McMaster-Carr logo
    Filter by
    Number of Digits
    Counting Direction
    Mounting Location
    Wire Connection
    Batteries Included
    Electrical Connection Type
    DFARS Specialty Metals
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    49 Products

    Large-Display Combination Switch-Contact/Electrically Actuated Counters

    Image of Product. Front orientation. Counters. Large-Display Combination Switch-Contact/Electrically Actuated Counters .
    The digits displayed on these counters are visible up to 100 ft. away and the display can be adjusted to suit lighting conditions. You can set counters up to count with or without voltage inputs based on the switch, sensor, or encoder you have. Counters can be wired for remote reset. They are protected against dust and washdowns and can be used outdoors (rated NEMA 4X). Programming backup maintains settings if power is lost.
    Overall
    Mounting
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts per Min.
    (Input Method)
    Digit
    Ht.
    Ht.
    Wd.
    Dp.
    Input Voltage
    Operating Voltage
    Features
    Fasteners
    Included
    Screw
    Size
    Enclosure
    Rating
    Certification
    Housing
    Material
    Each
    Screw On
     
    Screw Terminals
    YesDown, Up41,500,000 (Voltage),
    3,000 (Switch Contact)
    2 1/4"4"12"2.25"2.75V DC to 28V DC21.6V DC to 250V DC
    50V AC to 250V AC
    Programming Backup, Three-prong plug with 6' cord for operating displayNoNo. 10
    NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    Aluminum
    16635T410000000
    YesDown, Up41,500,000 (Voltage),
    3,000 (Switch Contact)
    4"7.875"20"2.25"2.75V DC to 28V DC21.6V DC to 250V DC
    50V AC to 250V AC
    Programming Backup, Three-prong plug with 6' cord for operating displayNoNo. 10
    NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    Aluminum
    16635T42000000
    YesDown, Up61,500,000 (Voltage),
    3,000 (Switch Contact)
    2 1/4"4"16"2.25"2.75V DC to 28V DC21.6V DC to 250V DC
    50V AC to 250V AC
    Programming Backup, Three-prong plug with 6' cord for operating displayNoNo. 10
    NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    Aluminum
    16635T43000000
    YesDown, Up61,500,000 (Voltage),
    3,000 (Switch Contact)
    4"7.875"26"2.25"2.75V DC to 28V DC21.6V DC to 250V DC
    50V AC to 250V AC
    Programming Backup, Three-prong plug with 6' cord for operating displayNoNo. 10
    NEMA 4X
    UL Listed, C-UL Listed, CE Marked
    Aluminum
    16635T4400000000
     

    Combination Switch-Contact/Electrically Actuated Counters

    Image of Product. Front orientation. Counters. Combination Switch-Contact/Electrically Actuated Counters , Screw On, Style A.
    Image of Product. Front orientation. Counters. Combination Switch-Contact/Electrically Actuated Counters , Screw On, Style B.

    Screw On

    Style A

    Screw On

    Style B

    You can set these counters up to count with or without voltage inputs based on the switch, sensor, or encoder you have. Count backup maintains the count if power is lost.
    Password Lockout—Password lockout prevents tampering and accidental loss of data.
    Programming Backup—Counters with programming backup maintain settings if power is lost.
    Scaling Function—A scaling function lets you adjust the unit of measure to suit your application.
    For Panel
    Cutout
    Style
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts per Min.
    (Input Method)
    DIN
    Size
    Ht.
    Wd.
    Overall
    Dp.
    Input Voltage
    Operating
    Voltage
    Includes
    Features
    Enclosure
    Rating
    Certification
    Each
    Screw On
     
