush-Top Can) | 000000 | Each | 000000 |

Pipe Size (A) | Pipe Size (B) | Material | Color | Max. Pressure | Each | |
NPT Threads | ||||||
---|---|---|---|---|---|---|
3/4 | 1/2 | PVDF Plastic | Red | 230 psi @ 72° F | 00000000 | 000000 |
1 | 1/2 | PVDF Plastic | Red | 210 psi @ 72° F | 00000000 | 00000 |
1 | 3/4 | PVDF Plastic | Red | 210 psi @ 72° F | 00000000 | 00000 |
1 1/2 | 1 | PVDF Plastic | Red | 160 psi @ 72° F | 00000000 | 00000 |
2 | 1 1/2 | PVDF Plastic | Red | 140 psi @ 72° F | 00000000 | 000000 |
Non-Hardening Thread Sealant (8-oz. Brush-Top Can) | 000000 | Each | 000000 |

Pipe Size | Material | Color | Max. Pressure | Each | |
NPT Threads | |||||
---|---|---|---|---|---|
1/2 | PVDF Plastic | Red | 290 psi @ 72° F | 00000000 | 000000 |
3/4 | PVDF Plastic | Red | 230 psi @ 72° F | 00000000 | 00000 |
1 | PVDF Plastic | Red | 210 psi @ 72° F | 00000000 | 000000 |
1 1/2 | PVDF Plastic | Red | 160 psi @ 72° F | 00000000 | 000000 |
2 | PVDF Plastic | Red | 140 psi @ 72° F | 00000000 | 000000 |
Non-Hardening Thread Sealant (8-oz. Brush-Top Can) | 000000 | Each | 000000 |

Pipe Size | Material | Color | Max. Pressure | Each | |
NPT Threads | |||||
---|---|---|---|---|---|
1/2 | PVDF Plastic | Red | 290 psi @ 72° F | 00000000 | 000000 |
3/4 | PVDF Plastic | Red | 230 psi @ 72° F | 00000000 | 00000 |
1 | PVDF Plastic | Red | 210 psi @ 72° F | 00000000 | 000000 |
1 1/2 | PVDF Plastic | Red | 160 psi @ 72° F | 00000000 | 000000 |
2 | PVDF Plastic | Red | 140 psi @ 72° F | 00000000 | 000000 |
Non-Hardening Thread Sealant (8-oz. Brush-Top Can) | 000000 | Each | 000000 |
Flame-Retardant PVDF Pipe Nipples and Pipe for Chemicals
- For Use With: Chlorine, Salt Water, Solvents
- Max. Temperature: 280° F
- Specifications Met: ASTM D3222, UL 94 V-0
- Fittings: Use Schedule 80 PVDF Plastic
- Flanges: Use Class 150 PVDF Plastic
Pipe meets UL 94 V-0 for flame retardance, so it delays the spread of flames to valuable equipment. It is PVDF (polyvinylidene fluoride), which is comparable to Kynar, and has the chemical resistance to stand up to solvents and other harsh substances. Also known as Schedule 80 pipe, it has thick walls for heavy duty chemical processing applications. Pipe meets ASTM D3222 specifications and testing requirements for material quality.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
Sealants cannot be sold to Colorado, Connecticut, District of Columbia, Delaware, Illinois, Indiana, Massachusetts, Maryland, Maine, Michigan, New Hampshire, New Jersey, Northern Virginia, New York, Ohio, Pennsylvania, Rhode Island, or Utah due to local VOC (Volatile Organic Compounds) regulations.
For technical drawings and 3-D models, click on a part number.

To prevent leaks in threaded connections, apply a non-hardening, plastic-compatible sealant to the male threads. Tape or sealants with PTFE are not recommended for plastic-to-plastic threaded connections. When making a threaded connection be careful not to overtighten the threads. To prevent cracks and leaks, finger tighten the fitting, then wrench-tighten one to two turns.
2" | 4" | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | OD | ID | Wall Thick. | Material | Color | Max. Pressure | Each | Each | ||
NPT Threads | ||||||||||
1/2 | 27/32" | 0.546" | 0.147" | PVDF Plastic | Red | 290 psi @ 72° F | 00000000 | 000000 | 00000000 | 000000 |
3/4 | 1 3/64" | 0.742" | 0.154" | PVDF Plastic | Red | 230 psi @ 72° F | 00000000 | 00000 | 00000000 | 00000 |
1 | 1 5/16" | 0.957" | 0.179" | PVDF Plastic | Red | 210 psi @ 72° F | 00000000 | 00000 | 00000000 | 00000 |
1 1/2 | 1 29/32" | 1.5" | 0.2" | PVDF Plastic | Red | 160 psi @ 72° F | 00000000 | 00000 | 00000000 | 000000 |
2 | 2 3/8" | 1.939" | 0.218" | PVDF Plastic | Red | 140 psi @ 72° F | 00000000 | 00000 | 00000000 | 000000 |
Non-Hardening Thread Sealant (8-oz. Brush-Top Can) | 000000 | Each | 000000 |

