McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    69 Products

    Enclosure Disconnect Switches

    Install these switches inside an enclosure to prevent it from opening when power is on—turn the switch to disconnect power and release the door. Cut the shaft to fit the enclosure. Use a padlock (not included) to lock switches in the off position.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
    Switches with Lockout Only
    Image of Product. 3 Circuits. Front orientation. Contains Annotated. Disconnect Switches. Enclosure Disconnect Switches, Switches with Lockout Only, Plastic Housing, 3 Circuits Controlled.
    Image of Product. 4 Circuits. Front orientation. Contains Annotated. Disconnect Switches. Enclosure Disconnect Switches, Switches with Lockout Only, Plastic Housing, 4 Circuits Controlled.
    Image of Product. Front orientation. Switch Seals. Enclosure Disconnect Switches.

    3 Circuits

    4 Circuits

    Sealing Gaskets

    Mounting Depth—Mount to DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail.
    Enclosure Rating—All meet at least one safety standard.
    Sealing Gaskets—Use sealing gaskets in washdown environments; they create an IP65 rated seal around the actuator.
    Switches
    Replacement
    Shafts
    Replacement
    Shaft Bases
    Sealing Gaskets
    Switching
    Current,
    amp
    Voltage,
    V AC
    Electrical Phase (hp)
    Ht.
    Wd.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Enclosure
    Rating
    Each
    Each
    Each
    Each
    Gray Plastic Housing with Gray Actuator
     
    3 Circuits Controlled—For 1 3/16" Dia. Panel Cutouts
    25600Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    2 5/8"2 5/8"354 7/8" to 15 3/4"IP40
    7277K260000007277K160000007277K17000007277K1800000
    32600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    2 5/8"2 5/8"354 7/8" to 15 3/4"IP40
    7277K27000007277K16000007277K1700007277K180000
    50600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    2 5/8"2 5/8"355 5/16" to 16 1/8"IP40
    7277K28000007277K16000007277K1700007277K180000
    63600Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (5 hp @ 120V AC)
    Three (10 hp @ 240V AC)
    2 5/8"2 5/8"355 5/16" to 16 1/8"IP40
    7277K290000007277K16000007277K1700007277K180000
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3 3/8"3 3/8"355 11/16" to 16 1/2"IP40
    7277K310000007277K16000007277K1700007277K190000
    100600Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (10 hp @ 120V AC)
    Three (25 hp @ 240V AC)
    3 3/8"3 3/8"355 11/16" to 16 1/2"IP40
    7277K320000007277K16000007277K1700007277K190000
     
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled—For 1 3/16" Dia. Panel Cutouts
    25600Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    2 5/8"2 5/8"354 7/8" to 15 3/4"IP40
    7277K51000007277K16000007277K1700007277K180000
    32600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    2 5/8"2 5/8"354 7/8" to 15 3/4"IP40
    7277K52000007277K16000007277K1700007277K180000
    50600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    2 5/8"2 5/8"355 5/16" to 16 1/8"IP40
    7277K53000007277K16000007277K1700007277K180000
    63600Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (5 hp @ 120V AC)
    Three (10 hp @ 240V AC)
    2 5/8"2 5/8"355 5/16" to 16 1/8"IP40
    7277K540000007277K16000007277K1700007277K180000
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3 3/8"3 3/8"355 11/16" to 16 1/2"IP40
    7277K550000007277K16000007277K1700007277K190000
    100600Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (10 hp @ 120V AC)
    Three (25 hp @ 240V AC)
    3 3/8"3 3/8"355 11/16" to 16 1/2"IP40
    7277K560000007277K16000007277K1700007277K190000
     
    4 Circuits Controlled—For 1 3/16" Dia. Panel Cutouts
    25600Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    2 5/8"2 5/8"354 7/8" to 15 3/4"IP40
    7277K330000007277K16000007277K1700007277K180000
    32600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    2 5/8"2 5/8"354 7/8" to 15 3/4"IP40
    7277K340000007277K16000007277K1700007277K180000
    50600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    2 5/8"2 5/8"355 5/16" to 16 1/8"IP40
    7277K350000007277K16000007277K1700007277K180000
    63600Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (5 hp @ 120V AC)
    Three (10 hp @ 240V AC)
    2 5/8"2 5/8"355 5/16" to 16 1/8"IP40
    7277K360000007277K16000007277K1700007277K180000
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3 3/8"3 3/8"355 11/16" to 16 1/2"IP40
    7277K370000007277K16000007277K1700007277K190000
    100600Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (10 hp @ 120V AC)
    Three (25 hp @ 240V AC)
    3 3/8"3 3/8"355 11/16" to 16 1/2"IP40
    7277K380000007277K16000007277K1700007277K190000
     