    Screw Terminals
    AYesUp6600,000 (Voltage),
    600,000 (Switch Contact)
    1/320.87"1.77"2.4"4V DC to 30V DC (High Level),
    0V DC to 1V DC (Low Level)
    10V DC to 30V DCCount BackupNEMA 4X, IP65
    CE Marked
    1745T110000000
    AYesUp and Down6600,000 (Voltage),
    600,000 (Switch Contact)
    1/320.87"1.77"2.4"4V DC to 30V DC (High Level),
    0V DC to 1V DC (Low Level)
    10V DC to 30V DCCount Backup, Scaling FunctionNEMA 4X, IP65
    CE Marked
    1745T21000000
    BYesDown, Up61,200,000 (Voltage),
    1,200,000 (Switch Contact)
    1/81.77"3.62"3.3"0V DC to 12V DC120V ACCount Backup, Password Lockout, Programming Backup, Scaling FunctionIP50
    UL Listed, C-UL Listed
    7959T33000000
    BYesDown, Up61,200,000 (Voltage),
    1,200,000 (Switch Contact)
    1/81.77"3.62"3.3"0V DC to 12V DC120V AC12V DC Power Source for External SensorCount Backup, Password Lockout, Programming Backup, Scaling FunctionIP50
    UL Listed, C-UL Listed
    7959T41000000
     

    Large-Display Combination Switch-Contact/Electrically Actuated Counters with Output Relay

    Image of Product. Front orientation. Counters. Large-Display Combination Switch-Contact/Electrically Actuated Counters with Output Relay .
    The digits displayed on these counters are visible up to 100 ft. away and the display can be adjusted to suit lighting conditions. You can set counters up to count with or without voltage inputs based on the switch, sensor, or encoder you have. They can be wired for remote reset. An output relay sends a signal to another device when a set point is reached. The signal can start/stop a process or trigger an alarm. Counters are protected from dust and washdowns and can be used outdoors (rated NEMA 4X). Programming backup maintains settings if power is lost.
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    No. of Set
    Points
    Max. Counts per Min.
    (Input Method)
    Digit
    Ht.
    Ht.
    Wd.
    Dp.
    Input Voltage,
    V DC
    Operating Voltage
    Output Relay Current @ Input Voltage
    Mounting
    Screw Size
    Enclosure
    Rating
    Each
    Screw On
     
    Screw Terminals
    YesDown, Up611,500,000 (Voltage),
    3,000 (Switch Contact)
    2 1/4"4"16"2.25"2.75 to 2821.6V DC to 250V DC
    50V AC to 250V AC
    5 amp @ 120V AC
    5 amp @ 240V AC
    5 amp @ 28V DC
    No. 10
    NEMA 4X
    16635T810000000
    YesDown, Up611,500,000 (Voltage),
    3,000 (Switch Contact)
    4"7.875"26"2.25"2.75 to 2821.6V DC to 250V DC
    50V AC to 250V AC
    5 amp @ 120V AC
    5 amp @ 240V AC
    5 amp @ 28V DC
    No. 10
    NEMA 4X
    16635T8300000000
     

    DIN-Panel-Mount Electrically Actuated Counters

    Image of Product. Front orientation. Counters. DIN-Panel-Mount Electrically Actuated Counters , Press On.
    Image of Product. Front orientation. Counters. DIN-Panel-Mount Electrically Actuated Counters , Screw On.

    Press On

    Screw On

    For quick installation, these counters fit standard DIN panel cutouts. Wire them up to an electrical pulse-emitting switch, sensor, or encoder for use on machine tools, packaging machinery, or other equipment.
    Press On—Press-on counters have a front panel that is rated NEMA 4 and IP66 for protection against dust and washdowns and outdoor use. The screw terminals are rated IP20.
    Screw On—Screw-on counters are rated NEMA 4X, NEMA 12, and IP65 for protection against dust, water, and splashing oil and coolant.
    Backlit Display—Counters with backlit display have good visibility in low-light conditions.
    For Panel
    Cutout
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts
    per min.
    DIN
    Size
    Ht.
    Wd.
    Overall
    Dp.
    Input Voltage
    Features
    Enclosure Rating
    Each
    Press On
     
    Screw Terminals
    YesUp81,2001/320.87"1.77"2"24V AC to 240V AC/24V DC to 240V DC (High Level)
    0V AC to 2V AC/0V DC to 2V DC (Low Level)
    Battery-Powered DisplayNEMA 4, IP20, IP66
    1737T250000000
    YesUp860,0001/320.87"1.77"2"4.5V DC to 30V DC (High Level)
    0V DC to 2V DC (Low Level)
    Battery-Powered DisplayNEMA 4, IP20, IP66
    1737T23000000
     
