About Wire and Cable
More
Vehicle Wire Assortments
- Use for vehicles
- Flexible
- Temperature Range:
GPT Wire: -40° to 185° F
TXL and GXL Wire: -40° to 255° F
Keep spools of vehicle wire in multiple colors on hand. They meet SAE J1128 for low-voltage wiring in trucks, boats, trailers, and other vehicles.
GPT wire, or primary wire, has PVC insulation that makes it useful as a general purpose wire.
TXL and GXL wire have cross-linked polyethylene insulation that withstands higher temperatures and has more abrasion resistance than PVC insulation. TXL wire has thin walls, so it’s small and lightweight. It’s often used for dashboards and other car interior applications. GXL wire has thick walls, making it suitable for engine compartments.
No. of Spools | Wire Ga. | Strand Count | Current | OD | Outer Insulation Color | Length, ft. | Specifications Met | Each | |
GPT Stranded Wire with PVC Plastic Insulation | |||||||||
---|---|---|---|---|---|---|---|---|---|
25V AC/60V DC | |||||||||
5 | 22 | 7/30 | 3 A @ 86° F | 0.08" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 000000 |
5 | 20 | 7/28 | 5 A @ 86° F | 0.08" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 18 | 16/30 | 17 A @ 86° F | 0.09" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 16 | 19/29 | 22 A @ 86° F | 0.11" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 14 | 19/27 | 30 A @ 86° F | 0.12" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 12 | 19/25 | 40 A @ 86° F | 0.14" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 000000 |
5 | 10 | 19/23 | 55 A @ 86° F | 0.18" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 000000 |
TXL Stranded Wire with Cross-Linked Polyethylene (XLPE) Insulation | |||||||||
25V AC/60V DC | |||||||||
5 | 22 | 7/30 | 3 A @ 86° F | 0.06" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 20 | 7/28 | 5 A @ 86° F | 0.07" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 18 | 16/30 | 7 A @ 86° F | 0.08" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 16 | 19/29 | 10 A @ 86° F | 0.09" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 14 | 19/27 | 15 A @ 86° F | 0.1" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 12 | 19/25 | 20 A @ 86° F | 0.13" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 000000 |
GXL Stranded Wire with Cross-Linked Polyethylene (XLPE) Insulation | |||||||||
25V AC/60V DC | |||||||||
5 | 20 | 7/28 | 5 A @ 86° F | 0.09" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 18 | 16/30 | 5 A @ 86° F | 0.09" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 16 | 19/29 | 8 A @ 86° F | 0.1" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 14 | 19/27 | 11 A @ 86° F | 0.12" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 00000 |
5 | 12 | 19/25 | 14 A @ 86° F | 0.15" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 000000 |
5 | 10 | 19/23 | 23 A @ 86° F | 0.18" | Black, Blue, Green, Red, White | 25 | SAE J1128 | 0000000 | 000000 |
Vehicle Wire
Originally designed to meet the quality standards of the auto industry, this wire withstands high temperatures, flames, and abrasion. Unlike other low-voltage wires, this wire meets strict SAE performance requirements. You'll often hear it referred to as primary wire in trucks, trailers, forklifts, and other vehicles.
In protected environments, such as vehicle interiors, GPT wire is the best choice.
For wiring exposed to weather and wear and tear, choose a wire with polyethylene insulation. For these applications, GXL wire is the standard choice, as it balances flexibility and abrasion-resistance. TXL wire has a thinner insulation, making it easy to maneuver in tight spaces. SXL wire has a thicker insulation and is the most durable. It can withstand repeated exposure to heat, dust, chemicals, and salt.
For technical drawings and 3-D models, click on a part number.
