About Electric Motors
When replacing a motor, use the information on your motor’s nameplate to guide your selection.
More
DC Gearmotors



Convert speed to torque to get the power you need—gearmotors are a motor and speed reducer in one. You can wire for clockwise or counterclockwise rotation; instructions are included. Gearmotors transmit motion inline with the motor.
To control motor speed, motor controls are also available. To convert AC power to DC power, see AC to DC transformers.
For technical drawings and 3-D models, click on a part number.
Overall | Shaft | Insulation | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Speed @ Continuous Operating Torque | Full Load Current, A | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max. Temp., ° F | Each | |
90 Volts DC | |||||||||||||
1/17 | 30 rpm @ 100 in.-lbs. | 0.8 | Totally Enclosed Nonventilated (TENV) | 8 3/4" | 4 1/2" | 5 1/2" | 1/2" | 1" | 3" | F | 311° | 0000000 | 0000000 |
1/17 | 60 rpm @ 56 in.-lbs. | 0.8 | Totally Enclosed Nonventilated (TENV) | 8 3/4" | 4 1/2" | 5 1/2" | 1/2" | 1" | 3" | F | 311° | 0000000 | 000000 |
1/17 | 100 rpm @ 36 in.-lbs. | 0.8 | Totally Enclosed Nonventilated (TENV) | 8 3/4" | 4 1/2" | 5 1/2" | 1/2" | 1" | 3" | F | 311° | 0000000 | 000000 |
1/17 | 150 rpm @ 24 in.-lbs. | 0.8 | Totally Enclosed Nonventilated (TENV) | 8 1/2" | 4 1/2" | 5 1/2" | 1/2" | 1" | 3" | F | 311° | 0000000 | 000000 |
1/17 | 300 rpm @ 10 in.-lbs. | 0.8 | Totally Enclosed Nonventilated (TENV) | 8 1/2" | 4 1/2" | 5 1/2" | 1/2" | 1" | 3" | F | 311° | 0000000 | 000000 |
1/8 | 31 rpm @ 220 in.-lbs. | 1.3 | Totally Enclosed Nonventilated (TENV) | 11 1/2" | 5" | 5 1/4" | 5/8" | 1 1/2" | 3 1/2" | F | 311° | 0000000 | 000000 |
1/8 | 51 rpm @ 130 in.-lbs. | 1.3 | Totally Enclosed Nonventilated (TENV) | 11 1/2" | 5" | 6 1/4" | 5/8" | 1 1/2" | 3 1/2" | F | 311° | 0000000 | 000000 |
1/8 | 61 rpm @ 113 in.-lbs. | 1.3 | Totally Enclosed Nonventilated (TENV) | 11 1/2" | 5" | 5 1/4" | 5/8" | 1 1/2" | 3 1/2" | F | 311° | 0000000 | 000000 |
1/8 | 94 rpm @ 77 in.-lbs. | 1.3 | Totally Enclosed Nonventilated (TENV) | 11 1/2" | 5" | 5 1/4" | 5/8" | 1 1/2" | 3 1/2" | F | 311° | 0000000 | 000000 |
1/8 | 167 rpm @ 43 in.-lbs. | 1.3 | Totally Enclosed Nonventilated (TENV) | 11 1/2" | 5" | 5 1/4" | 5/8" | 1 1/2" | 3 1/2" | F | 311° | 0000000 | 000000 |
1/4 | 42 rpm @ 280 in.-lbs. | 2.3 | Totally Enclosed Nonventilated (TENV) | 13 1/4" | 6" | 5 1/2" | 3/4" | 1 5/8" | 4" | F | 311° | 0000000 | 000000 |
1/4 | 62 rpm @ 220 in.-lbs. | 2.3 | Totally Enclosed Nonventilated (TENV) | 13 1/4" | 6" | 5 1/2" | 3/4" | 1 5/8" | 4" | F | 311° | 0000000 | 000000 |