    Screw On
     
    Screw Terminals
    YesDown, Up86001/320.87"1.77"2.1"10V AC to 240V AC (High Level)
    10V DC to 110V DC (Low Level)
    Backlit Display, Battery-Powered DisplayNEMA 4X, NEMA 12, IP65
    1737T5200000
    YesDown, Up8600,0001/320.87"1.77"2.1"18V DCBacklit Display, Battery-Powered DisplayNEMA 4X, NEMA 12, IP65
    1737T4100000
     

    Counters with Proximity Sensor

    Image of Product. Front orientation. Counters. Counters with Proximity Sensor .
    Count metallic objects as they touch or pass within 0.059" of this counter's built-in sensor. It has an output relay to send a signal to another device when a set point is reached. The signal can start/stop a process or trigger an alarm. A scaling function lets you adjust the unit of measure to suit your application. Counter and enclosure are protected from dust and washdowns and can be used outdoors (rated NEMA 4X). Drill through the back of the enclosure to mount to a wall or work surface.
    Sensor
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    No. of Set
    Points
    Max. Counts
    per min.
    Max. Sensing
    Distance
    Lg.
    Dia.
    Cord Lg.,
    ft.
    Ht.
    Wd.
    Dp.
    Operating
    Voltage, V AC
    Output Relay Current @ Input Voltage
    Features
    Enclosure
    Rating
    Certification
    Housing
    Material
    Each
    Screw On
    YesDown, Up62300,0000.059"3 1/2"3/4"107.5"7.5"5.1"85 to 2505 amp @ 120V AC
    5 amp @ 240V AC
    5 amp @ 28V DC
    Scaling FunctionNEMA 4X
    UL Listed, C-UL Listed
    Plastic18875T71000000000
     

    Switch-Contact-Actuated Counters

    Image of Product. Front orientation. Counters. Switch-Contact-Actuated Counters , Press On, Manual Reset Button.

    Press On,

    Manual Reset

    Button

    Image of Product. Front orientation. Counters. Switch-Contact-Actuated Counters , Clip On, Manual Reset Button.

    Clip On,

    Manual Reset

    Button

    Image of Product. Press On. Front orientation. 0.5" Overall Depth. Switch-Contact-Actuated Counters .

    Press On

    No need for a separate power source—these counters are powered by internal batteries that last more than seven years. Often used in areas where power isn’t easy to access, they work well inside machinery or remote monitoring systems. Wire them to a relay, sensor, switch, or other trigger device on the machine performing repeated tasks. The counter receives a signal from the trigger device to track how many times the task has occurred and shows that number on the display.
    All can be connected to a separate input, button, or switch to reset the counter to zero directly or at a distance.
    Clip On—Clip on counters can be mounted with a gasket (sold separately) to meet NEMA 4/4X, NEMA 12, and IP66 ratings for protection against dust, water, and splashing oil and coolant.
    Indicator Icons—Counters with indicator icons can be programmed to flash a symbol of your choosing after a set number of tasks have been completed. Similar to the lights on your car’s dashboard, there are icons for your oil, oil filter, service, and more.
    Manual Reset Button—Those with a manual reset button can be set to zero with a simple push.
    NEMA 4 Enclosure Rating—NEMA 4 rated counters are protected from dust and washdowns. They’re also safe to use outdoors.
    Counters
    Gaskets
    For Panel
    Cutout
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts
    per min.
    DIN
    Size
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Batteries
    Replaceable
    Features
    Enclosure
    Rating
    Certification
    Housing
    Material
    Each
    Each
    Press On
     
    Screw Terminals
    YesUp860,0001/320.87"1.77"1"1.9"2"YesBattery-Powered Display, Manual Reset Button, Remote ResetNEMA 4
    UL Recognized Component, CE Marked
    Plastic1737T220000000———0
     
