Filter by
Pump Type
For Use With
Maximum Pressure
Power Source
Flow Rate
Priming Type
Pump Style
Maximum Feet of Head
Housing Material
Discharge Connection
Flow Adjustment Mechanism
Electrical Phase
Duty Cycle
Export Control Classification Number (ECCN)
DFARS Specialty Metals
High-Accuracy Metering Diaphragm Pumps for Chemicals
![]() |
These diaphragm pumps meter a consistent amount of liquid within ±2% of the maximum flow. Often used to pump water-treatment chemicals, cleaning fluids, and electropolishing solutions, they have an adjustment dial that alters flow rate in 2% increments of the maximum flow. Pumps are self-priming and create suction to draw liquid upward. They can run dry but are not for use with solids.
Pump Repair Kits—Repair kits include a pump head assembly, a diaphragm, valves, and seals.
Diaphragm Pumps | Pump Repair Kits | Replacement Drain Valves | Replacement Flow-Adjustment Valves | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube | Overall | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow Rate, gal/day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, ° F | Power, hp | Current, amp | ID | OD | Lg. | Wd. | Ht. | Features | Each | Each | Each | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
120V AC, Single Phase | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Plug In | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.03 to 3 | 300 | 1,000 | 35 to 150 | 11/64 | 1 | 1/4" | 3/8" | 10 7/8" | 5 1/2" | 10 3/8" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 00000000 | 0000000 | 00000000 | 0000000 | 00000000 | 000000 | 00000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.05 to 5 | 250 | 1,000 | 35 to 150 | 11/64 | 1 | 1/4" | 3/8" | 10 7/8" | 5 1/2" | 10 3/8" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 00000000 | 000000 | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.12 to 12 | 250 | 1,000 | 35 to 150 | 11/64 | 1 | 1/4" | 3/8" | 11 1/4" | 5 1/2" | 10 5/8" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 00000000 | 000000 | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.22 to 22 | 150 | 1,000 | 35 to 150 | 11/64 | 1 | 1/4" | 3/8" | 11 1/4" | 5 1/2" | 10 5/8" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 00000000 | 000000 | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.24 to 24 | 100 | 1,000 | 35 to 150 | 11/64 | 1 | 1/4" | 3/8" | 10 3/4" | 5 1/2" | 10 5/8" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 00000000 | 000000 | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.42 to 42 | 150 | 1,000 | 35 to 150 | 11/64 | 1 | 1/4" | 3/8" | 11 3/4" | 5 1/2" | 10 5/8" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 00000000 | 00000000 | 00000000 | 000000 | ——— | 0 | ——— | 0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.44 to 44 | 100 | 1,000 | 35 to 150 | 11/64 | 1 | 1/4" | 3/8" | 11 1/4" | 5 1/2" | 10 5/8" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 00000000 | 00000000 | 00000000 | 000000 | ——— | 0 | ——— | 0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.94 to 94 | 100 | 1,000 | 35 to 150 | 11/64 | 1 | 3/8" | 1/2" | 11 3/4" | 5 1/2" | 11" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.2 to 120 | 100 | 1,000 | 35 to 150 | 11/64 | 1 | 3/8" | 1/2" | 12" | 6 1/4" | 11 3/8" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.92 to 192 | 50 | 1,000 | 35 to 150 | 11/64 | 1 | 3/8" | 1/2" | 11 1/4" | 6 1/8" | 11 3/4" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2.4 to 240 | 35 | 1,000 | 35 to 150 | 11/64 | 1 | 3/8" | 1/2" | 12" | 6 1/8" | 11 3/4" | Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
6 to 600 | 30 | 1,000 | 35 to 150 | 11/64 | 1 | 1/2" | 3/4" | 11 3/8" | 6 1/8" | 11" | Backflow-Prevention Valve, Foot Valve/Strainer | 00000000 | 00000000 | 00000000 | 000000 | 00000000 | 000000 | ——— | 0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Remote-Adjust High-Accuracy Metering Diaphragm Pumps for Chemicals
![]() |
Automatically control output from a distance using 4-20 mA or external-pulse signals. View the flow rate on the backlit LCD. These diaphragm pumps meter a consistent amount of liquid within ±2% of the maximum flow. Often used to pump water-treatment chemicals, cleaning fluids, and electropolishing solutions, they have an adjustment dial that alters flow rate in 2% increments of the maximum flow. Pumps can run dry. Do not use with solids.