1/4 | 83 rpm @ 155 in.-lbs. | 2.3 | Totally Enclosed Nonventilated (TENV) | 13 1/4" | 6" | 5 1/2" | 3/4" | 1 5/8" | 4" | F | 311° | 0000000 | 000000 |
1/4 | 110 rpm @ 100 in.-lbs. | 2 | Totally Enclosed Nonventilated (TENV) | 13 1/4" | 6" | 5 1/2" | 3/4" | 1 5/8" | 4" | F | 311° | 0000000 | 000000 |
1/4 | 165 rpm @ 70 in.-lbs. | 2 | Totally Enclosed Nonventilated (TENV) | 13 1/4" | 6" | 5 1/2" | 3/4" | 1 5/8" | 4" | F | 311° | 0000000 | 000000 |
1/2 | 17 rpm @ 1,112 in.-lbs. | 5 | Totally Enclosed Fan Cooled (TEFC) | 16 1/2" | 8 1/4" | 6 1/2" | 3/4" | 1 1/2" | 3" | F | 311° | 0000000 | 000000 |
1/2 | 30 rpm @ 822 in.-lbs. | 5 | Totally Enclosed Fan Cooled (TEFC) | 16 1/2" | 8 1/4" | 6 1/2" | 3/4" | 1 1/2" | 3" | F | 311° | 0000000 | 000000 |
1/2 | 39 rpm @ 705 in.-lbs. | 5 | Totally Enclosed Fan Cooled (TEFC) | 16 1/2" | 8 1/4" | 6 1/2" | 3/4" | 1 1/2" | 3" | F | 311° | 0000000 | 000000 |
1/2 | 57 rpm @ 476 in.-lbs. | 5 | Totally Enclosed Fan Cooled (TEFC) | 16 1/2" | 8 1/4" | 6 1/2" | 3/4" | 1 1/2" | 3" | F | 311° | 0000000 | 000000 |
1/2 | 84 rpm @ 320 in.-lbs. | 5 | Totally Enclosed Fan Cooled (TEFC) | 16 1/2" | 8 1/4" | 6 1/2" | 3/4" | 1 1/2" | 3" | F | 311° | 0000000 | 000000 |
Right-Angle DC Gearmotors



A good solution for tight spaces, these gearmotors transmit motion at a 90° angle from the motor, so they’re positioned alongside your application when mounted. Gearmotors combine a motor and speed reducer to lower speed and increase torque.
To control motor speed, motor controls are also available. To convert AC power to DC power, see AC to DC transformers.
For technical drawings and 3-D models, click on a part number.
Gearmotors | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Shaft | Insulation | Optional Conduit Boxes | Replacement Motor Brushes | |||||||||||||
Power, hp | Speed @ Continuous Operating Torque | Full Load Current, A | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max. Temp., ° F | Each | Each | Each | |||
90 Volts DC | |||||||||||||||||
1/17 | 42 rpm @ 22 in.-lbs. | 0.9 | Totally Enclosed Nonventilated (TENV) | 8 3/4" | 4" | 3 3/4" | 1/2" | 1.3" | 1.3" | H | 356° | 00000000 | 0000000 | 00000000 | 000000 | 000000000 | 000000 |
1/17 | 62 rpm @ 19 in.-lbs. | 0.9 | Totally Enclosed Nonventilated (TENV) | 8 3/4" | 4" | 3 3/4" | 1/2" | 1.3" | 1.3" | H | 356° | 00000000 | 000000 | 00000000 | 00000 | 000000000 | 00000 |
1/17 | 116 rpm @ 16 in.-lbs. | 0.9 | Totally Enclosed Nonventilated (TENV) | 8 3/4" | 4" | 3 3/4" | 1/2" | 1.3" | 1.3" | H | 356° | 00000000 | 000000 | 00000000 | 00000 | 000000000 | 00000 |
