McMaster-Carr logo
    Filter by
    Display Type
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Batteries Required
    DFARS Specialty Metals
    Connection End Shape
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Diagonal Screen Size
    Number of Wires
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    89 Products

    Fluke Wireless Remote-Reading Clamp-on-Jaw Current Meters

    Image of Product. Front orientation. Current Meters. Fluke Wireless Remote-Reading Clamp-on-Jaw Current Meters.
    Take current measurements from a distance with these high-quality, durable Fluke meters. They wirelessly transmit readings to a separate display. Because the jaws surround a cable, these meters are convenient for taking frequent measurements since you don't have to interrupt the circuit.
    The meters work with the Fluke 3000 FC multimeter, a computer with a Fluke pc3000 FC connector plugged in (not included), or a mobile device that has the Fluke Connect app.
    True RMS AC Calculation—These true RMS current meters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Display Count—Display count is an industry designation and not an actual value. For example, a 1,000-count meter shows numbers up to 999. A higher display count means the meter can give a more precise measurement.
    Mfr. Model
    No.
    Test End
    Component
    Jaw
    Opening
    Electrical Safety
    Rating
    Measures
    Max. AC Current,
    amp
    Data Log
    Cap.
    Display
    Count
    Includes
    Certification
    Batteries
    Included
    Each
    True RMS AC Calculation
    a3000 FCCurrent Clamp1.33"CAT III, 600VAC Current40065,0001,000CSA Certified, CSA-US Certified
    Yes7093K1210000000
    a3001 FCCurrent Loop10"CAT IV, 600VAC Current2,50065,0002,500Magnetic HangerCSA Certified, CSA-US Certified
    Yes7093K221000000
     

    Clamp-on-Jaw Current Meters

    Image of Product. Front orientation. Current Meters. Clamp-on-Jaw Current Meters.
    Measure current without interrupting the circuit—jaws surround a cable for testing, making these meters convenient for taking frequent measurements.
    Average-Sensing AC Calculation—These current meters are average sensing, so they take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors.
    Display Count—Display count is an industry designation and not an actual value. For example, a 2,000-count meter shows numbers up to 1,999. A higher display count means the meter can give a more precise measurement.
    Electrical Safety
    Rating
    AC Current
    Current
    Accuracy
    Measures
    Jaw
    Opening
    Includes
    Display
    Count
    Batteries
    Included
    Each
    Average-Sensing AC Calculation
    CAT III, 300V0 amp to 20 amp, 0 amp to 200 amp2% to 3%AC Current1.25"Carrying Case2,000Yes8264T110000000
     

    Fluke Clamp-on-Jaw Multimeters

    Image of Product. Front orientation. Multimeters. Fluke Clamp-on-Jaw Multimeters.
    Jaws surround a cable to test current without interrupting the circuit, making these high-quality, durable Fluke multimeters especially useful for testing high current. They include test leads to perform other electrical tests.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Multimeters with Calibration Certificate—Multimeters with calibration certificate include a document stating that they have passed a test for accuracy.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Multimeters
    Test Leads
    Multimeters
    Multimeters with
    Calibration Certificate
    Mfr. Model
    No.
    Jaw
    Opening
    Electrical Safety Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    amp
    Max. DC Current,
    amp
    Display
    Count
    Includes
    Each
    Each
    Pair
    True RMS AC Calculation
    3251.18"CAT III, 600V; CAT IV, 300VAC Current, AC Voltage, Capacitance, DC Voltage, Resistance, Temperature6006001%4006,000Carrying Case, Temperature Probe, Test Leads75085K56000000075085K66000000075085K98000000
    3552.3"CAT IV, 600VAC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance6001,0001%2,0002,00010,000Alligator Clips, Carrying Case, Test Leads, Test Probes75085K1100000000———0———0
    374 FC1.3"CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance1,0001,0001%6006006,000Carrying Case, Test Leads75085K3500000075085K81000000———0
    376 FC1.3"CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance1,0001,0001%2,500999.96,000Carrying Case, Flexible Current Loop, Test Leads75085K3600000075085K44000000———0
    3811.34"CAT IV, 600VAC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance1,0001,0001%2,500999.96,000Alligator Clips, Carrying Case, Flexible Current Loop, Removable Wireless Display, Test Leads75085K1300000075085K1600000000———0
     
