Build-Your-Own Fixed Work Platforms

Configure a work platform to fit your application. Made of aluminum, these platforms are lightweight and corrosion resistant. Platform and steps are serrated for maximum slip resistance.
First, determine how high your work platform needs to be and choose the stairs that accommodate that height. Then, choose a platform section based on the desired length. Next, choose platform supports that correspond to the height of your stairs—each end of the platform must be supported by a platform support. Finally, choose handrails for the stairs and platform. Assembled work platforms should be secured to a supporting surface (mounting hardware not included).
Note: Work platforms meet OSHA dimensional standards. Users are responsible for checking local, state, and federal codes, including OSHA, for safe installation and operating practices. Work platforms also meet CAL-OSHA standards, which is required for use in California.
Step | Mounting Holes | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Platform Ht. | Ground Clearance Ht. | No. of Steps | Wd. | Dp. | Tread | Climbing Angle | Cap., lbs. | Assembled or Unassembled | Mounting Hardware Included | No. of | Dia. | Specifications Met | Each | |
Aluminum | ||||||||||||||
| 27" | 23" | 2 | 24" | 9 1/2" | Serrated | 45° | 500 | Unassembled | No | 4 | 7/16" | ANSI/ASSE A1264.1, Cal/OSHA Compliant Title 8 Section 3209, Cal/OSHA Compliant Title 8 Section 3622, OSHA Compliant 29 CFR 1910 Subpart D | 0000000 | 0000000 |
Nonconductive Build-Your-Own Fixed Work Platforms


These platforms are nonconductive fiberglass. Configure them to fit your application. For good slip resistance, platforms are perforated and stairs are grit coated.
First, determine how high your work platform needs to be and choose the stairs that accommodate that height. Then, choose a platform section based on the desired length. Next, choose platform supports that correspond to the height of your stairs—each end of the platform must be supported by a platform support. Finally, choose handrails for the stairs and platform. Assembled work platforms should be secured to a supporting surface.
Note: Work platforms meet OSHA dimensional standards. Users are responsible for checking local, state, and federal codes, including OSHA, for safe installation and operating practices. Work platforms also meet CAL-OSHA standards, which is required for use in California.
Step | Mounting Holes | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Platform Ht. | Ground Clearance Ht. | No. of Steps | Wd. | Dp. | Finish | Cap., lbs. | Color | Assembled or Unassembled | Mounting Hardware Included | No. of | Dia. | Specifications Met | Each | |
Fiberglass | ||||||||||||||
| 27" | 20" | 2 | 25 3/4" | 10 1/2" | Grit Coated | 250 | Gray | Unassembled | Yes | 2 | 9/16" | Cal/OSHA Compliant Title 8 Section 3642, OSHA Compliant 29 CFR 1910 Subpart D, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.29 | 0000000 | 0000000 |
Fixed Work Platforms





Install these platforms for easy access to elevated areas. They’re large enough to provide plenty of space for working. Platform and steps are serrated for maximum slip resistance and to allow dirt and debris to fall through. Without work boots, standing on them for extended periods may be uncomfortable. The number of steps listed includes the platform.
Styles 1-5 allow you to lower the platform up to 3" by sliding the U-bolts.
Style 1 don’t have handrails, so you can work freely in any direction.
Styles 2 and 3 are open on one side. They’re often used beside conveyors or assembly stations.
Styles 4 and 5 have handrails on multiple sides of the platform to reduce fall risk.
Style 6 have a hinged access panel that you can flip up and remove to inspect and maintain nearby machinery, such as conveyor systems.
Note: Work platforms meet OSHA and Cal/OSHA dimensional and construction standards. Check local, state, and federal codes, including OSHA, for safe set up and operating practices.
Also Available: Other platform sizes. Please select 8031T999 and specify style number, platform size, and platform height.

Platform | Overall | Step | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Ht. (A) | Min. Ht. | Ground Clearance Ht. (B) | No. of Steps | Cap., lbs. | Ht. (C) | Wd. (D) | Dp. (E) | Wd. | Dp. | Assembled or Unassembled | Specifications Met | Each | |
Gray Powder-Coated Steel | |||||||||||||
36" Platform Wd. × 39" Platform Dp. | |||||||||||||
| 21" | 18" | 12 1/4" to 15 1/4" | 2 | 500 | 1'9" | 39" | 4' | 36" | 9 1/2" | Unassembled | Cal/OSHA Compliant Title 8 Section 3210, Cal/OSHA Compliant Title 8 Section 3273, OSHA Compliant 29 CFR 1910.23, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 000000 | 0000000 |