Connect unthreaded pipe to unthreaded female socket-connect fittings using a primer and cement (also known as solvent weld).
2 ft. | 5 ft. | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | OD | ID | Wall Thick. | Material | Color | Max. Pressure | Each | Each | ||
1/2 | 27/32" | 0.546" | 0.147" | PVDF Plastic | Red | 290 psi @ 72° F | 00000000 | 0000000 | 00000000 | 0000000 |
3/4 | 1 3/64" | 0.742" | 0.154" | PVDF Plastic | Red | 230 psi @ 72° F | 00000000 | 000000 | 00000000 | 000000 |
1 | 1 5/16" | 0.957" | 0.179" | PVDF Plastic | Red | 210 psi @ 72° F | 00000000 | 000000 | 00000000 | 000000 |
1 1/2 | 1 29/32" | 1.5" | 0.2" | PVDF Plastic | Red | 160 psi @ 72° F | 00000000 | 000000 | 00000000 | 000000 |
2 | 2 3/8" | 1.939" | 0.218" | PVDF Plastic | Red | 130 psi @ 72° F | 00000000 | 000000 | 00000000 | 000000 |
Flame-Retardant PVDF Pipe Flanges for Chemicals



- For Use With: Chlorine, Salt Water, Solvents
- Temperature Range: 40° to 280° F
- Specifications Met: ASTM D3222, UL 94 V-0
- Pipe Nipples and Pipe: Use Schedule 80 PVDF Plastic
- Fittings: Use Schedule 80 PVDF Plastic
Flanges meet UL 94 V-0 for flame retardance to delay the spread of flames to valuable equipment. They are made of PVDF (polyvinylidene fluoride), which is comparable to Kynar, and has the chemical resistance to stand up to solvents and other harsh substances. Also known as Pressure Class 150 flanges, they have thick, strong walls for heavy duty chemical processing applications. Bolt two same-size flanges together with a gasket (sold separately) to create an access point within a line. When connecting to pipe, apply a non-hardening, plastic-compatible sealant to the male threads to prevent leaks. Tape or sealants with PTFE are not recommended for plastic-to-plastic threaded connections. When making a threaded connection be careful not to overtighten the threads. To prevent cracks and leaks, finger tighten the flange, then wrench-tighten one to two turns. Flanges meet ASTM D3222 specifications and testing requirements for material quality.
Warning: Never use plastic pipe flanges and pipe with compressed air or gas.
Sealants cannot be sold to Colorado, Connecticut, District of Columbia, Delaware, Illinois, Indiana, Massachusetts, Maryland, Maine, Michigan, New Hampshire, New Jersey, Northern Virginia, New York, Ohio, Pennsylvania, Rhode Island, or Utah due to local VOC (Volatile Organic Compounds) regulations.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Flanged Connection Surface | Flange OD | For Bolt Dia. | Bolt Hole Dia. | Number of Bolt Holes | Bolt Circle Dia. | Material | Color | Max. Pressure | Each | |
Fixed Flange, Female Threaded × Flanged | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
NPT Threads | |||||||||||
1/2 | Flat | 3 1/2" | 1/2" | 5/8" | 4 | 2 5/16" | PVDF Plastic | Red | 150 psi @ 72° F | 00000000 | 0000000 |
3/4 | Flat | 3 7/8" | 1/2" | 5/8" | 4 | 2 11/16" | PVDF Plastic | Red | 150 psi @ 72° F | 00000000 | 000000 |
1 | Flat | 4 1/4" | 1/2" | 9/16" | 4 | 4" | PVDF Plastic | Red | 150 psi @ 72° F | 00000000 | 000000 |
1 1/2 | Flat | 5" | 1/2" | 5/8" | 4 | 3 3/4" | PVDF Plastic | Red | 150 psi @ 72° F | 00000000 | 000000 |
2 | Raised | 6" | 5/8" | 3/4" | 4 | 4 3/4" | PVDF Plastic | Red | 150 psi @ 72° F | 00000000 | 000000 |
Non-Hardening Thread Sealant (8-oz. Brush-Top Can) | 000000 | Each | 000000 |
Fiberglass Pipe Flanges for Corrosive Chemicals
- For Use With: Acetic Acid (75%), Alcohol, Calcium Chloride, Chlorine, Fuel Oil, Gasoline, Hydrochloric Acid (37%), Nitric Acid (10%), Oil, Phosphoric Acid, Salt Water (30%), Sodium Hydroxide (50%), Solvents, Sulfuric Acid (70%), Water
- Temperature Range: 32° to 200° F
- Specifications Met: ASTM D4024
Flanges have excellent corrosion resistance to handle a wide range of acids and other highly-corrosive chemicals. Use in metal surface treating applications, plating solution lines, and other chemical process applications. They are reinforced with fiberglass layers for better strength and durability than any of our other pipe flanges for chemicals. Bolt two same-size flanges together with a gasket (sold separately) to create an access point within a line. Flanges meet ASTM D4024 specifications and testing requirements for product dimensions, performance, and material quality.
To connect flanges to pipe, first sand the inside of the flange and the end of the pipe to remove the surface finish. Next, mix the adhesive (sold separately) until the color is uniform with no streaks. Apply a thin layer of mixed adhesive to the sanded area of the pipe, approximately 1/8” thick. Repeat this process with the inside of the flange, applying a layer approximately 1/16” thick. After sealant has been applied, push the flange onto the pipe until it is fully engaged. Make sure you align the bolt holes prior to installing to minimize rotation after the flange is installed. Finally, use the adhesive-curing heat cable (sold separately) to cure the adhesive. Wrap the tape around the pipe and flange at the joint, taking care to not overlap the tape. Once you have waited the full cure time, the pipe and flange will be ready to use.
Warning: Never use plastic pipe flanges and pipe with compressed air or gas.
For technical drawings and 3-D models, click on a part number.