Pump Repair Kits—Repair kits include a pump head assembly, a diaphragm, valves, and seals.
Diaphragm Pumps | Pump Repair Kits | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube | Overall | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow Rate, gal/day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, ° F | Power, hp | Current, amp | External Signal, mA | Intake Tube Lg., ft. | Discharge Tube Lg., ft. | ID | OD | Lg. | Wd. | Ht. | Each | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
120V AC, Single Phase and With LCD Display | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Plug In | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.005 to 5 | 250 | 1,000 | 35 to 150 | 11/64 | 1 | 4 to 20 | 4 | 8 | 1/4" | 3/8" | 10 7/8" | 5 3/8" | 10 3/8" | 00000000 | 000000000 | 00000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.012 to 12 | 100 | 1,000 | 35 to 150 | 11/64 | 1 | 4 to 20 | 4 | 8 | 1/4" | 3/8" | 10 3/4" | 5 3/8" | 10 5/8" | 00000000 | 00000000 | 00000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.044 to 44 | 100 | 1,000 | 35 to 150 | 11/64 | 1 | 4 to 20 | 4 | 8 | 1/4" | 3/8" | 11 1/4" | 5 3/8" | 10 5/8" | 00000000 | 00000000 | 00000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.094 to 94 | 100 | 1,000 | 35 to 150 | 11/64 | 1 | 4 to 20 | 4 | 8 | 3/8" | 1/2" | 11 1/4" | 6 1/4" | 11 1/4" | 00000000 | 00000000 | 00000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.24 to 240 | 35 | 1,000 | 35 to 150 | 11/64 | 1 | 4 to 20 | 4 | 8 | 3/8" | 1/2" | 11 1/4" | 6 1/8" | 11 3/4" | 00000000 | 00000000 | 00000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Long-Life High-Accuracy Metering Diaphragm Pumps for Chemicals
![]() |
A 316 stainless steel housing provides corrosion resistance for a long life in harsh environments. These diaphragm pumps meter a consistent amount of liquid within ±2% of the maximum flow. Often used to pump water-treatment chemicals, they have an adjustment dial that alters flow rate in 2% increments of the maximum flow. Pumps are self-priming and create suction to draw liquid upward. They can run dry. Do not use with solids.
Pump Repair Kits—Repair kits include a pump head assembly, a diaphragm, valves, and seals.
Diaphragm Pumps | Pump Repair Kits | Replacement Drain Valves | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow Rate, gal/day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, ° F | Power, hp | Current, amp | Lg. | Wd. | Ht. | Features | Each | Each | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
120V AC, Single Phase | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Plug In | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.12 to 12 | 250 | 1,000 | 35 to 100 | 11/64 | 1 | 11 1/4" | 5 3/8" | 10 5/8" | Backflow-Prevention Valve, Strainer | 0000000 | 000000000 | 0000000 | 0000000 | 0000000 | 0000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.24 to 24 | 100 | 1,000 | 35 to 100 | 11/64 | 1 | 10 3/4" | 5 3/8" | 10 5/8" | Backflow-Prevention Valve, Strainer | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.94 to 94 | 100 | 1,000 | 35 to 100 | 11/64 | 1 | 11 1/4" | 6 1/4" | 9" | Backflow-Prevention Valve, Strainer | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Miniature Metering Diaphragm Pumps for Chemicals
![]() |
With a footprint that's only a few inches in any direction, these diaphragm pumps fit into compact systems to dispense small amounts of acids, cleaning fluids, and other chemicals. They're often used in sterilization, photochemical, and water treatment systems. Choose from pumps with either a 4-20mA or 1-5V DC input signal that controls the flow rate.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
External | Intake | Discharge | Overall | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gal/day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, ° F | Current, amp | Signal, mA | Voltage, V DC | Gender | For Tube ID | Gender | For Tube ID | For Tube OD | Lg. | Wd. | Ht. | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12V DC—With Thermal Overload Protection | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hardwire | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14 | 29 | 6 | 30 to 100 | 1.5 | — | 1 to 5 | Female | 1/8" | Female | 1/8" | 1/4" | 4" | 2 1/2" | 3 5/8" | 000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14 | 29 | 6 | 30 to 100 | 1.5 | 4 to 20 | — | Female | 1/8" | Female | 1/8" | 1/4" | 4" | 2 1/2" | 3 5/8" | 000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
24V DC—With Thermal Overload Protection | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hardwire | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14 | 29 | 6 | 30 to 100 | 1 | — | 1 to 5 | Female | 1/8" | Female | 1/8" | 1/4" | 4" | 2 1/2" | 3 5/8" | 000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14 | 29 | 6 | 30 to 100 | 1 | 4 to 20 | — | Female | 1/8" | Female | 1/8" | 1/4" | 4" | 2 1/2" | 3 5/8" | 000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
High-Pressure Metering Diaphragm Pumps for Chemicals with Locking Lever
![]() |
An adjustment dial with a locking lever allows for easy flow control. These metering diaphragm pumps can be used with pressures up to four times higher than standard chemical metering diaphragm pumps. They're often used for general purpose dispensing of chemicals such as ammonia and acid-washing solutions. The adjustment dial alters flow rate in 5% increments of the maximum flow. Pumps are self-priming and create suction to draw liquid upward. Do not run dry or use with solids.