Platform | Overall | Step | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Ht. (A) | Min. Ht. | Ground Clearance Ht. (B) | No. of Steps | Cap., lbs. | Ht. (C) | Wd. (D) | Dp. (E) | Wd. | Dp. | Assembled or Unassembled | Specifications Met | Each | |
Gray Powder-Coated Steel | |||||||||||||
36" Platform Wd. × 39" Platform Dp. | |||||||||||||
| 21" | 18" | 12 1/4" to 15 1/4" | 2 | 500 | 5' | 39" | 4' | 36" | 9 1/2" | Unassembled | Cal/OSHA Compliant Title 8 Section 3210, Cal/OSHA Compliant Title 8 Section 3273, OSHA Compliant 29 CFR 1910.23, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 0000000 | 0000000 |
36" Platform Wd. × 77" Platform Dp. | |||||||||||||
| 21" | 18" | 12 1/4" to 15 1/4" | 2 | 500 | 5' | 39" | 7'2" | 36" | 9 1/2" | Unassembled | Cal/OSHA Compliant Title 8 Section 3210, Cal/OSHA Compliant Title 8 Section 3273, OSHA Compliant 29 CFR 1910.23, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 0000000 | 00000000 |

Platform | Overall | Step | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Ht. (A) | Min. Ht. | Ground Clearance Ht. (B) | No. of Steps | Cap., lbs. | Ht. (C) | Wd. (D) | Dp. (E) | Wd. | Dp. | Assembled or Unassembled | Specifications Met | Each | |
Gray Powder-Coated Steel | |||||||||||||
36" Platform Wd. × 39" Platform Dp. | |||||||||||||
| 21" | 18" | 12 1/4" to 15 1/4" | 2 | 500 | 5' | 39" | 4'9" | 36" | 9 1/2" | Unassembled | Cal/OSHA Compliant Title 8 Section 3210, Cal/OSHA Compliant Title 8 Section 3273, OSHA Compliant 29 CFR 1910.23, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 0000000 | 0000000 |
36" Platform Wd. × 77" Platform Dp. | |||||||||||||
| 21" | 18" | 12 1/4" to 15 1/4" | 2 | 500 | 5' | 39" | 7'11" | 36" | 9 1/2" | Unassembled | Cal/OSHA Compliant Title 8 Section 3210, Cal/OSHA Compliant Title 8 Section 3273, OSHA Compliant 29 CFR 1910.23, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 0000000 | 00000000 |

Platform | Overall | Step | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Ht. (A) | Min. Ht. | Ground Clearance Ht. (B) | No. of Steps | Cap., lbs. | Ht. (C) | Wd. (D) | Dp. (E) | Wd. | Dp. | Assembled or Unassembled | Specifications Met | Each | |
Gray Powder-Coated Steel | |||||||||||||
36" Platform Wd. × 39" Platform Dp. | |||||||||||||
| 21" | 18" | 12 1/4" to 15 1/4" | 2 | 500 | 5' | 39" | 4' | 36" | 9 1/2" | Unassembled | Cal/OSHA Compliant Title 8 Section 3210, Cal/OSHA Compliant Title 8 Section 3273, OSHA Compliant 29 CFR 1910.23, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 0000000 | 0000000 |
36" Platform Wd. × 77" Platform Dp. | |||||||||||||
| 21" | 18" | 12 1/4" to 15 1/4" | 2 | 500 | 5' | 39" | 7'2" | 36" | 9 1/2" | Unassembled | Cal/OSHA Compliant Title 8 Section 3210, Cal/OSHA Compliant Title 8 Section 3273, OSHA Compliant 29 CFR 1910.23, OSHA Compliant 29 CFR 1910.25, OSHA Compliant 29 CFR 1910.28 | 0000000 | 00000000 |

Overall | Step | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Platform Ht. (A) | Ground Clearance Ht. (B) | No. of Steps | Cap., lbs. | Ht. (C) | Wd. (D) | Dp. (E) | Wd. | Dp. | Assembled or Unassembled | Specifications Met | Each | |
Gray Painted Steel | ||||||||||||
30" Platform Wd. × 30" Platform Dp. | ||||||||||||
| 18" | 14" | 2 | 500 | 1'6" | 42" | 3'4" | 27" | 9 1/2" | Unassembled | Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25 | 0000000 | 000000000 |
30" Platform Wd. × 60" Platform Dp. | ||||||||||||
| 18" | 14" | 2 | 500 | 1'6" | 42" | 5'10" | 27" | 9 1/2" | Unassembled | Cal/OSHA Compliant Title 8 Section 3234, OSHA Compliant 29 CFR 1910.25 | 0000000 | 00000000 |

| For Style | For Platform Dp. | For No. of Steps | Each | |
Platform Connectors | ||||
|---|---|---|---|---|
| 2, 3, 4, 5 | 77" | 2, 3, 4 | 00000000 | 000000 |
Clean Room Work Platforms