Pipe Size | Socket Dp. | Flange OD | For Bolt Dia. | Bolt Hole Dia. | Number of Bolt Holes | Bolt Circle Dia. | Material | Color | Max. Pressure | Each | |
1 1/2 | 1 3/8" | 5" | 1/2" | 5/8" | 4 | 3 7/8" | Fiberglass | Black | 300 psi @ 72° F | 0000000 | 0000000 |
2 | 1 3/4" | 6" | 5/8" | 3/4" | 4 | 4 3/4" | Fiberglass | Black | 250 psi @ 72° F | 0000000 | 000000 |
3 | 2" | 7 1/2" | 5/8" | 3/4" | 4 | 6" | Fiberglass | Black | 250 psi @ 72° F | 0000000 | 000000 |
4 | 2 1/2" | 9" | 5/8" | 3/4" | 8 | 7 1/2" | Fiberglass | Black | 150 psi @ 72° F | 0000000 | 000000 |
Pipe Cement (11.8-fl. oz. Can) | 0000000 | Each | 000000 |


Cap flanges are also known as blind flanges.
Pipe Size | Flange OD | For Bolt Dia. | Bolt Hole Dia. | Number of Bolt Holes | Bolt Circle Dia. | Material | Color | Max. Pressure | Each | |
1 1/2 | 5" | 1/2" | 5/8" | 4 | 3 7/8" | Fiberglass | Black | 300 psi @ 72° F | 0000000 | 0000000 |
2 | 6" | 5/8" | 3/4" | 4 | 4 3/4" | Fiberglass | Black | 250 psi @ 72° F | 0000000 | 000000 |
3 | 7 1/2" | 5/8" | 3/4" | 4 | 6" | Fiberglass | Black | 250 psi @ 72° F | 0000000 | 000000 |
4 | 9" | 5/8" | 3/4" | 8 | 7 1/2" | Fiberglass | Black | 150 psi @ 72° F | 0000000 | 000000 |
Pipe Cement (11.8-fl. oz. Can) | 0000000 | Each | 000000 |

Voltage | Max. Heat Output, °F | Lg. | Wd. | Thick. | Plug Type | Cord Lg. | Each | |
120V AC | 270° | 6 ft. | 1" | 1/8" | Two Prong | 6 ft. | 0000000 | 0000000 |
Fiberglass Pipe Fittings for Corrosive Chemicals
- For Use With: Acetic Acid (75%), Alcohol, Calcium Chloride, Chlorine, Fuel Oil, Gasoline, Hydrochloric Acid (37%), Nitric Acid (10%), Oil, Phosphoric Acid, Salt Water (30%), Sodium Hydroxide (50%), Solvents, Sulfuric Acid (70%), Water
- Temperature Range: 32° to 200° F
- Specifications Met: ASTM D3567
These fittings have excellent corrosion resistance to handle a wide range of acids and other highly-corrosive chemicals. They are commonly used in metal surface treating applications, plating solution lines, and other chemical process applications. Reinforced with layers of fiberglass, they have better strength and durability than any of our other pipe fittings for chemicals. Fittings meet ASTM D3567 specifications for product dimensions.
To connect fittings to pipe, first sand the inside of the fitting and the end of the pipe to remove the surface finish. Next, mix the adhesive (sold separately) until the color is uniform with no streaks. Apply a thin layer of mixed adhesive to the sanded area of the pipe, approximately 1/8” thick. Repeat this process with the inside of the fitting, applying a layer approximately 1/16” thick. After sealant has been applied, push the fitting onto the pipe until it is fully engaged. Finally, use the adhesive-curing heat cable (sold separately) to cure the adhesive. Wrap the tape around the pipe and fitting at the joint, taking care to not overlap the tape. Once you have waited the full cure time, the pipe and fitting will be ready to use.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
For technical drawings and 3-D models, click on a part number.

