Time and Day Activated Switches
Program these switches to turn a device on and off at a set time and day. They have a three-prong outlet to plug devices directly into the switch. Use with lamps and other small electrical loads. All have an override to bypass the programmed on/off settings.
Seven-day switches can perform a different program each day of the week.
Switches with astronomical timing can be set to turn lights on and off based on sunrise and sunset.
Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Switching Current @ Voltage | No. of Outlets | Features | Ht. | Wd. | Dp. | Plug Type | Each | |
7-Day Timing Cycle | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
14 per Day | 1 min. | Push Button | 15 A @ 120 V AC | 2 | Astronomical Timing, Random On/Off Option | 3" | 3 1/2" | 3 1/2" | Three Prong | 0000000 | 000000 |
Outdoor Time and Day Activated Switches
Designed to work with landscape lighting and filter pumps, these switches turn equipment on and off at a set time and day. They control two devices at once, and have three-prong outlets to plug devices directly into the switch. All have an override to bypass the programmed on/off settings.
24-hour switches repeat the same program daily. Position trippers around the clock dial to set on and off times.
Seven-day switches can perform a different program each day of the week. They have astronomical timing that can be set to turn lights on and off based on sunrise and sunset.
Switches with light sensor control allow one device to be controlled by the presence or absence of light.
NEMA 3R rated switches are protected against falling liquids and light splashing.
Mounting | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Tripper Type | No. of Trippers | Switching Current @ Voltage | No. of Outlets | Features | Ht. | Wd. | Dp. | Plug Type | Cord Lg., ft. | Fasteners Included | No. of Holes | Hole Dia. | Min. Ht., ft. | Each | |
24-Hour Timing Cycle—NEMA 3R | ||||||||||||||||||
12 per Day | 30 min. | Trippers | Removable | 4 | 15 A @ 120 V AC | 2 | Light Sensor Control | 9 3/8" | 5 1/2" | 3 3/8" | Three Prong | 2 | No | 4 | 1/4" | __ | 0000000 | 0000000 |
7-Day Timing Cycle | ||||||||||||||||||
7 per Day | 1 min. | Push Button | __ | __ | 15 A @ 120 V AC | 2 | Astronomical Timing, Random On/Off Option | 5 1/8" | 5 1/4" | 1 7/8" | Three Prong | 2 | No | 2 | 0.31" | 4.5 | 0000000 | 00000 |
Additional Trippers (Pkg. of 2 Pairs) | 0000000 | Pkg. | 00000 |
Outlet-Box-Mount Time and Day Activated Switches
Switches fit single device (1 gang) outlet boxes. Program them to turn a device on and off at a set time and day. They’re often used with lamps and other small electrical loads.
Seven-day switches can perform a different program each day of the week. Use the astronomical timing to turn lights on and off based on sunrise and sunset; this option can be used independently or in combination with timed programming.
No. of Circuits Controlled | Switching Current @ Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Features | For Outlet Box Type | Wire Connection Type | Wire Lead Lg. | Each | |
7-Day Timing Cycle | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | 15 A @ 120 V AC | 40 per Week | 1 min. | Push Button | Astronomical Timing, Battery Backup, LCD Display | 1 Device (1 Gang) | Wire Leads | 6" | 0000000 | 000000 |
Outdoor Set-to-the-Minute High-Current Time and Day Activated Switches
Rated NEMA 3R, these rain-tight switches protect against falling liquids and light splashing. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. They control equipment with high currents, such as landscape lighting, pumps, and heaters. A backup battery maintains the program during a power outage.
24-hour switches repeat the same program daily.
Seven-day switches can perform a different program each day of the week.
Seven-day/365-day switches can perform a different program each day of the week or year, and compensate for leap year and daylight savings time. Override regular programming for up to 99 holidays for any length of time. They can also be used to activate equipment such as bells and signals for just a few seconds.
Switches with astronomical timing can be set to turn lights on and off based on sunrise and sunset.
Switches with a day skipper can be programmed to skip operation for one to six days.