    Tabs
    YesUp61,0800.87"1.16"0.9"1.2"0.5"YesBattery-Powered Display, Remote ResetCE Marked
    Plastic7235N1200000———0
     
    Clip On
     
    Wire Leads
    YesUp830,0001/320.87"1.78"1.1"2"1.5"NoBattery-Powered Display, Indicator Icons, Manual Reset Button, Remote ResetUL Recognized Component, C-UL Recognized Component, CE Marked
    Plastic7235N11000008672T4600000
     

    Pen Counters

    Image of ProductInUse. Pen Counter with Hand-Tally Adapter Installed. Front orientation. Counters. Pen Counters .
    Image of Product. Pen Counter Shown on Weighted Stand. Front orientation. Counters. Pen Counters .
    Image of Product. Front orientation. Counters. Pen Counters .

    Pen Counter with

    Hand-Tally Adapter

    Installed

    Pen

    Counter

    Shown on

    Weighted

    Stand

    Tally each time you make a pen mark to keep an accurate count. These counters have a black marker that you can replace with a standard permanent marker. Swap the pen with the hand-tally adapter to use these as standard hand-held counters.
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. No.
    of Events
    Indicator
    Type
    Ht.
    Wd.
    Dp.
    Includes
    Features
    Each
    Plastic Housing
    YesUp and Down332Light, Sound7"1.2"1.1"Hand-Tally Adapter, Marker, Weighted StandLithium-Ion Battery-Powered Display7241N110000000
     

    Panel-Mount Electrically Actuated Counters

    Image of Product. Front orientation. Counters. Panel-Mount Electrically Actuated Counters , Screw On, Style E.
    Image of Product. Front orientation. Counters. Panel-Mount Electrically Actuated Counters , Screw On, Style F.
    Image of Product. Front orientation. Counters. Panel-Mount Electrically Actuated Counters , Screw On, Style G.
    Image of Product. Front orientation. Counters. Panel-Mount Electrically Actuated Counters , Clip On, Style J.

    Screw On

    Style E

    Screw On

    Style F

    Screw On

    Style G

    Clip On

    Style J

    Wire these counters up to an electrical pulse-emitting switch, sensor, or encoder for use on machine tools, packaging machinery, or other equipment.
    Styles G and J—Styles G, J, and K can be mounted with a gasket (sold separately) to keep out dust, water from washdowns, and splashing oil and coolant, making them NEMA and IP rated.
    Counters
    Counter Gaskets
    For Panel
    Cutout
    Overall
    Mounting
    Style
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts
    per min.
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Dia.
    Input Voltage
    Features
    Fasteners
    Included
    Screw
    Size
    Certification
    Housing
    Material
    Each
    For Enclosure Rating
    Each
    Screw On
     
    Wire Leads
    EYesUp62,4001.8"3"1.9"4.5"2.9"6V AC to 240V AC, 6V DC to 240V DCBattery-Powered DisplayNoNo. 8
    Zinc Alloy1874T820000000———0
    FYesUp62,4001.5"4.8"2.2"5.5"2.9"6V AC to 240V AC, 6V DC to 240V DCBattery-Powered DisplayNoNo. 8
    Zinc Alloy1874T83000000———0
     
    Spade Terminals
    GYesUp82,4000.9"1.4"1.1"2.1"0.8"20V AC to 300V AC, 10V DC to 300V DCBattery-Powered DisplayYesNo. 5
    C-UL Recognized Component
    Plastic1874T9100000IP66, NEMA 12, NEMA 4X
    1806T2600000
     
    Clip On
     
    Spade Terminals
    JYesUp82,4001"1.5"1.2"2.2"20V AC to 300V AC, 10V DC to 300V DCBattery-Powered DisplayC-UL Recognized Component
    Plastic1874T9300000IP66, NEMA 12, NEMA 4X
    1806T250000
     

    Surface-Mount Electrically Actuated Counters

    Image of Product. Front orientation. Counters. Surface-Mount Electrically Actuated Counters , Screw On, Style F.

