Matching Flow Diagrams to Replace an Air Directional Control Valve
More
Choosing an Air Directional Control Valve
More
Two-Speed Two-Action Electrically Operated Air Directional Control Valves

Often used to extend and then retract a cylinder at different speeds, these valves create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Also known as 4-way and 5/2 valves, they actuate when voltage is applied to the electrical connection. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion.
Valves with spring return actuation go back to their original position when voltage is removed.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
For technical drawings and 3-D models, click on a part number.

O'all | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Lg. | Wd. | Ht. | Mount Type | Choose a Voltage | Each | ||
Single Solenoid—Spring Return Actuation | ||||||||||||||
A | 5 | 10-32 UNF | 10-32 UNF | 8.2 | 0.26 | 44-150 | Not Rated | 3 7/8" | 5/8" | 1 7/8" | Screw In | 0000000 | 0000000 |
Fast-Switching Two-Speed Two-Action Electrically
Operated Air Directional Control Valves

Run through equipment cycles up to 30% faster than with standard valves. These valves shift between flow positions in 1.7 ms. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Also known as 4-way and 5/2 valves, they actuate when voltage is applied to the electrical connection. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by spring, so they go back to their starting position as soon as voltage is removed.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating | Voltage | Wire Connection Type | Lg. | Wd. | Ht. | Environmental Rating | Specifications Met | Each | |
Threaded Female Inlet × Threaded Female Outlet—Threaded Exhaust | |||||||||||||||
5 | 1/4 NPT | 1/4 NPT | 19.22 | 0.544 | 40 to 100 | Not Rated | 24V DC | Solenoid Connectors | 3 7/8" | 3/4" | 1 1/2" | IP65 | EN 175301-803 (Formerly DIN 43650) | 0000000 | 0000000 |
Two-Speed Two-Action Electrically Operated Air
Directional Control Valves with Exhausting Shut-Off
In the off position, these valves exhaust all air pressure, allowing the equipment to return to the neutral position. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Also known as 5/3 exhaust-center valves, they actuate when voltage is applied to the electrical connection. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is electric (solenoid), so they go back to their original position when voltage moves from the first solenoid to the second solenoid. Solenoid connectors are not included for NPT × NPT valves.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
For technical drawings and 3-D models, click on a part number.

O'all | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Lg. | Wd. | Ht. | Mount Type | Mounting Fasteners Included | Voltage | Each | |
Threaded Female Inlet × Threaded Female Outlet—Threaded Exhaust | ||||||||||||||
5 | 1/8 NPT | 1/8 NPT | 19 | 0.6 | 43-145 | Not Rated | 8 3/4" | 7/8" | 2 5/8" | Screw In | Yes | 24V DC | 0000000 | 0000000 |
5 | 1/8 NPT | 1/8 NPT | 19 | 0.6 | 43-145 | Not Rated | 8 3/4" | 7/8" | 2 5/8" | Screw In | Yes | 120V AC | 0000000 | 000000 |
5 | 1/4 NPT | 1/4 NPT | 48 | 1.5 | 43-145 | Not Rated | 9 1/4" | 7/8" | 2 5/8" | Screw In | Yes | 24V DC | 0000000 | 000000 |
5 | 1/4 NPT | 1/4 NPT | 48 | 1.5 | 43-145 | Not Rated | 9 1/4" | 7/8" | 2 5/8" | Screw In | Yes | 120V AC | 0000000 | 000000 |
5 | 3/8 NPT | 3/8 NPT | 79 | 2.5 | 43-145 | Not Rated | 10 3/4" | 1 1/8" | 1 7/8" | Screw In | Yes | 24V DC | 0000000 | 000000 |
5 | 3/8 NPT | 3/8 NPT | 79 | 2.5 | 43-145 | Not Rated | 10 3/4" | 1 1/8" | 1 7/8" | Screw In | Yes | 120V AC | 0000000 | 000000 |
Single-Action Electrically Operated Air Directional Control Valves


These valves create one action, such as extending a cylinder. Apply voltage to the electrical connection to actuate. Also known as 3-way and 3/2 valves, they direct airflow from the inlet to your equipment and exhaust return airflow to create motion. In the off position, they exhaust air from the system, allowing equipment to reset so the action can be repeated.
Normally closed valves block airflow until actuated.
Valves with spring return actuation go back to their original position when voltage is removed.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
For technical drawings and 3-D models, click on a part number.