    Multimeter Cases

    Clamp-On Multimeter Line Splitters

    Image of ProductInUse. Front orientation. Multimeter Line Splitters. Clamp-On Multimeter Line Splitters.
    Image of Product. Front orientation. Multimeter Line Splitters. Clamp-On Multimeter Line Splitters.
    Determine how much current a device with a two- or three-wire power cord uses without pulling apart the wires. The splitter isolates hot and neutral wires so you can measure AC current in either wire with a clamp-on multimeter.
    Max. AC Current,
    amp
    For No.
    of Wires
    Electrical Safety
    Rating
    Certification
    Each
    152, 3CAT II, 600VUL Listed, C-UL Listed
    7575K83000000

    Current-Sensing Test Leads

    Image of Product. Current Loop. Front orientation. Test Leads. Current-Sensing Test Leads, Current Loops.
    Image of Product. Current Clamp. Front orientation. Test Leads. Current-Sensing Test Leads, Current Clamp.

    Current Loop

    Current Clamp

    Measure current without interrupting the circuit by connecting these test leads to a multimeter or current meter.
    The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter or current meter.
    These test leads step down the sensed current to a level that works with a multimeter or current meter—the signal reduction ratio is the factor by which they reduce current.
    Test End
    For Max.
    Cord Dia.
    Connection End
    AC Current,
    amp
    DC Current,
    amp
    Current
    Accuracy
    Voltage Output Signal
    Per Amp Supplied
    For Current Range
    AC Voltage,
    V AC
    Electrical Safety
    Rating
    Freq. Range,
    kHz
    Jaw
    Opening
    Loop
    Opening
    Cord
    Lg.
    Batteries
    Req.
    Batteries
    Included
    Each
    Measures AC Current
    Flexible Current LoopSheathed Standard Banana Plug5 to 3,0001%10.000 mV AC, 1.000 mV AC, 1.000 mV DC5 amp to 300 amp
    50 amp to 3,000 amp
    1,000CAT IV, 600V5 to 407.6"78"YesYes7575K810000000
     
    Measures AC Current and DC Current
    Current Clamp1.22"Sheathed Standard Banana Plug0 to 1,0000 to 1,0001%1.000 mV AC, 1.000 mV DC0 amp to 200 amp
    0 amp to 1,000 amp
    300CAT III, 300V0 to 101.25"59"YesYes65775K79000000
     

    Meters for Solar Power Systems

    Find the best spot for new solar panels or check the performance of existing ones. These tools measure solar power in different ways, helping you comply with IEC 62446-1, a standard for testing, documenting, and maintaining solar panels connected to the grid. The data hold function freezes a measurement on the screen, so you have time to write it down. CE marked, all meet European safety standards.
    Solar Irradiance Meter Kits
    Image of Product. Front orientation. Light Meters. Meters for Solar Power Systems, Solar Irradiance Meter Kits.
    Solar irradiance meter kits include tools to measure current and voltage, so you can check if your panels are generating the expected power. To test current, position your panel’s wiring within the jaws of the clamp meter. Or, if your wiring is hard to reach or clamp around, attach the flexible AC probe to the clamp meter and loop it around your wiring. Neither method will interrupt your circuit, making frequent measurements possible. To measure voltage, wire the clamp meter’s test leads to your solar panel or power station.
    UV Light
    Current
    Range, amp
    Voltage
    Range
    Measuring Increments,
    W/m²
    Measurement
    Range, W/m²
    Measurement
    Accuracy
    Temp. Range
    AC
    DC
    AC, V AC
    DC, V DC
    Data Connection
    Batteries
    Included
    Features
    Includes
    Each
    10 to 1,400±5%-22° F to 212° F
    -30° C to 100° C
    0 to 999.90 to 999.90 to 1,0000 to 1,5003.5 mm Audio, BluetoothYesAngle Indicator, Compass, Data HoldTemperature Probe, Voltage/Current Clamp Meter (Rated CAT III 1500 V), 18" Lg. Flexible AC Probe, Magnetic Hanging Strap, Carrying Case7548N12000000000

    Current Conditioners

    Reduce high current flows to levels that work with panel monitors and other electrical measuring equipment.
    Feed-Through Housing
    Image of ProductInUse. Front orientation. Current Conditioners. Current Conditioners, Feed-Through Housing, Screw-Terminal Wire Connection.
    Image of ProductInUse. Front orientation. Current Conditioners. Current Conditioners, Feed-Through Housing, Wire Lead Connection.