(A) | (B) | |||||||
---|---|---|---|---|---|---|---|---|
Pipe Size | Socket Dp. | Pipe Size | Socket Dp. | Material | Color | Max. Pressure | Each | |
2 | 1 1/2" | 1 1/2 | 1 5/16" | Fiberglass | Black | 250 psi @ 72° F | 0000000 | 0000000 |
3 | 2" | 1 1/2 | 1 1/2" | Fiberglass | Black | 250 psi @ 72° F | 0000000 | 000000 |
3 | 2" | 2 | 1 1/2" | Fiberglass | Black | 250 psi @ 72° F | 0000000 | 000000 |
4 | 2 5/8" | 2 | 1 1/2" | Fiberglass | Black | 150 psi @ 72° F | 0000000 | 000000 |
4 | 2 5/8" | 3 | 2" | Fiberglass | Black | 150 psi @ 72° F | 0000000 | 000000 |
Pipe Cement (11.8-fl. oz. Can) | 0000000 | Each | 000000 |

Voltage | Max. Heat Output, °F | Lg. | Wd. | Thick. | Plug Type | Cord Lg. | Each | |
120V AC | 270° | 6 ft. | 1" | 1/8" | Two Prong | 6 ft. | 0000000 | 0000000 |
Fiberglass Pipe for Corrosive Chemicals
- For Use With: Acetic Acid (75%), Alcohol, Calcium Chloride, Chlorine, Fuel Oil, Gasoline, Hydrochloric Acid (37%), Nitric Acid (10%), Oil, Phosphoric Acid, Salt Water (30%), Sodium Hydroxide (50%), Sulfuric Acid (70%), Water
- Temperature Range: 32° to 200° F
- Specifications Met: ASTM D2310, ASTM D3567
With excellent corrosion resistance, this pipe can handle a wide range of acids and other highly-corrosive chemicals. Use in metal surface treating applications, plating solution lines, and other chemical process applications. Layers of fiberglass give this pipe better strength and durability than any of our other pipe for chemicals. Pipe meets ASTM D2310 and ASTM D3567 specifications and testing requirements for product dimensions, performance, and material quality.
To connect fittings to pipe, first sand the inside of the fitting and the end of the pipe to remove the surface finish. Next, mix the adhesive (sold separately) until the color is uniform with no streaks. Apply a thin layer of mixed adhesive to the sanded area of the pipe, approximately 1/8” thick. Repeat this process with the inside of the fitting, applying a layer approximately 1/16” thick. After sealant has been applied, push the fitting onto the pipe until it is fully engaged. Finally, use the adhesive-curing heat cable (sold separately) to cure the adhesive. Wrap the tape around the pipe and fitting at the joint, taking care to not overlap the tape. Once you have waited the full cure time, the pipe and fitting will be ready to use.
Warning: Never use plastic pipe fittings and pipe with compressed air or gas.
For technical drawings and 3-D models, click on a part number.

5 ft. | 10 ft. | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | OD | ID | Wall Thick. | Material | Color | Max. Pressure | Each | Each | ||
1 1/2 | 1 7/8" | 1.6" | 0.14" | Fiberglass | Green | 300 psi @ 72° F | 0000000 | 0000000 | 0000000 | 0000000 |
2 | 2 3/8" | 2.06" | 0.16" | Fiberglass | Green | 250 psi @ 72° F | 0000000 | 000000 | 0000000 | 000000 |
3 | 3 1/2" | 3.07" | 0.22" | Fiberglass | Green | 250 psi @ 72° F | 0000000 | 000000 | 0000000 | 000000 |
4 | 4 1/2" | 4.03" | 0.24" | Fiberglass | Green | 150 psi @ 72° F | 0000000 | 000000 | 0000000 | 000000 |
Pipe Cement (11.8-fl. oz. Can) | 0000000 | Each | 000000 |

Voltage | Current | Max. Heat Output, °F | Lg. | Wd. | Thick. | Plug Type | Cord Lg. | Each | |
120V AC | 15 A | 270° | 6 ft. | 1" | 1/8" | Two Prong | 6 ft. | 0000000 | 0000000 |