Valves | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
O'all | Replacement Solenoids | |||||||||||||||
No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate | Flow Coefficient (Cv) | Pressure Range, psi | Lg. | Wd. | Ht. | Mount Type | Voltage | Each | Each | |||
Single Solenoid—Spring Return Actuation | ||||||||||||||||
B | 3 | 1/8 NPT | 1/8 NPT | Threaded | 5.6 scfm @ 100 psi | 0.1 | -14.7 to 14.5 | 3 1/4" | 1 5/8" | 3" | Screw In | 24V DC | 00000000 | 000000 | 000000 | 00 |
B | 3 | 1/4 NPT | 1/4 NPT | Threaded | 6 scfm @ 100 psi | 0.11 | -14.7 to 14.5 | 3 1/4" | 1 5/8" | 3" | Screw In | 24V DC | 00000000 | 00000 | 000000 | 00 |
C | 3 | 1/4 NPT | 1/4 NPT | Threaded | 2.3 scfm @ 100 psi | 0.12 | 0 to 115 | 3" | 7/8" | 2 3/8" | Screw In | 12V DC | 000000000 | 00000 | 00000000 | 000000 |
C | 3 | 1/4 NPT | 1/4 NPT | Threaded | 2.3 scfm @ 100 psi | 0.12 | 0 to 115 | 3" | 7/8" | 2 3/8" | Screw In | 24V DC | 000000000 | 00000 | 00000000 | 00000 |
C | 3 | 1/4 NPT | 1/4 NPT | Threaded | 2.3 scfm @ 100 psi | 0.12 | 0 to 115 | 3" | 7/8" | 2 3/8" | Screw In | 24V AC | 000000000 | 00000 | 00000000 | 00000 |
C | 3 | 1/4 NPT | 1/4 NPT | Threaded | 2.3 scfm @ 100 psi | 0.12 | 0 to 115 | 3" | 7/8" | 2 3/8" | Screw In | 120V AC | 000000000 | 00000 | 00000000 | 00000 |
C | 3 | 1/4 NPT | 1/4 NPT | Threaded | 2.3 scfm @ 100 psi | 0.12 | 0 to 115 | 3" | 7/8" | 2 3/8" | Screw In | 220V AC | 000000000 | 00000 | 000000 | 00 |
Single-Action Electrically Operated Air
Directional Control Valves with Full Shut-Off

