For a perfect fit in a thermowell, trim these probes with a pipe cutter. Stainless steel protects the sensing element from impact and liquids when they’re immersed. They are often installed in a bore to measure the temperature of molds, dies, and other equipment.
Probe | Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, ° F | Lg. | Dia. | Cuttable Lg. | Accuracy | Response Time, sec. | Connection Type | Sensing Tip Lg. | Sensing Element Material | Lead Lg. | Gauge | No. of Wires | Each | |
304 Stainless Steel Probe | ||||||||||||||
100 ohms | -55° to 400° | 12" | 3/16" | 8 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 0000000 |
100 ohms | -55° to 400° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 400° | 24" | 3/16" | 20 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 400° | 24" | 1/4" | 20 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
100 ohms | -55° to 400° | 48" | 1/4" | 44 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
100 ohms | -55° to 400° | 72" | 1/4" | 68 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 400° | 96" | 1/4" | 92 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 12" | 3/16" | 8 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 24" | 3/16" | 20 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 24" | 1/4" | 20 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
100 ohms | -55° to 900° | 48" | 1/4" | 44 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
Dual-Output Cut-to-Length RTD Probes for Liquids and Gases

Output temperature readings to two devices, or in applications where you want to output temperature readings to two different devices. For example, the output from one thermocouple might be fed to a data logger, while the output from the other thermocouple is used for process control.
Probe | Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Cuttable Lg. | Accuracy | Response Time, sec. | Connection Type | Sensing Tip Lg. | Sensing Element Material | Lead Lg. | Gauge | No. of Wires | Each | |
304 Stainless Steel Probe | ||||||||||||||
100 ohms | -55° to 400° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 6 | 000000000 | 0000000 |
100 ohms | -55° to 400° | 24" | 1/4" | 20 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 6 | 000000000 | 000000 |
100 ohms | -55° to 900° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 6 | 000000000 | 000000 |