    Screw-Terminal Wire

    Connection

    Wire Lead Connection

    Feed through conditioners with wire leads work with AC current.
    Mounting
    Holes
    ID
    Current Input:Current
    Output
    Input AC Current
    Output DC
    Voltage, V DC
    Output
    Current
    Operating DC
    Voltage, V DC
    Wire
    Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Fasteners
    Included
    Dia.
    No.
    of
    Certification
    Each
    Power Required
    0.74"0 amp to 2 amp, 0 amp to 5 amp4 mA to 20 mA24Screw Terminal2.18"3.5"0.93"0 to 120Yes0.19"2UL Listed, C-UL Listed
    6583K410000000
    0.74"0 amp to 10 amp, 0 amp to 20 amp, 0 amp to 50 amp4 mA to 20 mA24Screw Terminal2.18"3.5"0.93"0 to 120Yes0.19"2UL Listed, C-UL Listed
    6583K42000000
    0.74"0 amp to 100 amp, 0 amp to 150 amp, 0 amp to 200 amp4 mA to 20 mA24Screw Terminal2.18"3.5"0.93"0 to 120Yes0.19"2UL Listed, C-UL Listed
    6583K43000000
     
    Self-Powered
    0.74"0 amp to 10 amp, 0 amp to 20 amp, 0 amp to 50 amp0 to 5Screw Terminal2.18"3.5"0.93"0 to 120Yes0.19"2UL Listed, C-UL Listed
    6583K22000000
    0.74"0 amp to 10 amp, 0 amp to 20 amp, 0 amp to 50 amp0 to 10Screw Terminal2.18"3.5"0.93"0 to 120Yes0.19"2UL Listed, C-UL Listed
    6583K32000000
    0.74"0 amp to 100 amp, 0 amp to 150 amp, 0 amp to 200 amp0 to 5Screw Terminal2.18"3.5"0.93"0 to 120Yes0.19"2UL Listed, C-UL Listed
    6583K23000000
    0.74"0 amp to 100 amp, 0 amp to 150 amp, 0 amp to 200 amp0 to 10Screw Terminal2.18"3.5"0.93"0 to 120Yes0.19"2UL Listed, C-UL Listed
    6583K33000000
    1.13"100:50 amp to 5 ampWire Leads2.46"1.05"0 to 165UL Recognized Component, C-UL Recognized Component
    65795K8200000
    1.13"150:50 amp to 5 ampWire Leads2.46"1.05"0 to 165UL Recognized Component, C-UL Recognized Component
    65795K8400000
    1.13"200:50 amp to 5 ampWire Leads2.46"1.05"0 to 165UL Recognized Component, C-UL Recognized Component
    65795K8500000
    1.13"300:50 amp to 5 ampWire Leads2.46"1.05"0 to 165UL Recognized Component, C-UL Recognized Component
    65795K8700000
    1.13"50:50 amp to 5 ampWire Leads2.46"1.05"0 to 165UL Recognized Component, C-UL Recognized Component
    65795K7900000
    1.13"80:50 amp to 5 ampWire Leads2.46"1.05"0 to 165UL Recognized Component, C-UL Recognized Component
    65795K8100000
    2.5"1000:50 amp to 5 ampWire Leads4.7"1.1"0 to 165UL Recognized Component, C-UL Recognized Component
    65795K93000000
    2.5"1200:50 amp to 5 ampWire Leads4.7"1.1"0 to 165UL Recognized Component, C-UL Recognized Component
    65795K94000000
    2.5"1500:50 amp to 5 ampWire Leads4.7"1.1"0 to 165UL Recognized Component, C-UL Recognized Component
    65795K95000000
    2.5"500:50 amp to 5 ampWire Leads4.7"1.1"0 to 165UL Recognized Component, C-UL Recognized Component
    65795K9100000
    2.5"750:50 amp to 5 ampWire Leads4.7"1.1"0 to 165UL Recognized Component, C-UL Recognized Component
    65795K9200000
     