    Screw On

    Style F

    Wire these counters up to an electrical pulse-emitting switch, sensor, or encoder for use on machine tools, packaging machinery, or other equipment.
    Overall
    Mounting
    Style
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts
    per min.
    Ht.
    Wd.
    Dp.
    Input Voltage
    Features
    Fasteners
    Included
    Screw
    Size
    Housing
    Material
    Each
    Screw On
     
    Wire Leads
    FYesUp62,4001.8"3.9"3"6V AC to 240V AC, 6V DC to 240V DCBattery-Powered DisplayNoNo. 5
    Zinc Alloy1874T810000000
     

    Large-Display Digital Timers

    Image of System. Front orientation. Contains Annotated. Timers. Large-Display Digital Timers.
    Read elapsed or remaining time from up to 150 ft. away—roughly half the length of a football field. These timers count up and down from zero. When counting down past zero, they flash and display a negative symbol before the time. To start, pause, and reset these timers, they require a controller (sold separately).
    Controllers—The controller comes with a 20 ft. RJ45 cable to connect it to the timer.
    Splitters—Add a splitter to connect two timers to the same controller.
    Timers
    Controllers
    Splitters
    Case
    Timing Functions
    Max. No.
    of Events
    Max. Timer
    Duration, hr.
    Max. Alarm
    Duration
    Timer Resolution,
    sec.
    Ht.
    Wd.
    Dp.
    Material
    Color
    Electrical
    Connection Type
    Includes
    Features
    Each
    Each
    Each
    Count Up
    Count Down
    Pause
    1100Continuous16 1/4"15 1/2"1 1/2"PlasticBlackHardwireMounting BracketAlarm7384N1200000007384N1100000007384N13000000
     

    Combination Switch-Contact/Electrically Actuated Counters with Output Relay

    Image of Product. Front orientation. Counters. Combination Switch-Contact/Electrically Actuated Counters with Output Relay , Style A.
    Image of Product. Front orientation. Counters. Combination Switch-Contact/Electrically Actuated Counters with Output Relay , Style B.

    Style A

    Style B

    You can set these counters up to count with or without voltage inputs based on the switch, sensor, or encoder you have. An output relay sends a signal to another device when the counter reaches a set point. The signal can start/stop a process or trigger an alarm. If power is lost, count backup maintains the count and programming backup maintains settings.
    Password Lockout—Password lockout prevents tampering and accidental loss of data.
    Scaling Function—A scaling function lets you adjust the unit of measure to suit your application.
    NEMA 4X Enclosure Rating—Counter rated NEMA 4X is protected from dust and washdowns and can be used outdoors.
    Resettable
    Counting
    Direction
    No. of
    Digits
    No. of Set
    Points
    Max. Counts per Min.
    (Input Method)
    Overall
    Dp.
    Input Voltage,
    V DC
    Operating
    Voltage
    Output Relay Current
    @ Input Voltage
    Includes
    Features
    Enclosure
    Rating
    Certification
    Each
    Style A—For 1/8 DIN Panel Cutout (1.77" Ht. × 3.62" Wd.)
     
    Screw On
    YesDown, Up621,200,000 (Voltage),
    1,200,000 (Switch Contact)
    3.3"0 to 12120V AC5 amp @ 250V ACCount Backup, Password Lockout, Programming Backup, Scaling FunctionIP50
    UL Listed, C-UL Listed
    7959T420000000
    YesDown, Up621,200,000 (Voltage),
    1,200,000 (Switch Contact)
    3.3"0 to 12120V AC5 amp @ 250V AC12V DC Power Source for External SensorCount Backup, Password Lockout, Programming Backup, Scaling FunctionIP50
    UL Listed, C-UL Listed
    7959T43000000
    YesUp and Down621,200,000 (Voltage),
    1,200,000 (Switch Contact)
    3.3"0 to 12120V AC5 amp @ 250V AC12V DC Power Source for External SensorCount Backup, Password Lockout, Programming Backup, Scaling FunctionIP50
    UL Listed, C-UL Listed
    7959T39000000
     
    Style B—For 1/16 DIN Panel Cutout (1.77" Ht. × 1.77" Wd.)
     
