Filter by
Return Type
Direction of Operation
Rotation
Export Control Classification Number (ECCN)
REACH
DFARS Specialty Metals
Proportional HVAC Duct Damper Actuators
![]() |
This actuator provides better control than incremental actuators because it is constantly being positioned in response to duct airflow requirements. Use to automatically adjust dampers to regulate airflow. It attaches to the damper shaft to rotate it open and closed when signaled by a controller (not included). Actuator can be set to return the damper to an open or closed position if the power fails. Use the crank for precise adjustments.
For Max. Damper Shaft | Overall | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Torque, in·lbf | Voltage | Current, amp | Control Signal | Electrical Connection Permanence | Dia. | Ht. | Wd. | Material | Direction of Operation | Rotation Range | Ht. | Wd. | Dp. | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
With Spring Return | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
177 | 24V AC/24V DC | 0.7 | 0V DC to 10V DC/0 mA to 20 mA | Hardwire | 3/4" | 1/2" | 1/2" | Aluminum | Clockwise, Counterclockwise | 30° to 90° | 10 3/8" | 4" | 3 1/4" | 1742K82 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Incremental and Proportional HVAC Duct Damper Actuators
![]() |
Actuators automatically switch between incremental and proportional control to adjust dampers to regulate airflow. Actuators attach to the damper shaft to rotate it open and closed when signaled by a controller (not included).
For Max. Damper Shaft | Overall | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Torque, in·lbf | Voltage | Current, amp | Electrical Connection Permanence | Dia. | Ht. | Wd. | Material | Direction of Operation | Rotation Range | Ht. | Wd. | Dp. | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Without Spring Return | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
90 | 24V AC/24V DC | 0 | Hardwire | 1 1/16" | 3/4" | 3/4" | Plastic | Clockwise, Counterclockwise | 35° to 95° | 6 5/8" | 3 1/4" | 2 1/2" | 1742K91 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
180 | 24V AC/24V DC | 0 | Hardwire | 1 1/16" | 3/4" | 3/4" | Plastic | Clockwise, Counterclockwise | 35° to 95° | 7 7/8" | 4" | 2 5/8" | 1742K92 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
310 | 24V AC/24V DC | 0 | Hardwire | 1 1/16" | 3/4" | 3/4" | Plastic | Clockwise, Counterclockwise | 35° to 95° | 7 7/8" | 4" | 2 5/8" | 1742K93 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Incremental HVAC Duct Damper Actuators
![]() |
When duct airflow varies from the setpoint, these actuators open and close until the system requirement is restored. Use to automatically adjust dampers to regulate airflow. Actuators attach to the damper shaft to rotate it open and closed when signaled by a controller (not included).
For Max. Damper Shaft | Overall | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Torque, in·lbf | Voltage, V AC | Current, amp | Electrical Connection Permanence | Dia. | Ht. | Wd. | Material | Direction of Operation | Rotation Range | Ht. | Wd. | Dp. | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Without Spring Return | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
35 | 24 | 0.1 | Hardwire | 1/2" | 3/8" | 3/8" | Plastic | Clockwise, Counterclockwise | 0° to 90° | 5 1/8" | 2 3/4" | 2 1/4" | 1742K16 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||