    Hinged Housing
    Image of ProductInUse. Front orientation. Current Conditioners. Current Conditioners, Hinged Housing.
    Hinged conditioners open so you can run a wire through them without cutting the power.
    Mounting
    Holes
    ID
    Input AC Current
    Output DC
    Voltage, V DC
    Output Current,
    mA
    Operating DC
    Voltage, V DC
    Wire
    Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Fasteners
    Included
    Dia.
    No.
    of
    Certification
    Each
    Power Required
    0.85"0 amp to 2 amp, 0 amp to 5 amp4 to 2024Screw Terminal2.25"3.53"1.19"0 to 120Yes0.19"2UL Listed, C-UL Listed
    6583K440000000
    0.85"0 amp to 10 amp, 0 amp to 20 amp, 0 amp to 50 amp4 to 2024Screw Terminal2.25"3.53"1.19"0 to 120Yes0.19"2UL Listed, C-UL Listed
    6583K45000000
    0.85"0 amp to 100 amp, 0 amp to 150 amp, 0 amp to 200 amp4 to 2024Screw Terminal2.25"3.53"1.19"0 to 120Yes0.19"2UL Listed, C-UL Listed
    6583K46000000
     
    Self-Powered
    0.85"0 amp to 10 amp, 0 amp to 20 amp, 0 amp to 50 amp0 to 5Screw Terminal2.25"3.53"1.19"0 to 120Yes0.19"2UL Listed, C-UL Listed
    6583K25000000
    0.85"0 amp to 10 amp, 0 amp to 20 amp, 0 amp to 50 amp0 to 10Screw Terminal2.25"3.53"1.19"0 to 120Yes0.19"2UL Listed, C-UL Listed
    6583K35000000
    0.85"0 amp to 100 amp, 0 amp to 150 amp, 0 amp to 200 amp0 to 5Screw Terminal2.25"3.53"1.19"0 to 120Yes0.19"2UL Listed, C-UL Listed
    6583K26000000
    0.85"0 amp to 100 amp, 0 amp to 150 amp, 0 amp to 200 amp0 to 10Screw Terminal2.25"3.53"1.19"0 to 120Yes0.19"2UL Listed, C-UL Listed
    6583K36000000
     

    Fluke Current-Sensing Test Leads

    Image of Product. Current Clamp. Front orientation. Test Leads. Fluke Current-Sensing Test Leads, Current Clamp.

    Current Clamp

    Measure current without interrupting the circuit by connecting these test leads to a multimeter or current meter.
    The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter or current meter.
    These test leads step down the sensed current to a level that works with a multimeter or current meter—the signal reduction ratio is the factor by which they reduce current.
    Mfr. Model
    No.
    Test End
    For Max.
    Cord Dia.
    Connection End
    AC Current,
    amp
    Current
    Accuracy
    Current Output Signal per
    amp Supplied, mA
    For Current
    Range
    AC Voltage,
    V AC
    Electrical Safety
    Rating
    Freq. Range
    Jaw
    Opening
    For Fluke Model No.
    Cord
    Lg.
    Batteries
    Req.
    Each
    Measures AC Current
    i400Current Clamp1.25"Sheathed Standard Banana Plug1 to 4002%1.0001 amp to 400 amp1,000CAT IV, 600V5 Hz to 20 kHz1.25"27 II, 28 II, 77IV, 83V, 87V, 179, 287, 289, 787, 789, 1577, 158759"No7575K660000000
     

    Current Indicating Rings

    Image of ProductInUse. Front orientation. Current Indicating Rings. Red Light.
    Image of ProductInUse. Front orientation. Current Indicating Rings. Wire Lead Connection.