    Screw On
    YesUp and Down62690,000 (Voltage),
    690,000 (Switch Contact)
    4.2"0 to 3011V DC to 14V DC
    85V AC to 250V AC
    5 amp @ 250V ACGasketCount Backup, Programming Backup, Scaling FunctionNEMA 4X, IP65
    UL Recognized Component, C-UL Recognized Component, CE Marked
    1774T45000000
     

    Counters/Ratemeters

    Image of Product. Press On. Front orientation. Counters. Counters/Ratemeters , Press On.
    Image of Product. Front orientation. Counters. Counters/Ratemeters , Clip On.

    Press On

    Clip On

    Wire these counters/ratemeters to an electrical pulse-emitting switch, sensor, or encoder to count input while tracking rates in units such as gallons per minute. A scaling function lets you adjust the unit of measure to suit your application. Use the toggle button to switch between the count and the rate. IP or NEMA rated, they protect against dust and washdowns and can be used outdoors.
    For Panel
    Cutout
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts per Min. (Input Method)
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Input Voltage
    Features
    Enclosure
    Rating
    Certification
    Each
    Press On
     
    Screw Terminals
    YesUp63,600,000 (Voltage), 1,800 (Switch Contact)0.874"1.772"0.945"1.89"2.729"4V DC to 30V DC (High Level), 0V DC to 2V DC (Low Level)Scaling Function, Toggle ButtonIP65
    UL Recognized Component, C-UL Recognized Component, CE Marked
    4126K380000000
     
    Clip On
     
    Screw Terminals
    YesUp and Down8960,000 (Voltage), 3,000 (Switch Contact)1.29"2.62"1.54"2.95"1.86"1.25V DC to 28V DC (High Level), 2.75V DC to 28V DC (Low Level)Quadrature Sensing, Scaling Function, Toggle ButtonNEMA 4X, IP65
    UL Listed, C-UL Listed, CE Marked
    4126K41000000
     

    Large-Display Counters/Ratemeters with Output Relay

    Image of Product. Front orientation. Counters. Large-Display Counters/Ratemeters with Output Relay .
    At a glance, quickly read counts and rates in units, such as gallons per minute. The display on these counters/ratemeters is visible up to 130 ft. away—almost half of a football field—and gets brighter or dimmer based on your lighting. They have an output relay, so you can program them to start or stop a process or trigger an alarm when they reach their setpoint. These counters/ratemeters count using either a voltage or switch contact input, so they work with most sensors, encoders, and switches. You can wire them to reset remotely.
    Press the button on the display to toggle between the count and rate. You can also program these counters/ratemeters to toggle automatically between the count and rate every few seconds. With the scaling function, you can change the unit of measure. Hardwire them to power the display. They have a programming backup, so if you lose power you won't lose your settings.
    IP65 and NEMA 4X rated, these counters/ratemeters stand up to dust, rain, snow, and washdowns.
    Overall
    Mounting
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts per Min. (Input Method)
    Ht.
    Wd.
    Dp.
    Input
    Voltage
    Output Relay Current
    @ Input Voltage
    Features
    Fasteners
    Included
    Screw
    Size
    Enclosure
    Rating
    Certification
    Housing
    Material
    Each
    Screw On
     
    Screw Terminals
    YesUp and Down61,500,000 (Voltage), 1,500,000 (Switch Contact)4"16"2.25"28V DC5 amp @ 120V AC
    5 amp @ 28V DC
    Programming Backup, Scaling Function, Toggle ButtonNoNo. 10
    NEMA 4X, IP65
    UL Listed, C-UL Listed, CE Marked
    Aluminum
    7381N12000000000
    YesUp and Down61,500,000 (Voltage), 1,500,000 (Switch Contact)7.875"26"2.25"28V DC5 amp @ 120V AC
    5 amp @ 28V DC
    Programming Backup, Scaling Function, Toggle ButtonNoNo. 10
    NEMA 4X, IP65
    UL Listed, C-UL Listed, CE Marked
    Aluminum
    7381N1100000000
     

    Handheld Push-Button Counters

    Image of Product. Front orientation. Counters. Handheld Push-Button Counters , Style B.
    Image of Product. Front orientation. Counters. Handheld Push-Button Counters , Style C.
    Image of Product. Front orientation. Counters. Handheld Push-Button Counters , Style D.

