About Motor Switches and Starters
More
Choosing an Electrical Switch
More
Enclosure Disconnect Switches
Install these switches inside an enclosure to prevent it from opening when power is on—turn the switch to disconnect power and release the door. Cut the shaft to fit the enclosure. Use a padlock (not included) to lock switches in the off position. Mount to DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail. All meet at least one safety standard.
Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
Use optional sealing gaskets in washdown environments; they create an IP65 rated seal around the actuator.
Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
Add junction blocks to connect a ground wire.
Terminal covers prevent contact with live terminals.


Switches | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching | Replacement Shafts | Replacement Shaft Bases | |||||||||||
Current, A | Voltage | Electrical Phase (hp) | Ht. | Wd. | For DIN Rail Ht., mm | Mounting Dp. | Environmental Rating | Each | Each | Each | |||
Gray Plastic Housing with Gray Actuator | |||||||||||||
3 Circuits—For 1 3/16" Panel Cutout Dia. | |||||||||||||
25 | 600V AC | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (1 1/2 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 4 7/8"-15 3/4" | IP40 | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 00000 |
32 | 600V AC | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 4 7/8"-15 3/4" | IP40 | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 0000 |
50 | 600V AC | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 5 5/16"-16 1/8" | IP40 | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 0000 |
63 | 600V AC | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (5 hp @ 120 V AC) Three (10 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 5 5/16"-16 1/8" | IP40 | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 0000 |
80 | 600V AC | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 35 | 5 11/16"-16 1/2" | IP40 | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 0000 |
100 | 600V AC | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (10 hp @ 120 V AC) Three (25 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 35 | 5 11/16"-16 1/2" | IP40 | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 0000 |
Yellow Plastic Housing with Red Actuator | |||||||||||||
3 Circuits—For 1 3/16" Panel Cutout Dia. | |||||||||||||
25 | 600V AC | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (1 1/2 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 4 7/8"-15 3/4" | IP40 | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 0000 |
32 | 600V AC | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 4 7/8"-15 3/4" | IP40 | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 0000 |
50 | 600V AC | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 5 5/16"-16 1/8" | IP40 | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 0000 |
63 | 600V AC | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (5 hp @ 120 V AC) Three (10 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 5 5/16"-16 1/8" | IP40 | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 0000 |
80 | 600V AC | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 35 | 5 11/16"-16 1/2" | IP40 | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 0000 |
100 | 600V AC | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (10 hp @ 120 V AC) Three (25 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 35 | 5 11/16"-16 1/2" | IP40 | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 0000 |
4 Circuits—For 1 3/16" Panel Cutout Dia. | |||||||||||||
25 | 600V AC | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (1 1/2 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 4 7/8"-15 3/4" | IP40 | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 0000 |
32 | 600V AC | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 4 7/8"-15 3/4" | IP40 | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 0000 |
50 | 600V AC | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 5 5/16"-16 1/8" | IP40 | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 0000 |
63 | 600V AC | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (5 hp @ 120 V AC) Three (10 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 5 5/16"-16 1/8" | IP40 | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 0000 |
80 | 600V AC | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 35 | 5 11/16"-16 1/2" | IP40 | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 0000 |
100 | 600V AC | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (10 hp @ 120 V AC) Three (25 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 35 | 5 11/16"-16 1/2" | IP40 | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 0000 |

No. of Circuits Controlled | Switching Current @ Voltage | Switch Starting Position | Industry Designation | Each | |
1 | 10 A @ 600 V AC | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 0000000 | 000000 |
Manual Override Enclosure Disconnect Switches
Keep power running while you access your enclosure. Unlike standard enclosure disconnect switches, which shut off power as you open your enclosure, these have an override function. Engaging the override allows you to take voltage reading, troubleshoot an error code, or fine tune the speed of your line. When the override is off, these work like a standard disconnect switch—a safety interlock prevents your enclosure from opening when power is on. The interlock also prevents the switch from turning on when the door is already open. Cut the shaft to fit your enclosure. All have a lockout so you can secure them in the off position with a padlock (not included).
Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
Add junction blocks to connect a ground wire.
Terminal covers prevent contact with live terminals.
For technical drawings and 3-D models, click on a part number.