    Red Light

    Wire Lead Connection

    Run current-carrying wires through these rings to monitor AC current flow.
    Red Light—Rings with a red light illuminate to indicate power.
    Wire Lead Connection—Rings with wire lead connections can monitor current from up to 200 ft. away when you attach a remote LED (not included) that illuminates when current is present.
    Current Indicating Rings
    Brackets
    Wire
    Lead
    AC Current,
    amp
    For Max.
    Wire Dia.
    Alert
    Type
    Wire
    Connection
    Requires
    Input Power
    Lg.
    Ga.
    Ht.
    Wd.
    Dp.
    Certification
    Each
    Each
    Measures AC Current
    2 to 1000.31"Red LightSelf-Powered1.29"0.46"0.95"6570K12000000———0
    2 to 1000.29"Wire LeadsRemote LEDSelf-Powered12"22
    1.04"0.46"0.95"C-UL Recognized Component, UL Recognized Component
    6570K600000———0
    2.5 to 1000.55"Wire LeadsRemote LEDSelf-Powered24"20
    1.49"0.52"1.33"C-UL Recognized Component, UL Recognized Component
    6570K9000006570K1100000
     
    Bulbs

    Fluke Test Lead Tips

    Image of Product. Front orientation. Test Lead Tips. Fluke Test Lead Tips.
    Adapt Fluke test leads to perform electrical tests in tight spaces. Attach these tips to test leads that have 4 mm banana plugs.
    Test End
    Mfr. Model
    No.
    For Fluke Model No.
    Test End
    Component
    Connection End
    AC Voltage,
    V AC
    DC Voltage,
    V DC
    Current,
    amp
    Electrical Safety
    Rating
    Color
    Material
    Insulation
    Material
    Pair
    TP183V, 87V, 175, 177, 179, 373, 374, 376, 381, 787, 789, T+PRO, T5-1000, T5-600Needle TipStandard Banana Jack1,0001,00010CAT II, 1,000VBlack, RedStainless Steel
    Polypropylene
    7053K61000000

    Clamp-on-Jaw Multimeters

    Image of Product. Front orientation. Multimeters. Clamp-on-Jaw Multimeters.
    Suitable for testing high current, these multimeters have jaws that surround a cable to test without interrupting the circuit. They include test leads to perform other electrical tests.
    Average-Sensing AC Calculation—Average-sensing multimeters take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors.
    True RMS AC Calculation—True RMS multimeters take accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
    Display Count—Display count is an industry designation and not an actual value. For example, a 6,000-count multimeter shows numbers up to 5,999. A higher display count means the multimeter can give a more precise measurement.
    Multimeters
    Test Leads
    Jaw
    Opening
    Electrical Safety
    Rating
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    amp
    Max. DC Current,
    amp
    Display
    Count
    Includes
    Each
    Pair
    Average-Sensing AC Calculation
    1"CAT III, 600VAC Current, AC Voltage, Capacitance, DC Voltage, Frequency, Resistance, Temperature6006001%6004,000Carrying Case, Temperature Probe, Test Leads7508K1400000007574K51000000
     
    True RMS AC Calculation
    1.18"CAT III, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature7501,0000.8%6006006,000Temperature Probe, Test Leads7508K130000007508K6600000
    1.18"CAT IV, 300VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance6006001%6006006,000Carrying Case, Test Leads7508K710000007420K4400000
    1.7"CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Voltage, Frequency, Resistance, Temperature1,0001,0001.5%1,0006,000Built-In Infrared Temperature Sensor, Carrying Case, Test Leads7508K190000007508K6600000
    1.7"CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance, Temperature1,0001,0002.0%1,0001,0006,000Built-In Infrared Temperature Sensor, Carrying Case, Temperature Probe, Test Leads7508K150000007508K6600000
    2"CAT IV, 600VAC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Frequency, Resistance1,0001,0000.8%1,0001,0006,000Carrying Case, Test Leads7508K730000007420K4400000
     