Also known as 3-way and 3/3 valves, these valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place. They create one action, such as extending a cylinder. Apply voltage to the electrical connection to actuate. Valves direct airflow from the inlet to your equipment and exhaust return airflow to create motion. They're normally closed to block airflow until actuated. Return actuation is by spring, so they go back to their starting position as soon as voltage is removed.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Voltage | Wire Connection Type | Lg. | Wd. | Ht. | Mounting Fasteners Included | Each | |
Threaded Female Inlet × Threaded Female Outlet | |||||||||||||||
3 | 1/8 NPT | 1/8 NPT | Threaded | 27.36 | 0.59 | 29-102 | 26 | 24V DC | Solenoid Connectors | 2 1/2" | 1 1/8" | 4 3/8" | Yes | 0000000 | 0000000 |
3 | 1/8 NPT | 1/8 NPT | Threaded | 27.4 | 0.59 | 29-102 | 26 | 120V AC | Solenoid Connectors | 2 1/2" | 1 1/8" | 4 3/8" | Yes | 0000000 | 000000 |
3 | 1/4 NPT | 1/4 NPT | Threaded | 41.27 | 0.89 | 29-102 | 26 | 24V DC | Solenoid Connectors | 2 1/2" | 1 1/8" | 4 3/8" | Yes | 0000000 | 000000 |
3 | 1/4 NPT | 1/4 NPT | Threaded | 41.27 | 0.89 | 29-102 | 26 | 120V AC | Solenoid Connectors | 2 1/2" | 1 1/8" | 4 3/8" | Yes | 0000000 | 000000 |
3 | 3/8 NPT | 3/8 NPT | Threaded | 124.0 | 2.2 | 29-102 | 26 | 24V DC | Solenoid Connectors | 3 1/8" | 1 3/8" | 5 3/8" | Yes | 0000000 | 000000 |
3 | 3/8 NPT | 3/8 NPT | Threaded | 124.0 | 2.2 | 29-102 | 26 | 120V AC | Solenoid Connectors | 3 1/8" | 1 3/8" | 5 3/8" | Yes | 0000000 | 000000 |
Simultaneous Two-Action Electrically Operated Air Directional Control Valves

Also known as pressure-center valves and 4-way valves, these valves create two actions at the same time, such as extending two single-acting cylinders at once. Apply voltage to the electrical connection to actuate. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is electric (solenoid), so they go back to their original position when voltage moves from the first solenoid to the second solenoid.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Pipe Size | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating | Voltage | Wire Connection Type | Lg. | Wd. | Ht. | Mounting Fasteners Included | Each | |
5/3 (Pressure Center) | |||||||||||||||
Threaded Female Inlet × Threaded Female Outlet | |||||||||||||||
5 | 1/8 NPT | 1/8 NPT | Threaded | 19 | 0.6 | 43-145 | Not Rated | 24V DC | Solenoid Connectors | 8 3/4" | 7/8" | 2 5/8" | Yes | 0000000 | 0000000 |
5 | 1/8 NPT | 1/8 NPT | Threaded | 19 | 0.6 | 43-145 | Not Rated | 120V AC | Solenoid Connectors | 8 3/4" | 7/8" | 2 5/8" | Yes | 0000000 | 000000 |
5 | 1/4 NPT | 1/4 NPT | Threaded | 48 | 1.5 | 43-145 | Not Rated | 24V DC | Solenoid Connectors | 9 1/4" | 7/8" | 2 5/8" | Yes | 0000000 | 000000 |
5 | 1/4 NPT | 1/4 NPT | Threaded | 48 | 1.5 | 43-145 | Not Rated | 120V AC | Solenoid Connectors | 9 1/4" | 7/8" | 2 5/8" | Yes | 0000000 | 000000 |
5 | 3/8 NPT | 3/8 NPT | Threaded | 79 | 2.5 | 43-145 | Not Rated | 24V DC | Solenoid Connectors | 10 3/4" | 1 1/8" | 2 3/4" | Yes | 0000000 | 000000 |
5 | 3/8 NPT | 3/8 NPT | Threaded | 79 | 2.5 | 43-145 | Not Rated | 120V AC | Solenoid Connectors | 10 3/4" | 1 1/8" | 2 3/4" | Yes | 0000000 | 000000 |
Electrically Operated Air Directional Control Valves with Flow Control
Create motion and control the speed of that motion with a single valve. Also known as 4-way valves, these valves create two actions, such as extending and retracting a double-acting cylinder. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion, and adjust the volume of air exiting an air cylinder (meter out) to control speed. Apply voltage to the electrical connection to actuate.
5/3 (closed center valves) close all ports in the off position to stop equipment in a locked position with air pressure holding it in place. 5/3 (pressure center) valves create two actions at the same time, such as extending two single-acting cylinders at once.
Valves with spring return actuation go back to their original position when voltage is removed. Valves with electric (solenoid) return actuation go back to their original position when voltage moves from the first solenoid to the second solenoid.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
For technical drawings and 3-D models, click on a part number.