Mounting | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Housing Material | Industry Designation | Ht. | Wd. | Dp. | Fasteners Included | Hole Dia. | Wire Connection Type | Each | |
24-Hour Timing Cycle | |||||||||||||||
With Battery Backup, Lockout | |||||||||||||||
1 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 20 per Day | 1 min. | Push Button | Polycarbonate Plastic | SPST | 8 3/8" | 5" | 3 1/8" | No | 0.26" | Screw Terminals | 0000000 | 0000000 |
2 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 20 per Day | 1 min. | Push Button | Polycarbonate Plastic | DPST | 8 3/8" | 5" | 3 1/8" | No | 0.26" | Screw Terminals | 0000000 | 000000 |
7-Day Timing Cycle | |||||||||||||||
With Battery Backup, Lockout, Day Skipper | |||||||||||||||
2 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 20 per Day | 1 min. | Push Button | Polycarbonate Plastic | DPST | 8 3/8" | 5" | 3 1/8" | No | 0.26" | Screw Terminals | 0000000 | 000000 |
With Battery Backup, Lockout, Day Skipper, Astronomical Timing | |||||||||||||||
1 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 20 per Day | 1 min. | Push Button | Polycarbonate Plastic | SPDT | 8 3/8" | 5" | 3 1/8" | No | 0.26" | Screw Terminals | 0000000 | 000000 |
7-Day/365-Day Timing Cycle | |||||||||||||||
With Battery Backup, Lockout, Astronomical Timing | |||||||||||||||
1 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 4,000 per Year | 1 min. | Push Button | Steel | SPDT | 8 5/8" | 5 3/4" | 3 5/8" | No | 0.19" | Screw Terminals | 00000000 | 000000 |
2 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 4,000 per Year | 1 min. | Push Button | Steel | SPDT | 8 5/8" | 5 3/4" | 3 5/8" | No | 0.19" | Screw Terminals | 00000000 | 000000 |
Panel-Mount Set-to-the-Minute Time and Day Activated Switches
Install these switches in a panel cutout. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. The seven-day timing cycle can perform a different program each day of the week. All have an override to bypass the programmed on/off settings. A backup battery maintains the program during a power outage.
Two-circuit switches can apply a different program to each circuit.
For Panel Cutout | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Industry Designation | Ht. | Wd. | Dp. | Ht. | Wd. | Wire Connection Type | Each | |
7-Day Timing Cycle | ||||||||||||||
1 | 15 A @ 277 V AC | 12V AC/24V AC/24V DC | 20 per Day | 1 min. | Push Button | SPDT | 2.8" | 2.8" | 1.5" | 2.63" | 2.63" | Screw Terminals | 00000000 | 0000000 |
1 | 15 A @ 277 V AC | 120V AC/277V AC | 20 per Day | 1 min. | Push Button | SPDT | 2.8" | 2.8" | 1.5" | 2.63" | 2.63" | Screw Terminals | 000000000 | 000000 |
2 | 15 A @ 250 V AC | 120V AC/240V AC | 20 per Day | 1 min. | Push Button | SPST-NO | 2.8" | 2.8" | 2.2" | 2.68" | 2.68" | Screw Terminals | 00000000 | 000000 |
Surface/DIN-Rail Mount Set-to-the-Minute Time and Day Activated Switches
Mount these switches to a flat surface or attach to DIN rail. More precise than other time and day switches, they program on/off times for equipment down to the exact minute. All have an override to bypass the programmed on/off settings. A backup battery maintains the program during a power outage.
24-hour switches repeat the same program daily. They control two circuits and can apply a different program to each circuit.
Seven-day switches can perform a different program each day of the week.