Pump Repair Kits—Repair kits include a pump head assembly, valves, a diaphragm, and mounting hardware.
Diaphragm Pumps | Pump Repair Kits | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Intake | Discharge | Overall | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow Rate, gal/day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, ° F | Power, hp | Current, amp | Tube ID | Tube OD | Tube Lg., ft. | Tube ID | Tube OD | Tube Lg., ft. | Lg. | Wd. | Ht. | Each | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Plug In | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.3 to 3 | 100 | 300 | 35 to 125 | 1/60 | 1 | 5/16" | 7/16" | 4 | 3/8" | 1/2" | 8 | 8 7/8" | 7 1/4" | 6 3/4" | 0000000 | 0000000 | 0000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.7 to 7 | 100 | 300 | 35 to 125 | 1/60 | 1 | 5/16" | 7/16" | 4 | 3/8" | 1/2" | 8 | 8 7/8" | 7 1/4" | 6 3/4" | 0000000 | 000000 | 0000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.5 to 15 | 100 | 300 | 35 to 125 | 1/60 | 1 | 5/16" | 7/16" | 4 | 3/8" | 1/2" | 8 | 8 7/8" | 7 1/4" | 6 3/4" | 0000000 | 000000 | 0000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2.4 to 24 | 100 | 300 | 35 to 125 | 1/60 | 1 | 5/16" | 7/16" | 4 | 3/8" | 1/2" | 8 | 8 7/8" | 7 1/4" | 6 3/4" | 0000000 | 000000 | 0000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
3 to 30 | 100 | 300 | 35 to 125 | 1/60 | 1 | 5/16" | 7/16" | 4 | 3/8" | 1/2" | 8 | 8 7/8" | 7 1/4" | 6 3/4" | 0000000 | 000000 | 0000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10 to 100 | 60 | 300 | 35 to 125 | 1/60 | 1 | 5/16" | 7/16" | 4 | 3/8" | 1/2" | 8 | 8 7/8" | 7 1/4" | 6 3/4" | 0000000 | 000000 | 0000000 | 000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Metering Diaphragm Pumps for Coolants and Oils
![]() |
Use these diaphragm pumps for high-pressure output of antifreeze, hydraulic oil, and motor oil. They have an internal relief valve to prevent pressure buildup. The adjustment dial alters flow rate in 1% increments of the maximum flow. Pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. Do not run dry or use with solids.
Intake | Discharge | Overall | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gal/day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, ° F | Power, hp | Current, amp | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
120V AC, Single Phase—With Thermal Overload Protection and With Internal Relief Valve | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Plug In | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4.8 to 48 | 700 | 1,500 | 40 to 200 | 1/3 | 5.9 | 3/8 | NPT | Male | 3/8 | NPT | Male | 14 3/4" | 5 1/2" | 15 1/2" | 0000000 | 000000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
16.8 to 168 | 900 | 1,500 | 40 to 200 | 1/3 | 5.9 | 3/8 | NPT | Male | 3/8 | NPT | Male | 14 3/4" | 5 1/2" | 15 1/2" | 0000000 | 00000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
43.2 to 432 | 350 | 1,500 | 40 to 200 | 1/3 | 5.9 | 3/8 | NPT | Male | 3/8 | NPT | Male | 14 3/4" | 5 1/2" | 15 1/2" | 0000000 | 00000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||