- Use for vehicles
- Flexible
- Temperature Range: -10° to 175° F
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Each | |
25V AC/60V DC | |||||||||
---|---|---|---|---|---|---|---|---|---|
20 | 10/30 | 9 A @ 86° F | 0.09" | GPT | SAE J1128 | 100 | 0000000 | 000000 | |
18 | 16/30 | 17 A @ 86° F | 0.1" | GPT | SAE J1128 | 45 | 0000000 | 0000 | |
18 | 16/30 | 17 A @ 86° F | 0.1" | GPT | SAE J1128 | 100 | 0000000 | 00000 | |
16 | 19/29 | 21 A @ 86° F | 0.11" | GPT | SAE J1128 | 35 | 0000000 | 0000 | |
16 | 19/29 | 21 A @ 86° F | 0.11" | GPT | SAE J1128 | 100 | 0000000 | 00000 | |
14 | 19/27 | 29 A @ 86° F | 0.12" | GPT | SAE J1128 | 20 | 0000000 | 0000 | |
14 | 19/27 | 29 A @ 86° F | 0.12" | GPT | SAE J1128 | 100 | 0000000 | 00000 | |
12 | 19/25 | 38 A @ 86° F | 0.15" | GPT | SAE J1128 | 12 | 0000000 | 0000 | |
12 | 19/25 | 38 A @ 86° F | 0.15" | GPT | SAE J1128 | 100 | 0000000 | 00000 | |
10 | 19/23 | 51 A @ 86° F | 0.18" | GPT | SAE J1128 | 8 | 0000000 | 0000 | |
10 | 19/23 | 51 A @ 86° F | 0.18" | GPT | SAE J1128 | 100 | 0000000 | 00000 | |
8 | 19/21 | 51 A @ 86° F | 0.22" | GPT | SAE J1128 | 8 | 000000 | 0000 | |
8 | 19/21 | 51 A @ 86° F | 0.22" | GPT | SAE J1128 | 100 | 000000 | 00000 |
- Use for vehicles
- Flexible
- Temperature Range: -40° to 255° F
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Each | |
25V AC/60V DC | |||||||||
---|---|---|---|---|---|---|---|---|---|
20 | 7/28 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 25 | 000000 | 00000 | |
20 | 7/28 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 50 | 000000 | 00000 | |
20 | 7/28 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 100 | 000000 | 00000 | |
20 | 7/28 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 250 | 000000 | 00000 | |
20 | 7/28 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 500 | 000000 | 00000 | |
18 | 16/30 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 25 | 000000 | 0000 | |
18 | 16/30 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 50 | 000000 | 00000 | |
18 | 16/30 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 100 | 000000 | 00000 | |
18 | 16/30 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 250 | 000000 | 00000 | |
18 | 16/30 | 5 A @ 86° F | 0.09" | GXL | SAE J1128 | 500 | 00000000 | 00000 | |
16 | 19/29 | 8 A @ 86° F | 0.11" | GXL | SAE J1128 | 25 | 00000000 | 0000 | |
16 | 19/29 | 8 A @ 86° F | 0.11" | GXL | SAE J1128 | 50 | 00000000 | 00000 | |
16 | 19/29 | 8 A @ 86° F | 0.11" | GXL | SAE J1128 | 100 | 00000000 | 00000 | |
16 | 19/29 | 8 A @ 86° F | 0.11" | GXL | SAE J1128 | 250 | 00000000 | 00000 | |
16 | 19/29 | 8 A @ 86° F | 0.11" | GXL | SAE J1128 | 500 | 00000000 | 000000 | |
14 | 19/27 | 11 A @ 86° F | 0.12" | GXL | SAE J1128 | 25 | 00000000 | 00000 | |
14 | 19/27 | 11 A @ 86° F | 0.12" | GXL | SAE J1128 | 50 | 00000000 | 00000 | |
14 | 19/27 | 11 A @ 86° F | 0.12" | GXL | SAE J1128 | 100 | 00000000 | 00000 | |
14 | 19/27 | 11 A @ 86° F | 0.12" | GXL | SAE J1128 | 250 | 00000000 | 00000 | |
14 | 19/27 | 11 A @ 86° F | 0.12" | GXL | SAE J1128 | 500 | 00000000 | 000000 | |
12 | 19/25 | 14 A @ 86° F | 0.15" | GXL | SAE J1128 | 25 | 00000000 | 00000 | |
12 | 19/25 | 14 A @ 86° F | 0.15" | GXL | SAE J1128 | 50 | 00000000 | 00000 | |
12 | 19/25 | 14 A @ 86° F | 0.15" | GXL | SAE J1128 | 100 | 00000000 | 00000 | |
12 | 19/25 | 14 A @ 86° F | 0.15" | GXL | SAE J1128 | 250 | 00000000 | 000000 | |
12 | 19/25 | 14 A @ 86° F | 0.15" | GXL | SAE J1128 | 500 | 00000000 | 000000 | |
10 | 19/23 | 23 A @ 86° F | 0.18" | GXL | SAE J1128 | 25 | 00000000 | 00000 | |
10 | 19/23 | 23 A @ 86° F | 0.18" | GXL | SAE J1128 | 50 | 00000000 | 00000 | |
10 | 19/23 | 23 A @ 86° F | 0.18" | GXL | SAE J1128 | 100 | 00000000 | 00000 | |