Switching | |||||||||
---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Electrical Phase (hp) | Ht. | Wd. | For DIN Rail Ht., mm | Mounting Dp. | Environmental Rating | Each | |
Black Plastic Housing with Black Actuator | |||||||||
3 Circuits with Lockout, Safety Interlock—For 1 1/2" Panel Cutout Dia. | |||||||||
25 | 600V AC | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (1 1/2 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 3" | 4 1/16" | 35 | 4 7/8"-15 3/4" | IP66, NEMA 4X, NEMA 12 | 0000000 | 0000000 |
32 | 600V AC | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3" | 4 1/16" | 35 | 4 7/8"-15 3/4" | IP66, NEMA 4X, NEMA 12 | 0000000 | 000000 |
50 | 600V AC | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 3" | 4 1/16" | 35 | 5 5/16"-16 1/8" | IP66, NEMA 4X, NEMA 12 | 0000000 | 000000 |
63 | 600V AC | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (5 hp @ 120 V AC) Three (10 hp @ 240 V AC) | 3" | 4 1/16" | 35 | 5 5/16"-16 1/8" | IP66, NEMA 4X, NEMA 12 | 0000000 | 000000 |
80 | 600V AC | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 3" | 4 1/16" | 35 | 5 11/16"-16 1/2" | IP66, NEMA 4X, NEMA 12 | 0000000 | 000000 |
100 | 600V AC | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (10 hp @ 120 V AC) Three (25 hp @ 240 V AC) | 3" | 4 1/16" | 35 | 5 11/16"-16 1/2" | IP66, NEMA 4X, NEMA 12 | 0000000 | 000000 |
Black Plastic Housing with Red Actuator | |||||||||
3 Circuits with Lockout, Safety Interlock—For 1 1/2" Panel Cutout Dia. | |||||||||
25 | 600V AC | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (1 1/2 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 3" | 4 1/16" | 35 | 4 7/8"-15 3/4" | IP66, NEMA 4X, NEMA 12 | 0000000 | 000000 |
32 | 600V AC | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3" | 4 1/16" | 35 | 4 7/8"-15 3/4" | IP66, NEMA 4X, NEMA 12 | 0000000 | 000000 |
50 | 600V AC | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 3" | 4 1/16" | 35 | 5 5/16"-16 1/8" | IP66, NEMA 4X, NEMA 12 | 0000000 | 000000 |
63 | 600V AC | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (5 hp @ 120 V AC) Three (10 hp @ 240 V AC) | 3" | 4 1/16" | 35 | 5 5/16"-16 1/8" | IP66, NEMA 4X, NEMA 12 | 0000000 | 000000 |
80 | 600V AC | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 3" | 4 1/16" | 35 | 5 11/16"-16 1/2" | IP66, NEMA 4X, NEMA 12 | 0000000 | 000000 |
100 | 600V AC | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (10 hp @ 120 V AC) Three (25 hp @ 240 V AC) | 3" | 4 1/16" | 35 | 5 11/16"-16 1/2" | IP66, NEMA 4X, NEMA 12 | 0000000 | 000000 |

Switching | ||||||
---|---|---|---|---|---|---|
No. of Circuits Controlled | Current, A | Voltage | Switch Starting Position | Industry Designation | Each | |
1 | 10 | 600V AC | 1 Off (Normally Open) or 1 On (Normally Closed) | SPDT | 0000000 | 000000 |
Enclosure Motor Switches

Designed to mount on an electrical enclosure, these switches control motors, lighting, and electric heat circuits. Your enclosure door will only open when the switch is turned to the off position. This ensures equipment is safely off before you open the electrical enclosure. For an extra layer of safety, use a padlock (not included) on the actuator lever to lock switches in the off position. These switches do not provide overload protection.
Cut the shaft to fit your enclosure. Mount to a DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail.
For technical drawings and 3-D models, click on a part number.
Switching | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | No. of Circuits Controlled | Electrical Phase (hp) | Switch Starting Position | Industry Designation | Ht. | Wd. | For DIN Rail Ht., mm | Mounting Dp. | Wire Connection Type | Environmental Rating | Each | |
Stays Switched (Maintained) | |||||||||||||
25 | 600V AC | 3 | Single (2 hp @ 240 V AC) Single (5 hp @ 480 V AC) Three (5 hp @ 240 V AC) Three (10 hp @ 480 V AC) | 3 Off (Normally Open) | 3PST-NO | 2.4" | 2.4" | 35 | 7 7/8"-14 5/8" | Screw Terminals | IP65 | 0000000 | 0000000 |
32 | 600V AC | 3 | Single (2 hp @ 240 V AC) Single (5 hp @ 480 V AC) Three (5 hp @ 240 V AC) Three (10 hp @ 480 V AC) | 3 Off (Normally Open) | 3PST-NO | 2.4" | 2.4" | 35 | 7 7/8"-14 5/8" | Screw Terminals | IP65 | 0000000 | 000000 |
40 | 600V AC | 3 | Single (3 hp @ 240 V AC) Single (5 hp @ 480 V AC) Three (5 hp @ 240 V AC) Three (10 hp @ 480 V AC) | 3 Off (Normally Open) | 3PST-NO | 2.4" | 2.4" | 35 | 7 7/8"-14 5/8" | Screw Terminals | IP65 | 0000000 | 000000 |
63 | 600V AC | 3 | Three (10 hp @ 240 V AC) Three (20 hp @ 480 V AC) | 3 Off (Normally Open) | 3PST-NO | 2.4" | 2.4" | 35 | 8 1/16"-15 9/16" | Screw Terminals | IP65 | 0000000 | 000000 |
80 | 600V AC | 3 | Three (15 hp @ 240 V AC) Three (30 hp @ 480 V AC) | 3 Off (Normally Open) | 3PST-NO | 2.4" | 2.4" | 35 | 8 1/16"-15 9/16" | Screw Terminals | IP65 | 0000000 | 000000 |
125 | 600V AC | 3 | Three (25 hp @ 240 V AC) Three (50 hp @ 480 V AC) | 3 Off (Normally Open) | 3PST-NO | 3.5" | 3.5" | 35 | 9 1/16"-16 9/16" | Screw Terminals | IP65 | 0000000 | 000000 |
175 | 600V AC | 3 | Three (30 hp @ 240 V AC) Three (50 hp @ 480 V AC) | 3 Off (Normally Open) | 3PST-NO | 3.5" | 3.5" | 35 | 9 1/16"-16 9/16" | Screw Terminals | IP65 | 0000000 | 000000 |