1/17 | 222 rpm @ 10 in.-lbs. | 1 | Totally Enclosed Nonventilated (TENV) | 8 3/4" | 4" | 3 3/4" | 1/2" | 1.3" | 1.3" | H | 356° | 00000000 | 000000 | 00000000 | 00000 | 000000000 | 00000 |
1/17 | 445 rpm @ 5 in.-lbs. | 1 | Totally Enclosed Nonventilated (TENV) | 8 3/4" | 4" | 3 3/4" | 1/2" | 1.3" | 1.3" | H | 356° | 00000000 | 000000 | 00000000 | 00000 | 000000000 | 00000 |
1/8 | 42 rpm @ 80 in.-lbs. | 1.4 | Totally Enclosed Nonventilated (TENV) | 10 3/4" | 5 1/4" | 4 3/4" | 5/8" | 1.8" | 1.67" | H | 356° | 00000000 | 000000 | 00000000 | 00000 | 000000000 | 00000 |
1/8 | 62 rpm @ 70 in.-lbs. | 1.4 | Totally Enclosed Nonventilated (TENV) | 10 3/4" | 5 1/4" | 4 3/4" | 5/8" | 1.8" | 1.67" | H | 356° | 00000000 | 000000 | 00000000 | 00000 | 000000000 | 00000 |
1/8 | 122 rpm @ 45 in.-lbs. | 1.4 | Totally Enclosed Nonventilated (TENV) | 10 3/4" | 5 1/4" | 4 3/4" | 5/8" | 1.8" | 1.67" | H | 356° | 00000000 | 000000 | 00000000 | 00000 | 000000000 | 00000 |
1/8 | 237 rpm @ 25 in.-lbs. | 1.4 | Totally Enclosed Nonventilated (TENV) | 10 3/4" | 5 1/4" | 4 3/4" | 5/8" | 1.8" | 1.67" | H | 356° | 00000000 | 000000 | 00000000 | 00000 | 000000000 | 00000 |
1/8 | 475 rpm @ 13 in.-lbs. | 1.4 | Totally Enclosed Nonventilated (TENV) | 10 3/4" | 5 1/4" | 4 3/4" | 5/8" | 1.8" | 1.67" | H | 356° | 00000000 | 000000 | 00000000 | 00000 | 000000000 | 00000 |
1/4 | 60 rpm @ 135 in.-lbs. | 2.3 | Totally Enclosed Nonventilated (TENV) | 12 3/4" | 5 1/4" | 4 3/4" | 5/8" | 1.8" | 1.67" | H | 356° | 00000000 | 000000 | 00000000 | 00000 | 000000000 | 00000 |
1/4 | 79 rpm @ 125 in.-lbs. | 2.3 | Totally Enclosed Nonventilated (TENV) | 12 3/4" | 5 1/4" | 4 3/4" | 5/8" | 1.8" | 1.67" | H | 356° | 00000000 | 000000 | 00000000 | 00000 | 000000000 | 00000 |
1/4 | 120 rpm @ 90 in.-lbs. | 2.3 | Totally Enclosed Nonventilated (TENV) | 12 3/4" | 5 1/4" | 4 3/4" | 5/8" | 1.8" | 1.67" | H | 356° | 00000000 | 000000 | 00000000 | 00000 | 000000000 | 00000 |
1/4 | 233 rpm @ 50 in.-lbs. | 2.3 | Totally Enclosed Nonventilated (TENV) | 12 3/4" | 5 1/4" | 4 3/4" | 5/8" | 1.8" | 1.67" | H | 356° | 00000000 | 000000 | 00000000 | 00000 | 000000000 | 00000 |
1/4 | 465 rpm @ 30 in.-lbs. | 2.3 | Totally Enclosed Nonventilated (TENV) | 12 3/4" | 5 1/4" | 4 3/4" | 5/8" | 1.8" | 1.67" | H | 356° | 00000000 | 000000 | 00000000 | 00000 | 000000000 | 00000 |
Compact Square-Face DC Gearmotors



Drive low-speed, high-torque applications in small spaces. Gearmotors combine a motor and speed reducer to lower speed and increase torque. Wire for clockwise or counterclockwise rotation.