10 | 19/23 | 23 A @ 86° F | 0.18" | GXL | SAE J1128 | 250 | 00000000 | 000000 | |
10 | 19/23 | 23 A @ 86° F | 0.18" | GXL | SAE J1128 | 500 | 00000000 | 000000 |
- Use for vehicles
- Flexible
- Temperature Range: -40° to 255° F
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Each | |
25V AC/60V DC | |||||||||
---|---|---|---|---|---|---|---|---|---|
22 | 7/30 | 3 A @ 86° F | 0.06" | TXL | SAE J1128 | 25 | 000000 | 00000 | |
22 | 7/30 | 3 A @ 86° F | 0.06" | TXL | SAE J1128 | 50 | 000000 | 0000 | |
22 | 7/30 | 3 A @ 86° F | 0.06" | TXL | SAE J1128 | 100 | 000000 | 00000 | |
22 | 7/30 | 3 A @ 86° F | 0.06" | TXL | SAE J1128 | 250 | 000000 | 00000 | |
22 | 7/30 | 3 A @ 86° F | 0.06" | TXL | SAE J1128 | 500 | 000000 | 00000 | |
20 | 7/28 | 5 A @ 86° F | 0.07" | TXL | SAE J1128 | 25 | 000000 | 0000 | |
20 | 7/28 | 5 A @ 86° F | 0.07" | TXL | SAE J1128 | 50 | 000000 | 0000 | |
20 | 7/28 | 5 A @ 86° F | 0.07" | TXL | SAE J1128 | 100 | 000000 | 00000 | |
20 | 7/28 | 5 A @ 86° F | 0.07" | TXL | SAE J1128 | 250 | 000000 | 00000 | |
20 | 7/28 | 5 A @ 86° F | 0.07" | TXL | SAE J1128 | 500 | 00000000 | 00000 | |
18 | 16/30 | 7 A @ 86° F | 0.08" | TXL | SAE J1128 | 25 | 00000000 | 0000 | |
18 | 16/30 | 7 A @ 86° F | 0.08" | TXL | SAE J1128 | 50 | 00000000 | 0000 | |
18 | 16/30 | 7 A @ 86° F | 0.08" | TXL | SAE J1128 | 100 | 00000000 | 00000 | |
18 | 16/30 | 7 A @ 86° F | 0.08" | TXL | SAE J1128 | 250 | 00000000 | 00000 | |
18 | 16/30 | 7 A @ 86° F | 0.08" | TXL | SAE J1128 | 500 | 00000000 | 00000 | |
16 | 19/29 | 10 A @ 86° F | 0.09" | TXL | SAE J1128 | 25 | 00000000 | 0000 | |
16 | 19/29 | 10 A @ 86° F | 0.09" | TXL | SAE J1128 | 50 | 00000000 | 00000 | |
16 | 19/29 | 10 A @ 86° F | 0.09" | TXL | SAE J1128 | 100 | 00000000 | 00000 | |
16 | 19/29 | 10 A @ 86° F | 0.09" | TXL | SAE J1128 | 250 | 00000000 | 00000 | |
16 | 19/29 | 10 A @ 86° F | 0.09" | TXL | SAE J1128 | 500 | 00000000 | 00000 | |
14 | 19/27 | 15 A @ 86° F | 0.1" | TXL | SAE J1128 | 25 | 00000000 | 00000 | |
14 | 19/27 | 15 A @ 86° F | 0.1" | TXL | SAE J1128 | 50 | 00000000 | 00000 | |
14 | 19/27 | 15 A @ 86° F | 0.1" | TXL | SAE J1128 | 100 | 00000000 | 00000 | |
14 | 19/27 | 15 A @ 86° F | 0.1" | TXL | SAE J1128 | 250 | 00000000 | 00000 | |
14 | 19/27 | 15 A @ 86° F | 0.1" | TXL | SAE J1128 | 500 | 00000000 | 000000 | |
12 | 19/25 | 20 A @ 86° F | 0.13" | TXL | SAE J1128 | 25 | 00000000 | 00000 | |
12 | 19/25 | 20 A @ 86° F | 0.13" | TXL | SAE J1128 | 50 | 00000000 | 00000 | |
12 | 19/25 | 20 A @ 86° F | 0.13" | TXL | SAE J1128 | 100 | 00000000 | 00000 | |
12 | 19/25 | 20 A @ 86° F | 0.13" | TXL | SAE J1128 | 250 | 00000000 | 000000 | |
12 | 19/25 | 20 A @ 86° F | 0.13" | TXL | SAE J1128 | 500 | 00000000 | 000000 |
- Use for vehicles
- Flexible
- Temperature Range: -40° to 255° F
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | Length, ft. | Each | |
25V AC/60V DC | |||||||||
---|---|---|---|---|---|---|---|---|---|
18 | 16/30 | 20 A @ 86° F | 0.11" | SXL | SAE J1128 | 25 | 0000000 | 00000 | |
18 | 16/30 | 20 A @ 86° F | 0.11" | SXL | SAE J1128 | 100 | 0000000 | 00000 | |
16 | 19/29 | 26 A @ 86° F | 0.12" | SXL | SAE J1128 | 25 | 0000000 | 0000 | |
16 | 19/29 | 26 A @ 86° F | 0.12" | SXL | SAE J1128 | 100 | 0000000 | 00000 | |
14 | 19/27 | 40 A @ 86° F | 0.14" | SXL | SAE J1128 | 25 | 0000000 | 00000 | |
14 | 19/27 | 40 A @ 86° F | 0.14" | SXL | SAE J1128 | 100 | 0000000 | 00000 | |
12 | 19/25 | 50 A @ 86° F | 0.16" | SXL | SAE J1128 | 25 | 0000000 | 00000 | |
12 | 19/25 | 50 A @ 86° F | 0.16" | SXL | SAE J1128 | 100 | 0000000 | 00000 | |
10 | 19/23 | 70 A @ 86° F | 0.19" | SXL | SAE J1128 | 25 | 0000000 | 00000 | |
10 | 19/23 | 70 A @ 86° F | 0.19" | SXL | SAE J1128 | 100 | 0000000 | 00000 |