    6 Products

    Differential Pressure Transmitters with Dial Indicator for Liquids

    Image of Product. Front orientation. Differential Pressure Transmitters. Differential Pressure Transmitters with Dial Indicator for Liquids.
    View readings at the source with the dial indicator or remotely using a receiver—these transmitters measure the difference in pressure between two inputs in liquid applications. The dial indicator operates independently of the transmitter and shows differential pressure in real time for troubleshooting. Also known as transducers, these transmitters convert pressure to an electrical signal that is interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. You’ll sometimes see them used to indicate a filter is clogged in a pump or cooling system. Rated NEMA 4X, these transmitters protect against dirt, washdown, and corrosion. They are also rated IP65 for protection from dust and rinsing. All are CSA certified, so they meet Canadian safety standards.
    For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    Mounting
    Holes
    Pressure Differential
    Max. Input
    Pressure, psi
    Input Voltage,
    V DC
    Pipe
    Size
    Mounting Hardware
    Included
    Dia.
    No.
    of
    Ht.
    Wd.
    Enclosure
    Rating
    Hazardous Location Rating
    For Use With
    Accuracy
    Pipe
    Connection
    Housing
    Material
    Temp. Range,
    ° F
    Each
    4 to 20 mA, 0 to 5V DC Output Signal—Screw Terminals
    0 in. H₂O to 25 in. H₂O1,5009 to 351/4
    No3/16"22"4 7/16"IP65, NEMA 4X
    NEC Class I Division 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups F, G
    Diesel Fuel, Gasoline, Hydraulic Fluid, Water±2%NPT FemaleBrass-20 to 20000000000000000
    0 psi to 1 psi1,5009 to 351/4
    No3/16"22"4 7/16"IP65, NEMA 4X
    NEC Class I Division 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups F, G
    Diesel Fuel, Gasoline, Hydraulic Fluid, Water±2%NPT FemaleBrass-20 to 2000000000000000
    0 psi to 5 psi1,5009 to 351/4
    No3/16"22"4 7/16"IP65, NEMA 4X
    NEC Class I Division 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups F, G
    Diesel Fuel, Gasoline, Hydraulic Fluid, Water±2%NPT FemaleBrass-20 to 2000000000000000
    0 psi to 15 psi5,0009 to 351/4
    No3/16"22 5/8"2 15/16"IP65, NEMA 4X
    NEC Class I Division 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups F, G
    Diesel Fuel, Gasoline, Hydraulic Fluid, Water±2%NPT FemaleBrass-20 to 2000000000000000
    0 psi to 30 psi5,0009 to 351/4
    No3/16"22 5/8"2 15/16"IP65, NEMA 4X
    NEC Class I Division 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups F, G
    Diesel Fuel, Gasoline, Hydraulic Fluid, Water±2%NPT FemaleBrass-20 to 2000000000000000
    0 psi to 50 psi5,0009 to 351/4
    No3/16"22 5/8"2 15/16"IP65, NEMA 4X
    NEC Class I Division 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups F, G
    Diesel Fuel, Gasoline, Hydraulic Fluid, Water±2%NPT FemaleBrass-20 to 2000000000000000
     
    back to top