    Style B

    Style C

    Style D

    Plastic Housing—Plastic counters weigh less than steel counters and withstand corrosion better.
    Overall
    Style
    Resettable
    Counting
    Direction
    No. of
    Digits
    Dia.
    Ht.
    Wd.
    Dp.
    Includes
    Each
    Plastic Housing
    BYesUp42.4"1.4"0.6"1960T56000000
    CYesUp and Down42.4"1.4"0.6"1960T5700000
    DYesUp51.9"0.5"Wrist Strap1960T7100000
     

    DIN-Panel-Mount Counters/Ratemeters

    Image of Product. Front orientation. Counters. DIN-Panel-Mount Counters/Ratemeters .
    For quick installation, these counters/ratemeters fit a standard 1/8 DIN panel cutout. Wire them up to an electrical pulse-emitting switch, sensor, or encoder to count input while tracking rates in units such as gallons per minute. The scaling function lets you adjust the unit of measure to suit your application. Counters are protected from dust and washdowns and can be used outdoors (rated NEMA 4X).
    For Panel
    Cutout
    Overall
    Resettable
    Counting
    Direction
    No. of
    Digits
    Max. Counts per Min. (Input Method)
    DIN
    Size
    Ht.
    Wd.
    Ht.
    Wd.
    Dp.
    Input Voltage,
    V DC
    Operating
    Voltage
    Includes
    Enclosure
    Rating
    Certification
    Each
    Screw On
     
    Screw Terminals
    YesUp and Down62,000,000 (Voltage), 2,000,000 (Switch Contact)1/81.77"3.62"2"3.8"4.2"0 to 3085V AC to 250V AC12V DC Power Source for External SensorNEMA 4X, IP65
    UL Listed, C-UL Listed, CE Marked
    2620T510000000
    YesUp and Down62,000,000 (Voltage), 2,000,000 (Switch Contact)1/81.77"3.62"2"3.8"4.2"0 to 3011V DC to 36V DC12V DC Power Source for External SensorNEMA 4X, IP65
    UL Listed, C-UL Listed, CE Marked
    2620T52000000
     
    Output Relays

    Digital Safety Scoreboard Signs

    Inspire safe work with a visual record—these scoreboards keep an automatic count of accident-free days. Make changes with the included remote control.
    On the Job Safety Begins Here—We Have Worked__Days Without an OSHA Recordable Injury Accidents Are Avoidable (English)
    Image of Product. Front orientation. Signs. Digital Safety Scoreboard Signs.
    Electrical
    Connection
    Mounting
    Max. Day
    Count
    Ht.
    Wd.
    Thk.
    Voltage,
    V AC
    No. of
    Blades
    Electrical
    Connection
    Cord Lg.,
    ft.
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Includes
    Color
    Message
    Color
    Message
    Contains
    Each
    Mounting Hole—Aluminum
    9,99928"20"1"1202Straight Blade8No21/4"Remote ControlGreen/WhiteBlack/WhiteText and Symbols2077N110000000
     

    DIN Panel Adapters

    Image of Product. Front orientation. Exploded view. DIN Panel Adapters.
    Use these adapters when the size of a meter face is too small for the DIN cutout in a panel or enclosure. They consist of two plates and a gasket. They offer protection from dust and washdowns and can be used outdoors (rated NEMA 4).
    For Panel
    Cutout
    For
    Counter
    Material
    For DIN Panel
    Cutout Size
    Ht.
    Wd.
    Ht.
    Wd.
    Plate
    Gasket
    Enclosure
    Rating
    Each
    1/4-1/83.62"3.62"1.77"3.62"SteelRubber
    NEMA 4
    1647T12000000
    1/4-1/163.62"3.62"1.77"1.77"SteelRubber
    NEMA 4
    1647T1300000
    1/8-1/161.77"3.62"1.77"1.77"SteelRubber
    NEMA 4
    1647T11000000
    back to top