Valves | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Inlet Tube | For Outlet Tube | Overall | Replacement Solenoids | |||||||||||||||
No. of Flow Ports | ID | OD | ID | OD | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating | Lg. | Wd. | Ht. | Mounting Fasteners Included | Choose a Voltage | Each | Each | ||
5/2 Flow Pattern | ||||||||||||||||||
Single Solenoid—Spring Return Actuation | ||||||||||||||||||
5 | 11/64" | 1/4" | 11/64" | 1/4" | Threaded | 24.7 | 0.7 | 20-150 | Not Rated | 4 3/4" | 1 3/8" | 2 3/4" | No | 24V DC | 0000000 | 0000000 | 0000000 | 0000000 |
5 | 11/64" | 1/4" | 11/64" | 1/4" | Threaded | 24.7 | 0.7 | 20-150 | Not Rated | 4 3/4" | 1 3/8" | 2 3/4" | No | 120V AC | 0000000 | 000000 | 0000000 | 000000 |
5 | 1/4" | 3/8" | 1/4" | 3/8" | Threaded | 24.7 | 0.7 | 20-150 | Not Rated | 4 3/4" | 1 3/8" | 2 3/4" | No | 24V DC | 0000000 | 000000 | 0000000 | 000000 |
5 | 1/4" | 3/8" | 1/4" | 3/8" | Threaded | 24.7 | 0.7 | 20-150 | Not Rated | 4 3/4" | 1 3/8" | 2 3/4" | No | 120V AC | 0000000 | 000000 | 0000000 | 000000 |
Double Solenoid—Electric (Solenoid) Return Actuation | ||||||||||||||||||
5 | 11/64" | 1/4" | 11/64" | 1/4" | Threaded | 24.7 | 0.7 | 20-150 | Not Rated | 7 3/8" | 1 3/8" | 2 3/4" | No | 000000 | 000000 | 000000 | 00 | |
5 | 1/4" | 3/8" | 1/4" | 3/8" | Threaded | 24.7 | 0.7 | 20-150 | Not Rated | 7 3/8" | 1 3/8" | 2 3/4" | No | 000000 | 000000 | 000000 | 00 | |
5/3 (Closed Center) Flow Pattern | ||||||||||||||||||
Double Solenoid—Electric (Solenoid) Return Actuation | ||||||||||||||||||
5 | 11/64" | 1/4" | 11/64" | 1/4" | Threaded | 24.7 | 0.7 | 20-150 | Not Rated | 7 3/8" | 1 3/8" | 2 3/4" | No | 000000 | 000000 | 000000 | 00 | |
5 | 1/4" | 3/8" | 1/4" | 3/8" | Threaded | 24.7 | 0.7 | 20-150 | Not Rated | 7 3/8" | 1 3/8" | 2 3/4" | No | 000000 | 000000 | 000000 | 00 | |
5/3 (Pressure Center) Flow Pattern | ||||||||||||||||||
Double Solenoid—Electric (Solenoid) Return Actuation | ||||||||||||||||||
5 | 11/64" | 1/4" | 11/64" | 1/4" | Threaded | 24.7 | 0.7 | 20-150 | Not Rated | 7 3/8" | 1 3/8" | 2 3/4" | No | 000000 | 000000 | 000000 | 00 | |
5 | 1/4" | 3/8" | 1/4" | 3/8" | Threaded | 24.7 | 0.7 | 20-150 | Not Rated | 7 3/8" | 1 3/8" | 2 3/4" | No | 000000 | 000000 | 000000 | 00 |
Wear-Resistant Electrically Operated Air Directional Control Valves
Ceramic plates form a longer-lasting seal against oil and dust than rubber seals that deteriorate over time. These valves withstand use in corrosive, dusty, and dirty environments such as foundries, paper mills, and steel plants. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Apply voltage to the electrical connection to actuate. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Also known as 4-way valves.
5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place.
Valves with spring return actuation go back to their original position when voltage is removed. Valves with electric (solenoid) return actuation go back to their original position when voltage moves from the first solenoid to the second solenoid.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.


Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Voltage | Wire Connection Type | Lg. | Wd. | Ht. | Mounting Fasteners Included | Each | |
5/2 Flow Pattern | |||||||||||||||
Single Solenoid—Spring Return Actuation | |||||||||||||||
5 | 1/4 NPT | 1/4 NPT | Threaded | 40 scfm @ 100 psi | 1.1 | 29-150 | 24 | 24V DC | Solenoid Connectors | 6 3/8" | 1 5/8" | 5 3/4" | Yes | 0000000 | 0000000 |
5 | 1/4 NPT | 1/4 NPT | Threaded | 40 scfm @ 100 psi | 1.1 | 29-150 | 24 | 120V AC | Solenoid Connectors | 6 3/8" | 1 5/8" | 5 3/4" | Yes | 0000000 | 000000 |
5 | 3/8 NPT | 3/8 NPT | Threaded | 40 scfm @ 100 psi | 1.1 | 29-150 | 24 | 120V AC | Solenoid Connectors | 6 3/8" | 1 5/8" | 5 3/4" | Yes | 0000000 | 000000 |
Double Solenoid—Electric (Solenoid) Return Actuation | |||||||||||||||
5 | 1/4 NPT | 1/4 NPT | Threaded | 40 scfm @ 100 psi | 1.1 | 29-150 | 24 | 24V DC | Solenoid Connectors | 7 1/2" | 1 5/8" | 5 3/4" | Yes | 0000000 | 000000 |
5 | 1/4 NPT | 1/4 NPT | Threaded | 40 scfm @ 100 psi | 1.1 | 29-150 | 24 | 120V AC | Solenoid Connectors | 7 1/2" | 1 5/8" | 5 3/4" | Yes | 0000000 | 000000 |
5 | 3/8 NPT | 3/8 NPT | Threaded | 40 scfm @ 100 psi | 1.1 | 29-150 | 24 | 24V DC | Solenoid Connectors | 7 1/2" | 1 5/8" | 5 3/4" | Yes | 0000000 | 000000 |
5 | 3/8 NPT | 3/8 NPT | Threaded | 40 scfm @ 100 psi | 1.1 | 29-150 | 24 | 120V AC | Solenoid Connectors | 7 1/2" | 1 5/8" | 5 3/4" | Yes | 0000000 | 000000 |
5/3 (Closed Center) Flow Pattern | |||||||||||||||
Double Solenoid—Electric (Solenoid) Return Actuation | |||||||||||||||
5 | 1/4 NPT | 1/4 NPT | Threaded | 40 scfm @ 100 psi | 1.1 | 44-150 | 24 | 24V DC | Solenoid Connectors | 7 1/2" | 1 5/8" | 5 3/4" | Yes | 0000000 | 000000 |
5 | 1/4 NPT | 1/4 NPT | Threaded | 40 scfm @ 100 psi | 1.1 | 44-150 | 24 | 120V AC | Solenoid Connectors | 7 1/2" | 1 5/8" | 5 3/4" | Yes | 0000000 | 000000 |
5 | 3/8 NPT | 3/8 NPT | Threaded | 40 scfm @ 100 psi | 1.1 | 44-150 | 24 | 24V DC | Solenoid Connectors | 7 1/2" | 1 5/8" | 5 3/4" | Yes | 0000000 | 000000 |
5 | 3/8 NPT | 3/8 NPT | Threaded | 40 scfm @ 100 psi | 1.1 | 44-150 | 24 | 120V AC | Solenoid Connectors | 7 1/2" | 1 5/8" | 5 3/4" | Yes | 0000000 | 000000 |