Use a motor speed control (not included) to adjust the motor speed.
To convert AC power to DC power, see AC to DC transformers.
For technical drawings and 3-D models, click on a part number.
Overall | Shaft | Insulation | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Speed @ Continuous Operating Torque | Power, hp | Full Load Current, A | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max. Temp., ° F | Each | |
12 Volts DC | ||||||||||||
0.6 rpm @ 800 in.-oz. | 0.0003 | 0.1 | 3 1/4" | 2 3/4" | 3" | 5/16" | 1" | 1.43" | B | 266° | 0000000 | 000000 |
1.3 rpm @ 800 in.-oz. | 0.001 | 0.5 | 3 1/2" | 2 3/4" | 3" | 5/16" | 1" | 1.43" | B | 266° | 0000000 | 00000 |
4 rpm @ 640 in.-oz. | 0.0025 | 0.7 | 3 1/4" | 2 3/4" | 3" | 5/16" | 1" | 1.43" | B | 266° | 0000000 | 00000 |
8 rpm @ 640 in.-oz. | 0.005 | 0.7 | 4" | 2 3/4" | 3" | 5/16" | 1" | 1.43" | B | 266° | 0000000 | 00000 |
12 rpm @ 640 in.-oz. | 0.0077 | 1.3 | 3 1/2" | 2 3/4" | 3" | 5/16" | 1" | 1.43" | B | 266° | 0000000 | 00000 |
16 rpm @ 400 in.-oz. | 0.0067 | 1.4 | 3 1/2" | 2 3/4" | 3" | 5/16" | 1" | 1.43" | B | 266° | 0000000 | 00000 |
25 rpm @ 320 in.-oz. | 0.008 | 1.3 | 3 1/2" | 2 3/4" | 3" | 5/16" | 1" | 1.43" | B | 266° | 0000000 | 00000 |
50 rpm @ 160 in.-oz. | 0.008 | 1.2 | 3 1/2" | 2 3/4" | 3" | 5/16" | 1" | 2.08" | B | 266° | 0000000 | 00000 |
24 Volts DC | ||||||||||||
1.2 rpm @ 800 in.-oz. | 0.001 | 0.1 | 3 1/4" | 2 3/4" | 3" | 5/16" | 1" | 1.43" | B | 266° | 0000000 | 00000 |
4 rpm @ 800 in.-oz. | 0.0033 | 0.4 | 3 1/4" | 2 3/4" | 3" | 5/16" | 1" | 1.43" | B | 266° | 0000000 | 00000 |
8 rpm @ 544 in.-oz. | 0.0043 | 0.5 | 3 1/2" | 2 3/4" | 3" | 5/16" | 1" | 1.43" | B | 266° | 0000000 | 00000 |
12 rpm @ 384 in.-oz. | 0.0045 | 0.4 | 3 1/2" | 2 3/4" | 3" | 5/16" | 1" | 1.43" | B | 266° | 0000000 | 00000 |
17 rpm @ 272 in.-oz. | 0.0045 | 0.5 | 3 1/2" | 2 3/4" | 3" | 5/16" | 1" | 1.43" | B | 266° | 0000000 | 00000 |
25 rpm @ 800 in.-oz. | 0.02 | 1.1 | 4" | 2 3/4" | 3" | 5/16" | 1" | 1.43" | B | 266° | 0000000 | 00000 |
47 rpm @ 448 in.-oz. | 0.02 | 1.1 | 4" | 2 3/4" | 3" | 5/16" | 1" | 2.08" | B | 266° | 0000000 | 00000 |
Compact Round-Face DC Gearmotors



Power small machinery in spaces where other gearmotors won’t fit. Gearmotors pair a motor with a speed reducer to lower speed while increasing torque.