    High-Current-Monitoring Relays

    Image of ProductInUse. Front orientation. Monitoring Relays. High-Current-Monitoring Relays.
    Prevent AC current overload in equipment such as motors and heaters.
    These relays sense current flowing through wires routed through the opening. If the current exceeds a set trip point, the relay trips and starts the adjustable delay timer. After the timer's cycle, the relay cuts power to the equipment to protect against overload. Once current drops below the trip point, the relay allows power to flow again to the equipment.
    To determine the current trip range for more than one wire, divide the listed trip range by the number of wires passed through the opening.
    Current Trip for One
    Wire Range, amp
    Switch
    Designation
    Resistive Load Current
    @ AC Voltage
    Delay Time
    Range, sec.
    For Max.
    Wire Dia.
    Ht.
    Wd.
    Dp.
    Input AC
    Voltage, V AC
    Wire Connection
    Certification
    Mount
    Type
    Fasteners
    Included
    Mounting
    Hole Dia.
    No. of Mounting
    Holes
    Each
    Measures AC Current
    0.1 to 1SPDT
    10 amp @ 240V AC0.5 to 60.5"2.13"3.5"2.5"120Quick-Disconnect TerminalUL Recognized Component
    Screw OnNo0.19"265795K690000000
    1 to 10SPDT
    10 amp @ 240V AC0.5 to 60.5"2.13"3.5"2.5"120Quick-Disconnect TerminalC-UL Recognized Component, UL Recognized Component
    Screw OnNo0.19"265795K71000000
    3 to 30SPDT
    10 amp @ 240V AC0.5 to 60.5"2.13"3.5"2.5"120Quick-Disconnect TerminalC-UL Recognized Component, UL Recognized Component
    Screw OnNo0.19"265795K72000000
    6 to 60SPDT
    10 amp @ 240V AC0.5 to 60.5"2.13"3.5"2.5"120Quick-Disconnect TerminalC-UL Recognized Component, UL Recognized Component
    Screw OnNo0.19"265795K73000000
    10 to 100SPDT
    10 amp @ 240V AC0.5 to 60.5"2.13"3.5"2.5"120Quick-Disconnect TerminalC-UL Recognized Component, UL Recognized Component
    Screw OnNo0.19"265795K74000000
     

    Analog Clamp-on-Jaw Multimeters

    Image of Product. Front orientation. Multimeters. Analog Clamp-on-Jaw Multimeters.
    Measure rapidly changing electrical values more easily than with digital multimeters. Convenient for taking frequent high current measurements, the meters have jaws that surround a cable to test current without interrupting the circuit. Use the included test leads to perform other electrical tests.
    Average-Sensing AC Calculation—Average-sensing multimeters take accurate AC measurements when testing equipment that has a linear load and draws current in a smooth sine wave, such as standard induction motors.
    Batteries
    Jaw
    Opening
    Measures
    Max. AC Voltage,
    V AC
    Max. DC Voltage,
    V DC
    DC Voltage
    Accuracy
    Max. AC Current,
    amp
    Hardware Features
    Includes
    Size
    Req.
    Each
    Average-Sensing AC Calculation
    1.5"AC Current, AC Voltage, DC Voltage, Resistance600604%600Overload ProtectionTest LeadsAAYes7615K570000000
     
    Batteries

    Fluke Test Lead Sets

    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number FTPL-1.
    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL175.

    Model Number FTPL-1

    Model Number TL175

    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL222.
    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL224.

    Model Number TL222

    Model Number TL224

    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL26A.
    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL27.

    Model Number TL26A

    Model Number TL27

    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL28A.
    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL40.

    Model Number TL28A

    Model Number TL40

    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL71.
    Image of Product. Front orientation. Exploded view. Test Leads. Fluke Test Lead Sets, Model Number TL75.

    Model Number TL71

    Model Number TL75

    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL76.
    Image of Product. Front orientation. Test Leads. Fluke Test Lead Sets, Model Number TL910.

