McMaster-Carr logo
    Filter by
    Resettable
    Number of Digits
    Display Type
    Maximum Counts per Minute
    Batteries Included
    Counting Direction
    Wire Connection
    Electrical Connection Type
    Mounting Location
    Overall Width
    Panel Cutout Height
    Electrical Connection
    Height
    Panel Cutout Width
    Material
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    11 Products

    Switch-Contact-Actuated Counters

    Image of Product. Front orientation. Counters. Switch-Contact-Actuated Counters , Clip On, Manual Reset Button.

    Clip On,

    Manual Reset

    Button

    No need for a separate power source—these counters are powered by internal batteries that last more than seven years. Often used in areas where power isn’t easy to access, they work well inside machinery or remote monitoring systems. Wire them to a relay, sensor, switch, or other trigger device on the machine performing repeated tasks. The counter receives a signal from the trigger device to track how many times the task has occurred and shows that number on the display.
    All can be connected to a separate input, button, or switch to reset the counter to zero directly or at a distance.
    Clip On—Clip on counters can be mounted with a gasket (sold separately) to meet NEMA 4/4X, NEMA 12, and IP66 ratings for protection against dust, water, and splashing oil and coolant.
    Indicator Icons—Counters with indicator icons can be programmed to flash a symbol of your choosing after a set number of tasks have been completed. Similar to the lights on your car’s dashboard, there are icons for your oil, oil filter, service, and more.
    Manual Reset Button—Those with a manual reset button can be set to zero with a simple push.
    Counters
    Gaskets
    For Panel
    Cutout
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts
    per min.
    DIN
    Size
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Batteries
    Replaceable
    Features
    Certification
    Housing
    Material
    Each
    Each
    Clip On
     
    Wire Leads
    YesUp830,0001/320.87"1.78"1.1"2"1.5"NoBattery-Powered Display, Indicator Icons, Manual Reset Button, Remote ResetUL Recognized Component, C-UL Recognized Component, CE Marked
    Plastic7235N110000008672T4600000
     

    Panel-Mount Electrically Actuated Hour Meters

    Image of Product. Front orientation. Hour Meters. Panel-Mount Electrically Actuated Hour Meters, Screw On, Style E.
    Image of Product. Front orientation. Hour Meters. Panel-Mount Electrically Actuated Hour Meters, Screw On, Style J.
    Image of Product. Front orientation. Hour Meters. Panel-Mount Electrically Actuated Hour Meters, Clip Mount, Style P.
    Image of Product. Front orientation. Hour Meters. Panel-Mount Electrically Actuated Hour Meters, Clip Mount, Style R.

    Screw On

    Style E

    Screw On

    Style J

    Clip Mount

    Style P

    Clip Mount

    Style R

    Display running time on a machine so you can schedule preventative maintenance.
    Not Resettable—Non-resettable meters prevent tampering and accidental loss of data.
    Indicator Icons—Meters with indicator icons can be programmed to show visual alerts for the kind of maintenance task you need to perform. They include seven different icons.
    Gaskets—Mount meters with a gasket to help them meet NEMA 4X, 12, and IP66 ratings for protection against dust and splashing with water, oil, and coolant.
    Hour Meters
    Gaskets
    Counter Gaskets
    For Panel
    Cutout
    Overall
    Style
    Resettable
    Counting
    Direction
    No. of
    Digits
    Wd.
    Ht.
    Ht.
    Wd.
    Dp.
    Dia.
    Operating Voltage
    Features
    Each
    Each
    Each
    Screw On
     
    Screw Terminals
    EYesUp81.8"0.9"1"1.9"2.1"10V AC to 240V AC, 5V DC to 110V DCBattery-Powered Display17015T11000000———0———0
     
    Spade Terminals
    JNoUp81.4"0.9"1.1"2.9"20V AC to 270V AC, 10V DC to 300V DCBattery-Powered Display8672T41000008672T4500000———0
     
    Clip Mount
     
    Screw Terminals
    PYesUp81.7"0.8"1.1"2"1.5"20V AC to 270V AC, 10V DC to 300V DCBattery-Powered Display, Indicator Icons8672T44000008672T460000———0
     
    Spade Terminals
    RNoUp81.4"0.9"1.1"1.6"0.8"20V AC to 270V AC, 10V DC to 300V DCBattery-Powered Display8672T4200000———01806T2700000
    RYesUp81.4"0.9"1.1"1.6"0.8"20V AC to 270V AC, 10V DC to 300V DCBattery-Powered Display8672T4300000———01806T270000
     

    Switch-Contact-Actuated Hour Meters

    Image of Product. Front orientation. Hour Meters. Switch-Contact-Actuated Hour Meters, Screw On.

    Screw On

    Image of Product. Front orientation. Hour Meters. Switch-Contact-Actuated Hour Meters, Clip On.

    Clip On

    No need for a separate power source—these hour meters are powered by internal batteries that last more than 10 years. Often used where power sources aren’t easily accessible, they work well in remote monitoring systems, industrial equipment, and machinery. Wire the hour meter to a relay or switch on your machine so it can receive signals when the machine is running. The total number of hours is shown on the display. Press a button on the meter to reset the time to zero or connect it to a switch or button to reset it from a distance.
    Clip On—Clip-on hour meters can be programmed to flash an icon of your choosing after your machine has run for a set number of hours. Similar to the lights on your car’s dashboard, the icons signal maintenance for your oil, oil filter, service, and more.
    IP65 Enclosure Rating, NEMA 4X Enclosure Rating, and NEMA 12 Enclosure Rating—Screw on hour meters are IP65, NEMA 4X, and NEMA 12 rated, so they’re protected from dust, water, and splashing oil and coolant.
    UL Recognized Component, C-UL Recognized Component, and CE Marked—These meters are UL recognized, C-UL recognized, and CE marked, so they meet American, Canadian, and European safety standards.
    Gaskets—Mount them with a gasket (sold separately) to protect against dust, water, and splashing oil and coolant and so they’ll meet NEMA 4/4X, NEMA 12, and IP66 ratings.
    Hour Meters
    Gaskets
    For Panel
    Cutout
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    Wd.
    Ht.
    Ht.
    Wd.
    Dp.
    Features
    Enclosure Rating
    Certification
    Each
    Each
    Screw On
     
    Screw-Terminal Wire Connection
    YesUp and Down81.8"0.9"1"1.9"2.1"Battery-Powered Display, Manual Reset Button, Remote ResetIP65, NEMA 4X, NEMA 12
    UL Recognized Component, C-UL Recognized Component, CE Marked
    17015T12000000———0
     
    Clip On
     
    Screw-Terminal Wire Connection
    YesUp81.7"0.8"1.1"2"1.5"Battery-Powered Display, Indicator Icons, Manual Reset Button, Remote ResetIP66
    UL Recognized Component, C-UL Recognized Component, CE Marked
    7243N11000008672T4600000
     
    back to top