To control motor speed, motor controls are also available. To convert AC power to DC power, see AC to DC transformers.
For technical drawings and 3-D models, click on a part number.
Overall | Shaft | Insulation | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Speed @ Continuous Operating Torque | Power, hp | Full Load Current, A | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max. Temp., ° F | Each | |
12 Volts DC | ||||||||||||
1 rpm @ 175 in.-oz. | 0.0001 | 0.2 | 4 1/4" | 2" | 2" | 1/4" | 3/4" | 1.33" | F | 311° | 0000000 | 0000000 |
2 rpm @ 175 in.-oz. | 0.0004 | 0.4 | 4 1/4" | 2" | 2" | 1/4" | 3/4" | 1.33" | F | 311° | 0000000 | 000000 |
7 rpm @ 140 in.-oz. | 0.001 | 0.7 | 4 1/4" | 2" | 2" | 1/4" | 3/4" | 1.33" | F | 311° | 0000000 | 000000 |
25 rpm @ 47 in.-oz. | 0.001 | 0.7 | 4 1/4" | 2" | 2" | 1/4" | 3/4" | 1.33" | F | 311° | 0000000 | 000000 |
83 rpm @ 16 in.-oz. | 0.0012 | 0.7 | 4 1/4" | 2" | 2" | 1/4" | 3/4" | 1.33" | F | 311° | 0000000 | 000000 |
19.1 Volts DC | ||||||||||||
21 rpm @ 100 in.-oz. | 0.0021 | 0.5 | 3 3/4" | 1 3/8" | 1 3/8" | 0.19" | 3/4" | 0.95" | F | 311° | 0000000 | 000000 |
65 rpm @ 46 in.-oz. | 0.0032 | 0.6 | 3 3/4" | 1 3/8" | 1 3/8" | 0.19" | 3/4" | 0.95" | F | 311° | 0000000 | 000000 |
202 rpm @ 16 in.-oz. | 0.0036 | 0.6 | 3 3/4" | 1 3/8" | 1 3/8" | 0.19" | 3/4" | 0.95" | F | 311° | 0000000 | 000000 |
625 rpm @ 6 in.-oz. | 0.004 | 0.6 | 3 3/4" | 1 3/8" | 1 3/8" | 0.19" | 3/4" | 0.95" | F | 311° | 0000000 | 000000 |
Extended-Life Compact Round-Face DC Gearmotors



Power small machinery in spaces where other gearmotors won’t fit. Gearmotors pair a motor with a speed reducer to lower speed while increasing torque. Wire for clockwise or counterclockwise rotation.
Use a motor speed control (not included) to adjust the motor speed.
To convert AC power to DC power, see AC to DC transformers.
Gearmotors have ball bearings that withstand heavier loads than gearmotors with sleeve bearings for a longer service life.
For technical drawings and 3-D models, click on a part number.
Overall | Shaft | Insulation | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Speed @ Continuous Operating Torque | Power, hp | Full Load Current, A | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max. Temp., ° F | Each | |
12 Volts DC | ||||||||||||
161 rpm @ 374 in.-oz. | 0.0714 | 6.4 | 6 1/4" | 2 1/4" | 2 3/4" | 1/4" | 3/4" | 1" | F | 311° | 0000000 | 0000000 |
536 rpm @ 124 in.-oz. | 0.0769 | 6.4 | 6 1/4" | 2 1/4" | 2 3/4" | 1/4" | 3/4" | 1" | F | 311° | 0000000 | 000000 |
24 Volts DC | ||||||||||||
161 rpm @ 374 in.-oz. | 0.0714 | 3.2 | 6 1/4" | 2 1/4" | 2 3/4" | 1/4" | 3/4" | 1" | F | 311° | 0000000 | 000000 |
536 rpm @ 124 in.-oz. | 0.0769 | 3.2 | 6 1/4" | 2 1/4" | 2 3/4" | 1/4" | 3/4" | 1" | F | 311° | 0000000 | 000000 |