    Model Number TL76

    Model Number TL910

    Connect to Fluke multimeters with a set of red and black test leads.
    The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter.
    Mfr. Model
    No.
    For Fluke Model No.
    Test End
    Connection End
    AC Voltage,
    V AC
    DC Voltage,
    V DC
    Current,
    amp
    Electrical Safety Rating
    Certification
    No. of
    Cords
    Cord
    Lg.
    Color
    Test End Material
    Pair
    FTPL-1289Notched Threaded Probe TipSheathed Standard Banana Plug1,0001,00010CAT IV, 600VCSA Certified, CSA-US Certified
    248"Black, RedNickel-Plated Brass7093K1250000000
    TL17577IV, 113, 114, 115, 116, 117, 175, 177, 179, 233, 287, 289Notched Threaded Probe TipSheathed Standard Banana Plug1,0001,00010CAT IV, 600VCSA Certified, CSA-US Certified
    248"Black, RedNickel-Plated Brass7093K12300000
    TL22283V, 87V, 787Sheathed Banana PlugSheathed Standard Banana Plug1,0001,00010CAT III, 1,000V; CAT IV, 600VCSA Certified, CSA-US Certified
    260"Black, RedCopper7093K12700000
    TL22487V, 107, 179, 233, 287, 3000Sheathed Banana PlugSheathed Standard Banana Plug1,0001,00010CAT III, 1,000V; CAT IV, 600VCSA Certified, CSA-US Certified
    260"Black, RedCopper7093K12800000
    TL26A83V, 87V, 88V/A, 107, 179, 287, 289Serrated Alligator ClipSheathed Standard Banana Plug30308CSA Certified, CSA-US Certified
    260"Black, RedNickel-Plated Copper7093K12900000
    TL27107, 175, 177, 179, 787Sheathed Banana PlugSheathed Standard Banana Plug1,0001,00010CAT III, 1,000VCSA Certified, CSA-US Certified
    260"Black, RedCopper7093K13100000
    TL28A88V/A, 107, 175, 177, 179, 287, 289Serrated Alligator ClipSheathed Standard Banana Plug303010CAT I, 30VCSA Certified, CSA-US Certified
    260"Black, RedCopper7093K13200000
    TL4083V, 87V, 88V/A, 287, 289, 787Retractable Probe TipSheathed Standard Banana Plug6006003CAT II, 600VCSA Certified, CSA-US Certified
    248"Black, RedStainless Steel7093K13300000
    TL7127 II, 28 II, 83V, 87V, 88V, 114, 115, 116, 117, 175, 177, 179, 233, 787, 789Notched Probe TipSheathed Standard Banana Plug1,0001,00010CAT IV, 600VCSA Certified, CSA-US Certified
    248"Black, RedNickel-Plated Brass7093K12400000
    TL7583V, 87V, 113, 175, 177, 179, 287, 289, 787, 789Notched Probe TipSheathed Standard Banana Plug1,0001,00010CAT IV, 600VCSA Certified, CSA-US Certified
    248"Black, RedNickel-Plated Brass75085K9800000
    TL7687V, 107, 179, 287, 289, 787Pointed Threaded Probe TipSheathed Standard Banana Plug1,0001,00010CAT II, 1,000VCSA Certified, CSA-US Certified
    248"Black, RedNickel-Plated Brass7093K13400000
    TL91083V, 87V, 287, 289, 787Pointed Probe TipSheathed Standard Banana Plug1,0001,0003CAT II, 1,000VCSA Certified, CSA-US Certified
    240"Black, RedGold-Plated Copper7093K12600000