    Accessories and Replacements for Disconnect Switches

    Enclosure Motor Switches

    Image of Specification. Front orientation. Contains Annotated. Enclosure Motor Switches.
    Designed to mount on an electrical enclosure, these switches control motors, lighting, and electric heat circuits. Your enclosure door will only open when the switch is turned to the off position. This ensures equipment is safely off before you open the electrical enclosure. For an extra layer of safety, use a padlock (not included) on the actuator lever to lock switches in the off position. These switches do not provide overload protection.
    Cut the shaft to fit your enclosure. Mount to a DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail.
    Switching
    No. of Circuits
    Controlled
    Electrical Phase (hp)
    Switch Starting
    Position
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Housing
    Material
    Ht.
    Wd.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Wire
    Connection
    Environment
    Enclosure
    Rating
    Certification
    Each
    Maintained
     
    Lever Actuator
    3Single (2 hp @ 240V AC)
    Single (5 hp @ 480V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    3 Off
    3PST-NO
    25600Plastic2.4"2.4"357 7/8" to 14 5/8"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N110000000
    3Single (2 hp @ 240V AC)
    Single (5 hp @ 480V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    3 Off
    3PST-NO
    32600Plastic2.4"2.4"357 7/8" to 14 5/8"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N12000000
    3Single (3 hp @ 240V AC)
    Single (5 hp @ 480V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    3 Off
    3PST-NO
    40600Plastic2.4"2.4"357 7/8" to 14 5/8"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N13000000
    3Three (10 hp @ 240V AC)
    Three (20 hp @ 480V AC)
    3 Off
    3PST-NO
    63600Plastic2.4"2.4"358 1/16" to 15 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N14000000
    3Three (15 hp @ 240V AC)
    Three (30 hp @ 480V AC)
    3 Off
    3PST-NO
    80600Plastic2.4"2.4"358 1/16" to 15 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N15000000
    3Three (25 hp @ 240V AC)
    Three (50 hp @ 480V AC)
    3 Off
    3PST-NO
    125600Plastic3.5"3.5"359 1/16" to 16 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N16000000
    3Three (30 hp @ 240V AC)
    Three (50 hp @ 480V AC)
    3 Off
    3PST-NO
    175600Plastic3.5"3.5"359 1/16" to 16 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N17000000
     

    Manual Override Enclosure Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Manual Override Enclosure Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Manual Override Enclosure Disconnect Switches.
    Image of Product. Front orientation. Contains Annotated. Disconnect Switches. Manual Override Enclosure Disconnect Switches.

    Power Pole

    Neutral Pole

    Keep power running while you access your enclosure. Unlike standard enclosure disconnect switches, which shut off power as you open your enclosure, these have an override function. Engaging the override allows you to take voltage reading, troubleshoot an error code, or fine tune the speed of your line. Cut the shaft to fit your enclosure.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    Safety Interlock—When the override is off, these work like a standard disconnect switch—a safety interlock prevents your enclosure from opening when power is on. The interlock also prevents the switch from turning on when the door is already open.
    Switching
    Current,
    amp
    Voltage,
    V AC
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Enclosure Rating
    Certification
    Each
    Black Plastic Housing with Black Actuator
     
    3 Circuits Controlled with Lockout and Safety Interlock—For 1 1/2" Dia. Panel Cutouts
    25600Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N170000000
    32600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N18000000
    50600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N19000000
    63600Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (5 hp @ 120V AC)
    Three (10 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N21000000
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N22000000
    100600Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (10 hp @ 120V AC)
    Three (25 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N23000000
     
    Black Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout and Safety Interlock—For 1 1/2" Dia. Panel Cutouts
    25600Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N11000000
    32600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N12000000
    50600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N13000000
    63600Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (5 hp @ 120V AC)
    Three (10 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N14000000
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N15000000
    100600Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (10 hp @ 120V AC)
    Three (25 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N16000000
     
    Accessories and Replacements for Disconnect Switches
    back to top