Access elevated areas with these platforms that meet Fed. Std. Class 100 and ISO Class 5 clean room requirements. They are 316 stainless steel to withstand repeated washdowns. They also have a smooth finish and seamless welds, so there are no cracks or crevices that can harbor dust, dirt, and bacteria. Steps and platform are perforated to provide slip resistance. Easily move the platform with the four swivel casters. They’re spring loaded to stay stationary while in use—when you step on, the casters retract; when you step off, the casters roll again.
Note: The number of steps listed includes the platform.
Overall | Platform | Step | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ht. (A) | Wd. (B) | Dp. (C) | Wd. | Dp. | Ht. (D) | Ground Clearance Ht. (E) | Cap., lbs. | Wd. | Dp. | Tread | Wheel Configuration | Weight Actuation Type | No. of Wheel Brakes | Assembled or Unassembled | Environmental Rating | Each | |
316 Stainless Steel | |||||||||||||||||
| 4'9" | 36" | 4'9" | 33" | 49" | 1'9" | 1'8" | 300 | 34" | 9" | Perforated | Four Swivel Casters | Spring-Loaded Casters | 4 | Assembled | Fed. Std. Class 100, ISO Class 5 | 0000000 | 000000000 |
Rolling Work Platforms
Equipped with four casters, these platforms are easy to move between work areas. When you stand on these platforms, the spring-loaded casters automatically retract for a stable surface. Serrated treads give you maximum slip resistance and allow liquids and debris to pass through.
Style 3 have a handrail on only one side for unrestricted access to a conveyor or machinery.
Aluminum platforms are lighter weight than steel platforms and resist corrosion.
Note: Work platforms meet OSHA and Cal/OSHA dimensional and construction standards. Check local, state, and federal codes, including OSHA, for safe set up and operating practices.

Platform | Overall | Step | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Platform Ht. | Wd. | Dp. | Wd. (B) | Dp. (C) | Wd. | Dp. | Tread | Cap., lbs. | Wt., lbs. | Assembled or Unassembled | Wheel Configuration | Features | Specifications Met | Each | |
Aluminum | |||||||||||||||
50" Overall Ht. (A) | |||||||||||||||
| 1'8" | 24" | 24" | 28" | 46" | 24" | 10 1/2" | Serrated | 500 | 40 | Unassembled | Four Swivel Casters | Handrail, Nonskid Feet | Cal/OSHA Compliant Title 8 Section 3622, Cal/OSHA Compliant Title 8 Section 3626, Cal/OSHA Compliant Title 8 Section 3627, OSHA Compliant 29 CFR 1910 Subpart D, ANSI/ASSE A1264.1 | 000000 | 0000000 |
| 1'8" | 24" | 39 1/2" | 28" | 62" | 24" | 10 1/2" | Serrated | 500 | 50 | Unassembled | Four Swivel Casters | Handrail, Nonskid Feet | Cal/OSHA Compliant Title 8 Section 3622, Cal/OSHA Compliant Title 8 Section 3626, Cal/OSHA Compliant Title 8 Section 3627, OSHA Compliant 29 CFR 1910 Subpart D, ANSI/ASSE A1264.1 | 000000 | 000000 |
Low-Height Crossover Bridges

Take the safest, shortest route over pipes and other obstacles near the ground. For stability, bolt these bridges to your floor. The serrated steps and platform prevent slipping and allow liquids and debris to pass through.
Powder-coated steel bridges are both rust resistant and durable enough to withstand heavy use. They’re yellow, so they are easy to see and reduce tripping risks.
Aluminum bridges are more corrosion resistant than steel bridges. They’re a good choice for damp areas, including outdoors.
Note: All bridges meet OSHA and Cal/OSHA dimensional and construction standards. Check local, state, and federal codes, including OSHA, for safe set up and operating practices.
Overall | Ground Clearance | Platform | Step | Mounting Holes | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ht. (A) | Wd. (B) | Dp. (C) | Ht. (D) | Dp. (E) | Ht. | Wd. | Dp. | Wd. | Dp. | Cap., lbs. | No. of Steps | Mounting Hardware Included | No. of | Dia. | Assembled or Unassembled | Specifications Met | Each | |
Yellow Powder-Coated Steel | ||||||||||||||||||
Serrated Steps | ||||||||||||||||||
| 1'7" | 26 1/2" | 4'3" | 16" | 24 9/16" | 1'7" | 25 7/8" | 29" | 23 1/2" | 9 1/2" | 500 | 2 | No | 4 | 9/16" | Assembled | Cal/OSHA Compliant Title 8 Section 3622, OSHA Compliant 29 CFR 1910.23 | 0000000 | 0000000 |
Aluminum | ||||||||||||||||||
Serrated Steps | ||||||||||||||||||
| 1'7" | 26 1/2" | 4'3" | 16" | 24 9/16" | 1'7" | 25 7/8" | 29" | 23 1/2" | 9 1/2" | 300 | 2 | No | 4 | 9/16" | Assembled | Cal/OSHA Compliant Title 8 Section 3622, OSHA Compliant 29 CFR 1910.23 | 0000000 | 000000 |