    DIN-Rail Mount Current Conditioners

    Image of ProductInUse. Front orientation. Current Conditioners. DIN-Rail Mount Current Conditioners.
    Ready to mount on DIN rail, these conditioners reduce high AC current, creating an output signal that can be used by panel monitors and other electrical measuring equipment.
    They have true RMS sensing capability for accurate readings of the AC input current.
    Mounting
    Holes
    Input AC
    Current, amp
    Output Current,
    mA
    Output DC
    Voltage, V DC
    Operating DC
    Voltage, V DC
    ID
    AC
    Calculation
    Wire
    Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Fasteners
    Included
    Dia.
    No.
    of
    Electrical Safety
    Rating
    Certification
    Each
    Feed-Through Housing
    0 to 100 to 5240.79"True RMSScrew Terminal2.99"1.42"3.27"32 to 140No0.14"2CAT II, 600VUL Recognized Component, C-UL Recognized Component
    6733T1110000000
    0 to 104 to 20240.79"True RMSScrew Terminal2.99"1.42"3.27"32 to 140No0.14"2CAT II, 600VUL Recognized Component, C-UL Recognized Component
    6733T121000000
    0 to 200 to 5240.79"True RMSScrew Terminal2.99"1.42"3.27"32 to 140No0.14"2CAT II, 600VUL Recognized Component, C-UL Recognized Component
    6733T112000000
    0 to 204 to 20240.79"True RMSScrew Terminal2.99"1.42"3.27"32 to 140No0.14"2CAT II, 600VUL Recognized Component, C-UL Recognized Component
    6733T122000000
    0 to 500 to 5240.79"True RMSScrew Terminal2.99"1.42"3.27"32 to 140No0.14"2CAT II, 600VUL Recognized Component, C-UL Recognized Component
    6733T113000000
    0 to 504 to 20240.79"True RMSScrew Terminal2.99"1.42"3.27"32 to 140No0.14"2CAT II, 600VUL Recognized Component, C-UL Recognized Component
    6733T123000000
    0 to 1000 to 5240.79"True RMSScrew Terminal2.99"1.42"3.27"32 to 140No0.14"2CAT II, 600VUL Recognized Component, C-UL Recognized Component
    6733T114000000
    0 to 1004 to 20240.79"True RMSScrew Terminal2.99"1.42"3.27"32 to 140No0.14"2CAT II, 600VUL Recognized Component, C-UL Recognized Component
    6733T124000000
     

    Current-Monitoring Relays

    Image of Product. Front orientation. Contains Annotated. Monitoring Relays. Current-Monitoring Relays, Screw Terminals, Knob Adjustment.
    Image of Product. Front orientation. Contains Annotated. Monitoring Relays. Current-Monitoring Relays, Screw Terminals with IO Link, Keypad Adjustment.
    Image of Product. Front orientation. Contains Annotated. Monitoring Relays. Current-Monitoring Relays, Spring-Clamp Terminals with IO Link, Keypad Adjustment.

    Screw Terminals

    Knob Adjustment

    Screw Terminals

    with IO Link,

    Keypad Adjustment

    Spring-Clamp

    Terminals with IO

    Link, Keypad

    Adjustment

    Protect electrical equipment from overcurrent and undercurrent damage—these relays continuously monitor current flow. When current is outside a set range, they trip and cut power to prevent overheating, fire hazards, and stalling. Rated IP20, these relays have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on a 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
    Spring-Clamp-Terminal Wire Connection—Relays with spring-clamp terminals connect and disconnect to wire without screws. Because there’s no screw, these connections are less likely to loosen over time, even in high-vibration environments.
    IO Link Communication Protocol—Relays with IO link can be programmed, monitored, and reset remotely by connecting them to a programmable logic controller (PLC), human-machine interface (HMI), or computer. If you want to program them locally, they have a keypad.
    Knob Adjustment—Relays with knob adjustments have knobs right on the front where you can set your trip current. You can see that they're wired correctly and when they're actuated based on the LED indicators.
    No. of
    Terminals
    Input Voltage
    Trip Current Setting, amp
    Trip Current,
    amp
    Trip Time,
    sec.
    Reset Type
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Adjustment Mechanism
    Ht.
    Wd.
    Dp.
    Digital Display
    Type
    Each
    Screw Terminals
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    924V AC, 24V DC0.1 to 1, 0.5 to 5, 0.8 to 80.1 to 30Automatic, Manual5 amp @ 240V AC
    5 amp @ 30V DC
    250V AC
    30V DC
    Knob3.5"0.9"3.9"8123N140000000
    9120V AC, 240V AC0.1 to 1, 0.5 to 5, 0.8 to 80.1 to 30Automatic, Manual5 amp @ 240V AC
    5 amp @ 30V DC
    250V AC
    30V DC
    Knob3.5"0.9"3.9"8123N13000000
     
    Screw Terminals with IO Link
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    924V DC0.05 to 100 to 999Automatic3 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad3.6"0.9"3.4"LCD8123N11000000
     
    Spring-Clamp Terminals with IO Link
     
    1 Circuit Controlled with 1 Off or 1 On—SPDT
    924V DC0.05 to 100 to 999Automatic3 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad3.8"0.9"3.4"LCD8123N12000000
     
    back to top