Mounting | For Panel Cutout | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Industry Designation | Ht. | Wd. | Dp. | Fasteners Included | No. of Holes | For DIN Rail Ht., mm | Ht. | Wd. | Wire Connection Type | Each | |
24-Hour Timing Cycle | |||||||||||||||||
2 | 15 A @ 250 V AC | 120V AC/240V AC | 12 per Day | 1 min. | Push Button | SPST-NO | 3.8" | 3.8" | 2.2" | No | 2 | 35 | 3.62" | 3.62" | Screw Terminals | 00000000 | 0000000 |
7-Day Timing Cycle | |||||||||||||||||
1 | 15 A @ 277 V AC | 12V AC/24V AC/24V DC | 20 per Day | 1 min. | Push Button | SPDT | 4.1" | 2.9" | 2.2" | __ | __ | __ | __ | __ | Screw Terminals | 000000000 | 000000 |
1 | 15 A @ 277 V AC | 120V AC/277V AC | 20 per Day | 1 min. | Push Button | SPDT | 4.1" | 2.9" | 2.2" | __ | __ | __ | __ | __ | Screw Terminals | 000000000 | 000000 |
1 | 15 A @ 277 V AC | 120V AC/277V AC | 50 per Day | 1 min. | Push Button | SPDT | 4.1" | 2.9" | 2.2" | __ | __ | __ | __ | __ | Screw Terminals | 000000000 | 000000 |
Set-to-the-Minute High-Current Time and Day Activated Switches
For precise control of high-current equipment such as landscape lighting, pumps, and heaters, these switches schedule on/off times to the exact minute. A backup battery or capacitor maintains the program during a power outage.
Seven-day switches can perform a different program each day of the week. They have a day skipper that can suspend operation for one to six days.
Two-circuit switches can apply a different program to each circuit.
Mounting | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switching Current @ Voltage | Input Voltage | Maximum On/Off Cycles | Minimum Set Time | Timing Adjustment Style | Industry Designation | Ht. | Wd. | Dp. | Fasteners Included | Hole Dia. | Knockout Trade Size | Wire Connection Type | Environment | Specifications Met | Each | |
24-Hour Timing Cycle | |||||||||||||||||
With Capacitor Backup, Lockout | |||||||||||||||||
1 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 1 min. | Push Button | SPST | 7 7/8" | 5 1/8" | 3 7/16" | No | 3/16" | 1/2, 3/4 | Screw Terminals | Indoor Only | UL Listed, CSA Certified | 0000000 | 0000000 |
2 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 1 min. | Push Button | SPST, DPST | 7 7/8" | 5 1/8" | 3 7/16" | No | 3/16" | 1/2, 3/4 | Screw Terminals | Indoor Only | UL Listed, CSA Certified | 0000000 | 000000 |
7-Day Timing Cycle | |||||||||||||||||
With Capacitor Backup, Lockout, Day Skipper | |||||||||||||||||
1 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 48 per Day | 1 min. | Push Button | SPST | 7 7/8" | 5 1/8" | 3 7/16" | No | 3/16" | 1/2, 3/4 | Screw Terminals | Indoor Only | UL Listed, CSA Certified | 0000000 | 000000 |
With Battery Backup, Lockout, Day Skipper | |||||||||||||||||
2 | 30 A @ 240 V AC | 120V AC/208V AC/240V AC/277V AC | 28 per Day | 1 min. | Push Button | SPST, DPST | 7 3/4" | 5" | 3" | No | 0.16" | 1/2, 3/4 | Screw Terminals | Indoor Only | UL Listed, CSA Certified | 0000000 | 000000 |
Wall-Mount Timer Switches
Use these switches in place of standard wall switches to automatically turn electrical equipment on or off after a set interval of time. They’re often used with lights.
Switches with override can bypass the automatic shut-off.
Set switches with beep and light signals to alert when the timer is almost done; the signals can also be turned off.
Switches with set time recall retain the last setting; hold the button down to restart the timer with that setting.
For technical drawings and 3-D models, click on a part number.
Countdown LCD
and Set Time Recall
No. of Circuits Controlled | Switch Starting Position | Switching Current @ Voltage | Horsepower @ Switching Voltage | Set Time | For Outlet Box Type | Wire Connection Type | Choose a Color | Each | |
With Override | |||||||||
---|---|---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) | 41 mA @ 24 V AC, 12 mA @ 24 V DC | __ | 5 min.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | 000000 | 000000 | |
1 | 1 Off (Normally Open) | 6.6 A @ 120 V AC, 4.3 A @ 277 V AC | 1/6 hp @ 125 V AC | 5 min.-12 hrs. | 1 Device (1 Gang) | Screw Terminals | 000000 | 00000 |